Heart DiseaseBIONICSNCT02736344
BIONICS - Pharmacokinetics (PK) Trial
An observational study of Heart Disease, run by Medinol Ltd. at 2 sites in United States.
Trial summary
The BioNIR Ridaforolimus Eluting Coronary Stent System is a single use device/drug combination product comprising: Stent - mounted Cobalt Chromium (CoCr) alloy based stent Delivery System - Rapid Exchange (RX) Coronary System Polymer matrix coating - Poly n-butyl methacrylate (PBMA) and polymer coating (CarboSil®)… Read more about this study
- Who is it for?
- Ages 18 years and older
- Conditions the study is for
- Heart Disease
- What is being tested?
- BioNIR Ridaforolimus Eluting Coronary Stent
- Type of treatment
- Medical device
- How many people
- 12 participants
- Where
- 2 sitesUnited States
- Study dates
- Apr 2016to Sep 2021
- Phase
- Observational
- Are there results?
- None posted in the registry
Key requirements
Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.
- Ages 18 years and older
- All sexes
- No healthy volunteers
- Adult, Older adult
Study population: Subjects with an indication for percutaneous coronary intervention (PCI) with stent implantation for stable angina and/or silent ischemia.
General Inclusion:
- Stable patients (non-ACS) with an indication for possible PCI for stable angina, and/or silent ischemia (in absence of symptoms a visually estimated target lesion diameter stenosis of ≥70%, a positive non-invasive stress test, or Fractional Flow Reserve (FFR) ≤0.80 must be present).
- Patient is willing and able to provide informed written consent and comply with follow-up visits and testing schedule
Angiographic Inclusion Criteria:
- Target lesion(s) must be located in a native coronary artery or bypass graft conduit with visually estimated diameter of ≥2.5mm to ≤4.25mm
- Complex lesions are allowed including calcified lesions (lesion preparation with scoring/cutting and rotational atherectomy are allowed), presence of thrombus that is non-occlusive and does not require thrombectomy, chronic total occlusion (CTO), bifurcation lesions (except planned dual stent implantation), ostial RCA lesions, tortuous lesions, bare metal stent restenotic lesions, protected left main lesions, and saphenous vein graft lesions.
- Overlapping stents are allowed
General Exclusion Criteria:
- PCI with previous BioNIR stent implantation.
- ACS within 1 month of enrollment.
- Patients receive strong CYP3A inhibitors or inducers such as Ketoconazole or Rifampin.
- PCI within the 24 hours preceding the baseline procedure.
- Non-target lesion PCI in the target vessel within 12 months of the baseline procedure.
- History of stent thrombosis.
- Cardiogenic shock (defined as persistent hypotension (systolic blood pressure <90 mm/Hg for more than 30 minutes) or requiring pressors or hemodynamic support, including intra aortic balloon pumping (IABP).
- Subject is intubated.
- Known left ventricular ejection fraction (LVEF) <30%.
- Relative or absolute contraindication to duale antiplatelet therapy (DAPT) for 12 months (including planned surgeries that cannot be delayed)
- Subject has an indication for chronic oral anticoagulant treatment (with either vitamin K antagonists or novel anticoagulants (NOACs)
- Calculated creatinine clearance <30 mL/min using Cockcroft-Gault equation.
- Hemoglobin <10 g/dL.
- Platelet count <100,000 cells/mm3 or >700,000 cells/mm3.
- White blood cell (WBC) count <3,000 cells/mm3.
- Clinically significant liver disease.
- Active peptic ulcer or active bleeding from any site.
- Bleeding from any site within the prior 8 weeks requiring active medical or surgical attention.
- If femoral access is planned, significant peripheral arterial disease which precludes safe insertion of a 6French (6F) sheath.
- History of bleeding diathesis/coagulopathy/will refuse blood transfusions.
- Cerebrovascular accident or transient ischemic attack within the past 6 months, or any permanent neurologic defect attributed to cerebrovascular accident (CVA).
- Known allergy to the study stent components, e.g. cobalt, nickel, chromium, molybdenum, Carbosil®, PBMA, Biolinx polymer, or limus drugs (ridaforolimus, zotarolimus, tacrolimus, sirolimus, everolimus, or similar drugs or any other analogue or derivative or similar compounds).
