Labor PainNCT02762149

The Response Patterns to the Electrical Stimulation of Epidural Catheters With Varying Pulse Widths in Term Pregnant Women

A study testing Nerve stimulator in people with Labor Pain, run by Samuel Lunenfeld Research Institute, Mount Sinai Hospital at 1 site in Canada.

Terminated

Stopped early. The study ended before it was planned to and will not resume.

Official record
Search all trials

Trial summary

Epidural analgesia is commonly used for labor pain relief due to its safety and effectiveness. Despite a very high success rate, the epidural technique remains a somewhat blind technique and failures continue to occur. Read more about this study

Who is it for?
Ages 16 to 55 years, women onlyHealthy volunteers can take part
Conditions the study is for
Labor Pain
What is being tested?
Nerve stimulator
Type of treatment
Medical device
Could I receive a placebo?
No, everyone receives an active treatment
How many people
20 participants
Where
1 siteCanada
Study dates
May 2016to Aug 2016
Phase
Interventional
Are there results?
None posted in the registry

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 16 to 55 years
  • Women only
  • Healthy volunteers accepted
  • Child, Adult

Who may be able to join

  • Women 16 years of age and older requesting an epidural for labour analgesia
  • Ability to communicate in English
  • Informed consent

Who cannot join

  • Refusal to provide written informed consent
  • Inability to communicate in English
  • Abnormal vertebral anatomy, including but not limited to previous spine surgery and scoliosis
  • Allergy or hypersensitivity to lidocaine, bupivacaine or fentanyl
  • Coexisting neurological disorders
  • Implanted electronic devices

Trial locations and contacts

1 site in 1 country.

Canada1 site
  • Mount Sinai Hospital

    Toronto, Ontario, M5G1X5

Other trials in Canada

About this study

Epidural analgesia is commonly used for labor pain relief due to its safety and effectiveness. Despite a very high success rate, the epidural technique remains a somewhat blind technique and failures continue to occur. Unfortunately, there are no imaging techniques that can be used at the bedside to determine the proper positioning of the epidural catheter. The trans-catheter electric stimulation test (TCEST) has been successfully used for this purpose. This test is occasionally performed in situations where the immediate confirmation of the proper epidural catheter location is deemed necessary. The test helps to predict which epidurals might fail so that appropriate measures could be immediately implemented.

There has been one duration of electrical stimulus (0.2 milliseconds) that has been used in the majority of studies and in clinical practice. With this duration of stimulation, the vast majority of cases show a unilateral motor response of the lower limbs during the TCEST. Studies on the stimulation of peripheral nerves (nerves in the arms and legs) have shown that an electrical stimulus with a longer duration is able to stimulate nerves which are farther away. Since nerves in the epidural space are similar in composition to peripheral nerves, the investigators expect to see a higher rate of bilateral response with the longer duration of stimulus. The investigators also hope to show that this bilateral response is predictive of a better functioning epidural.

The investigators hypothesize that the incidence of a bilateral response to the TCEST will be higher with the 1.0 ms pulse width compared to 0.1 ms pulse width. Furthermore, the investigators hypothesize that a bilateral motor response associated with the 1.0 ms pulse width will be predictive of symmetry of sensory and motor block and of lower consumption of local anesthetic.

Read the detailed description

This will be a randomized double-blind controlled study. After recruitment of the patient, epidural anesthesia will be performed in the standard fashion employed in the investigators' institution by a fellow or staff. Spinal ultrasound will be used prior to performing the epidural catheter insertion. The trans-catheter electric stimulation test (TCEST) will be performed at both a 0.1ms pulse width and a 1ms pulse width. The order in which the two pulse widths are applied will be randomly decided by computer. The test dose of local anesthetic will then be administered, and the TCEST will be repeated 5 minutes later. Again, both pulse widths (0.1ms, 1ms) will be used, and the order in which they are applied will be decided randomly.

Following the second testing, a loading dose of the standard anesthetic solution will be administered. The sensory level to ice will be tested at 20 minutes following injection of the loading dose of bupivacaine and fentanyl. The sensory level will be assessed from the sacral to the thoracic levels, bilaterally. The motor response pattern will be recorded for all TCESTs performed, and any relationship between pulse width and response pattern will be determined.

Conditions
Labor Pain
Being tested
Nerve stimulator
Keywords
Tsui Test, Labour, Epidural catheter
Medical subject headings
Labor Pain

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • Nerve stimulatorDevice

    Also called Stimpod NMS 450

    The nerve stimulator (Stimpod NMS 450: Xavant technology (PTY) Ltd; Pretoria, South Africa or similar nerve stimulator) will be connected to the epidural catheter through an adapter (Johans ECG Adapter, Arrow International Inc., Reading). The epidural catheter and the adapter will be primed with a standard volume of 3 ml of sterile normal saline to allow for effective electrical conduction. Secured connections and avoidance of any air within in the system must be ensured to avoid high impedance in the circuit, which could result in false negatives. The cathode terminal of the stimulator will then be attached to the metal hub of the adapter and the anode terminal will be connected to the electrode placed over the deltoid muscle.

