Breast NeoplasmsNCT02638935
Evaluation of Virtual Touch Tissue Imaging Quantification (VTIQ - 2D-SWE) in the Assessment of BI-RADS® 3 and 4 Lesions
A study testing Ultrasound- Virtual Touch Tissue Imaging Quantification in people with Breast Neoplasms, run by Heidelberg University at 11 sites in 6 countries.
Trial summary
The primary aim of this study is to evaluate if VTIQ in addition to BI-RADS® categorization can improve the diagnostic accuracy with respect to detection of malignancies, in particular for BI-RADS® categories 3 and 4a. Read more about this study
- Who is it for?
- Ages 18 years and older, women only
- Conditions the study is for
- Breast Neoplasms
- What is being tested?
- Ultrasound- Virtual Touch Tissue Imaging Quantification
- Type of treatment
- Medical device
- Could I receive a placebo?
- No, everyone receives an active treatment
- How many people
- 1,304 participants
- Where
- 11 sitesin 6 countries
- Study dates
- Feb 2016to Mar 2019
- Phase
- Interventional
- Are there results?
- None posted in the registry
Key requirements
Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.
- Ages 18 years and older
- Women only
- No healthy volunteers
- Adult, Older adult
Who may be able to join
- Female
- Age ≥18 years
- Patients with a lesion ≥ 0.5 cm in largest diameter size, initially scored BI-RADS® 3, 4a, 4b or 4c in B-mode ultrasound
- Informed consent about histological examination (core cut biopsy (CCB), vacuum-assisted biopsy (VAB), fine needle aspiration (FNA) or surgery) has already been given in the course of clinical routine
- Signed informed consent of study participation
Who cannot join
- Pregnant or lactating women
- Women with breast implants on the same side as the lesion
- Women that underwent local radiation or chemotherapy within the last 12 months
- Women with history of breast cancer or breast surgery in the same quadrant
- Lesions in or close to scar tissue (< 1cm)
- Skin lesions or lesions that have been biopsied previously
- Lesion larger than 4 cm in the longest dimension
- No lesion should be included when more than 50% of the lesion is further down than 4 cm beneath the skin level.
Trial locations and contacts
11 sites in 6 countries.
11 sites in 6 countries
Germany6 sites
Franziskus Hospital
Bielefeld, 33615
Universitätsmedizin Greifswald, Klinik für Frauenheilkunde und Geburtshilfe
Greifswald, 17475
University of Heidelberg
Heidelberg, 69120
Universitätsklinikum Marburg, Klinik für Gynäkologie, gyn. Endokrinologie und Onkologie Senologische Diagnostik & Gynäkologischer Ultraschall
Marburg, 35033
LMU Klinikum der Universität München
München, 81377
Universitätsklinikum Tübingen
Tübingen, 72076
France1 site
Institut Gustave Roussy, Service de Radiologie, Villejuif Cedex
Villejuif
Portugal1 site
Centro Hospitalar e Universitário de Coimbra, Departamento de Radiologia
Coimbra, 3000-075
About this study
Official title: Evaluation of Virtual Touch Tissue Imaging Quantification (VTIQ - 2D-SWE) in the Assessment of BI-RADS® 3 and 4 Lesions: Can Patient Selection for Biopsy be Improved? - A Confirmatory Multi-Center-Study
The primary aim of this study is to evaluate if VTIQ in addition to BI-RADS® categorization can improve the diagnostic accuracy with respect to detection of malignancies, in particular for BI-RADS® categories 3 and 4a. The idea of the study is to restage all patients in categories 3 and 4a according to a predefined VTIQ cut-off value of ≥ 3.5 m/s (37 kPa).
Read the detailed description
Elastography is a method of imaging tissue stiffness. It is based on shear wave velocity information that can be mapped to create an image of the stiffness in the region of interest.
Sonoelastography is used to differentiate benign from malignant lesions since malignant lesions alter tissue elasticity.
Adding Shear Wave elastographic features to BI-RADS® feature analysis- especially in lesions scored BI-RADS® 3 and 4a- improved specificity of breast US mass assessment without loss of sensitivity.
The BI-RADS® categories are defined by the risk for a malignant lesion varying from benign BI-RADS® 2 lesions, up to a 2% malignancy rate in BI-RADS® 3 and 2- 95% in BI-RADS® 4 (4a 2-10%; 4b 10-50%; 4c 50-95%). Based on these probabilities, biopsies are recommended for BI-RADS® 4 and 5 lesions and short-term follow-up examinations for BI-RADS® 3. Consequently, up to 2% of the in Ultrasound visible breast cancers are not directly detected as such and put into the BI-RADS® 3 category. In contrast, in the BI-RADS® 4a category more than 90% of the biopsies are unnecessary.
The main aim of the confirmatory study is to use Virtual Touch Tissue Imaging Quantification in order to reduce unnecessary benign biopsies without a reduction of the number of detected cancers.
This multi-center study is planned to involve 12 sites in 7 countries. Recruitment started at the first sites in February 2016. Recruitment takes place in the course of the patient's routine visit at a certified breast unit. All study participants will receive VTIQ in addition to standard ultrasound.
Enrollment goal is a total of 1000 cases, split into groups of a minimum of n= 300 BI-RADS® 3, n= 400 BI-RADS® 4a, n= 100 BI-RADS® 4b, n= 100 BI-RADS® 4c. All patients will be documented in a screening list. Monitoring will be performed by the Coordination Center for Clinical Trials (KKS Heidelberg). Completeness, validity and plausibility of data will be checked in time of data entry (edit-checks) and using validating programs, which will generate queries. The investigator or the designated representatives are obliged to clarify or explain the queries. If no further corrections are to be made in the database it will be closed and used for statistical analysis. All data management procedures will be carried out on validated systems and according to the current Standard Operating Procedures (SOPs) of the Institute of Medical Biometry and Informatics.
The standard BI-RADS® Ultrasound (US) category (BI-RADS® 3-4c) and VTIQ values will be correlated with the histological result. Additionally, local (BI-RADS® given at each site) and central expert BI-RADS® assessment will be compared (BI-RADS® assessment and assessment of the variables leading to the BI-RADS® value separately) to assess the inter-rater reliability. In addition, the BI-RADS® assessments will be compared with the histological results.
