Work of BreathingNCT02782936
The Gas Mask: the Effects on Respiration!
A study testing measurement of the work of breathing and Gas mask in people with Work of Breathing, run by Laval University at 1 site in Canada.
Trial summary
Background: The gas mask is used to protect military and non-military subjects exposed to respiratory hazards (CBRN agents). The aim of the study was to evaluate the impact of the gas mask on respiratory patterns and indexes of the respiratory effort. Read more about this study
- Who is it for?
- Ages 18 years and olderHealthy volunteers can take part
- Conditions the study is for
- Work of Breathing
- What is being tested?
- measurement of the work of breathing and Gas mask
- Type of treatment
- Medical device
- Could I receive a placebo?
- No, everyone receives an active treatment
- How many people
- 15 participants
- Where
- 1 siteCanada
- Study dates
- Jun 2015to Jul 2016
- Phase
- Interventional
- Are there results?
- None posted in the registry
Key requirements
Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.
- Ages 18 years and older
- All sexes
- Healthy volunteers accepted
- Adult, Older adult
Who may be able to join
- Having no significant cardiac and respiratory pathology
- Having no history of epilepsy
- Having no severe and chronic pathology that requires medication
- Not being pregnant
- Face size: medium
Who cannot join
- Refuse to participate in the study for one of the following reasons: i. wearing a oesophageal catheter; ii. wearing the gas mask; iii. giving blood sample; iv. claustrophobia.
- Oesophageal background wounds
- Facial anthropometrical issues.
Trial locations and contacts
1 site in 1 country.
Canada1 site
Institut de recheche universitaire de cardiologie et pneumologie de Québec
Québec, Quebec, G1V4G5
About this study
Official title: Impact of Gas Masks on Index of Efforts and Breathing Pattern
Background: The gas mask is used to protect military and non-military subjects exposed to respiratory hazards (CBRN agents). The aim of the study was to evaluate the impact of the gas mask on respiratory patterns and indexes of the respiratory effort. Methods: We are completing our study with 14 healthy subjects to evaluate breathing patterns, index of respiratory efforts and blood gases. Seven conditions have been tested in a randomized order: at rest, during effort (on a tread mill, standardized at 7 METs for all subjects) and during induced hypoxemia with and without a mask (C4, Airboss Defence, Bromont, Canada). Airway pressure, inspiratory and expiratory flows were measured. An esophageal catheter was introduced at the beginning of the study to measure esophageal pressure (Peso) and calculate indexes of respiratory effort (PTPeso, WOB). SpO2 was continuously measured and capillary blood bases were drawn at the end of each condition. Each condition lasted 10 minutes, data of the last 2 minutes at a steady state were considered for analyses. Results: The preliminary analyses based on 10 subjects are presented here. Comparing the wearing of the gas mask and without, most of the respiratory index increased in the tested conditions (at rest, during induced hypoxemia and during effort). At rest, in 8 out of 10 healthy subject the indexes of effort were higher with the gas mask, a statistical trend was observed with the WOB (0.22±0.13 vs. 0.28±0.10 J/cycle; p = 0.059), the PTPes (101±35 vs. 122±47 cmH2O*s; p=0.21) and SwingPeso (4.4±2.0 vs. 5.3±2.0 cmH2O; p=0.13). During the effort, the respiratory index increased (WOB 4.0±2.6 vs. 5.6±3.2; p=0.10; PTPeso 406±211 vs. 606±65; p=0.04; SwingPeso 14.8±8.1 vs. 21.8±9.0; p=0.13). There was no difference for the breathing pattern and arterial blood gases data with and without mask. Data for induced hypoxemia are under analysis. We measured on bench the inspiratory and expiratory resistances of the tested gas mask (C4: inspiratory resistances = 3.2 cmH2O at 1 L/sec; expiratory resistances = 0.9 cmH2O at 1 L/sec). This may explain in part the increased work of breathing with masks. Conclusions: This study demonstrated an increase of the indexes of respiratory effort during an exercise with the gas mask. This study is the first to directly assess the indexes of efforts with esophageal pressure in this situation. Our results and method may be used as a reference for evaluating tolerance with different designs of gas masks.
Read the detailed description
The principal way of penetration of CBRNE agents is the respiratory system. The current technology of a gas mask has been used to protect the respiratory system as far back as the First World War. That originated from Dr Cluny Macpherson's initiatives whom was a Canadian military physician.
