AzTrials
AzTrials

Cerebrovascular CirculationNCT02748447

Automated Adjustment of Inspired Oxygen to Maintaining Regional Cerebral Oxygenation in Preterm Infants on Respiratory Support

A study testing Automated FiO2 adjustment in people with Cerebrovascular Circulation and Premature Infants, run by ASST Fatebenefratelli Sacco at 1 site in Italy.

Unknown status

Status not confirmed. The sponsor has not verified this record for over two years, so it may be out of date.

Official record
Search all trials

Trial summary

Background: fluctuation of cerebral blood flow and oxygenation in neonates who undergo intensive care is an important risk factor for risk of neurodevelopmental impairment. Near infrared spectroscopy (NIRS) allow direct measurements of cerebral tissue oxygenation. Read more about this study

Who is it for?
Ages 72 hours to 7 days
What is being tested?
Automated FiO2 adjustment
Type of treatment
Medical device
Could I receive a placebo?
No, everyone receives an active treatment
How many people
60 participants
Where
1 siteItaly
Study dates
Apr 2016to Jul 2017
Phase
Interventional
Are there results?
None posted in the registry

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 72 hours to 7 days
  • All sexes
  • No healthy volunteers
  • Child

Who may be able to join

  • preterm infants of 25+0-28+6 weeks of gestational age, requiring invasive or non invasive respiratory support and supplemental oxygen

Who cannot join

  • infants with major congenital anomalies, haemodinamic instability, or requiring cathecolamines treatment,clinical evidence of seizures or ongoing sepsis (positive blood culture) during the study, or within 24 hours prior enrollment

Trial locations and contacts

1 site in 1 country.

Ilaria Stucchi, MF contact

00393358050962

stucchi.ilaria@icp.mi.it

Italy1 site, 1 recruiting
  • V. Buzzi Childrens's Hospital - ASST FBF-SACCO

    Milan, 20154

    Ilaria Stucchi, MD, 00390257995341, ilaria.stucchi@asst-fbf-sacco.it

    Recruiting

Other trials in Italy

About this study

Official title: Effects of Automated Adjustment of the Inspired Oxygen in Reducing the Risk of Regional Cerebral (rSO2) Hypo-oxygenation in Preterm Infants on Non Invasive or Invasive Respiratory Support

Background: fluctuation of cerebral blood flow and oxygenation in neonates who undergo intensive care is an important risk factor for risk of neurodevelopmental impairment. Near infrared spectroscopy (NIRS) allow direct measurements of cerebral tissue oxygenation. Automated Fraction of Inspired Oxygen (FiO2) adjustment can maintain arterial oxygen saturation (SpO2) within a target range and may reduce risk of fluctuation of cerebral oxygenation.

Aim of this study: to evaluate the efficacy of automated FiO2 adjustment in maintaining SpO2 within a target range and in reducing the risk of cerebral tissue hypo-oxygenation due to SpO2 fluctuations in preterm infants on invasive or non invasive respiratory support with supplemental oxygen.

Read the detailed description

Background: fluctuation of cerebral blood flow and oxygenation in neonates who undergo intensive care is an important risk factor for risk of neurodevelopmental impairment. Near infrared spectroscopy (NIRS) allow direct measurements of cerebral tissue oxygenation. Automated FiO2 adjustment can maintain arterial oxygen saturation (SpO2) within a target range and may reduce risk of fluctuation of cerebral oxygenation.

Aim of this study: to evaluate the efficacy of automated FiO2 adjustment in maintaining SpO2 within a target range and in reducing the risk of cerebral tissue hypo-oxygenation due to SpO2 fluctuations in preterm infants on invasive or non invasive respiratory support with supplemental oxygen.

Methodology: multicenter randomized cross-over clinical trial. The study will be carried out for almost 1 year .

Study centers: 7 Italian Neonatal Intensive Care Units (NICUs) Number of subjects: 60 infants to have a >90% power, with an alpha of p=0.01, of detecting a 5% difference in %-time in the target range and a 50% difference in both SpO2 hyperoxic and hypoxic %-time.

Diagnosis and main inclusion criteria: preterm infants of 25+0-28+6 weeks of gestational age, requiring invasive or non invasive respiratory support and supplemental oxygen.

Other enrollment requirements: All infants will be enrolled between >72 hours (end of transition period) and </= 7 days. Expected to remain of the current mode of support for the 48-hour intervention period. Infants with major congenital anomalies, haemodynamic instability (patent ductus arteriosus-PDA) or requiring catecholamines treatment, clinical evidence of seizures or ongoing sepsis (positive blood culture) during the study, or within 24 hours prior of enrollment, will be excluded.

Study product:AVEA ventilator with closed-loop inspired oxygen control (CLiO2) automated FiO2 control option. An additional sensor will be attached to the infant's forehead for continuous measurement of cerebral tissue oxygen saturation (rStO2) with 5100C NIRS oximeter, Covidien.