The variable "measurement lesion (in m/s)" is derived from three VTIQ measurements as follows:
- For confirmatory analysis of primary objectives an algorithm was established,
- using the first measurement for analysis if the value is smaller than 2.5 m/s or if the value is larger than 4.5 m/s. If the first measurement is smaller than 2.5 m/s, the lesion can be considered benign and no further diagnostics is needed. If the lesion is larger than 4.5 m/s the lesion should be considered suspicious and further diagnostics is required.
- requiring two additional measurements (in total three measurements) if the first measurement is in the range of ≥ 2.5 m/s to ≤ 4.5 m/s. In this case the average of all three measurements is used for analysis.
II. For descriptive analysis other options for derivation of this variable from the three VTIQ measurements will be calculated for discussion:
- First measurement only
- Average of all three measurements
- Median of all three measurements
- Maximum of all three measurements
In conjunction with the maximum VTIQ shear wave velocity the quality display will be used to aid in the classification of lesions as malignant or benign as follows:
- If the shear wave velocity ≥ the cut-off value (3.5 m/s), the lesion is considered potentially malignant, regardless of the outcome of the quality factor
- If a lesion or lesion rim has a completely high quality factor (all green) and a shear wave velocity < the cut-off value (3.5 m/s), the lesion is considered benign.
- If a lesion or lesion rim has mixed high and low quality factors (there are areas with low quality within the mass) and the only area of high quality (green) has a shear wave velocity < the cut-off value (3.5 m/s), then the lesion is indeterminate and malignancy cannot be excluded.
- Conditions
- Breast Neoplasms
- Being tested
- Ultrasound- Virtual Touch Tissue Imaging Quantification
- Keywords
- Virtual Touch Tissue Imaging, VTIQ, Elastography, Breast Cancer, BI-RADS, Differentiation of breast lesions, Breast Lesion
- Medical subject headings
- Breast Neoplasms
What participants receive
What participants receive. In a randomised study each person is assigned to one group by chance.
Ultrasound- Virtual Touch Tissue Imaging QuantificationDevice
Also called Elasticity Imaging, VTIQ, Elastography, Ultrasound
Siemens Medical Solutions USA, Inc. (Mountain View, CA) has implemented Virtual Touch Tissue Imaging Quantification (VTIQ) technology on a commercially available general purpose US imaging system (trade name: Acuson S2000 or S3000). This system has received clearance under Food and Drug Administration (FDA) 510(k) number K072786 (S3000) and K130881 (VTIQ). The technology uses a set of tailored US pulses (Acoustic Radiation Force Impulse, ARFI) to induce shear waves in breast tissue due to tissue displacement. A set of standard B-mode pulses detect the perpendicular shear waves. The displacement signals can be processed using algorithms on a Virtual Touch IQ-equipped system in order to calculate the shear wave velocity.
| Study group | Role | What they receive |
|---|---|---|
| BI-RADS 3 | Other | Intervention: Ultrasound- Virtual Touch Tissue Imaging Quantification Receives: Device: Ultrasound- Virtual Touch Tissue Imaging Quantification |
| BI-RADS 4a | Other | Intervention: Ultrasound- Virtual Touch Tissue Imaging Quantification Receives: Device: Ultrasound- Virtual Touch Tissue Imaging Quantification |
| BI-RADS 4b | Other | Intervention: Ultrasound- Virtual Touch Tissue Imaging Quantification Receives: Device: Ultrasound- Virtual Touch Tissue Imaging Quantification |
| BI-RADS 4c | Other | Intervention: Ultrasound- Virtual Touch Tissue Imaging Quantification Receives: Device: Ultrasound- Virtual Touch Tissue Imaging Quantification |
What is being measured
The primary outcome is the main question the study is designed to answer.
Standard chi-square test at a two-sided significance level of 5% to test the diagnostic accuracy of Virtual Touch Tissue Imaging Quantification (VTIQ) in the differentiation of BI-RADS® 3 and 4a lesions
Hierarchical testing of the main statistical hypotheses H0_1, H0_2, H0_3 (test for H0_1 defines a gatekeeper) to evaluate the diagnostic accuracy of VTIQ in the differentiation of BI-RADS® 3 and 4a lesions:
H0_1: The proportion of malignancies for group A (BI-RADS 4a, VTIQ ≥ cut-off) is less or equal to the proportion of malignancies for group B (BI-RADS 4a, VTIQ < cut-off).
versus
H1_1: The proportion of malignancies for group A is higher than the proportion of malignancies for group B.
Measured: 2 years
Standard Binomial-test according to Bonferroni-Holm to test the null hypothesis H0_2
H0_2: The proportion of malignancies for group B (BI-RADS 4a, VTIQ < cut-off) is larger than or equal to 2%.
versus
H1_2: The proportion of malignancies for group B is smaller than 2%.
Measured: 2 years
Standard Binomial-test according to Bonferroni-Holm to test the null hypothesis H0_3
H0_3: The proportion of malignancies for group D (BI-RADS 3, VTIQ < cut-off) is larger than or equal to 2%.
versus
H1_3: The proportion of malignancies for group D is smaller than 2%.
Measured: 2 years
Secondary outcomes (20)
Corresponding chi-square tests for descriptive analysis of Virtual Touch Tissue Imaging Quantification (VTIQ) in the assessment of BI-RADS® 3, 4b, 4c lesions
Equivalent hypotheses as given for primary outcome measures can be formulated for the patients finally staged as BI-RADS® 3, 4b and 4c. These hypotheses will be analyzed with corresponding chi-square tests, where the resulting p-values are only interpreted descriptively:
To assess whether ultrasonically visualized breast lesions, categorized as BI-RADS® 3/ 4b/ 4c with a VTIQ-measured shear velocity value of smaller than 3.5 m/s (37 kPa), show a lower malignancy rate than BI-RADS® 3/ 4b/ 4c with a VTIQ-measured shear velocity value of larger than or equal to 3.5 m/s (37 kPa).
