AzTrials
AzTrials

CataractNCT02609997

Comparison of In-the-bag Stability Between Single-piece and Three-piece Intraocular Lens

A study testing Phacomulsification lens removal cataract surgery with single-piece Intraocular lens(IOL) implantation, Phacomulsification lens removal cataract surgery with three-piece Intraocular lens(IOL) implantation and Subconjunctival dexamethasone in people with Cataract, run by Sun Yat-sen University at 1 site in China.

Completed

Finished. The study has ended and is not enrolling. Results may be posted on the official record.

Official record
Search all trials

Trial summary

Rapid advances of cataract surgery techniques and intraocular lens (IOL) technology have enabled the transition of cataract surgery from blindness relief to refractive correction. An ideal IOL is the critical component to achieve the refractive target of cataract surgery. Read more about this study

Who is it for?
Ages 60 to 85 years
Conditions the study is for
Cataract
What is being tested?
Phacomulsification lens removal cataract surgery with single-piece Intraocular lens(IOL) implantation, Phacomulsification lens removal cataract surgery with three-piece Intraocular lens(IOL) implantation and Subconjunctival dexamethasone
Could I receive a placebo?
No, everyone receives an active treatment
How many people
65 participants
Where
1 siteChina
Study dates
Sep 2012to Dec 2012
Phase
Interventional
Are there results?
None posted in the registry

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 60 to 85 years
  • All sexes
  • No healthy volunteers
  • Adult, Older adult

Who may be able to join

  • diagnosis of bilateral age-related cataract and age between 60 to 85 years

Who cannot join

  • vision-impairing diseases other than cataract, severe refractive error (Preoperative spherical equivalent of either eye >-6.00D or +5.00D)
  • history of ocular trauma, past refractive surgery or other ophthalmic surgery, capsular or zonular disorders that might affect the post-operative centration of IOLs
  • surgical complications including severe hyphema, iris injury, repeated IOL implantation
  • unable to achieve in-the-bag implantation of IOL, corneal sutures during surgery

Trial locations and contacts

1 site in 1 country.

China1 site
  • Zhognshan Ophthalmic Center, Sun Yat-sen University

    Guangzhou, Guangdong, 510060

Other trials in China

About this study

Official title: Comparison of In-the-bag Stability Between Single-piece and Three-piece Intraocular Lens Via Scheimpflug Imaging System

Rapid advances of cataract surgery techniques and intraocular lens (IOL) technology have enabled the transition of cataract surgery from blindness relief to refractive correction. An ideal IOL is the critical component to achieve the refractive target of cataract surgery. Biocompatibility, rate of posterior capsule opacification (PCO) and visual quality have all been suggested as the critical factors of an ideal IOL and widely investigated. Recently, stability of IOL position has also been suggested as one of those critical factors due to its close correlation with postoperative visual function. Data suggests that IOL forward movement of 0.29 mm along the visual axis is associated with -0.4D myopic shift. Wang and colleagues recently reported that 0.5mm decentration of an aspheric IOL could eliminate its aberration-correcting effect. Poor stability could even lead to IOL exchange, an additional surgery that put both surgeons and patients in pain.

As the supporting element of an IOL, the haptics are crucial to keep the IOL in place. Various haptic designs are being compared in terms of position stability of IOLs. Haptic designs of single-piece versus 3-piece are often compared because they are currently the most commonly used types. Single-piece IOLs have soft and broader haptics which are made of the same material as the optic, usually hydrophobic or hydrophilic acrylic, whereas 3-piece IOLs have rigid haptics which are made of poly methyl methacrylate (PMMA). Clinical studies comparing these haptic designs have yielded controversial results regarding their position stability in the capsular bag, which is the most recommended site for IOL fixation in an uneventful cataract surgery.

Read the detailed description

Rapid advances of cataract surgery techniques and intraocular lens (IOL) technology have enabled the transition of cataract surgery from blindness relief to refractive correction. An ideal IOL is the critical component to achieve the refractive target of cataract surgery. Biocompatibility, rate of posterior capsule opacification (PCO) and visual quality have all been suggested as the critical factors of an ideal IOL and widely investigated. Recently, stability of IOL position has also been suggested as one of those critical factors due to its close correlation with postoperative visual function. Data suggests that IOL forward movement of 0.29 mm along the visual axis is associated with -0.4D myopic shift. Wang and colleagues recently reported that 0.5mm decentration of an aspheric IOL could eliminate its aberration-correcting effect. Poor stability could even lead to IOL exchange, an additional surgery that put both surgeons and patients in pain.

As the supporting element of an IOL, the haptics are crucial to keep the IOL in place. Various haptic designs are being compared in terms of position stability of IOLs. Haptic designs of single-piece versus 3-piece are often compared because they are currently the most commonly used types. Single-piece IOLs have soft and broader haptics which are made of the same material as the optic, usually hydrophobic or hydrophilic acrylic, whereas 3-piece IOLs have rigid haptics which are made of poly methyl methacrylate (PMMA). Clinical studies comparing these haptic designs have yielded controversial results regarding their position stability in the capsular bag, which is the most recommended site for IOL fixation in an uneventful cataract surgery.

Most previous studies measure the IOL position based on Purkinje reflections. The measurement is time-consuming and patients are reluctant to cooperate during image acquisition. Purkinje measurement does not detect anterior chamber depth (ACD) and as such cannot reveal the IOL position along the axis. Clinical Scheimpflug systems based on rotating Scheimpflug imaging, on the other hand, is able to acquire sufficient 3-dimensioinal data points within a reasonably short period, usually seconds. It was shown that these systems are one of the best methods to estimate IOL position. To better compare the intracapsular stability between single-piece and 3-piece IOLs, the investigators measured IOL positions with rotating Scheimpflug imaging systems and tested the visual quality of patients implanted with these IOLs.

