Premature BirthHLPulseSNCT02747069
HeartLight Pulse Study: Evaluation of Heart Rate Using an Electronic Stethoscope and Pre Placed ECG in the Delivery Room
An observational study of Premature Birth, run by University of Nottingham at 1 site in United Kingdom.
Trial summary
This study will evaluate the accuracy of both an electronic stethoscope and electrocardiogram (ECG) to evaluate heart rate in neonatal patients in the delivery suite. The initial phase of this study will assess the electronic stethoscope use on stable neonates on the neonatal care prior to use in the delivery room. Read more about this study
- Who is it for?
- Ages Up to 4 months
- Conditions the study is for
- Premature Birth
- What is being tested?
- NICU electronic stethoscope and Newborns <32 weeks and ECG
- Type of treatment
- Medical device
- How many people
- 50 participants
- Where
- 1 siteUnited Kingdom
- Study dates
- May 2016to Dec 2018
- Phase
- Observational
- Are there results?
- None posted in the registry
Key requirements
Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.
- Ages Up to 4 months
- All sexes
- No healthy volunteers
- Child
Study population: Phase 1- neonates of any gestation admitted to NICU with routine ECG and pulse oximetry monitoring
Who may be able to join
- All must have written informed consent from the participant's mother
- Phase 1: Any neonate requiring NICU admission and routine monitoring with ECG.
- Phase 2: Preterm infants ≤32 weeks gestation delivered into a plastic bag/wrap
Who cannot join
- Phase 1: Infants undergoing comfort care (palliative care). Infants deemed too sick, as assessed by the clinical team caring for them, to tolerate additional procedures. This is unusual but would normally include infants who become more unstable with increased handling
- Phase 2: Infants >32 weeks gestation Infants where resuscitation is unlikely to be instigated (eg. known lethal condition)
Trial locations and contacts
1 site in 1 country.
United Kingdom1 site
University of Nottingham NHS Trust
Nottingham, NG72UH
About this study
Official title: Determination of Heart Rate in Neonates on the NICU and Delivery Suite Using ECG and Electronic Stethoscope, a Feasibility Study
This study will evaluate the accuracy of both an electronic stethoscope and electrocardiogram (ECG) to evaluate heart rate in neonatal patients in the delivery suite.
The initial phase of this study will assess the electronic stethoscope use on stable neonates on the neonatal care prior to use in the delivery room.
Read the detailed description
Up to 10% of newborns (79K/yr in United Kingdom, 13 million/yr worldwide) require some form of resuscitation at birth. It is estimated that approximately 7 million babies worldwide, especially the premature group, will require more advanced resuscitation. The correct, structured management of the resuscitation in the few 'golden' minutes after birth is critical to prevent significant morbidity (e.g. cerebral palsy due to asphyxiation) or death. There is strong evidence that standardised resuscitation training and algorithms significantly improve newborn outcomes and could reduce mortality by 30% in certain healthcare institution. International newborn resuscitation guidelines state that "a prompt increase in heart rate remains the most sensitive indicator of resuscitation efficacy" and that the stethoscope should be the primary means of assessing heart rate (HR). Provision of an accurate and timely HR value is essential if the best care outcomes are to be achieved. Establishing the HR category allows the resuscitator to decide if the HR is >100 bpm (suggests the baby is well or resuscitation is effective), between 60-100bpm (resuscitation required initially focusing on the airway) or <60bpm (requires much more intensive resuscitation which could include CPR). International guidelines recommend assessing the HR every 30 seconds with a stethoscope to track changes and hence efficacy of resuscitation. However, a number of studies demonstrate that newborn healthcare providers estimate the HR category incorrectly in about 1 in 3 cases, potentially resulting in the incorrect management of the baby. There is now strong evidence linking the need for resuscitation and a poor neurodevelopmental outcome in later childhood. Indeed, a number of large cohort studies have demonstrated that even if a baby requires initial resuscitation, and no further need for on-going care, they are at an increased risk of low intelligence quotient in childhood and are less likely to have paid employment or go to University when adults.
