Diabetes Mellitus, Type 1Phase 2NCT02814123
Effect of Basal-Bolus Closed-Loop Co-Administration of Insulin and Pramlintide on Improving the Glycemic Control in Type 1 Diabetes
A Phase 2 study testing 24-hour inpatient intervention in people with Diabetes Mellitus, Type 1, run by McGill University at 1 site in Canada.
Trial summary
The closed-loop delivery system is composed of an insulin pump, a continuous glucose sensor and a dosing algorithm that calculates the insulin dose to infuse based on sensor readings. Read more about this study
- Who is it for?
- Ages 18 years and older
- Conditions the study is for
- Diabetes Mellitus, Type 1
- What is being tested?
- 24-hour inpatient intervention
- Type of treatment
- Injection or infusion
- Could I receive a placebo?
- No, everyone receives an active treatment
- How many people
- 28 participants
- Where
- 1 siteCanada
- Study dates
- 13 Jan 2017to 8 Jul 2018
- Phase
- Phase 2
- Are there results?
- None posted in the registry
Key requirements
Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.
- Ages 18 years and older
- All sexes
- No healthy volunteers
- Adult, Older adult
Who may be able to join
- Males and females ≥ 18 years of age.
- Clinical diagnosis of type 1 diabetes for at least 12 months. (The diagnosis of type 1 diabetes is based on the investigator's judgment; C peptide level and antibody determinations are not needed.)
- The subject will have been on insulin pump therapy for at least 6 months.
- HbA1c ≤ 10%.
Who cannot join
- Current or ≤ 1 month use of other antihyperglycemic agents (SGLT2, GLP-1, Metformin, Acarbose, etc.…).
- Severe hypoglycemic episode within one month of screening.
- Severe diabetes keto-acidosis episode within one month of screening.
- Planned or ongoing pregnancy.
- Known or suspected allergy to the study drugs.
- Gastroparesis.
Show all 12Show fewer
- Use of prokinetic drugs that stimulate gastric emptying (domperidone, cisapride, metoclopramide).
- Clinically significant nephropathy, neuropathy or retinopathy as judged by the investigator.
- Recent (< 6 months) acute macrovascular event e.g. acute coronary syndrome or cardiac surgery.
- Current use of glucocorticoid medication.
- Other serious medical illness likely to interfere with study participation or with the ability to complete the trial by the judgment of the investigator.
- Failure to comply with team's recommendations (e.g. not willing to eat meals/snacks, not willing to change pump parameters, etc.).
Trial locations and contacts
1 site in 1 country.
About this study
Official title: A Randomized, Three-way, Crossover Study to Assess the Efficacy of Fast-acting Insulin-plus-pramlintide Closed-loop Co-administration, Regular Insulin-plus-pramlintide Closed-loop Co-administration, and Fast-acting Insulin-alone Closed-loop Infusion in Regulating Glucose Levels Over a 24-hour Period in Adults With Type 1 Diabetes in Inpatient Settings.
The closed-loop delivery system is composed of an insulin pump, a continuous glucose sensor and a dosing algorithm that calculates the insulin dose to infuse based on sensor readings. Pramlintide is a drug and an analog of amylin, a hormone that is co-secreted with insulin in healthy individuals, and is deficient in people with type 1 diabetes. Co-injection of pramlintide with insulin at meal times improves glucose control in type 1 diabetes. Literature data suggests that regular insulin may better match the effect of pramlintide compared to rapid insulin in regulating post-prandial glucose levels.
The purpose of this study is to compare the effectiveness of 3 strategies to control your day-and-night glucose levels:
Read more
- rapid insulin-alone closed-loop delivery;
- rapid insulin-plus-pramlintide closed-loop delivery;
- regular insulin-plus-pramlintide closed-loop delivery.
The primary hypotheses are:
- During closed-loop control, the simultaneous basal-bolus infusion of pramlintide and fast-acting insulin improves glucose control compared to fast-acting insulin-alone infusion.
- During closed-loop control, the simultaneous basal-bolus infusion of pramlintide and regular insulin improves glucose control compared to fast-acting insulin-alone infusion.
Read the detailed description
The closed-loop delivery system is composed of an insulin pump, a continuous glucose sensor and a dosing algorithm that calculates the insulin dose to infuse based on sensor readings. Pramlintide is a drug and an analog of amylin, a hormone that is co-secreted with insulin in healthy individuals, and is deficient in people with type 1 diabetes. Co-injection of pramlintide with insulin at meal times improves glucose control in type 1 diabetes.
Literature data suggests that the pharmacodynamics of regular insulin may better match the effect of pramlintide compared to the pharmacodynamics of fast-acting insulin. Moreover, the cost of regular insulin is significantly lower than fast-acting insulin. Therefore, if a similar (or better) glucose profile can be achieved with regular insulin-plus-pramlintide compared to fast-acting insulin-plus-pramlintide, then a co-formulation employing regular insulin should be prioritized.
Therefore, in this protocol, we aim to assess the effect of the simultaneous, closed-loop, basal-bolus infusion of pramlintide with insulin at a fixed ratio in controlling glucose levels. In the first experimental arm, we propose to infuse pramlintide with fast-acting insulin. In the second experimental arm, pramlintide will be infused with regular insulin. The control arm will be fast-acting insulin-alone closed-loop system.