Study groups in NCT02762149
Study groupRoleWhat they receive
0.1ms pulse widthActive comparatorThe nerve stimulator will be connected to the epidural catheter through an adapter, which will be primed with a standard volume of 3 ml of sterile normal saline to allow for effective electrical conduction. The cathode terminal of the stimulator will then be attached to the metal hub of the adapter and the anode terminal will be connected to the electrode placed over the deltoid muscle. All patients will have the trans-catheter electric stimulation test (TCEST) performed with both a 1 ms pulse width and 0.1 ms pulse width and the order of administration will be randomized.
Receives: Device: Nerve stimulator
1ms pulse widthActive comparatorThe nerve stimulator will be connected to the epidural catheter through an adapter, which will be primed with a standard volume of 3 ml of sterile normal saline to allow for effective electrical conduction. The cathode terminal of the stimulator will then be attached to the metal hub of the adapter and the anode terminal will be connected to the electrode placed over the deltoid muscle. All patients will have the trans-catheter electric stimulation test (TCEST) performed with both a 1 ms pulse width and 0.1 ms pulse width and the order of administration will be randomized.
Receives: Device: Nerve stimulator

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. Motor response pattern

    Motor response pattern to the electrical stimulation of the epidural catheter, either unilateral or bilateral.

    Measured: 5 minutes

Secondary outcomes (5)
  1. Sensory level

    The sensory level to ice at 20 minutes and 2 hours following injection of the standard epidural loading dose. The sensory level will be assessed from the sacral to the thoracic levels, bilaterally.

    Measured: 2 hours

  2. Motor block

    Lower extremity motor block as assessed by the Bromage score (Range: 0-3) bilaterally at 20 minutes and 2 hours following the loading dose.

    0 = No motor block (full flexion of knees and feet)

    1. = Partial motor block (just able to move knees and feet)
    2. = Almost complete motor block (able to move feet only)
    3. = Complete motor block (unable to move feet or knees)

    Measured: 2 hours

  3. Current (mA)

    The current required to elicit a motor response on the initial TCEST and at 5 minutes after the test dose

    Measured: 5 minutes

  4. Consumption of local anesthetic

    Amount of local anesthetic consumed as measured on the pump in the first 2 hours.

    Measured: 2 hours

  5. Epidural block failure

    Failure of the epidural analgesia, defined as no evidence of a sensory block to ice and absent pain relief in the first 20 minutes, OR the need for epidural catheter replacement within 2 hours of the loading dose.

    Measured: 2 hours

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted4 May 2016 (estimated)
  2. Study startMay 2016
  3. Primary completionAug 2016
  4. Study completionAug 2016

Why it stopped: Analysis after 20 patients was convincing for a negative result for the primary outcome, so the study was stopped.

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Interventional
Phase
Phase N/A
Primary purpose
Treatment
Allocation
Randomised
Intervention model
Parallel groups
Masking
Double blind
Who is masked
Participant, Outcomes assessor
Enrolment
20 participants (actual)
IDs, dates and publications
ClinicalTrials.gov ID
NCT02762149
Sponsor's protocol ID
16-04
Status last verified
Jul 2017
First submitted
2 May 2016
Last updated
1 Aug 2017
Results posted
No
Data monitoring committee
No
Individual data sharing
No

Publications

  • Zakus P, Bittencourt R, Downey K, Tsui BCH, Carvalho JCA. The effect of an increased pulse width on the pattern of motor response (unilateral versus bilateral) during the Tsui test in labouring parturients: a randomized crossover trial. Can J Anaesth. 2017 Dec;64(12):1211-1217. doi: 10.1007/s12630-017-0977-y. Epub 2017 Sep 21.

    PubMed 28936608

Questions about this trial

What is this clinical trial studying?

A study testing Nerve stimulator in people with Labor Pain, run by Samuel Lunenfeld Research Institute, Mount Sinai Hospital at 1 site in Canada.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 3 inclusion and 6 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: stopped early, as of the sponsor's last update on 1 Aug 2017. Status can change between updates, so confirm with the study contact before making plans.

Where is the study taking place?

The record lists 1 site in Canada. Whether a site is taking part right now should be confirmed with that site. See every site.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

The study was stopped early (reason given: Analysis after 20 patients was convincing for a negative result for the primary outcome, so the study was stopped.). Results are not available in the source record.

How can a doctor refer a patient or contact the research team?

The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

Motor response pattern (time frame: 5 minutes). It is what the study was designed to measure, not a finding.

Where can I read the original study information?

On the ClinicalTrials.gov record for NCT02762149, which also lists 1 linked publication.

Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 1 Aug 2017.

Free account

Log in to keep searching

You’ve used your 3 free searches. AzTrials is free: log in or create a free account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in