More recently electronic stethoscopes (ES) have been used to determine heart rate variability. Several studies have shown that an ES can reliably evaluate the heart rate in adults, but only one recently published study has demonstrated its use in the neonatal patient. The advantage of using an ES over ECG and pulse oximetry is fast acquisition of HR (<5 sec) and ease of application, both attributes are beneficial in the delivery suite scenario. Furthermore, assessment of HR by auscultation (using a stethoscope) is still the primary technique used in many settings.
ECG, an established and accurate method of monitoring HR, is rarely used in the delivery room for a number of reasons including difficulty ensuring adhesion to the skin (the baby is wet/covered in vernix) and skin damage in premature babies caused by stripping of the electrodes. Current ECG systems also require 3 electrodes to be positioned which can delay resuscitation further. To improve HR assessment at birth we aim to tackle this problem through a variety of means. ECG is not routinely used for delivery room resuscitations mainly due to the impracticalities of attaching the electrodes and setting up the system. Current NICU practice is to place the ECG electrodes onto the baby's chest. It is also possible for the electrodes to be placed on the baby's which is a method commonly adopted on the NICU. Preterm babies are routinely delivered into a plastic bags/wraps to minimise heat loss. By pre-placing the ECG electrodes onto the back of the bag/wrap with small conducting holes in, it should be possible to place the baby onto the bag and connect with the ECG electrodes with a routinely used clinical conducting gel. The baby could be placed onto them and time would be saved by not needing to stick the electrodes on individually and utilising the baby's weight to establish the electrode connections. This would avoid the need to place them individually, which is often time consuming and challenging as they don't still well to wet skin, and avoid skin stripping when removed later.
This study will initially assess the accuracy and reliability of an electronic stethoscopes to evaluate heart rate on stable patients on the neonatal unit compared to routine ECG and pulse oximetry measurements. This will allow comparison of the pre placed ECG system in the second phase of the study.
- Conditions
- Premature Birth
- Being tested
- NICU electronic stethoscope, Newborns <32 weeks and ECG
- Keywords
- Heart rate, Electronic Stethoscope, Electrocardiogram, Resuscitation
- Medical subject headings
- Premature Birth
What participants receive
What participants receive. In a randomised study each person is assigned to one group by chance.
NICU electronic stethoscopeDevice
Assessment of heart rate using the electronic stethoscope for up to 10 minutes compared to ECG and pulse oximetry devices used to monitor neonates whilst on NICU
Newborns <32 weeks and ECGDevice
The three leads from the ECG device will be pre placed onto a plastic bag prior to delivery. The pre term infant (<32 weeks) placed into the bag at the time of delivery and heart rate will be assessed for up to 30 minutes
| Study group | Role | What they receive |
|---|---|---|
| NICU electronic stethoscope | Neonatal patients of any gestation admitted to the neonatal intensive care unit (NICU) and undergoing routine monitoring with ECG and pulse oximetry Heart rate will be evaluated using an electronic stethoscope Receives: Device: NICU electronic stethoscope | |
| Newborns <32 weeks and ECG | Neonatal patients <32 weeks gestation Heart rate will be assessed at the time of delivery with both an electronic stethoscope and ECG using a pre placed lead system Receives: Device: NICU electronic stethoscope; Device: Newborns <32 weeks and ECG |
What is being measured
The primary outcome is the main question the study is designed to answer.
Heart rate
Assessment of accuracy (limits of agreement ±10bpm at 2 standard deviations) and reliability (>90% agreement +/- 10 bpm) of an electronic stethoscope to measure heart rate when compared to ECG.
Measured: 10 minutes
Reliability of Pre placed ECG leads to measure heart rate
Assess of the reliability of pre-placed ECG to measure heart rate at the time of delivery when compared to heart rate assessed by an electronic stethoscope.