Measured: 2 years
BI-RADS® vs. BI-RADS® + Virtual Touch Tissue Imaging Quantification (VTIQ)
Two logistic regression models including including BI-RADS® or BI-RADS® and VTIQ will be compared to test whether the probabilities for malignancies predicted with ultrasonically visualized breast lesions categorized as BI-RADS® differ from the probabilities for malignancies predicted with ultrasonically visualized breast lesions categorized as BI-RADS® and VTIQ-measured shear velocity.
Measured: 2 years
Corresponding chi-square tests for descriptive analysis of the strain ratio in the differentiation of BI-RADS® 3, 4a, 4b or 4c lesions
Equivalent hypotheses as given in H0_1 vs H1_1 can be formulated for the patients initially staged as BI-RADS® 3, 4b and 4c. These hypotheses will be analyzed with corresponding chi-square tests, where the resulting p-values are only interpreted descriptively to test whether for women with ultrasonically visualized breast lesions categorized as BI-RADS® 3, 4a, 4b or 4c respectively, the subgroup of women with a strain ratio smaller than or equal to 1 shows a lower malignancy rate than the subgroup of women with a strain ratio of larger than 1.
Measured: 2 years
Robust regression models to test the INTRA-RATER reliability for the original continuous scale
Robust regression models (Passing-Bablok-regression, orthogonal regression) and Bland-Altman Plots will be used for pairwise comparison of the continuous values between raters, where a slope of 1 and an intercept of 0 indicates agreement.
Measured: 2 years
Cohens's Kappa to test the INTRA-RATER reliability for the dichotomized values
Measured: 2 years
Robust regression models to test the INTER-RATER reliability for the original continuous scale
Robust regression models (Passing-Bablok-regression, orthogonal regression) and Bland-Altman Plots will be used for pairwise comparison of the continuous values between raters, where a slope of 1 and an intercept of 0 indicates agreement.
Measured: 2 years
Cohens's Kappa to test the INTER-RATER reliability for the dichotomized values
Measured: 2 years
Descriptive analysis of predictive factors of the continuous VTIQ-value
Thereby the following factors will be examined:
Subject-related factors:
- Skin - breast lesion surface depth (cm)
- Quality factor (color coded scale) within the lesion
- Breast density/ Tissue composition (homogeneous background texture fat, homogeneous background texture fibroglandular, heterogeneous background texture)
- Lesion size in B-mode (cm)
- Normal fatty tissue shear wave velocity (Ratio between measurement in the fatty tissue and in the lesion)
- Pathology (fibroadenoma, lipoma, atypia, cyst condense, "non special type" (NST), invasive lobular carcinoma (ILC), invasive tubular carcinoma (ITC), carcinoma with medullary features, papillary cancer, ductal carcinoma in situ (DCIS), others)
- Grading (G1, G2, G3, Gx)
- Immunohistology (estrogen receptor (ER) status positive/ negative, progesterone receptor (PgR) status positive/ negative, human epidermal growth factor receptor 2 (HER2-neu) status positive/ negative, Ki-67 status (%))
Measured: 2 years
Skin to breast lesion surface depth (cm)
For descriptive analysis of predictive factors of the continuous VTIQ-value, different univariable und multivariable linear regression models will be evaluated and compared.
Thereby one factor to be examined is the skin - breast lesion surface depth (cm).
Measured: 2 years
Quality factor within the lesion assessed using a color coded scale
For descriptive analysis of predictive factors of the continuous VTIQ-value, different univariable und multivariable linear regression models will be evaluated and compared.
Thereby one factor to be examined is the Quality factor (color coded scale) within the lesion.
Measured: 2 years
Breast density/ tissue composition assessed using the morphologic characteristics on US (homogeneous background texture fat, homogeneous background texture fibroglandular, heterogeneous background texture)
For descriptive analysis of predictive factors of the continuous VTIQ-value, different univariable und multivariable linear regression models will be evaluated and compared.
Thereby one factor to be examined is the breast density/ tissue composition (homogeneous background texture fat, homogeneous background texture fibroglandular, heterogeneous background texture).
Measured: 2 years
Lesion size in B-mode Ultrasound (in cm)
For descriptive analysis of predictive factors of the continuous VTIQ-value, different univariable und multivariable linear regression models will be evaluated and compared.
Thereby one factor to be examined is the lesion size in B-mode (cm).
Measured: 2 years
Normal fatty tissue shear wave velocity (ratio between measurement in the fatty tissue and in the lesion)
For descriptive analysis of predictive factors of the continuous VTIQ-value, different univariable und multivariable linear regression models will be evaluated and compared.
Thereby one factor to be examined is the normal fatty tissue shear wave velocity (ratio between measurement in the fatty tissue and in the lesion).
Measured: 2 years
Pathology (fibroadenoma, lipoma, atypia, cyst condense, "non special type" (NST), invasive lobular carcinoma (ILC), invasive tubular carcinoma (ITC), carcinoma with medullary features, papillary cancer, ductal carcinoma in situ (DCIS), others)
For descriptive analysis of predictive factors of the continuous VTIQ-value, different univariable und multivariable linear regression models will be evaluated and compared.
Thereby one factor to be examined is the pathology (fibroadenoma, lipoma, atypia, cyst condense, "non special type" (NST), invasive lobular carcinoma (ILC), invasive tubular carcinoma (ITC), carcinoma with medullary features, papillary cancer, ductal carcinoma in situ (DCIS), others).
Measured: 2 years
Grading (G1, G2, G3, Gx)
For descriptive analysis of predictive factors of the continuous VTIQ-value, different univariable und multivariable linear regression models will be evaluated and compared.
Thereby one factor to be examined is the grading (G1, G2, G3, Gx).
Measured: 2 years
Immunohistology (estrogen receptor (ER) status positive/ negative, progesterone receptor (PgR) status positive/ negative, human epidermal growth factor receptor 2 (HER2-neu) status positive/ negative, Ki-67 status (%))
For descriptive analysis of predictive factors of the continuous VTIQ-value, different univariable und multivariable linear regression models will be evaluated and compared.