The military gas mask is part of the respirator classification but owes its specific features. Conventionally, the military gas mask covers a large spectrum of protection aspects and matched with their specific canisters. Consequently, gas masks are usually studied separately from other respirators and Self-Contained Breathing Apparatus (SBCA).
The gas mask design and its components may lead to these respiratory load issues. At rest and effort, what would be the impacts for the work of breathing and gas exchange? In order to avoid hypoxemia and hyperoxia, what would be the optimal means to restore proper oxygenation? We hypothesised: i. on a heightened WOB and the respiratory demands related to wear of the gas mask; ii. An occurrence of hypoxemia will be manifesting during a continuous period at both at rest and effort.
Our goal was to measure the impact of the work of breathing and the gas exchange for a gas mask user. We also measured what was the optimal means for correcting the hypoxemia with a subject.
14 Male Human Subjects participated in a comparison and single-blind randomized experimental study. That was approved by the Ethical Review Committee. All male subjects were in averaged age of 38.9±5 year old and a FEV1 4.60±0.70 Liter. A written consent was obtained for all the subjects prior their acceptance. No rejection happened during the recruiting. The eligibility criteria were: i. No significant cardiac and respiratory diseases known; ii. No epilepsy background; iii. No severe pathology requiring medication; iv. No pregnancy for woman; v. Face medium - size in relation of the gas mask. The exclusion criteria were: i. Refusals relate to wear the oesophageal catheter and for capillary punctures; ii. Claustrophobia; iii. Oesophageal wounds backgrounds; iv. No coronary background and stroke history; v. No face morphology incompatibility with the mask. Spirometry and usual health screening was also done before starting the clinical trial.
Design comprised seven 10-minute testing conditions split in two parts. Five were at rest and sitting on a chair: i. Baseline without gas mask; ii. Baseline with gas mask; iii. Hypoxemia without mask; iv. Hypoxemia with gas mask; and v. Hypoxemia corrected. Two effort conditions were programmed at 7 METS Effort Zone and were performed on Treadmill (Constant 3 MPH speed and 10% inclination). These were with and without the gas mask. Between the rest-condition a 5-minute wash-out took place while for the effort a ten-minute was applied.
Three five-minute periods was followed to record blood pressure and pulse during the conditions. SpO2 was continuously measured with Free O2 during condition while the Massimo was employed also at the beginning both the inclusion and at the each three hypoxemia condition (Radical - Signal Extraction Pulse Oximeter). During effort, they were taken at each two-minute, starting at a zero starting point. Capillary punctures were done at the end of each condition.
Our main measurements were the WOB performed with a continuous recording of Peso pressure and respiratory volumes. Software Acknowledge, version 3.9 served as acquisition data system and analysis were achieved with a 4.2 version and a free-trial WOB calculus system, named RESPMAT. That was obtained from Maynaud and al. [2]. As power source, we used a BIOPAC (MP100, Santa Barbara, Californie, USA, 200 Hertz), four differential sensors (Validyne : 1x MP45±100 cmH2O; 2x MP??±5 cmH2O; 1x MP100±100 cmH2O) and four Carrier D-Modulators (Validyne, CT-15,120 Volt, 60 Hertz, 5Watts, Model CD15-A-2-A-1).
Single esophageal catheter (Type Cooper, French caliber #5) and disposable pneumotachs were used. Lidocain spray and K-Y gel were applied during the insertion of the catheter. Its placement was done at 37.6±5.7 cm across the subject and a Mueller test was performed for each subject. In regard of spontaneous breathing, an Hudson mask was used while a C-4 Gas Mask with a canister was employed (Manufacturer: Airboss Defence, Bromont, Canada). Hypoxemia mixture was home-design with usual nitrous and medical gas and maintaining a FiO2 target at 14%. Prototyped Free O2 System was employed for the correction of the hypoxemia.
- Conditions
- Work of Breathing
- Being tested
- measurement of the work of breathing, Gas mask
- Keywords
- Work of Breathing; Hypoxemia; Respiratory Acidosis; Respiratory effort
- Medical subject headings
- Hypoxia, Acidosis, Respiratory
What participants receive
What participants receive. In a randomised study each person is assigned to one group by chance.
measurement of the work of breathingOther
We have been evaluating breathing patterns, index of respiratory efforts and blood gases in all randomized conditions. A gas mask has been used mask (C4, Airboss Defence, Bromont, Canada).