- Known allergy to protocol-required concomitant medications such as aspirin, or DAPT (clopidogrel, prasugrel, ticagrelor), or heparin and bivalirudin, or iodinated contrast that cannot be adequately pre-medicated.
- Any co-morbid condition that may cause non-compliance with the protocol (e.g. dementia, substance abuse, etc.) or reduced life expectancy to <24 months (e.g. cancer, severe heart failure, severe lung disease).
- Patient participating in or plans to participate in any other investigational drug or device clinical trial that has not reached its primary endpoint.
- Women who are pregnant or breastfeeding (women of child-bearing potential must have a negative pregnancy test within 1week before treatment).
- Women who intend to become pregnant within 12 months after the baseline procedure (women of child-bearing potential who are sexually active must agree to use a reliable method of contraception from the time of screening through 12 months after the baseline procedure).
- Patient has received / is on a waiting list for an organ transplant.
- Patient is receiving or scheduled to receive chemotherapy within 30 days before or any time after the baseline procedure.
- Patient is receiving oral or intravenous immunosuppressive therapy or has known life-limiting immunosuppressive disease (e.g., HIV). Corticosteroids are allowed Angiographic exclusion criteria:
- Target lesions in more than two (2) major coronary arteries (ie, two of left anterior descending artery [LAD], LCX, RCA) including their respective branches (the Ramus Intermedius is defined as a branch of the LCX).
- More than two target lesions per target vessel are planned (two lesions separated by less than 10 mm that can be covered by a single stent are considered as one lesion).
- More than 100mm length planned study stenting in entire coronary tree.
- Occlusive thrombus and/or thrombus requiring thrombectomy in a target vessel.
- Unprotected left main lesions ≥30%, or planned unprotected left main intervention.
- Ostial LAD or LCX target lesions (stenting of any diseased segment within 5 mm of the unprotected left main coronary artery).
- Target Bifurcation lesions with planned dual stent implantation.
- Stenting of target lesions due to DES restenosis.
- Another lesion in a target or non-target vessel (including all side branches) is present that requires or has a high probability of requiring PCI within 12 months after the baseline procedure
Trial locations and contacts
2 sites in 1 country.
United States2 sites
Cardiac and Vascular Research Center of Northern Michigan
Petoskey, Michigan, 49770
Scottsdale Heart Group
Scottsdale, Arizona, 85258
About this study
Official title: BioNIR Ridaforolimus Eluting Coronary Stent System (BioNIR) In Coronary Stenosis - PK Study
The BioNIR Ridaforolimus Eluting Coronary Stent System is a single use device/drug combination product comprising:
- Stent - mounted Cobalt Chromium (CoCr) alloy based stent
- Delivery System - Rapid Exchange (RX) Coronary System
- Polymer matrix coating - Poly n-butyl methacrylate (PBMA) and polymer coating (CarboSil®)
- Ridaforolimus drug - Chemical Abstracts Service (CAS) Registry Number: 572924-54-0 The product is indicated for improving coronary luminal diameter in patients with symptomatic heart disease due to lesions in vessels with reference diameters of 2.5mm to 4.25mm, including complex lesions.
Read the detailed description
The study will be a prospective, multicenter, single-arm study involving up to 4 centers in the US.
The subject population is subjects with an indication for percutaneous coronary intervention (PCI) with stent implantation for stable angina and/or silent ischemia. Twelve (12) consecutive patients referred for PCI or possible PCI with suspected or proven coronary artery disease will be screened and consented.
Twelve (12) consecutive patients referred for PCI or possible PCI with suspected or proven coronary artery disease will be screened and consented. Patients with ACS are not eligible. Patients will be considered enrolled and eligible to receive the BioNIR stent after successful and uncomplicated crossing of the target lesion and successful and uncomplicated lesion preparation (such as pre-dilatation) if needed. At least 30% (4 subjects) will receive more than one stent or a sufficiently long stent so that the total implanted stent dose is >1.5 times the ridaforolimus dose of the workhorse BioNIR stent (3.0x17 mm).
For each patient, a total of up to 14 blood samples will be collected at the following time points: immediately prior to the first stent implant as time 0, at 10 and 30 minutes, and at 1, 2, 4, 8, 12, 24±6, 48±12, 72±12, 168±36 (7 days), 336±36 (14 days) and 720±36 hours (30 days) after the first BioNIR stent implantation. Whole blood concentration of ridaforolimus will be determined using a validated high performance liquid chromatography mass spectrometry/mass spectrometry (HPLC-MS/MS) method. If two consecutive measurements are available and both demonstrate ridaforolimus levels below the detection limit of the assay, the levels at all subsequent time points will not need to be measured.