Thereby one factor to be examined is the immunohistology (estrogen receptor (ER) status positive/ negative, progesterone receptor (PgR) status positive/ negative, human epidermal growth factor receptor 2 (HER2-neu) status positive/ negative, Ki-67 status (%)).
Measured: 2 years
Cohens's Kappa to determine the inter-rater reliability of BI-RADS® Assessment (local vs. central assessment)
Local (BI-RADS® given at each site) and central expert BI-RADS® assessment will be compared (BI-RADS® assessment and assessment of the variables leading to the BI-RADS® value separately).
To test the inter-rater reliability of BI-RADS® Assessment Cohens' Kappa will be calculated.
Measured: 2 years
Interclass correlation coefficient (ICC) values to determine the inter-rater reliability of BI-RADS® Assessment (local vs. central assessment)
Local (BI-RADS® given at each site) and central expert BI-RADS® assessment will be compared (BI-RADS® assessment and assessment of the variables leading to the BI-RADS® value separately). To test the inter-rater reliability of BI-RADS® Assessment ICC values will be calculated.
Measured: 2 years
BI-RADS® vs. histological results
To compare the BI-RADS® assessments with the histological results, the malignancy rates will be computed separately for each BI-RADS® value. It will then be checked whether these rates lie within the given intervals. Furthermore, the likelihood of malignancy estimated by the experts will be examined using receiver operating curve (ROC) and area under the curve (AUC).
Measured: 2 years
Chi-square test to examine whether the cut-off value of ≥ 3.5 m/s (37kPa) might be increased by increasing the cut-off value step-by-step by a small amount and repeat the primary analysis
We will increase the cut-off value step-by-step by a small amount and repeat the primary analysis (using a chi-square test). We stop the testing procedure as soon as the p-value is above the significance level (0.05). This analysis is, obviously, only an explorative one and has no confirmatory value.
Measured: 2 years
Timeline
From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.
- First posted23 Dec 2015 (estimated)
- Study startFeb 2016
- Primary completionMar 2019
- Study completionMar 2019
Resources
- Official record on ClinicalTrials.govThe registry entry this page is built from, with its full change history.
- Publications (14)Papers the sponsor has linked to this study.
- Other trials for Breast NeoplasmsStudies of the same condition, open and under way.
- What the trial phases meanHow a treatment moves from first tests in people to approval.
More details
For doctors and researchers: how the study is designed, who runs it, and its registry IDs.
Study design
- Study type
- Interventional
- Phase
- Phase N/A
- Primary purpose
- Diagnosis
- Allocation
- Non-randomised
- Intervention model
- Single group
- Masking
- Single blind
- Who is masked
- Outcomes assessor
- Enrolment
- 1,304 participants (actual)
Sponsor and investigators
- Lead sponsor
- Heidelberg University
- Sponsor type
- University, hospital or other
- Collaborators
- Siemens Medical Solutions
- Responsible party
- Principal investigator, Michael Golatta, Heidelberg University
- Investigators
- Michael Golatta, PD Dr. med., MHBA, Principal investigator, University of Heidelberg, Department of Gynecology, Breast Unit
IDs, dates and publications
- ClinicalTrials.gov ID
- NCT02638935
- Sponsor's protocol ID
- VTIQ
- Status last verified
- Apr 2020
- First submitted
- 6 Nov 2015
- Last updated
- 10 Apr 2020
- Results posted
- No
- Data monitoring committee
- Yes
- FDA-regulated drug
- No
- FDA-regulated device
- Yes
Publications
Barr RG, Zhang Z. Shear-wave elastography of the breast: value of a quality measure and comparison with strain elastography. Radiology. 2015 Apr;275(1):45-53. doi: 10.1148/radiol.14132404. Epub 2014 Nov 24.
PubMed 25426770Barr RG, Zhang Z. Effects of precompression on elasticity imaging of the breast: development of a clinically useful semiquantitative method of precompression assessment. J Ultrasound Med. 2012 Jun;31(6):895-902. doi: 10.7863/jum.2012.31.6.895.
PubMed 22644686Golatta M, Schweitzer-Martin M, Harcos A, Schott S, Junkermann H, Rauch G, Sohn C, Heil J. Normal breast tissue stiffness measured by a new ultrasound technique: virtual touch tissue imaging quantification (VTIQ). Eur J Radiol. 2013 Nov;82(11):e676-9. doi: 10.1016/j.ejrad.2013.06.029. Epub 2013 Aug 8.
PubMed 23932637Golatta M, Schweitzer-Martin M, Harcos A, Schott S, Gomez C, Stieber A, Rauch G, Domschke C, Rom J, Schutz F, Sohn C, Heil J. Evaluation of virtual touch tissue imaging quantification, a new shear wave velocity imaging method, for breast lesion assessment by ultrasound. Biomed Res Int. 2014;2014:960262. doi: 10.1155/2014/960262. Epub 2014 Mar 31.
PubMed 24800257Tozaki M, Saito M, Benson J, Fan L, Isobe S. Shear wave velocity measurements for differential diagnosis of solid breast masses: a comparison between virtual touch quantification and virtual touch IQ. Ultrasound Med Biol. 2013 Dec;39(12):2233-45. doi: 10.1016/j.ultrasmedbio.2013.07.012. Epub 2013 Sep 21.
PubMed 24063961Barr RG, Nakashima K, Amy D, Cosgrove D, Farrokh A, Schafer F, Bamber JC, Castera L, Choi BI, Chou YH, Dietrich CF, Ding H, Ferraioli G, Filice C, Friedrich-Rust M, Hall TJ, Nightingale KR, Palmeri ML, Shiina T, Suzuki S, Sporea I, Wilson S, Kudo M. WFUMB guidelines and recommendations for clinical use of ultrasound elastography: Part 2: breast. Ultrasound Med Biol. 2015 May;41(5):1148-60. doi: 10.1016/j.ultrasmedbio.2015.03.008. Epub 2015 Mar 18.
