Cardiac Resynchronization TherapyNCT02610673

WiCS-LV Post Market Surveillance Registry

An observational study of Cardiac Resynchronization Therapy, run by EBR Systems, Inc. at 3 sites in 3 countries.

Active, not recruiting

Under way, not looking for participants. Everyone needed has enrolled. The study is still running.

Official record
Search all trials

Trial summary

This is an observational, prospective, non-randomized collection of defined clinical data under normal conditions of use for the WiCS-LV System, an implantable cardiac pacing system capable of delivering pacing energy to the left ventricle of the heart without using a pacing lead. Read more about this study

Who is it for?
Ages 18 years and older
Conditions the study is for
Cardiac Resynchronization Therapy
What is being tested?
WiCS-LV System
Type of treatment
Medical device
How many people
100 participants
Where
3 sitesin 3 countries
Study dates
8 Feb 2016to Jun 2027
How long will I take part?
5 Years
Phase
Observational
Are there results?
Not yet: the study is under way

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 18 years and older
  • All sexes
  • No healthy volunteers
  • Adult, Older adult

Study population: Patients with heart failure meeting standard criteria for CRT based upon the current European Society of Cardiology / European Heart Rhythm Association (ESC/EHRA) guidelines and meeting inclusion criteria.

Who may be able to join

  • Patients with heart failure meeting standard criteria for CRT based upon the current European Society of Cardiology / European Heart Rhythm Association (ESC/EHRA) guidelines and meeting criteria in one of these categorizations:
  • Untreated by conventional CRT:
  • This includes:
  • Patients that have had an attempted but failed CS lead implant due to such complications as venous occlusion, difficult CS access or anatomy, poor lead stability or previous CS repositioning procedures.
  • Patients with a previously implanted CS lead that is programmed off due to such complications as high pacing threshold, non-capture, phrenic nerve stimulation, lead failure, lead dislodgement, or other justifications due to lead issues documented by the prescribing physician.
  • Non-responder to conventional CRT
Show all 13Show fewer
  • This includes:
  • Patients with a previously implanted CRT device who based on prescribing physician judgment experience no change or worsening of heart failure symptoms or no change or worsening of NYHA functional class after 6 months of CRT treatment.
  • Upgrade:
  • This includes:
  • Patients that have a relative contraindication for a CS lead implant such as difficult subclavian access, venous thrombosis, venous occlusion, risk of lead dislodgment, or other justification documented by the prescribing physician.
  • Patients that have a relative contraindication for revising an implanted device to a CRT device such as previous pocket erosion, previous pocket infection, previous explantations, or other justifications documented by the prescribing physicians.
  • Patients with other justifications based upon the prescribing physician's judgment of risk to reopening the device pocket including consideration for the remaining longevity of the pacemaker/ICD battery.

Who cannot join

  • Triple anticoagulation therapy (warfarin, clopidogrel, ASA, or other agents) Stage 4 or 5 renal dysfunction defined as GFR <30 Grade 4 mitral valve regurgitation Thrombocytopenia (platelet count <150,000) Non-ambulatory (or unstable) NYHA class 4 Contraindication to heparin Contraindication to both chronic anticoagulants and antiplatelet agents Contraindication to iodinated contrast agents Insufficient acoustic window to the LV as assessed from diagnostic transthoracic echocardiography Left atrial or left ventricular thrombus Attempted implant of a Pacemaker, ICD, or CRT device within 3 days Life expectancy < 12 months Chronic hemodialysis Myocardial infarction within one month Major cardiac surgery within one month Incompatible electrical stimulation therapy devices, for example transcutaneous electrical nerve stimulation (TENS) or other neurological stimulation devices Exposure to magnetic resonance imaging (MRI) Use of diathermy Use of therapeutic ultrasound Use of echocardiography imaging using vascular, intracardiac, Doppler, and trans-esophageal probes and systems Use of ionizing radiation treatments
  • -

Trial locations and contacts

3 sites in 3 countries.

3 sites in 3 countries

Denmark1 site
  • Aalborg University Hospital

    Aalborg, 9100

Other trials in Denmark

Germany1 site
  • Herzzentrum Brandenburg

    Bernau

Other trials in Germany

Switzerland1 site
  • Cardiocentro Ticini

    Lugano

Other trials in Switzerland

About this study

This is an observational, prospective, non-randomized collection of defined clinical data under normal conditions of use for the WiCS-LV System, an implantable cardiac pacing system capable of delivering pacing energy to the left ventricle of the heart without using a pacing lead.

