Glaucoma DiagnosisNCT02622178

How Accurately Does the Diopsys Visual Evoked Potential (VEP) Vision Testing System Detect Glaucoma?

A study testing Optical Coherence Tomography and Visual evoked potential in people with Glaucoma Diagnosis, run by Wills Eye at 1 site in United States.

Completed

Finished. The study has ended and is not enrolling. Results may be posted on the official record.

Official record
Search all trials

Trial summary

Evaluate sensitivity and specificity of NOVA-DN visually evoked potentials (VEP) protocol and new software method (Corda) for glaucoma detection using optical coherence tomography (OCT) images to differentiate between normal subjects and glaucoma suspects. Read more about this study

Who is it for?
Ages 18 to 90 yearsHealthy volunteers can take part
Conditions the study is for
Glaucoma Diagnosis
What is being tested?
Optical Coherence Tomography and Visual evoked potential
Could I receive a placebo?
No, everyone receives an active treatment
How many people
136 participants
Where
1 siteUnited States
Study dates
Sep 2011to Dec 2013
Phase
Interventional
Are there results?
Yes, posted in the registrySummary in the doctors' view

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 18 to 90 years
  • All sexes
  • Healthy volunteers accepted
  • Adult, Older adult

Who may be able to join

  • Group 1: Healthy Subjects
  • intraocular pressure less than 22 millimeters of mercury (mmHg)
  • normal appearing optic discs and retinal nerve fiber layer (RNFL)
  • normal optical coherence tomography (OCT) RNFL thickness
  • normal visual field (VF) results in both eyes.
  • Group 2: Glaucoma Suspects
Show all 13Show fewer
  • glaucomatous appearance of optic discs and/or RNFL in at least one eye
  • normal OCT
  • normal VF results in both eyes.
  • Group3: Glaucoma Patients
  • Glaucomatous optic disc appearance (cup to disc ratio, rim thinning or RNFL defects)
  • Repeatable intraocular pressure (IOP) of 23 mmHg or more, in at least one eye
  • Repeatable abnormal VF tests

Who cannot join

  • inability to perform reliable VF or OCT
  • visual acuity worse than 20/40
  • refractive error greater than +/-5.00 diopters sphere, greater than +/- 3.00 diopers cylinder

Trial locations and contacts

1 site in 1 country.

United States1 site
  • Wills Eye Hospital

    Philadelphia, Pennsylvania, 19107

Other trials in United States

About this study

Official title: Sensitivity and Specificity of the NOVA-DN VEP Protocol and a Novel Analysis of Optical Coherence Tomography Images for Glaucoma Diagnosis

Evaluate sensitivity and specificity of NOVA-DN visually evoked potentials (VEP) protocol and new software method (Corda) for glaucoma detection using optical coherence tomography (OCT) images to differentiate between normal subjects and glaucoma suspects.

Read the detailed description

The aim of this study was to evaluate the ability of NOVA-DN VEP protocol and Corda parameters to discriminate between healthy eyes and eyes with early to moderate glaucomatous visual field loss. We will evaluate measurements of the NOVA-DN VEP protocol, Corda software and Cirrus spectral domain (SD) OCT software in order to compare and correlate.

Hypotheses is that NOVA-DN VEP protocol and Corda analysis results in a high sensitivity, specificity and area under the Receiver Operating Characteristic (ROC) curves (ROC area) for glaucoma detection. Second hypothesis is NOVA-DN VEP protocol and Corda parameters can differentiate between normal and glaucoma suspects.

Being tested
Optical Coherence Tomography, Visual evoked potential

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • Optical Coherence TomographyDiagnostic test

    Also called OCT

    Optical coherence tomography (OCT) is a noninvasive imaging modality that provides micrometer-scale resolution.It has been revolutionized in recent years by exploitation of Fourier domain (FD) techniques, which have a significant sensitivity advantage over traditional time domain (TD) OCT. In spectral-domain (SD-OCT) the reference mirror is stationary, and OCT signal is acquired using a spectrometer as detector or by varying the wavelength of the light source.

  • Visual evoked potentialDiagnostic test

    Also called VEP

    Visual evoked potential is a means of objectively testing visual field by viewing a computer monitor at 1 meter with a square black/white checkerboard pattern reversal stimulus. Electrodes are placed on the head and face to monitor Electroencephalogram (EEG) activity during testing. Output parameters from VEP system include amplitude and latency measures for each stimuli.