Relationship to BIONICS STUDY: The general and angiographic inclusion and exclusion criteria will be identical to the pivotal BIONICS trial with the exception of Acute Coronary Syndrome (ACS) patients who will be excluded. Clinical data will be collected in an identical manner to the BIONICS study.
(Clinical follow-up will be performed at 30 days, 6 months, and 1, 2, 3, 4, and 5 years post enrollment.) The following pharmacokinetic parameters will be evaluated: maximum concentration (Cmax), Cmax adjusted by treatment dose, time to maximum concentration (tmax), the time of the last quantifiable concentration (tlast ), half-life time ( t1/2), total area under the concentration-time curve from time 0 to tlast (AUC0-tlast), total area under the concentration-time curve from time 0 to tlast (AUC0-t∞) and total body clearance (CL). AUCs normalized by treatment dose will also be derived.
12 subjects will be enrolled in order to evaluate the pharmacokinetic parameters of ridaforolimus release from the BioNIR stent. The number of subjects was chosen based on experience in the literature from other 'limus' drug eluting stents as well as specific request from FDA.
- Conditions
- Heart Disease
- Being tested
- BioNIR Ridaforolimus Eluting Coronary Stent
- Keywords
- coronary luminal diameter, lesions, vessels
- Medical subject headings
- Heart Diseases
What participants receive
What participants receive. In a randomised study each person is assigned to one group by chance.
BioNIR Ridaforolimus Eluting Coronary StentDevice
| Study group | Role | What they receive |
|---|---|---|
| BioNIR Ridaforolimus (drug eluting stent (DES) | The BioNIR Ridaforolimus Eluting Coronary Stent System is a single use device/drug combination product comprising:
* Stent - a mounted Cobalt Chromium (CoCr) alloy based stent
* Delivery System - Rapid Exchange (RX) Coronary System
* Polymer matrix coating - Poly n-butyl methacrylate (PBMA) and CarboSil®
* Ridaforolimus drug - CAS Registry Number: 572924-54-0
The drug Ridaforolimus is utilized on the stent system at a dose of 1.1 μg/mm2 (with a drug load of 100 μg per 2.75/3.00 x 17 mm stent). Receives: Device: BioNIR Ridaforolimus Eluting Coronary Stent |
What is being measured
The primary outcome is the main question the study is designed to answer.
Maximum concentration (Cmax)
Maximum concentration (Cmax)
Measured: For each patient, a total of up to 14 blood samples will be collected at the following time points: immediately prior to the first stent implant as time 0, at 10 and 30 minutes, and at 1, 2, 4, 8, 12, 24±6, 48±12, 72±12, 168±36 hours.
Timeline
From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.
- First posted13 Apr 2016 (estimated)
- Study startApr 2016
- Primary completionFeb 2017
- Study completionSep 2021
Resources
- Official record on ClinicalTrials.govThe registry entry this page is built from, with its full change history.
- Other trials for Heart DiseaseStudies of the same condition, open and under way.
- What the trial phases meanHow a treatment moves from first tests in people to approval.
More details
For doctors and researchers: how the study is designed, who runs it, and its registry IDs.
Study design
- Study type
- Observational
- Observational model
- Cohort
- Time perspective
- Prospective
- Enrolment
- 12 participants (actual)
Sponsor and investigators
- Lead sponsor
- Medinol Ltd.
- Sponsor type
- Industry (pharma, biotech, devices)
- Responsible party
- Sponsor
- Investigators
- David Rizik, MD, Principal investigator, Scottsdale Heart Group
IDs, dates and publications
- ClinicalTrials.gov ID
- NCT02736344
- Sponsor's protocol ID
- BioNIR PK- 001
- Acronym
- BIONICS
- Status last verified
- Aug 2021
- First submitted
- 15 Mar 2016
- Last updated
- 13 Apr 2022
- Results posted
- No
- Data monitoring committee
- Yes
- Individual data sharing
- No
Study at a glance
From the registry record, last updated by the sponsor on 13 Apr 2022. Recruitment status is as the sponsor reported it: confirm with the study team.
