Cardiovascular Magnetic Resonance-Guided Radiofrequency-Ablation for Atrial Flutter

A study testing ablation for typical atrial flutter and Vision-MR ablation catheter in people with Atrial Flutter, run by University of Leipzig at 1 site in Germany.

Terminated

Stopped early. The study ended before it was planned to and will not resume.

Official record
Search all trials

Trial summary

The purpose of this clinical study is to evaluate the and performance of the Imricor Medical Systems, Inc. (Imricor) MR Ablation Catheter when used with related accessories for the treatment of type I atrial flutter. Read more about this study

Who is it for?
Ages 18 to 75 years
Conditions the study is for
Atrial Flutter
What is being tested?
ablation for typical atrial flutter and Vision-MR ablation catheter
Could I receive a placebo?
No, everyone receives an active treatment
How many people
5 participants
Where
1 siteGermany
Study dates
Mar 2016to 5 Oct 2016
Phase
Interventional
Are there results?
None posted in the registry

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 18 to 75 years
  • All sexes
  • No healthy volunteers
  • Adult, Older adult

Who may be able to join

  • First time indication for ablation for type I atrial flutter.
  • Patients willing and able (mentally and physically capable per physician's discretion) to understand the investigational nature, potential risks and benefits of the study and able to provide written informed consent to participate in the study and agree to comply with follow-up visits and evaluation
  • Patients able to receive anticoagulation therapy to achieve adequate anticoagulation

Who cannot join

  • Contraindication for MRI diagnostic exam
  • A cardiac ablation or cardiac surgery within 180 days prior to enrollment
  • Documented intracardiac thrombus, tumor, bleeding, clotting or other abnormality that precludes catheter introduction and placement
  • Myocardial infarction within 60 days prior to enrollment
  • Current unstable angina
  • History of cerebrovascular event (within 180 days prior to enrollment)
Show all 21Show fewer
  • Patients with an ejection fraction less than or equal to 35% within 90 day prior to enrollment
  • Permanent leads in or through the right atrium
  • Clinically significant structural heart disease (including tricuspid valve regurgitation, tricuspid valve stenosis or other congenital heart disease) that would preclude catheter introduction and placement, as determined by the Investigator
  • Uncompensated congestive heart failure (NYHA Class III or IV)
  • Arrhythmia is secondary to electrolyte imbalance, thyroid disease, or other reversible or non-cardiovascular cause
  • Known sensitivity to heparin or warfarin
  • Active or systemic infection
  • Any other significant uncontrolled or unstable medical condition (including but not limited to hypertension and diabetes)
  • contraindication for conventional ablation procedure know allergy against radiocontrast agents renal insufficiency with glomerular filtration rate < 30ml/min/1,73m2
  • Women who are pregnant or plan to become pregnant within the course of their participation in the investigation or who are breastfeeding
  • Life expectancy of less than 12 months
  • Patients with prosthetic valves
  • Contraindicated for transfemoral venous access
  • Older than 75 years
  • Current enrollment in any other clinical investigation

Trial locations and contacts

1 site in 1 country.

Germany1 site
  • Heart Center Leipzig

    Leipzig, 04289

Other trials in Germany

About this study

Official title: Cardiovascular Magnetic Resonance-Guided Radiofrequency-Ablation for Atrial Flutter: Evaluation of a Tailored Interventional Guidance and Tracking System

The purpose of this clinical study is to evaluate the and performance of the Imricor Medical Systems, Inc. (Imricor) MR Ablation Catheter when used with related accessories for the treatment of type I atrial flutter. The Vision Ablation Catheter and its accessories have been designed for use under fluoroscopic or magnetic resonance guidance. The study will be a single center study conducted at the Leipzig University Hospital Heart Center in Germany. The study population will consist of adult patients requiring ablation for type I atrial flutter.

Read the detailed description

The study will be a single center study conducted at the Leipzig University Hospital Heart Center in Germany. 35 subjects including 5 roll-in subjects meeting inclusion/exclusion criteria will participate in the study. This study requires the use of investigational products from two independent manufacturers: Imricor and Philips. Imricor has developed the ablation catheter with related accessory cables and electrophysiology (EP) recorder/stimulator system. Philips has developed an image guidance and mapping system that is compatible with the Imricor products.

The Vision-MR Ablation Catheter will be used in conjunction with the following investigational products: Advantage-MR EP Recorder/Stimulator, Vision-MR Ablation Cable Set, Vision-MR Diagnostic Cable, the interventional MRI Suite (iSuite) image guidance and mapping system, and a dStream Interface (dSIF-FE). With the exception of iSuite and dSIF-FE, which are manufactured by Philips, Imricor will provide all investigational devices used in the study.