Airway pressure, inspiratory and expiratory flows have been measured. An esophageal catheter has been introduced at the beginning of the study to measure esophageal pressure (Peso) and calculate indexes of respiratory effort (PTPeso, WOB). SpO2 has been continuously measured and capillary blood bases were drawn at the end of each condition. Each condition lasted 10 minutes, data of the last 2 minutes at a steady state has been considered for analyses.
Gas maskDevice
Also called Canadian Gas Mask C-4 manufactured by Airboss Defence, Bromont, Québec, Canada.
During the conditions that involved a gas mask, the measurement of the work of breathing is achieved with a oesophageal catheter and two disposable pneumotachs. While the oesophageal catheter has been fixed to the mandibular with an hypo-allergic tape, the two pneumotachs are hooked respectively on the canister and exhalation port of the gas mask. Investigators have induced the hypoxemia with a mixture nitreous and medical gas in a plastic bag that has been setted up to the canister. The FiO2 level has been kept to 14 percent.
| Study group | Role | What they receive |
|---|---|---|
| Baseline | Experimental | Randomised baseline without and with gas mask. Receives: Other: measurement of the work of breathing; Device: Gas mask |
| Induced Hypoxemia | Experimental | Randomised hypoxemia: i. without gas mask; ii. with gas mask; and iii. correction with FreeO2 and gas mask. Receives: Other: measurement of the work of breathing; Device: Gas mask |
| Effort | Experimental | Randomised effort without and with gas mask Receives: Other: measurement of the work of breathing; Device: Gas mask |
What is being measured
The primary outcome is the main question the study is designed to answer.
indexes of respiratory effort
In this study, we speculate the work of breathing is increasing with the use of a gas mask at rest, under hypoxemia condition and during physical effort.
Measured: 10 minutes
Timeline
From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.
- First posted26 May 2016 (estimated)
- Study startJun 2015
- Primary completionJul 2016
- Study completionJul 2016
Resources
- Official record on ClinicalTrials.govThe registry entry this page is built from, with its full change history.
- Publications (2)Papers the sponsor has linked to this study.
- Other trials for Work of BreathingStudies of the same condition, open and under way.
- More trials run by Laval UniversityThe sponsor's other registered studies.
- What the trial phases meanHow a treatment moves from first tests in people to approval.
More details
For doctors and researchers: how the study is designed, who runs it, and its registry IDs.
Study design
- Study type
- Interventional
- Phase
- Phase N/A
- Primary purpose
- Health services research
- Allocation
- Randomised
- Intervention model
- Single group
- Masking
- Double blind
- Who is masked
- Participant, Investigator
- Enrolment
- 15 participants (actual)
Sponsor and investigators
- Lead sponsor
- Laval University
- Sponsor type
- University, hospital or other
- Collaborators
- Pierre-Alexandre Bouchard, RT., Captain (Ret) Stephane Bourassa, RN.
- Responsible party
- Principal investigator, François Lellouche, Laval University
- Investigators
- Francois Lellouche, Doctorate, Principal investigator, Institut de Recherche Universitaire de Cardiologie et Pneumologie de Québec
IDs, dates and publications
- ClinicalTrials.gov ID
- NCT02782936
- Sponsor's protocol ID
- 21140
- Other IDs
- 2015-2448
- Status last verified
- Sep 2016
- First submitted
- 19 May 2016
- Last updated
- 29 Sep 2016
- Results posted
- No
- Data monitoring committee
- No
- Individual data sharing
- Undecided
Publications
Bourassa S, Bouchard PA, Dauphin M, Lellouche F. Oxygen Conservation Methods With Automated Titration. Respir Care. 2020 Oct;65(10):1433-1442. doi: 10.4187/respcare.07240. Epub 2020 Feb 18.
PubMed 32071135Bourassa S, Bouchard PA, Lellouche F. Impact of Gas Masks on Work of Breathing, Breathing Patterns, and Gas Exchange in Healthy Subjects. Respir Care. 2018 Nov;63(11):1350-1359. doi: 10.4187/respcare.06027. Epub 2018 Jul 31.
PubMed 30065082
Study at a glance
From the registry record, last updated by the sponsor on 29 Sep 2016. Recruitment status is as the sponsor reported it: confirm with the study team.