Conditions
Cataract
Being tested
Phacomulsification lens removal cataract surgery with single-piece Intraocular lens(IOL) implantation, Phacomulsification lens removal cataract surgery with three-piece Intraocular lens(IOL) implantation, Subconjunctival dexamethasone, Viscoelastic materials, proparacaine
Keywords
Intraocular lens
Medical subject headings
Cataract

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • Phacomulsification lens removal cataract surgery with single-piece Intraocular lens(IOL) implantationProcedure or surgery

    The phacoemulsification lens removal cataract surgery is performed with single-piece IOL.During Phacoemulsification.

  • Phacomulsification lens removal cataract surgery with three-piece Intraocular lens(IOL) implantationProcedure or surgery

    The phacoemulsification lens removal cataract surgery is performed with three-piece IOL.During Phacoemulsification.

  • Subconjunctival dexamethasoneDrug

    All patients received subconjunctival dexamethasone (2 mg) during surgery. Topical anesthesia, consisting of a single drop of 0.5% proparacaine (Alcaine, Alcon Laboratories), was administered three times at intervals of 5 minutes prior to surgery

  • Viscoelastic materialsDevice

    viscoelastic materials are used to protect corneal endothelial cells

  • proparacaineDrug

    0.5% proparacaine (Alcaine, Alcon Laboratories)

Study groups in NCT02609997
Study groupRoleWhat they receive
Single-piece IOL GroupExperimentalAge-related cataract patients receive in-the-bag implantation of a single-piece IOL
Receives: Procedure: Phacomulsification lens removal cataract surgery with single-piece Intraocular lens(IOL) implantation; Drug: Subconjunctival dexamethasone; Device: Viscoelastic materials; Drug: proparacaine
Three-piece IOL GroupExperimentalAge-related cataract patients receive in-the-bag implantation of a three-piece IOL
Receives: Procedure: Phacomulsification lens removal cataract surgery with three-piece Intraocular lens(IOL) implantation; Drug: Subconjunctival dexamethasone; Device: Viscoelastic materials; Drug: proparacaine

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. The grade of in-the-bag stability between single-piece intraocular lenses (IOLs) and three-piece intraocular lenses(IOLs)

    Measured: 3 months after the surgery

Secondary outcomes (1)
  1. The visual acuity between single-piece intraocular lenses (IOLs) and three-piece intraocular lenses(IOLs)

    Measured: 3 months after the surgery

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted20 Nov 2015 (estimated)
  2. Study startSep 2012
  3. Primary completionDec 2012
  4. Study completionDec 2012

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Interventional
Phase
Phase N/A
Primary purpose
Treatment
Allocation
Randomised
Intervention model
Parallel groups
Masking
Single blind
Who is masked
Outcomes assessor
Enrolment
65 participants (actual)
IDs, dates and publications
ClinicalTrials.gov ID
NCT02609997
Sponsor's protocol ID
CCPMOH2010-China9
Status last verified
Nov 2015
First submitted
14 Nov 2015
Last updated
20 Nov 2015
Results posted
No
Data monitoring committee
Yes

Publications

  • Korynta J, Bok J, Cendelin J. Changes in refraction induced by change in intraocular lens position. J Refract Corneal Surg. 1994 Sep-Oct;10(5):556-64.

    PubMed 7530106
  • Wang L, Koch DD. Effect of decentration of wavefront-corrected intraocular lenses on the higher-order aberrations of the eye. Arch Ophthalmol. 2005 Sep;123(9):1226-30. doi: 10.1001/archopht.123.9.1226.

    PubMed 16157803
  • Rosales P, Marcos S. Phakometry and lens tilt and decentration using a custom-developed Purkinje imaging apparatus: validation and measurements. J Opt Soc Am A Opt Image Sci Vis. 2006 Mar;23(3):509-20. doi: 10.1364/josaa.23.000509.

    PubMed 16539046
  • de Castro A, Rosales P, Marcos S. Tilt and decentration of intraocular lenses in vivo from Purkinje and Scheimpflug imaging. Validation study. J Cataract Refract Surg. 2007 Mar;33(3):418-29. doi: 10.1016/j.jcrs.2006.10.054.

    PubMed 17321392
  • Zhong X, Long E, Chen W, Xiang W, Liu Z, Chen H, Chen J, Lin Z, Lin H, Chen W. Comparisons of the in-the-bag stabilities of single-piece and three-piece intraocular lenses for age-related cataract patients: a randomized controlled trial. BMC Ophthalmol. 2016 Jul 8;16:100. doi: 10.1186/s12886-016-0283-4.

    PubMed 27392024

Questions about this trial

What is this clinical trial studying?

A study testing Phacomulsification lens removal cataract surgery with single-piece Intraocular lens(IOL) implantation, Phacomulsification lens removal cataract surgery with three-piece Intraocular lens(IOL) implantation and Subconjunctival dexamethasone in people with Cataract, run by Sun Yat-sen University at 1 site in China.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 1 inclusion and 4 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: finished, as of the sponsor's last update on 20 Nov 2015. Status can change between updates, so confirm with the study contact before making plans.

Where is the study taking place?

The record lists 1 site in China. Whether a site is taking part right now should be confirmed with that site. See every site.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.

How can a doctor refer a patient or contact the research team?

The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

The grade of in-the-bag stability between single-piece intraocular lenses (IOLs) and three-piece intraocular lenses(IOLs) (time frame: 3 months after the surgery). It is what the study was designed to measure, not a finding.

Where can I read the original study information?

On the ClinicalTrials.gov record for NCT02609997, which also lists 5 linked publications.

Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 20 Nov 2015.

Free account

Log in to keep searching

You’ve used your 3 free searches. AzTrials is free: log in or create a free account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in