Each procedure will require two single-use Vision-MR Ablation Catheters and one each of the two single-use accessory catheter cables.

Ablation for the treatment of arrhythmia is an inherently complex procedure. Use of the investigational products listed above under MR guidance is an emerging approach to performing the interventional electrophysiology procedure.

The study population will consist of adult patients requiring ablation for type I atrial flutter.

Study subjects will require a follow-up visit or telephone call at seven days post procedure. Accordingly, the expected total study duration is approximately 9 months with study start planned for March 2016.

Conditions
Atrial Flutter
Being tested
ablation for typical atrial flutter, Vision-MR ablation catheter
Keywords
real-time MRI, electrophysiology study, atrial flutter ablation, active tracking
Medical subject headings
Atrial Flutter

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • ablation for typical atrial flutterProcedure or surgery

  • Vision-MR ablation catheterDevice

Study groups in NCT02699034
Study groupRoleWhat they receive
ablation for typical atrial flutterExperimentalThis group receives an MR-guide ablation for atrial flutter with the study device ( Vision-MR ablation catheter )
Receives: Procedure: ablation for typical atrial flutter; Device: Vision-MR ablation catheter

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. Number of patients with bidirectional cavo-tricuspid isthmus block after intervention

    Acute success defined as the demonstration of the established electrophysiological endpoint (e.g. bidirectional cavo-tricuspid isthmus block after radiofrequency application in the cavo-tricuspid isthmus) with the investigational device. Historically, the acute success rate for RF ablation of type I atrial flutter is 72%. Analysis will be based on a binomial proportion and expressed as a percentage. For a total of N subjects with S achieving success, the percentage, represented as P, will be calculated as P = 100*S/N.

    Measured: 9 months

  2. Incidence of Treatment-Emergent Serious Adverse Events [Safety])

    The primary safety endpoint is the rate of serious adverse events (SAEs) related to the device or procedure. Analysis will be based on a binomial proportion and expressed as a percentage. For a total of N subjects with S experiencing an SAE related to the device or procedure, the percentage, represented as P, will be calculated as P = 100*S/N.

    Measured: 9 months

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted4 Mar 2016 (estimated)
  2. Study startMar 2016
  3. Primary completion5 Jun 2016
  4. Study completion5 Oct 2016

Why it stopped: Recommendation by BfArM after interim analysis

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Interventional
Phase
Phase N/A
Primary purpose
Treatment
Allocation
Not applicable
Intervention model
Single group
Masking
None (open label)
Enrolment
5 participants (actual)
IDs, dates and publications
ClinicalTrials.gov ID
NCT02699034
Sponsor's protocol ID
2015-IMR
Status last verified
Feb 2018
First submitted
19 Feb 2016
Last updated
6 Feb 2018
Results posted
No
Data monitoring committee
No
Individual data sharing
No

Publications

  • Hilbert S, Sommer P, Gutberlet M, Gaspar T, Foldyna B, Piorkowski C, Weiss S, Lloyd T, Schnackenburg B, Krueger S, Fleiter C, Paetsch I, Jahnke C, Hindricks G, Grothoff M. Real-time magnetic resonance-guided ablation of typical right atrial flutter using a combination of active catheter tracking and passive catheter visualization in man: initial results from a consecutive patient series. Europace. 2016 Apr;18(4):572-7. doi: 10.1093/europace/euv249. Epub 2015 Aug 27.

    PubMed 26316146

Questions about this trial

What is this clinical trial studying?

A study testing ablation for typical atrial flutter and Vision-MR ablation catheter in people with Atrial Flutter, run by University of Leipzig at 1 site in Germany.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 3 inclusion and 21 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: stopped early, as of the sponsor's last update on 6 Feb 2018. Status can change between updates, so confirm with the study contact before making plans.

Where is the study taking place?

The record lists 1 site in Germany. Whether a site is taking part right now should be confirmed with that site. See every site.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

The study was stopped early (reason given: Recommendation by BfArM after interim analysis). Results are not available in the source record.

How can a doctor refer a patient or contact the research team?

The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

Number of patients with bidirectional cavo-tricuspid isthmus block after intervention (time frame: 9 months). The study lists 2 primary outcomes in all. It is what the study was designed to measure, not a finding.

Where can I read the original study information?

On the ClinicalTrials.gov record for NCT02699034, which also lists 1 linked publication.

Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 6 Feb 2018.

Free account

Log in to keep searching

You’ve used your 3 free searches. AzTrials is free: log in or create a free account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in