PubMed 25795620Cosgrove DO, Berg WA, Dore CJ, Skyba DM, Henry JP, Gay J, Cohen-Bacrie C; BE1 Study Group. Shear wave elastography for breast masses is highly reproducible. Eur Radiol. 2012 May;22(5):1023-32. doi: 10.1007/s00330-011-2340-y. Epub 2011 Dec 31.
PubMed 22210408Balleyguier C, Canale S, Ben Hassen W, Vielh P, Bayou EH, Mathieu MC, Uzan C, Bourgier C, Dromain C. Breast elasticity: principles, technique, results: an update and overview of commercially available software. Eur J Radiol. 2013 Mar;82(3):427-34. doi: 10.1016/j.ejrad.2012.03.001. Epub 2012 Mar 24.
PubMed 22445593Barr RG, Destounis S, Lackey LB 2nd, Svensson WE, Balleyguier C, Smith C. Evaluation of breast lesions using sonographic elasticity imaging: a multicenter trial. J Ultrasound Med. 2012 Feb;31(2):281-7. doi: 10.7863/jum.2012.31.2.281.
PubMed 22298872Barr RG. Sonographic breast elastography: a primer. J Ultrasound Med. 2012 May;31(5):773-83. doi: 10.7863/jum.2012.31.5.773.
PubMed 22535725Evans A, Whelehan P, Thomson K, Brauer K, Jordan L, Purdie C, McLean D, Baker L, Vinnicombe S, Thompson A. Differentiating benign from malignant solid breast masses: value of shear wave elastography according to lesion stiffness combined with greyscale ultrasound according to BI-RADS classification. Br J Cancer. 2012 Jul 10;107(2):224-9. doi: 10.1038/bjc.2012.253. Epub 2012 Jun 12.
PubMed 22691969Cai L, Pfob A, Barr RG, Duda V, Alwafai Z, Balleyguier C, Clevert DA, Fastner S, Gomez C, Goncalo M, Gruber I, Hahn M, Kapetas P, Nees J, Ohlinger R, Riedel F, Rutten M, Stieber A, Togawa R, Sidey-Gibbons C, Tozaki M, Wojcinski S, Heil J, Golatta M. Deep Learning Model for Breast Shear Wave Elastography to Improve Breast Cancer Diagnosis (INSPiRED 006): An International, Multicenter Analysis. J Clin Oncol. 2025 Nov 10;43(32):3482-3493. doi: 10.1200/JCO-24-02681. Epub 2025 Aug 20.
PubMed 40834300Cai L, Golatta M, Sidey-Gibbons C, Barr RG, Pfob A. The impact of updated imaging software on the performance of machine learning models for breast cancer diagnosis: a multi-center, retrospective study. Arch Gynecol Obstet. 2025 Jul;312(1):139-147. doi: 10.1007/s00404-024-07901-8. Epub 2025 Jan 30.
PubMed 39883137Golatta M, Pfob A, Busch C, Bruckner T, Alwafai Z, Balleyguier C, Clevert DA, Duda V, Goncalo M, Gruber I, Hahn M, Kapetas P, Ohlinger R, Rutten M, Togawa R, Tozaki M, Wojcinski S, Rauch G, Heil J, Barr RG. The potential of combined shear wave and strain elastography to reduce unnecessary biopsies in breast cancer diagnostics - An international, multicentre trial. Eur J Cancer. 2022 Jan;161:1-9. doi: 10.1016/j.ejca.2021.11.005. Epub 2021 Dec 5.
PubMed 34879299
Study at a glance
From the registry record, last updated by the sponsor on 10 Apr 2020. Recruitment status is as the sponsor reported it: confirm with the study team.
- Official title
- Evaluation of Virtual Touch Tissue Imaging Quantification (VTIQ - 2D-SWE) in the Assessment of BI-RADS® 3 and 4 Lesions: Can Patient Selection for Biopsy be Improved? - A Confirmatory Multi-Center-Study
- ClinicalTrials.gov ID
- NCT02638935
- Acronym / sponsor ID
- VTIQ
- Conditions
- Breast Neoplasms
- Keywords
- Virtual Touch Tissue Imaging, VTIQ, Elastography, Breast Cancer, BI-RADS, Differentiation of breast lesions, Breast Lesion
- Study type
- Interventional
- Recruitment status
- Completed
- Enrolment
- 1,304 participants (actual)
- Lead sponsor
- Heidelberg UniversityUniversity, hospital or other
- Collaborators
- Siemens Medical Solutions
- Study start
- Feb 2016
- Primary completion
- Mar 2019 (actual)
- Study completion
- Mar 2019 (actual)
- First posted
- 23 Dec 2015 (estimated)
- Results
- Not posted in the source record
Clinical summary
The research question as the sponsor registered it. This describes what the study plans to test, not what it found.
The primary aim of this study is to evaluate if VTIQ in addition to BI-RADS® categorization can improve the diagnostic accuracy with respect to detection of malignancies, in particular for BI-RADS® categories 3 and 4a. The idea of the study is to restage all patients in categories 3 and 4a according to a predefined VTIQ cut-off value of ≥ 3.5 m/s (37 kPa).
Detailed description
Elastography is a method of imaging tissue stiffness. It is based on shear wave velocity information that can be mapped to create an image of the stiffness in the region of interest.
Sonoelastography is used to differentiate benign from malignant lesions since malignant lesions alter tissue elasticity.
Adding Shear Wave elastographic features to BI-RADS® feature analysis- especially in lesions scored BI-RADS® 3 and 4a- improved specificity of breast US mass assessment without loss of sensitivity.
The BI-RADS® categories are defined by the risk for a malignant lesion varying from benign BI-RADS® 2 lesions, up to a 2% malignancy rate in BI-RADS® 3 and 2- 95% in BI-RADS® 4 (4a 2-10%; 4b 10-50%; 4c 50-95%). Based on these probabilities, biopsies are recommended for BI-RADS® 4 and 5 lesions and short-term follow-up examinations for BI-RADS® 3. Consequently, up to 2% of the in Ultrasound visible breast cancers are not directly detected as such and put into the BI-RADS® 3 category. In contrast, in the BI-RADS® 4a category more than 90% of the biopsies are unnecessary.