Patients will be enrolled and followed according to standard of care for 5 years.

Read the detailed description

A clinical registry will be used to collect data from all implanted patients, at all follow-ups and across all implanting centers. Implant procedure will be according to the 'Instruction for Use' of the system and assessments and follow-ups according the best clinical practice.

Anonymized data will be collected on Case Report Forms (CRF) for each patient in the registry. These data will be collected at the time of implant and at scheduled patient in-clinic follow-ups of 1 week, 3 months, 6 months, and 1, 2,3,4,5 years post implant. Patients entering the registry will be given a Registry code suitable to uniquely identify the patient, the implanting center, and the responsible physician.

Data will be consolidated into a dataset by the sponsor for analysis purposes. The sponsor may request support from the center to review patient records in order to monitor the data in cases where the data appears incomplete or appears to be inaccurate.

The data set will be consolidated such that each implanting center may access its own data, or as mutually agreed between centers, aggregate data. Data may be used by centers for purposes of publication or other objectives of the center.

Being tested
WiCS-LV System

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • WiCS-LV SystemDevice

    Also called Wireless Cardiac Stimulation, Wireless Stimulation on the Endocardium - WiSE System

    Implant of left ventricular receiver-electrode and ultrasound transmitter.

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. Complications

    Device and procedure related complications

    Measured: 24 hour perioperative, one month

  2. Performance

    Bi-ventricular capture on 12 lead EKG

    Measured: six months

Secondary outcomes (5)
  1. Device Complications

    Device and procedure related complications

    Measured: six months

  2. Major Complications

    All major complications

    Measured: six months

  3. Complications

    Device and procedure related complications

    Measured: annually to 5 years

  4. Performance

    Bi-ventricular capture on 12 lead EKG

    Measured: annually to 5 years

  5. Evidence of Efficacy

    Clinical composite score (All-cause mortality, HF hospitalizations, NYHA class, and patient global assessment)

    Measured: 6 months

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted20 Nov 2015 (estimated)
  2. Study start8 Feb 2016
  3. Primary completionJun 2027 (estimated)
  4. Study completionJun 2027 (estimated)

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Observational
Observational model
Cohort
Time perspective
Prospective
Enrolment
100 participants (estimated)
Target duration
5 Years
IDs, dates and publications
ClinicalTrials.gov ID
NCT02610673
Sponsor's protocol ID
EBR-02821
Status last verified
Jul 2024
First submitted
18 Nov 2015
Last updated
21 Mar 2025
Results posted
No
Data monitoring committee
No

Publications

  • Sieniewicz BJ, Betts TR, James S, Turley A, Butter C, Seifert M, Boersma LVA, Riahi S, Neuzil P, Biffi M, Diemberger I, Vergara P, Arnold M, Keane DT, Defaye P, Deharo JC, Chow A, Schilling R, Behar J, Rinaldi CA. Real-world experience of leadless left ventricular endocardial cardiac resynchronization therapy: A multicenter international registry of the WiSE-CRT pacing system. Heart Rhythm. 2020 Aug;17(8):1291-1297. doi: 10.1016/j.hrthm.2020.03.002. Epub 2020 Mar 9.

    PubMed 32165181

Questions about this trial

What is this clinical trial studying?

An observational study of Cardiac Resynchronization Therapy, run by EBR Systems, Inc. at 3 sites in 3 countries.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 13 inclusion and 2 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: under way, not looking for participants, as of the sponsor's last update on 21 Mar 2025. Status can change between updates, so confirm with the study contact before making plans.

Where is the study taking place?

The record lists 3 sites in Denmark, Germany, Switzerland. Whether a site is taking part right now should be confirmed with that site. See every site.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

This study is still under way. Results are not available in the source record yet.

How can a doctor refer a patient or contact the research team?

The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

Complications (time frame: 24 hour perioperative, one month). The study lists 2 primary outcomes in all. It is what the study was designed to measure, not a finding.

Where can I read the original study information?

On the ClinicalTrials.gov record for NCT02610673, which also lists 1 linked publication.

Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 21 Mar 2025.

Free account

Log in to keep searching

You’ve used your 3 free searches. AzTrials is free: log in or create a free account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in