Measured: 30 minutes
Secondary outcomes (2)
Accuracy of Clinical assessment of heart rate using an electronic stethoscope
Evaluation of the heart rate by the clinical team when using the electronic stethoscope by subjective counting compared to actual detection of heart rate (computed by software)
Measured: 30 minutes
Acquisition of video recorded resuscitation of newborns for clinical feedback
The resuscitation of the neonate in the delivery room will be recorded to allow alignment of data (i.e. time baby placed in bag, time electronic stethoscope used). This video will be used as a resuscitation training tool for training clinicians.
Measured: 30 minutes
Timeline
From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.
- First posted21 Apr 2016 (estimated)
- Study startMay 2016
- Primary completionDec 2018 (estimated)
- Study completionDec 2018 (estimated)
Why it stopped: New data available in public domain requires re-evaluation of protocol.
Resources
- Official record on ClinicalTrials.govThe registry entry this page is built from, with its full change history.
- Other trials for Premature BirthStudies of the same condition, open and under way.
- What the trial phases meanHow a treatment moves from first tests in people to approval.
More details
For doctors and researchers: how the study is designed, who runs it, and its registry IDs.
Study design
- Study type
- Observational
- Observational model
- Other
- Time perspective
- Prospective
- Enrolment
- 50 participants (estimated)
Sponsor and investigators
- Lead sponsor
- University of Nottingham
- Sponsor type
- University, hospital or other
- Collaborators
- Heartlight Systems Limited
- Responsible party
- Sponsor
- Investigators
- Don Sharkey, PhD, Principal investigator, University of Nottingham
IDs, dates and publications
- ClinicalTrials.gov ID
- NCT02747069
- Sponsor's protocol ID
- 15124
- Acronym
- HLPulseS
- Status last verified
- May 2018
- First submitted
- 25 Feb 2016
- Last updated
- 17 May 2018
- Results posted
- No
- Data monitoring committee
- No
- Individual data sharing
- Yes
Study at a glance
From the registry record, last updated by the sponsor on 17 May 2018. Recruitment status is as the sponsor reported it: confirm with the study team.
- Official title
- Determination of Heart Rate in Neonates on the NICU and Delivery Suite Using ECG and Electronic Stethoscope, a Feasibility Study
- ClinicalTrials.gov ID
- NCT02747069
- Acronym / sponsor ID
- HLPulseS / 15124
- Conditions
- Premature Birth
- Keywords
- Heart rate, Electronic Stethoscope, Electrocardiogram, Resuscitation
- Study type
- Observational
- Recruitment status
- SuspendedReason stopped: New data available in public domain requires re-evaluation of protocol.
- Enrolment
- 50 participants (estimated)
- Lead sponsor
- University of NottinghamUniversity, hospital or other
- Collaborators
- Heartlight Systems Limited
- Study start
- May 2016
- Primary completion
- Dec 2018 (estimated)
- Study completion
- Dec 2018 (estimated)
- First posted
- 21 Apr 2016 (estimated)
- Results
- Not posted in the source record
Clinical summary
The research question as the sponsor registered it. This describes what the study plans to test, not what it found.
This study will evaluate the accuracy of both an electronic stethoscope and electrocardiogram (ECG) to evaluate heart rate in neonatal patients in the delivery suite.
The initial phase of this study will assess the electronic stethoscope use on stable neonates on the neonatal care prior to use in the delivery room.
Detailed description
Up to 10% of newborns (79K/yr in United Kingdom, 13 million/yr worldwide) require some form of resuscitation at birth. It is estimated that approximately 7 million babies worldwide, especially the premature group, will require more advanced resuscitation. The correct, structured management of the resuscitation in the few 'golden' minutes after birth is critical to prevent significant morbidity (e.g. cerebral palsy due to asphyxiation) or death. There is strong evidence that standardised resuscitation training and algorithms significantly improve newborn outcomes and could reduce mortality by 30% in certain healthcare institution. International newborn resuscitation guidelines state that "a prompt increase in heart rate remains the most sensitive indicator of resuscitation efficacy" and that the stethoscope should be the primary means of assessing heart rate (HR). Provision of an accurate and timely HR value is essential if the best care outcomes are to be achieved. Establishing the HR category allows the resuscitator to decide if the HR is >100 bpm (suggests the baby is well or resuscitation is effective), between 60-100bpm (resuscitation required initially focusing on the airway) or <60bpm (requires much more intensive resuscitation which could include CPR). International guidelines recommend assessing the HR every 30 seconds with a stethoscope to track changes and hence efficacy of resuscitation. However, a number of studies demonstrate that newborn healthcare providers estimate the HR category incorrectly in about 1 in 3 cases, potentially resulting in the incorrect management of the baby. There is now strong evidence linking the need for resuscitation and a poor neurodevelopmental outcome in later childhood. Indeed, a number of large cohort studies have demonstrated that even if a baby requires initial resuscitation, and no further need for on-going care, they are at an increased risk of low intelligence quotient in childhood and are less likely to have paid employment or go to University when adults.