- Official title
- BioNIR Ridaforolimus Eluting Coronary Stent System (BioNIR) In Coronary Stenosis - PK Study
- ClinicalTrials.gov ID
- NCT02736344
- Acronym / sponsor ID
- BIONICS / BioNIR PK- 001
- Conditions
- Heart Disease
- Keywords
- coronary luminal diameter, lesions, vessels
- Study type
- Observational
- Recruitment status
- Completed
- Enrolment
- 12 participants (actual)
- Lead sponsor
- Medinol Ltd.Industry (pharma, biotech, devices)
- Study start
- Apr 2016
- Primary completion
- Feb 2017 (actual)
- Study completion
- Sep 2021 (actual)
- First posted
- 13 Apr 2016 (estimated)
- Results
- Not posted in the source record
Clinical summary
The research question as the sponsor registered it. This describes what the study plans to test, not what it found.
The BioNIR Ridaforolimus Eluting Coronary Stent System is a single use device/drug combination product comprising:
- Stent - mounted Cobalt Chromium (CoCr) alloy based stent
- Delivery System - Rapid Exchange (RX) Coronary System
- Polymer matrix coating - Poly n-butyl methacrylate (PBMA) and polymer coating (CarboSil®)
- Ridaforolimus drug - Chemical Abstracts Service (CAS) Registry Number: 572924-54-0 The product is indicated for improving coronary luminal diameter in patients with symptomatic heart disease due to lesions in vessels with reference diameters of 2.5mm to 4.25mm, including complex lesions.
Detailed description
The study will be a prospective, multicenter, single-arm study involving up to 4 centers in the US.
The subject population is subjects with an indication for percutaneous coronary intervention (PCI) with stent implantation for stable angina and/or silent ischemia. Twelve (12) consecutive patients referred for PCI or possible PCI with suspected or proven coronary artery disease will be screened and consented.
Twelve (12) consecutive patients referred for PCI or possible PCI with suspected or proven coronary artery disease will be screened and consented. Patients with ACS are not eligible. Patients will be considered enrolled and eligible to receive the BioNIR stent after successful and uncomplicated crossing of the target lesion and successful and uncomplicated lesion preparation (such as pre-dilatation) if needed. At least 30% (4 subjects) will receive more than one stent or a sufficiently long stent so that the total implanted stent dose is >1.5 times the ridaforolimus dose of the workhorse BioNIR stent (3.0x17 mm).
For each patient, a total of up to 14 blood samples will be collected at the following time points: immediately prior to the first stent implant as time 0, at 10 and 30 minutes, and at 1, 2, 4, 8, 12, 24±6, 48±12, 72±12, 168±36 (7 days), 336±36 (14 days) and 720±36 hours (30 days) after the first BioNIR stent implantation. Whole blood concentration of ridaforolimus will be determined using a validated high performance liquid chromatography mass spectrometry/mass spectrometry (HPLC-MS/MS) method. If two consecutive measurements are available and both demonstrate ridaforolimus levels below the detection limit of the assay, the levels at all subsequent time points will not need to be measured.
Relationship to BIONICS STUDY: The general and angiographic inclusion and exclusion criteria will be identical to the pivotal BIONICS trial with the exception of Acute Coronary Syndrome (ACS) patients who will be excluded. Clinical data will be collected in an identical manner to the BIONICS study.
(Clinical follow-up will be performed at 30 days, 6 months, and 1, 2, 3, 4, and 5 years post enrollment.) The following pharmacokinetic parameters will be evaluated: maximum concentration (Cmax), Cmax adjusted by treatment dose, time to maximum concentration (tmax), the time of the last quantifiable concentration (tlast ), half-life time ( t1/2), total area under the concentration-time curve from time 0 to tlast (AUC0-tlast), total area under the concentration-time curve from time 0 to tlast (AUC0-t∞) and total body clearance (CL). AUCs normalized by treatment dose will also be derived.
12 subjects will be enrolled in order to evaluate the pharmacokinetic parameters of ridaforolimus release from the BioNIR stent. The number of subjects was chosen based on experience in the literature from other 'limus' drug eluting stents as well as specific request from FDA.