The main aim of the confirmatory study is to use Virtual Touch Tissue Imaging Quantification in order to reduce unnecessary benign biopsies without a reduction of the number of detected cancers.
This multi-center study is planned to involve 12 sites in 7 countries. Recruitment started at the first sites in February 2016. Recruitment takes place in the course of the patient's routine visit at a certified breast unit. All study participants will receive VTIQ in addition to standard ultrasound.
Enrollment goal is a total of 1000 cases, split into groups of a minimum of n= 300 BI-RADS® 3, n= 400 BI-RADS® 4a, n= 100 BI-RADS® 4b, n= 100 BI-RADS® 4c. All patients will be documented in a screening list. Monitoring will be performed by the Coordination Center for Clinical Trials (KKS Heidelberg). Completeness, validity and plausibility of data will be checked in time of data entry (edit-checks) and using validating programs, which will generate queries. The investigator or the designated representatives are obliged to clarify or explain the queries. If no further corrections are to be made in the database it will be closed and used for statistical analysis. All data management procedures will be carried out on validated systems and according to the current Standard Operating Procedures (SOPs) of the Institute of Medical Biometry and Informatics.
The standard BI-RADS® Ultrasound (US) category (BI-RADS® 3-4c) and VTIQ values will be correlated with the histological result. Additionally, local (BI-RADS® given at each site) and central expert BI-RADS® assessment will be compared (BI-RADS® assessment and assessment of the variables leading to the BI-RADS® value separately) to assess the inter-rater reliability. In addition, the BI-RADS® assessments will be compared with the histological results.
The variable "measurement lesion (in m/s)" is derived from three VTIQ measurements as follows:
- For confirmatory analysis of primary objectives an algorithm was established,
- using the first measurement for analysis if the value is smaller than 2.5 m/s or if the value is larger than 4.5 m/s. If the first measurement is smaller than 2.5 m/s, the lesion can be considered benign and no further diagnostics is needed. If the lesion is larger than 4.5 m/s the lesion should be considered suspicious and further diagnostics is required.
- requiring two additional measurements (in total three measurements) if the first measurement is in the range of ≥ 2.5 m/s to ≤ 4.5 m/s. In this case the average of all three measurements is used for analysis.
II. For descriptive analysis other options for derivation of this variable from the three VTIQ measurements will be calculated for discussion:
- First measurement only
- Average of all three measurements
- Median of all three measurements
- Maximum of all three measurements
In conjunction with the maximum VTIQ shear wave velocity the quality display will be used to aid in the classification of lesions as malignant or benign as follows:
- If the shear wave velocity ≥ the cut-off value (3.5 m/s), the lesion is considered potentially malignant, regardless of the outcome of the quality factor
- If a lesion or lesion rim has a completely high quality factor (all green) and a shear wave velocity < the cut-off value (3.5 m/s), the lesion is considered benign.
- If a lesion or lesion rim has mixed high and low quality factors (there are areas with low quality within the mass) and the only area of high quality (green) has a shear wave velocity < the cut-off value (3.5 m/s), then the lesion is indeterminate and malignancy cannot be excluded.
Study design
- Primary purpose
- Diagnosis
- Allocation
- Non-randomised
- Intervention model
- Single group
- Masking
- Single blind (outcomes assessor)
- Number of arms
- 4
| Arm | Type | Receives |
|---|---|---|
| BI-RADS 3 | Other | Device: Ultrasound- Virtual Touch Tissue Imaging QuantificationIntervention: Ultrasound- Virtual Touch Tissue Imaging Quantification |
| BI-RADS 4a | Other | Device: Ultrasound- Virtual Touch Tissue Imaging QuantificationIntervention: Ultrasound- Virtual Touch Tissue Imaging Quantification |
| BI-RADS 4b | Other | Device: Ultrasound- Virtual Touch Tissue Imaging QuantificationIntervention: Ultrasound- Virtual Touch Tissue Imaging Quantification |
| BI-RADS 4c | Other | Device: Ultrasound- Virtual Touch Tissue Imaging QuantificationIntervention: Ultrasound- Virtual Touch Tissue Imaging Quantification |
Who may qualify
- Ages
- 18 years and older
- Sex
- Female only
- Healthy volunteers
- Not accepted
- Age groups
- Adult, Older adult
Key inclusion criteria (5 listed)
- Female
- Age ≥18 years
- Patients with a lesion ≥ 0.5 cm in largest diameter size, initially scored BI-RADS® 3, 4a, 4b or 4c in B-mode ultrasound
- Informed consent about histological examination (core cut biopsy (CCB), vacuum-assisted biopsy (VAB), fine needle aspiration (FNA) or surgery) has already been given in the course of clinical routine
- Signed informed consent of study participation
Key exclusion criteria (8 listed)
- Pregnant or lactating women
- Women with breast implants on the same side as the lesion
- Women that underwent local radiation or chemotherapy within the last 12 months
- Women with history of breast cancer or breast surgery in the same quadrant
- Lesions in or close to scar tissue (< 1cm)
Eligibility is decided by the study team after screening; this overview does not establish that a patient qualifies. Full inclusion and exclusion criteria.
Interventions
| Intervention | Type | Arms |
|---|---|---|
| Ultrasound- Virtual Touch Tissue Imaging QuantificationAlso: Elasticity Imaging, VTIQ, Elastography, UltrasoundSiemens Medical Solutions USA, Inc. (Mountain View, CA) has implemented Virtual Touch Tissue Imaging Quantification (VTIQ) technology on a commercially available general purpose US imaging system (trade name: Acuson S2000 or S3000). This system has received clearance under Food and Drug Administration (FDA) 510(k) number K072786 (S3000) and K130881 (VTIQ). The technology uses a set of tailored US pulses (Acoustic Radiation Force Impulse, ARFI) to induce shear waves in breast tissue due to tissue displacement. A set of standard B-mode pulses detect the perpendicular shear waves. The displacement signals can be processed using algorithms on a Virtual Touch IQ-equipped system in order to calculate the shear wave velocity. | Device | BI-RADS 3, BI-RADS 4a, BI-RADS 4b, BI-RADS 4c |
Primary outcome
Standard chi-square test at a two-sided significance level of 5% to test the diagnostic accuracy of Virtual Touch Tissue Imaging Quantification (VTIQ) in the differentiation of BI-RADS® 3 and 4a lesions
Time frame: 2 years
Hierarchical testing of the main statistical hypotheses H0_1, H0_2, H0_3 (test for H0_1 defines a gatekeeper) to evaluate the diagnostic accuracy of VTIQ in the differentiation of BI-RADS® 3 and 4a lesions: H0_1: The proportion of malignancies for group A (BI-RADS 4a, VTIQ ≥ cut-off) is less or equal to the proportion of malignancies for group B (BI-RADS 4a, VTIQ < cut-off). versus H1_1: The proportion of malignancies for group A is higher than the proportion of malignancies for group B.