More recently electronic stethoscopes (ES) have been used to determine heart rate variability. Several studies have shown that an ES can reliably evaluate the heart rate in adults, but only one recently published study has demonstrated its use in the neonatal patient. The advantage of using an ES over ECG and pulse oximetry is fast acquisition of HR (<5 sec) and ease of application, both attributes are beneficial in the delivery suite scenario. Furthermore, assessment of HR by auscultation (using a stethoscope) is still the primary technique used in many settings.
ECG, an established and accurate method of monitoring HR, is rarely used in the delivery room for a number of reasons including difficulty ensuring adhesion to the skin (the baby is wet/covered in vernix) and skin damage in premature babies caused by stripping of the electrodes. Current ECG systems also require 3 electrodes to be positioned which can delay resuscitation further. To improve HR assessment at birth we aim to tackle this problem through a variety of means. ECG is not routinely used for delivery room resuscitations mainly due to the impracticalities of attaching the electrodes and setting up the system. Current NICU practice is to place the ECG electrodes onto the baby's chest. It is also possible for the electrodes to be placed on the baby's which is a method commonly adopted on the NICU. Preterm babies are routinely delivered into a plastic bags/wraps to minimise heat loss. By pre-placing the ECG electrodes onto the back of the bag/wrap with small conducting holes in, it should be possible to place the baby onto the bag and connect with the ECG electrodes with a routinely used clinical conducting gel. The baby could be placed onto them and time would be saved by not needing to stick the electrodes on individually and utilising the baby's weight to establish the electrode connections. This would avoid the need to place them individually, which is often time consuming and challenging as they don't still well to wet skin, and avoid skin stripping when removed later.
This study will initially assess the accuracy and reliability of an electronic stethoscopes to evaluate heart rate on stable patients on the neonatal unit compared to routine ECG and pulse oximetry measurements. This will allow comparison of the pre placed ECG system in the second phase of the study.
Study design
- Observational model
- Other
- Time perspective
- Prospective
- Number of arms
- 2
| Arm | Type | Receives |
|---|---|---|
| NICU electronic stethoscope | – | Device: NICU electronic stethoscopeNeonatal patients of any gestation admitted to the neonatal intensive care unit (NICU) and undergoing routine monitoring with ECG and pulse oximetry Heart rate will be evaluated using an electronic stethoscope |
| Newborns <32 weeks and ECG | – | Device: NICU electronic stethoscope, Device: Newborns <32 weeks and ECGNeonatal patients <32 weeks gestation Heart rate will be assessed at the time of delivery with both an electronic stethoscope and ECG using a pre placed lead system |
Who may qualify
- Ages
- Up to 4 months
- Sex
- All
- Healthy volunteers
- Not accepted
- Age groups
- Child
- Study population
- Phase 1- neonates of any gestation admitted to NICU with routine ECG and pulse oximetry monitoring
Key inclusion criteria (3 listed)
- All must have written informed consent from the participant's mother
- Phase 1: Any neonate requiring NICU admission and routine monitoring with ECG.