- Official title
- Impact of Gas Masks on Index of Efforts and Breathing Pattern
- ClinicalTrials.gov ID
- NCT02782936
- Acronym / sponsor ID
- 21140
- Conditions
- Work of Breathing
- Keywords
- Work of Breathing; Hypoxemia; Respiratory Acidosis; Respiratory effort
- Study type
- Interventional
- Recruitment status
- Completed
- Enrolment
- 15 participants (actual)
- Lead sponsor
- Laval UniversityUniversity, hospital or other
- Collaborators
- Pierre-Alexandre Bouchard, RT., Captain (Ret) Stephane Bourassa, RN.
- Study start
- Jun 2015
- Primary completion
- Jul 2016 (actual)
- Study completion
- Jul 2016 (actual)
- First posted
- 26 May 2016 (estimated)
- Results
- Not posted in the source record
Clinical summary
The research question as the sponsor registered it. This describes what the study plans to test, not what it found.
Background: The gas mask is used to protect military and non-military subjects exposed to respiratory hazards (CBRN agents). The aim of the study was to evaluate the impact of the gas mask on respiratory patterns and indexes of the respiratory effort. Methods: We are completing our study with 14 healthy subjects to evaluate breathing patterns, index of respiratory efforts and blood gases. Seven conditions have been tested in a randomized order: at rest, during effort (on a tread mill, standardized at 7 METs for all subjects) and during induced hypoxemia with and without a mask (C4, Airboss Defence, Bromont, Canada). Airway pressure, inspiratory and expiratory flows were measured. An esophageal catheter was introduced at the beginning of the study to measure esophageal pressure (Peso) and calculate indexes of respiratory effort (PTPeso, WOB). SpO2 was continuously measured and capillary blood bases were drawn at the end of each condition. Each condition lasted 10 minutes, data of the last 2 minutes at a steady state were considered for analyses. Results: The preliminary analyses based on 10 subjects are presented here. Comparing the wearing of the gas mask and without, most of the respiratory index increased in the tested conditions (at rest, during induced hypoxemia and during effort). At rest, in 8 out of 10 healthy subject the indexes of effort were higher with the gas mask, a statistical trend was observed with the WOB (0.22±0.13 vs. 0.28±0.10 J/cycle; p = 0.059), the PTPes (101±35 vs. 122±47 cmH2O*s; p=0.21) and SwingPeso (4.4±2.0 vs. 5.3±2.0 cmH2O; p=0.13). During the effort, the respiratory index increased (WOB 4.0±2.6 vs. 5.6±3.2; p=0.10; PTPeso 406±211 vs. 606±65; p=0.04; SwingPeso 14.8±8.1 vs. 21.8±9.0; p=0.13). There was no difference for the breathing pattern and arterial blood gases data with and without mask. Data for induced hypoxemia are under analysis. We measured on bench the inspiratory and expiratory resistances of the tested gas mask (C4: inspiratory resistances = 3.2 cmH2O at 1 L/sec; expiratory resistances = 0.9 cmH2O at 1 L/sec). This may explain in part the increased work of breathing with masks. Conclusions: This study demonstrated an increase of the indexes of respiratory effort during an exercise with the gas mask. This study is the first to directly assess the indexes of efforts with esophageal pressure in this situation. Our results and method may be used as a reference for evaluating tolerance with different designs of gas masks.
Detailed description
The principal way of penetration of CBRNE agents is the respiratory system. The current technology of a gas mask has been used to protect the respiratory system as far back as the First World War. That originated from Dr Cluny Macpherson's initiatives whom was a Canadian military physician.
The military gas mask is part of the respirator classification but owes its specific features. Conventionally, the military gas mask covers a large spectrum of protection aspects and matched with their specific canisters. Consequently, gas masks are usually studied separately from other respirators and Self-Contained Breathing Apparatus (SBCA).
The gas mask design and its components may lead to these respiratory load issues. At rest and effort, what would be the impacts for the work of breathing and gas exchange? In order to avoid hypoxemia and hyperoxia, what would be the optimal means to restore proper oxygenation? We hypothesised: i. on a heightened WOB and the respiratory demands related to wear of the gas mask; ii. An occurrence of hypoxemia will be manifesting during a continuous period at both at rest and effort.
Our goal was to measure the impact of the work of breathing and the gas exchange for a gas mask user. We also measured what was the optimal means for correcting the hypoxemia with a subject.
