Atrial Flutter.Phase 4NCT02698592

Evaluation of Thermocool SF Catheter on the Common Cavo-tricuspid Isthmus Dependent Atrial Flutter Ablation

A Phase 4 study testing CelsiusTMDS® 8 mm catheter, Thermocool® 3.5 mm catheter of irrigated tip and Thermocool® SF catheter in people with Atrial Flutter., run by Hospital Universitario Central de Asturias at 1 site in Spain.

Unknown status

Status not confirmed. The sponsor has not verified this record for over two years, so it may be out of date.

Official record
Search all trials

Trial summary

The purpose of this study is to determine whether the Thermocool SF ® system is at least as effective and safe as regular 8mm catheters and irrigated tip catheters in the treatment of cavo-tricuspid isthmus dependent atrial flutter. Read more about this study

Who is it for?
Ages 18 years and older
Conditions the study is for
Atrial Flutter.
What is being tested?
CelsiusTMDS® 8 mm catheter, Thermocool® 3.5 mm catheter of irrigated tip and Thermocool® SF catheter
Type of treatment
Medical device
Could I receive a placebo?
No, everyone receives an active treatment
How many people
150 participants
Where
1 siteSpain
Study dates
Jan 2012to Dec 2016
Phase
Phase 4
Are there results?
None posted in the registry

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 18 years and older
  • All sexes
  • No healthy volunteers
  • Adult, Older adult

Who may be able to join

  • Patients with symptomatic common atrial flutter.
  • Electrocardiographic documentation of common atrial flutter.

Who cannot join

  • Refusal to give consent.
  • Life expectancy less than 6 months.
  • Contraindication for ablation.
  • Previous cavo-tricuspid isthmus ablation.

Trial locations and contacts

1 site in 1 country.

Spain1 site
  • Hospital Universitario Central de Asturias

    Oviedo, Principality of Asturias, 33011

Other trials in Spain

About this study

Official title: Comparative Study to Assess Safety and Efficacy of Catheters CelsiusTMDS® 8 mm, Thermocool® 3.5 mm of Irrigated Tip and Thermocool® SF in the Treatment of Cavo-tricuspid Isthmus Dependent Atrial Flutter

The purpose of this study is to determine whether the Thermocool SF ® system is at least as effective and safe as regular 8mm catheters and irrigated tip catheters in the treatment of cavo-tricuspid isthmus dependent atrial flutter.

Read the detailed description

The catheter of Biosense Webster Thermocool SF® is characterized by a porous, thin-walled tip allowing a uniform cooling of the catheter tip and so, achieving increased efficiency in cooling. This allows to reduce the flow of irrigation and power output while achieving similar tissue temperatures as the conventional irrigated catheters. There is evidence of greater efficiency of Thermocool SF® catheter in causing tissue damage, but there are no clinical studies on the specific treatment of common atrial flutter.

Investigators hypothesize that the Thermocool SF® system is at least as effective and safe in the treatment of cavo-tricuspid isthmus dependent atrial flutter as conventional and 8 mm irrigated tip catheters.

150 patients with common atrial flutter were randomized to 3 groups of 50 patients and each group underwent ablation catheter ablation with CelsiusTMDS® 8 mm, 3.5 mm irrigated tip Thermocool® or Thermocool® SF respectively. After the procedure, patients are being followed by clinical reviews, electrocardiograms at the 3rd, 6th and 12th months, 24h ECG-Holter examination at the first and 6th month and monthly phone consultation. Rate of recurrence and presence of other supraventricular arrhythmias are being recorded during follow-up.

Conditions
Atrial Flutter.
Being tested
CelsiusTMDS® 8 mm catheter, Thermocool® 3.5 mm catheter of irrigated tip, Thermocool® SF catheter
Keywords
atrial flutter, ablation, Thermocool SF catheter
Medical subject headings
Atrial Flutter

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • CelsiusTMDS® 8 mm catheterDevice

    After demonstrating cavo-tricuspidal isthmic dependant atrial flutter with a duodecapolar catheter, ablation with continuous tissue lesion will be performed with CelsiusTMDS® 8 mm catheter, until complete isthmic block is achieved.

  • Thermocool® 3.5 mm catheter of irrigated tipDevice

    After demonstrating cavo-tricuspidal isthmic dependant atrial flutter with a duodecapolar catheter, ablation with continuous tissue lesion will be performed with Thermocool® 3.5 mm catheter of irrigated tip, until complete isthmic block is achieved.

  • Thermocool® SF catheterDevice

    After demonstrating cavo-tricuspidal isthmic dependant atrial flutter with a duodecapolar catheter, ablation with continuous tissue lesion will be performed with Thermocool® SF catheter, until complete isthmic block is achieved.