Standard Binomial-test according to Bonferroni-Holm to test the null hypothesis H0_2
Time frame: 2 years
H0_2: The proportion of malignancies for group B (BI-RADS 4a, VTIQ < cut-off) is larger than or equal to 2%. versus H1_2: The proportion of malignancies for group B is smaller than 2%.
Standard Binomial-test according to Bonferroni-Holm to test the null hypothesis H0_3
Time frame: 2 years
H0_3: The proportion of malignancies for group D (BI-RADS 3, VTIQ < cut-off) is larger than or equal to 2%. versus H1_3: The proportion of malignancies for group D is smaller than 2%.
20 secondary outcomes
Corresponding chi-square tests for descriptive analysis of Virtual Touch Tissue Imaging Quantification (VTIQ) in the assessment of BI-RADS® 3, 4b, 4c lesions
Time frame: 2 years
BI-RADS® vs. BI-RADS® + Virtual Touch Tissue Imaging Quantification (VTIQ)
Time frame: 2 years
Corresponding chi-square tests for descriptive analysis of the strain ratio in the differentiation of BI-RADS® 3, 4a, 4b or 4c lesions
Time frame: 2 years
Robust regression models to test the INTRA-RATER reliability for the original continuous scale
Time frame: 2 years
Cohens's Kappa to test the INTRA-RATER reliability for the dichotomized values
Time frame: 2 years
Robust regression models to test the INTER-RATER reliability for the original continuous scale
Time frame: 2 years
Cohens's Kappa to test the INTER-RATER reliability for the dichotomized values
Time frame: 2 years
Descriptive analysis of predictive factors of the continuous VTIQ-value
Time frame: 2 years
Skin to breast lesion surface depth (cm)
Time frame: 2 years
Quality factor within the lesion assessed using a color coded scale
Time frame: 2 years
Breast density/ tissue composition assessed using the morphologic characteristics on US (homogeneous background texture fat, homogeneous background texture fibroglandular, heterogeneous background texture)
Time frame: 2 years
Lesion size in B-mode Ultrasound (in cm)
Time frame: 2 years
Normal fatty tissue shear wave velocity (ratio between measurement in the fatty tissue and in the lesion)
Time frame: 2 years
Pathology (fibroadenoma, lipoma, atypia, cyst condense, "non special type" (NST), invasive lobular carcinoma (ILC), invasive tubular carcinoma (ITC), carcinoma with medullary features, papillary cancer, ductal carcinoma in situ (DCIS), others)
Time frame: 2 years
Grading (G1, G2, G3, Gx)
Time frame: 2 years
Immunohistology (estrogen receptor (ER) status positive/ negative, progesterone receptor (PgR) status positive/ negative, human epidermal growth factor receptor 2 (HER2-neu) status positive/ negative, Ki-67 status (%))
Time frame: 2 years
Cohens's Kappa to determine the inter-rater reliability of BI-RADS® Assessment (local vs. central assessment)
Time frame: 2 years
Interclass correlation coefficient (ICC) values to determine the inter-rater reliability of BI-RADS® Assessment (local vs. central assessment)
Time frame: 2 years
BI-RADS® vs. histological results
Time frame: 2 years
Chi-square test to examine whether the cut-off value of ≥ 3.5 m/s (37kPa) might be increased by increasing the cut-off value step-by-step by a small amount and repeat the primary analysis
Time frame: 2 years
Results and safety
The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.
Research links
- Official record on ClinicalTrials.govLast updated by the sponsor 10 Apr 2020.
- Background: PubMed 25426770Barr RG, Zhang Z. Shear-wave elastography of the breast: value of a quality measure and comparison with strain elastography. Radiology. 2015 Apr;275(1):45-53. doi: 10.1148/radiol.14132404. Epub 2014 Nov 24.
- Background: PubMed 22644686Barr RG, Zhang Z. Effects of precompression on elasticity imaging of the breast: development of a clinically useful semiquantitative method of precompression assessment. J Ultrasound Med. 2012 Jun;31(6):895-902. doi: 10.7863/jum.2012.31.6.895.
- Background: PubMed 23932637Golatta M, Schweitzer-Martin M, Harcos A, Schott S, Junkermann H, Rauch G, Sohn C, Heil J. Normal breast tissue stiffness measured by a new ultrasound technique: virtual touch tissue imaging quantification (VTIQ). Eur J Radiol. 2013 Nov;82(11):e676-9. doi: 10.1016/j.ejrad.2013.06.029. Epub 2013 Aug 8.
- Background: PubMed 24800257Golatta M, Schweitzer-Martin M, Harcos A, Schott S, Gomez C, Stieber A, Rauch G, Domschke C, Rom J, Schutz F, Sohn C, Heil J. Evaluation of virtual touch tissue imaging quantification, a new shear wave velocity imaging method, for breast lesion assessment by ultrasound. Biomed Res Int. 2014;2014:960262. doi: 10.1155/2014/960262. Epub 2014 Mar 31.
- Background: PubMed 24063961Tozaki M, Saito M, Benson J, Fan L, Isobe S. Shear wave velocity measurements for differential diagnosis of solid breast masses: a comparison between virtual touch quantification and virtual touch IQ. Ultrasound Med Biol. 2013 Dec;39(12):2233-45. doi: 10.1016/j.ultrasmedbio.2013.07.012. Epub 2013 Sep 21.