14 Male Human Subjects participated in a comparison and single-blind randomized experimental study. That was approved by the Ethical Review Committee. All male subjects were in averaged age of 38.9±5 year old and a FEV1 4.60±0.70 Liter. A written consent was obtained for all the subjects prior their acceptance. No rejection happened during the recruiting. The eligibility criteria were: i. No significant cardiac and respiratory diseases known; ii. No epilepsy background; iii. No severe pathology requiring medication; iv. No pregnancy for woman; v. Face medium - size in relation of the gas mask. The exclusion criteria were: i. Refusals relate to wear the oesophageal catheter and for capillary punctures; ii. Claustrophobia; iii. Oesophageal wounds backgrounds; iv. No coronary background and stroke history; v. No face morphology incompatibility with the mask. Spirometry and usual health screening was also done before starting the clinical trial.
Design comprised seven 10-minute testing conditions split in two parts. Five were at rest and sitting on a chair: i. Baseline without gas mask; ii. Baseline with gas mask; iii. Hypoxemia without mask; iv. Hypoxemia with gas mask; and v. Hypoxemia corrected. Two effort conditions were programmed at 7 METS Effort Zone and were performed on Treadmill (Constant 3 MPH speed and 10% inclination). These were with and without the gas mask. Between the rest-condition a 5-minute wash-out took place while for the effort a ten-minute was applied.
Three five-minute periods was followed to record blood pressure and pulse during the conditions. SpO2 was continuously measured with Free O2 during condition while the Massimo was employed also at the beginning both the inclusion and at the each three hypoxemia condition (Radical - Signal Extraction Pulse Oximeter). During effort, they were taken at each two-minute, starting at a zero starting point. Capillary punctures were done at the end of each condition.
Our main measurements were the WOB performed with a continuous recording of Peso pressure and respiratory volumes. Software Acknowledge, version 3.9 served as acquisition data system and analysis were achieved with a 4.2 version and a free-trial WOB calculus system, named RESPMAT. That was obtained from Maynaud and al. [2]. As power source, we used a BIOPAC (MP100, Santa Barbara, Californie, USA, 200 Hertz), four differential sensors (Validyne : 1x MP45±100 cmH2O; 2x MP??±5 cmH2O; 1x MP100±100 cmH2O) and four Carrier D-Modulators (Validyne, CT-15,120 Volt, 60 Hertz, 5Watts, Model CD15-A-2-A-1).
Single esophageal catheter (Type Cooper, French caliber #5) and disposable pneumotachs were used. Lidocain spray and K-Y gel were applied during the insertion of the catheter. Its placement was done at 37.6±5.7 cm across the subject and a Mueller test was performed for each subject. In regard of spontaneous breathing, an Hudson mask was used while a C-4 Gas Mask with a canister was employed (Manufacturer: Airboss Defence, Bromont, Canada). Hypoxemia mixture was home-design with usual nitrous and medical gas and maintaining a FiO2 target at 14%. Prototyped Free O2 System was employed for the correction of the hypoxemia.
Study design
- Primary purpose
- Health services research
- Allocation
- Randomised
- Intervention model
- Single group
- Masking
- Double blind (participant, investigator)
- Number of arms
- 3
| Arm | Type | Receives |
|---|---|---|
| Baseline | Experimental | Other: measurement of the work of breathing, Device: Gas maskRandomised baseline without and with gas mask. |
| Induced Hypoxemia | Experimental | Other: measurement of the work of breathing, Device: Gas maskRandomised hypoxemia: i. without gas mask; ii. with gas mask; and iii. correction with FreeO2 and gas mask. |
| Effort | Experimental | Other: measurement of the work of breathing, Device: Gas maskRandomised effort without and with gas mask |
Who may qualify
- Ages
- 18 years and older
- Sex
- All
- Healthy volunteers
- Accepted
- Age groups
- Adult, Older adult
Key inclusion criteria (5 listed)
- Having no significant cardiac and respiratory pathology
- Having no history of epilepsy
- Having no severe and chronic pathology that requires medication
- Not being pregnant
- Face size: medium
Key exclusion criteria (3 listed)
- Refuse to participate in the study for one of the following reasons: i. wearing a oesophageal catheter; ii. wearing the gas mask; iii. giving blood sample; iv. claustrophobia.
- Oesophageal background wounds
- Facial anthropometrical issues.
Eligibility is decided by the study team after screening; this overview does not establish that a patient qualifies. Full inclusion and exclusion criteria.