- Phase 2: Preterm infants ≤32 weeks gestation delivered into a plastic bag/wrap
Key exclusion criteria (2 listed)
- Phase 1: Infants undergoing comfort care (palliative care). Infants deemed too sick, as assessed by the clinical team caring for them, to tolerate additional procedures. This is unusual but would normally include infants who become more unstable with increased handling
- Phase 2: Infants >32 weeks gestation Infants where resuscitation is unlikely to be instigated (eg. known lethal condition)
Eligibility is decided by the study team after screening; this overview does not establish that a patient qualifies. Full inclusion and exclusion criteria.
Interventions
| Intervention | Type | Arms |
|---|---|---|
| NICU electronic stethoscopeAssessment of heart rate using the electronic stethoscope for up to 10 minutes compared to ECG and pulse oximetry devices used to monitor neonates whilst on NICU | Device | NICU electronic stethoscope, Newborns <32 weeks and ECG |
| Newborns <32 weeks and ECGThe three leads from the ECG device will be pre placed onto a plastic bag prior to delivery. The pre term infant (<32 weeks) placed into the bag at the time of delivery and heart rate will be assessed for up to 30 minutes | Device | Newborns <32 weeks and ECG |
Primary outcome
Heart rate
Time frame: 10 minutes
Assessment of accuracy (limits of agreement ±10bpm at 2 standard deviations) and reliability (>90% agreement +/- 10 bpm) of an electronic stethoscope to measure heart rate when compared to ECG.
Reliability of Pre placed ECG leads to measure heart rate
Time frame: 30 minutes
Assess of the reliability of pre-placed ECG to measure heart rate at the time of delivery when compared to heart rate assessed by an electronic stethoscope.
2 secondary outcomes
Accuracy of Clinical assessment of heart rate using an electronic stethoscope
Time frame: 30 minutes
Acquisition of video recorded resuscitation of newborns for clinical feedback
Time frame: 30 minutes
Results and safety
Results are not available in the source record.
Research links
- Official record on ClinicalTrials.govLast updated by the sponsor 17 May 2018.
- Individual participant dataSharing planned: Yes
Related trials for Premature Birth
Not yet recruitingPhase 3
Periodontal Disease and Small Vulnerable Newborns in Rural Nepal: A Community-based Trial
Preterm Birth, Low Birth Weight
Recruiting
The Periviable GOALS Decision Support Tool
Pregnancy Preterm, Premature Birth
Active, not recruitingPhase 4
Improving Neonatal Health Through Rapid Malaria Testing in Early Pregnancy With High-Sensitivity Diagnostics
Malaria,Falciparum, Malaria in Pregnancy
RecruitingObservational study
Gonadal Tissue Freezing for Fertility Preservation in Individuals at Risk for Ovarian Dysfunction, Premature Ovarian Insufficiency and Clinically Indicated Gonadectomy
Turner Syndrome, Post-menarcheal Adolescents
RecruitingObservational study
AI-Based Differential Diagnosis and Localization of Tachycardia Using ECG: Multicenter Registry (EP-AI ASSIST)
Tachycardia, Paroxysmal Supraventricular Tachycardia
Referral and contact
AzTrials does not enrol participants or take referrals. Contact the study team or a site listed below; they decide who can take part. This study is not recruiting at the moment.
Don Sharkey, PhD principal investigator
University of Nottingham
1 site in 1 country: see every site and its status.
Questions about this trial
What is this clinical trial studying?
An observational study of Premature Birth, run by University of Nottingham at 1 site in United Kingdom.
The full registered description is in the About this study section and the official record.
Who may be eligible to take part?
The sponsor lists 3 inclusion and 2 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.
Is this clinical trial currently recruiting?
The record says: paused, as of the sponsor's last update on 17 May 2018. Status can change between updates, so confirm with the study contact before making plans.
Where is the study taking place?
The record lists 1 site in United Kingdom. Whether a site is taking part right now should be confirmed with that site. See every site.
What are the possible benefits and risks?
They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.
Are results available for this study?
Results are not available in the source record.
How can a doctor refer a patient or contact the research team?
The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.
What does the primary outcome measure?
Heart rate (time frame: 10 minutes). The study lists 2 primary outcomes in all. It is what the study was designed to measure, not a finding.