Duration:24 hours each of manual control and CLiO2 control. Reference therapy:Manual control of FiO2 provided according to standardized guidelines.

Statistical Methodology: repeated measures mixed linear model with control from sequence and ventilation mode.

Concurrent safety oversight:Independent Data Safety Monitoring Board, with blinded review every 6 months or 50% enrollment, and after 15 subjects.

Being tested
Automated FiO2 adjustment
Medical subject headings
Premature Birth

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • Automated FiO2 adjustmentDevice

    AVEA ventilator according to SpO2 target range delivers an automated FiO2

Study groups in NCT02748447
Study groupRoleWhat they receive
A-FiO2Experimental24 hours in automated FiO2 adjustment to maintain SpO2 within a target range
Receives: Device: Automated FiO2 adjustment
M-FiO2No intervention24 hours in manual adjustment of FiO2 to maintain SpO2 within a target range

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. the burden of hypoxemia on regional cerebral saturation (rStO2) calculated as area under curve (AUC-% second) below the individual median rStO2 range ( defined as +/-5% of the individual rStO2 median of each infant during each period

    burden of hypoxemia on rStO2

    Measured: 24 hours

Secondary outcomes (1)
  1. AUC above the individual median rStO2 and time (% of the total recording time) within the SpO2 target range (91-95%)

    burden hyperoxemia

    Measured: 24 hours

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted22 Apr 2016 (estimated)
  2. Study startApr 2016
  3. Primary completionMay 2017 (estimated)
  4. Study completionJul 2017 (estimated)

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Interventional
Phase
Phase N/A
Primary purpose
Supportive care
Allocation
Randomised
Intervention model
Crossover
Masking
None (open label)
Enrolment
60 participants (estimated)
IDs, dates and publications
ClinicalTrials.gov ID
NCT02748447
Sponsor's protocol ID
PoloU
Status last verified
Apr 2017
First submitted
19 Apr 2016
Last updated
17 Apr 2017
Results posted
No

Publications

  • Kurth CD, McCann JC, Wu J, Miles L, Loepke AW. Cerebral oxygen saturation-time threshold for hypoxic-ischemic injury in piglets. Anesth Analg. 2009 Apr;108(4):1268-77. doi: 10.1213/ane.0b013e318196ac8e.

    PubMed 19299799
  • Laptook AR, Salhab W, Allen J, Saha S, Walsh M. Pulse oximetry in very low birth weight infants: can oxygen saturation be maintained in the desired range? J Perinatol. 2006 Jun;26(6):337-41. doi: 10.1038/sj.jp.7211500.

    PubMed 16598294
  • Claure N, D'Ugard C, Bancalari E. Automated adjustment of inspired oxygen in preterm infants with frequent fluctuations in oxygenation: a pilot clinical trial. J Pediatr. 2009 Nov;155(5):640-5.e1-2. doi: 10.1016/j.jpeds.2009.04.057.

    PubMed 19595375
  • van Kaam AH, Hummler HD, Wilinska M, Swietlinski J, Lal MK, te Pas AB, Lista G, Gupta S, Fajardo CA, Onland W, Waitz M, Warakomska M, Cavigioli F, Bancalari E, Claure N, Bachman TE. Automated versus Manual Oxygen Control with Different Saturation Targets and Modes of Respiratory Support in Preterm Infants. J Pediatr. 2015 Sep;167(3):545-50.e1-2. doi: 10.1016/j.jpeds.2015.06.012. Epub 2015 Jul 2.

    PubMed 26144575

Questions about this trial

What is this clinical trial studying?

A study testing Automated FiO2 adjustment in people with Cerebrovascular Circulation and Premature Infants, run by ASST Fatebenefratelli Sacco at 1 site in Italy.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 1 inclusion and 1 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: status not confirmed, as of the sponsor's last update on 17 Apr 2017. Status can change between updates, so confirm with the study contact before making plans.

Where is the study taking place?

The record lists 1 site in Italy. Whether a site is taking part right now should be confirmed with that site. See every site.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

Results are not available in the source record.

How can a doctor refer a patient or contact the research team?

Contact Ilaria Stucchi, MF (00393358050962, stucchi.ilaria@icp.mi.it), or a site near the patient. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

the burden of hypoxemia on regional cerebral saturation (rStO2) calculated as area under curve (AUC-% second) below the individual median rStO2 range ( defined as +/-5% of the individual rStO2 median of each infant during each period (time frame: 24 hours). It is what the study was designed to measure, not a finding.

Where can I read the original study information?

On the ClinicalTrials.gov record for NCT02748447, which also lists 4 linked publications.

Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 17 Apr 2017.

Free account

Log in to keep searching

You’ve used your 3 free searches. AzTrials is free: log in or create a free account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in