Interventions
| Intervention | Type | Arms |
|---|---|---|
| measurement of the work of breathingWe have been evaluating breathing patterns, index of respiratory efforts and blood gases in all randomized conditions. A gas mask has been used mask (C4, Airboss Defence, Bromont, Canada). Airway pressure, inspiratory and expiratory flows have been measured. An esophageal catheter has been introduced at the beginning of the study to measure esophageal pressure (Peso) and calculate indexes of respiratory effort (PTPeso, WOB). SpO2 has been continuously measured and capillary blood bases were drawn at the end of each condition. Each condition lasted 10 minutes, data of the last 2 minutes at a steady state has been considered for analyses. | Other | Baseline, Effort, Induced Hypoxemia |
| Gas maskAlso: Canadian Gas Mask C-4 manufactured by Airboss Defence, Bromont, Québec, Canada.During the conditions that involved a gas mask, the measurement of the work of breathing is achieved with a oesophageal catheter and two disposable pneumotachs. While the oesophageal catheter has been fixed to the mandibular with an hypo-allergic tape, the two pneumotachs are hooked respectively on the canister and exhalation port of the gas mask. Investigators have induced the hypoxemia with a mixture nitreous and medical gas in a plastic bag that has been setted up to the canister. The FiO2 level has been kept to 14 percent. | Device | Baseline, Effort, Induced Hypoxemia |
Primary outcome
indexes of respiratory effort
Time frame: 10 minutes
In this study, we speculate the work of breathing is increasing with the use of a gas mask at rest, under hypoxemia condition and during physical effort.
Results and safety
The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.
Research links
- Official record on ClinicalTrials.govLast updated by the sponsor 29 Sep 2016.
- Derived from this study: PubMed 32071135Bourassa S, Bouchard PA, Dauphin M, Lellouche F. Oxygen Conservation Methods With Automated Titration. Respir Care. 2020 Oct;65(10):1433-1442. doi: 10.4187/respcare.07240. Epub 2020 Feb 18.
- Derived from this study: PubMed 30065082Bourassa S, Bouchard PA, Lellouche F. Impact of Gas Masks on Work of Breathing, Breathing Patterns, and Gas Exchange in Healthy Subjects. Respir Care. 2018 Nov;63(11):1350-1359. doi: 10.4187/respcare.06027. Epub 2018 Jul 31.
- Individual participant dataSharing planned: Undecided
Related trials for Work of Breathing
Not yet recruiting
nCPAP-NAVA-Backup Versus Standard nCPAP for Severe Apnea in Preterm Infants ≤28 Weeks
Apnea of Prematurity
Not yet recruitingPhase 1/2
Little Lungs Study
Invasive Mechanical Ventilation, Severe Respiratory Distress Syndrome
Not yet recruiting
The Hemodynamic Impact of High-frequency Oscillatory Ventilation and Periodic Sighs in Preterm Infants
Preterm, Respiratory Distress Syndrome in Premature Infant
Not yet recruiting
Strap To Reduce Apnea in Preterm Infants: A Randomized Crossover Trial
Apnea of Prematurity, Intermittent Hypoxemia
Not yet recruitingObservational study
Impact of Inspiratory Effort and Patient-Ventilator Interaction During the Transition Phase
Mechanically Ventilated Patients, Acute Respiratory Failure (ARF)
Referral and contact
AzTrials does not enrol participants or take referrals. Contact the study team or a site listed below; they decide who can take part. This study is not recruiting at the moment.
Francois Lellouche, Doctorate principal investigator
Institut de Recherche Universitaire de Cardiologie et Pneumologie de Québec
1 site in 1 country: see every site and its status.
Questions about this trial
What is this clinical trial studying?
A study testing measurement of the work of breathing and Gas mask in people with Work of Breathing, run by Laval University at 1 site in Canada.
The full registered description is in the About this study section and the official record.
Who may be eligible to take part?
The sponsor lists 5 inclusion and 3 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.
Is this clinical trial currently recruiting?
The record says: finished, as of the sponsor's last update on 29 Sep 2016. Status can change between updates, so confirm with the study contact before making plans.
Where is the study taking place?
The record lists 1 site in Canada. Whether a site is taking part right now should be confirmed with that site. See every site.
What are the possible benefits and risks?
They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.
Are results available for this study?
The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.
How can a doctor refer a patient or contact the research team?
The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.
What does the primary outcome measure?
indexes of respiratory effort (time frame: 10 minutes). It is what the study was designed to measure, not a finding.
Where can I read the original study information?
On the ClinicalTrials.gov record for NCT02782936, which also lists 2 linked publications.
Does a listing mean the treatment is approved or proven to work?
No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.
How often is this information updated?
AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 29 Sep 2016.