Study groups in NCT02622178
Study groupRoleWhat they receive
Healthy SubjectsExperimental42 Healthy subjects with intraocular pressure less than 22 millimeters of mercury (mmHg), normal appearing optic discs and retinal nerve fiber layer, normal optical coherence technology (RNFL thickness) and normal visual field results in both eyes. Participants will have optical coherence tomography (OCT) and Diopsys visual evoked potential testing (VEP).
Receives: Diagnostic Test: Optical Coherence Tomography; Diagnostic Test: Visual evoked potential
Glaucoma SuspectsExperimental45 Glaucoma suspects with glaucomatous appearance optic discs and/or thin retinal nerve fiber layer in at least one eye, normal optical coherence technology (RNFL thickness) and normal visual field results in both eyes. Participants will have optical coherence tomography (OCT) and Diopsys visual evoked potential testing (VEP).
Receives: Diagnostic Test: Optical Coherence Tomography; Diagnostic Test: Visual evoked potential
Glaucoma PatientsExperimental49 Glaucoma patients with repeatable abnormal visual fields, glaucomatous optic disc appearance (those with cup to disc ratio greater than 0.7, rim thinning or Retinal Nerve Fiber Layer defects indicative of glaucoma) and/or repeatable intra-ocular pressure of 23 mmHg or higher, in at least one eye. Participants will have optical coherence tomography (OCT) and Diopsys visual evoked potential testing (VEP).
Receives: Diagnostic Test: Optical Coherence Tomography; Diagnostic Test: Visual evoked potential

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. Visual Evoked Potential (VEP)

    Diopsys Visual evoked potential (VEP) (Diopsys, Inc. Pine Brook, NJ) is used to objectively measure the functional responses of the entire visual pathway from the anterior segment of the eye to the visual cortex. This is the strength of the signal recorded from the back of the head near where vision is processed in the brain while a visual stimulus is presented to patient.

    Measured: 1 examination, one hour

Secondary outcomes (1)
  1. Retinal Nerve Fiber Layer Thickness

    Optical coherence tomography (OCT) images provide measurement of the retinal nerve fiber layer thickness in microns.

    Measured: 1 examination, one hour

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted4 Dec 2015 (estimated)
  2. Study startSep 2011
  3. Primary completionDec 2013
  4. Study completionDec 2013

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Interventional
Phase
Phase N/A
Primary purpose
Diagnosis
Allocation
Randomised
Intervention model
Parallel groups
Masking
None (open label)
Enrolment
136 participants (actual)
IDs, dates and publications
ClinicalTrials.gov ID
NCT02622178
Sponsor's protocol ID
11-125E
Status last verified
Oct 2018
First submitted
6 Aug 2015
Last updated
15 Nov 2018
Data monitoring committee
No
FDA-regulated drug
No
FDA-regulated device
Yes
Individual data sharing
No: Manuscript has been published.

Publications

  • Waisbourd M, Gensure RH, Aminlari A, Shah SB, Khanna N, Sood N, Molineaux J, Gonzalez A, Myers JS, Katz LJ. Short-duration transient visual evoked potentials and color reflectivity discretization analysis in glaucoma patients and suspects. Int J Ophthalmol. 2017 Feb 18;10(2):254-261. doi: 10.18240/ijo.2017.02.12. eCollection 2017.

    PubMed 28251085

Questions about this trial

What is this clinical trial studying?

A study testing Optical Coherence Tomography and Visual evoked potential in people with Glaucoma Diagnosis, run by Wills Eye at 1 site in United States.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 13 inclusion and 3 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: finished, as of the sponsor's last update on 15 Nov 2018. Status can change between updates, so confirm with the study contact before making plans.

Where is the study taking place?

The record lists 1 site in United States. Whether a site is taking part right now should be confirmed with that site. See every site.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

Yes. Results are posted in the registry (first posted 15 Nov 2018). A summary is in the For doctors view, and the full results are on ClinicalTrials.gov.

How can a doctor refer a patient or contact the research team?

The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

Visual Evoked Potential (VEP) (time frame: 1 examination, one hour). It is what the study was designed to measure, not a finding.

Where can I read the original study information?

On the ClinicalTrials.gov record for NCT02622178, which also lists 1 linked publication.

Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 15 Nov 2018.

Free account

Keep searching with a free account

You’ve used your 3 free searches for this session. Log in or create a free AzTrials account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in