Study groups in NCT02698592
Study groupRoleWhat they receive
CelsiusTMDS® 8 mm catheterActive comparator50 patients underwent ablation with CelsiusTMDS® 8 mm catheter.
Receives: Device: CelsiusTMDS® 8 mm catheter
Thermocool® 3.5 mm irrigated catheterActive comparator50 patients underwent ablation with Thermocool® 3.5 mm catheter of irrigated tip.
Receives: Device: Thermocool® 3.5 mm catheter of irrigated tip
Thermocool® SF catheterExperimental50 patients underwent ablation with Thermocool® SF catheter.
Receives: Device: Thermocool® SF catheter

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. Time to get cavo-tricuspid isthmus block

    Measured: during the ablation.

Secondary outcomes (4)
  1. Time of fluoroscopy.

    Measured: during the ablation.

  2. Radio frequency application time.

    Measured: during the ablation.

  3. Complications.

    Defined as vascular complications, cardiac tamponade and outbursts by tissue boiling.

    Measured: within the first 24 hours.

  4. Recurrence of atrial flutter.

    Measured: one year.

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted3 Mar 2016 (estimated)
  2. Study startJan 2012
  3. Primary completionDec 2015
  4. Study completionDec 2016 (estimated)

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Interventional
Phase
Phase 4
Primary purpose
Treatment
Allocation
Randomised
Intervention model
Parallel groups
Masking
Single blind
Who is masked
Participant
Enrolment
150 participants (actual)
IDs, dates and publications
ClinicalTrials.gov ID
NCT02698592
Sponsor's protocol ID
38/2012
Status last verified
Feb 2016
First submitted
29 Feb 2016
Last updated
3 Mar 2016
Results posted
No
Data monitoring committee
No

Publications

  • Tsai CF, Tai CT, Yu WC, Chen YJ, Hsieh MH, Chiang CE, Ding YA, Chang MS, Chen SA. Is 8-mm more effective than 4-mm tip electrode catheter for ablation of typical atrial flutter? Circulation. 1999 Aug 17;100(7):768-71. doi: 10.1161/01.cir.100.7.768.

    PubMed 10449701
  • Jais P, Shah DC, Haissaguerre M, Hocini M, Garrigue S, Le Metayer P, Clementy J. Prospective randomized comparison of irrigated-tip versus conventional-tip catheters for ablation of common flutter. Circulation. 2000 Feb 22;101(7):772-6. doi: 10.1161/01.cir.101.7.772.

    PubMed 10683351
  • Schreieck J, Zrenner B, Kumpmann J, Ndrepepa G, Schneider MA, Deisenhofer I, Schmitt C. Prospective randomized comparison of closed cooled-tip versus 8-mm-tip catheters for radiofrequency ablation of typical atrial flutter. J Cardiovasc Electrophysiol. 2002 Oct;13(10):980-5. doi: 10.1046/j.1540-8167.2002.00980.x.

    PubMed 12435182
  • Scavee C, Georger F, Jamart J, Mancini I, Collet B, Blommaert D, De Roy L. Is a cooled tip catheter the solution for the ablation of the cavotricuspid isthmus? Pacing Clin Electrophysiol. 2003 Jan;26(1P2):328-31. doi: 10.1046/j.1460-9592.2003.00043.x.

    PubMed 12687839

Questions about this trial

What is this clinical trial studying?

A Phase 4 study testing CelsiusTMDS® 8 mm catheter, Thermocool® 3.5 mm catheter of irrigated tip and Thermocool® SF catheter in people with Atrial Flutter., run by Hospital Universitario Central de Asturias at 1 site in Spain.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 2 inclusion and 4 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: status not confirmed, as of the sponsor's last update on 3 Mar 2016. Status can change between updates, so confirm with the study contact before making plans.

Where is the study taking place?

The record lists 1 site in Spain. Whether a site is taking part right now should be confirmed with that site. See every site.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

What does this phase mean?

Phase 4 studies take place after a treatment is approved, to learn more about its long-term benefits and risks in everyday use.

Not every study follows the same path, and some studies (observational studies, device studies) have no phase.

Are results available for this study?

Results are not available in the source record.

How can a doctor refer a patient or contact the research team?

The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

Time to get cavo-tricuspid isthmus block (time frame: during the ablation.). It is what the study was designed to measure, not a finding.

Where can I read the original study information?

On the ClinicalTrials.gov record for NCT02698592, which also lists 4 linked publications.

Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 3 Mar 2016.

Free account

Log in to keep searching

You’ve used your 3 free searches. AzTrials is free: log in or create a free account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in