Study design
- Observational model
- Cohort
- Time perspective
- Prospective
- Number of arms
- 1
| Arm | Type | Receives |
|---|---|---|
| BioNIR Ridaforolimus (drug eluting stent (DES) | – | Device: BioNIR Ridaforolimus Eluting Coronary StentThe BioNIR Ridaforolimus Eluting Coronary Stent System is a single use device/drug combination product comprising: * Stent - a mounted Cobalt Chromium (CoCr) alloy based stent * Delivery System - Rapid Exchange (RX) Coronary System * Polymer matrix coating - Poly n-butyl methacrylate (PBMA) and CarboSil® * Ridaforolimus drug - CAS Registry Number: 572924-54-0 The drug Ridaforolimus is utilized on the stent system at a dose of 1.1 μg/mm2 (with a drug load of 100 μg per 2.75/3.00 x 17 mm stent). |
Who may qualify
- Ages
- 18 years and older
- Sex
- All
- Healthy volunteers
- Not accepted
- Age groups
- Adult, Older adult
- Study population
- Subjects with an indication for percutaneous coronary intervention (PCI) with stent implantation for stable angina and/or silent ischemia.
Eligibility is decided by the study team after screening; this overview does not establish that a patient qualifies. Full inclusion and exclusion criteria.
Interventions
| Intervention | Type | Arms |
|---|---|---|
| BioNIR Ridaforolimus Eluting Coronary Stent | Device | BioNIR Ridaforolimus (drug eluting stent (DES) |
Primary outcome
Maximum concentration (Cmax)
Time frame: For each patient, a total of up to 14 blood samples will be collected at the following time points: immediately prior to the first stent implant as time 0, at 10 and 30 minutes, and at 1, 2, 4, 8, 12, 24±6, 48±12, 72±12, 168±36 hours.
Maximum concentration (Cmax)
Results and safety
The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.
Research links
- Official record on ClinicalTrials.govLast updated by the sponsor 13 Apr 2022.
- Individual participant dataSharing planned: No
Related trials for Heart Disease
Not yet recruitingPhase 4
An Investigator-initiated, Prospective, Open-label, Multicenter Randomized Controlled Trial, Comparing the Efficacy of Sacubitril/Valsartan and Standard Treatment on Atrial Fibrillation Recurrence After Catheter Ablation in Persistent Atrial Fibrillation Patients Without Hypertensive
Atrial Fibrillation (Persistent), Catheter Ablation
Not yet recruiting
LBBAP Versus ILR in Patients With New-Onset LBBB and Moderately Reduced LVEF After TAVI
TAVI(Transcatheter Aortic Valve Implantation), Left Bundle Branch Block
Recruiting
Tricuspid Regurgitation Treatment With LAPLACE Transcatheter Tricuspid Valve Replacement System
Severe Tricuspid Valve Regurgitation, Tricuspid Valve Regurgitation
Recruiting
Pivotal Study of the SUpira System in Patients Undergoing High-Risk Percutaneous COronaRy InTervention (HRPCI)
Coronary Artery Disease, High Risk Percutaneous Coronary Intervention
Not yet recruitingObservational study
NHLBI-Emory Advanced Cardiac CT Reconstruction
Structural Heart Disease
Referral and contact
AzTrials does not enrol participants or take referrals. Contact the study team or a site listed below; they decide who can take part. This study is not recruiting at the moment.
David Rizik, MD principal investigator
Scottsdale Heart Group
2 sites in 1 country: see every site and its status.
Questions about this trial
What is this clinical trial studying?
An observational study of Heart Disease, run by Medinol Ltd. at 2 sites in United States.
The full registered description is in the About this study section and the official record.
Who may be eligible to take part?
Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.
Is this clinical trial currently recruiting?
The record says: finished, as of the sponsor's last update on 13 Apr 2022. Status can change between updates, so confirm with the study contact before making plans.
Where is the study taking place?
The record lists 2 sites in United States. Whether a site is taking part right now should be confirmed with that site. See every site.
What are the possible benefits and risks?
They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.
Are results available for this study?
The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.
How can a doctor refer a patient or contact the research team?
The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.
What does the primary outcome measure?
Maximum concentration (Cmax) (time frame: For each patient, a total of up to 14 blood samples will be collected at the following time points: immediately prior to the first stent implant as time 0, at 10 and 30 minutes, and at 1, 2, 4, 8, 12, 24±6, 48±12, 72±12, 168±36 hours.). It is what the study was designed to measure, not a finding.
Where can I read the original study information?
Does a listing mean the treatment is approved or proven to work?
No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.
How often is this information updated?
AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 13 Apr 2022.