- Background: PubMed 25795620Barr RG, Nakashima K, Amy D, Cosgrove D, Farrokh A, Schafer F, Bamber JC, Castera L, Choi BI, Chou YH, Dietrich CF, Ding H, Ferraioli G, Filice C, Friedrich-Rust M, Hall TJ, Nightingale KR, Palmeri ML, Shiina T, Suzuki S, Sporea I, Wilson S, Kudo M. WFUMB guidelines and recommendations for clinical use of ultrasound elastography: Part 2: breast. Ultrasound Med Biol. 2015 May;41(5):1148-60. doi: 10.1016/j.ultrasmedbio.2015.03.008. Epub 2015 Mar 18.
- Background: PubMed 22210408Cosgrove DO, Berg WA, Dore CJ, Skyba DM, Henry JP, Gay J, Cohen-Bacrie C; BE1 Study Group. Shear wave elastography for breast masses is highly reproducible. Eur Radiol. 2012 May;22(5):1023-32. doi: 10.1007/s00330-011-2340-y. Epub 2011 Dec 31.
- Background: PubMed 22445593Balleyguier C, Canale S, Ben Hassen W, Vielh P, Bayou EH, Mathieu MC, Uzan C, Bourgier C, Dromain C. Breast elasticity: principles, technique, results: an update and overview of commercially available software. Eur J Radiol. 2013 Mar;82(3):427-34. doi: 10.1016/j.ejrad.2012.03.001. Epub 2012 Mar 24.
- Background: PubMed 22298872Barr RG, Destounis S, Lackey LB 2nd, Svensson WE, Balleyguier C, Smith C. Evaluation of breast lesions using sonographic elasticity imaging: a multicenter trial. J Ultrasound Med. 2012 Feb;31(2):281-7. doi: 10.7863/jum.2012.31.2.281.
- Background: PubMed 22535725Barr RG. Sonographic breast elastography: a primer. J Ultrasound Med. 2012 May;31(5):773-83. doi: 10.7863/jum.2012.31.5.773.
- Background: PubMed 22691969Evans A, Whelehan P, Thomson K, Brauer K, Jordan L, Purdie C, McLean D, Baker L, Vinnicombe S, Thompson A. Differentiating benign from malignant solid breast masses: value of shear wave elastography according to lesion stiffness combined with greyscale ultrasound according to BI-RADS classification. Br J Cancer. 2012 Jul 10;107(2):224-9. doi: 10.1038/bjc.2012.253. Epub 2012 Jun 12.
- Derived from this study: PubMed 40834300Cai L, Pfob A, Barr RG, Duda V, Alwafai Z, Balleyguier C, Clevert DA, Fastner S, Gomez C, Goncalo M, Gruber I, Hahn M, Kapetas P, Nees J, Ohlinger R, Riedel F, Rutten M, Stieber A, Togawa R, Sidey-Gibbons C, Tozaki M, Wojcinski S, Heil J, Golatta M. Deep Learning Model for Breast Shear Wave Elastography to Improve Breast Cancer Diagnosis (INSPiRED 006): An International, Multicenter Analysis. J Clin Oncol. 2025 Nov 10;43(32):3482-3493. doi: 10.1200/JCO-24-02681. Epub 2025 Aug 20.
Related trials for Breast Neoplasms
Not yet recruiting
Effect of a Health Belief Model Based Digital Nudge Intervention on Breast Cancer Screening
Breast Cancer Screening, Breast Cancer Awareness
Active, not recruitingPhase 1/2
A Beta-only IL-2 ImmunoTherapY Study
Advanced Solid Tumor, Unresectable Solid Tumor
Not yet recruitingPhase 2
Low-Dose Apatinib Plus Chemotherapy in ADC-Pretreated HER2-Positive and HER2-Low Advanced Breast Cancer
Breast Neoplasms, Advanced Breast Cancer
RecruitingPhase 3
ROSETTA Breast-01: The Effects and Safety of Pumitamig in Patients With Triple-Negative Breast Cancer
Breast Neoplasms
Active, not recruitingPhase 2
Phase II Study of Dato-DXd in Triple-negative Breast Cancer Patients With Newly Diagnosed or Progressing Brain Metastases
Breast Cancer Stage IV
Referral and contact
AzTrials does not enrol participants or take referrals. Contact the study team or a site listed below; they decide who can take part. This study is not recruiting at the moment.
Michael Golatta, PD Dr. med., MHBA principal investigator
University of Heidelberg, Department of Gynecology, Breast Unit
11 sites in 6 countries: see every site and its status.
Questions about this trial
What is this clinical trial studying?
A study testing Ultrasound- Virtual Touch Tissue Imaging Quantification in people with Breast Neoplasms, run by Heidelberg University at 11 sites in 6 countries.
The full registered description is in the About this study section and the official record.
Who may be eligible to take part?
The sponsor lists 5 inclusion and 8 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.
Is this clinical trial currently recruiting?
The record says: finished, as of the sponsor's last update on 10 Apr 2020. Status can change between updates, so confirm with the study contact before making plans.
Where is the study taking place?
The record lists 11 sites in Germany, United States, France, Japan, Netherlands and 1 more country. Whether a site is taking part right now should be confirmed with that site. See every site.
What are the possible benefits and risks?
They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.
Are results available for this study?
The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.
How can a doctor refer a patient or contact the research team?
The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.
What does the primary outcome measure?
Standard chi-square test at a two-sided significance level of 5% to test the diagnostic accuracy of Virtual Touch Tissue Imaging Quantification (VTIQ) in the differentiation of BI-RADS® 3 and 4a lesions (time frame: 2 years). The study lists 3 primary outcomes in all. It is what the study was designed to measure, not a finding.
Where can I read the original study information?
On the ClinicalTrials.gov record for NCT02638935, which also lists 14 linked publications.
Does a listing mean the treatment is approved or proven to work?
No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.
How often is this information updated?
AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 10 Apr 2020.