The aim of the study is to assess the efficacy of the simultaneous, closed-loop, basal-bolus infusion of pramlintide with fast-acting insulin at a fixed ratio and pramlintide with regular insulin at a fixed ratio in controlling glucose levels compared to fast-acting insulin-alone closed-loop infusion.
The investigators aim to conduct a randomized, three-way, crossover trial to compare the efficacy of 1) fast-acting insulin-plus-pramlintide closed-loop delivery, 2) regular insulin-plus-pramlintide closed-loop delivery, and 3) fast-acting insulin-alone closed-loop delivery in regulating glucose levels over a period of 24 hours in a study on adults in inpatient settings. Insulin (fast-acting and regular) and pramlintide are given with fixed ratio (6 µg of pramlintide for each unit of insulin).
Before each 24-hour intervention visit, the participant's insulin therapy (basal rates and insulin-to-carbohydrate ratios) will be optimized for a minimum of 10 days, with a target of 14 days.
There will be a wash-out period of 0 to 42 days between the three intervention arms (termination of 24-hr intervention and start of next optimization period).
The primary hypotheses are:
- During closed-loop control, the simultaneous basal-bolus infusion of pramlintide and fast-acting insulin improves glucose control compared to fast-acting insulin-alone infusion.
- During closed-loop control, the simultaneous basal-bolus infusion of pramlintide and regular insulin improves glucose control compared to fast-acting insulin-alone infusion.
- Conditions
- Diabetes Mellitus, Type 1
- Being tested
- 24-hour inpatient intervention
- Keywords
- Diabetes Mellitus, Type 1, Pramlintide, Artificial Pancreas, Closed-Loop System, Insulin
- Medical subject headings
- Diabetes Mellitus, Type 1, Insulin Resistance
What participants receive
What participants receive. In a randomised study each person is assigned to one group by chance.
24-hour inpatient interventionOther
Subjects will be admitted at the research facility at 7:30. A cannula will be inserted into an arm or a hand vein for blood sampling purposes. Each 24-hour intervention visit includes 3 standardized meals (8:00, 12:00, and 17:00), an evening snack (21:00) and an overnight stay. The glucose level as measured by the real time sensor will be entered manually into the computer every 10 minutes. The insulin and pramlintide pumps' infusion rates will then be changed manually based on the computer generated recommendation, while still maintaining the ratio. The computer generated recommendations are based on a predictive algorithm.
| Study group | Role | What they receive |
|---|---|---|
| Rapid Insulin-alone closed-loop delivery | Active comparator | Rapid Insulin will be delivered by subcutaneous infusion. Interventions: 24-hour inpatient intervention Drug: Rapid acting Insulin (aspart, lispro, glulisine) Receives: Other: 24-hour inpatient intervention |
| Rapid Insulin-plus-pramlintide closed-loop delivery | Experimental | Rapid insulin and pramlintide will be delivered by subcutaneous infusion using a fixed ratio (6 µg pramlintide/unit insulin).
Interventions: 24-hour inpatient intervention Drug: Rapid acting Insulin (aspart, lispro, glulisine) Drug: Pramlintide Receives: Other: 24-hour inpatient intervention |
| Regular Insulin-plus-pramlintide closed-loop delivery | Experimental | Regular insulin and pramlintide will be delivered by subcutaneous infusion using a fixed ratio (6 µg pramlintide/unit insulin).
Interventions: 24-hour inpatient intervention Drug: Regular Insulin (humulin R) Drug: Pramlintide Receives: Other: 24-hour inpatient intervention |
What is being measured
The primary outcome is the main question the study is designed to answer.
Percentage of time of plasma glucose levels spent in target range. Target range is defined to be between 3.9 and 10.0 mmol/L of fast-acting insulin-plus-pramlintide closed-loop delivery vs. fast-acting insulin-alone closed-loop delivery.
Measured: Up to 24 hours
Percentage of time of plasma glucose levels spent in target range. Target range is defined to be between 3.9 and 10.0 mmol/L of regular insulin-plus-pramlintide closed-loop delivery vs. fast-acting insulin-alone closed-loop delivery.
Measured: Up to 24 hours
Secondary outcomes (12)
Percentage of time of plasma glucose levels spent in target range, comparing fast-acting insulin-plus-pramlintide closed-loop delivery vs. regular insulin-plus-pramlintide closed-loop delivery.
Measured: Up to 24 hours
Percentage of time (8:00-8:00) of plasma glucose levels spent: a. 3.9-7.8 mmol/L; b. 3.9-10 mmol/L; c. <3.9 mmol/L; d. <3.3 mmol/L; e. <2.8 mmol/L; f. >7.8 mmol/L; g. >10 mmol/L; h. >13.9 mmol/L; i. >16.7 mmol/L
Measured: Up to 24 hours
Percentage of overnight time (23:00-8:00) of plasma glucose levels: a. 3.9-7.8 mmol/L; b. 3.9-10 mmol/L; c. <3.9 mmol/L; d. <3.3 mmol/L; e. <2.8 mmol/L; f. >7.8 mmol/L; g. >10 mmol/L; h. >13.9 mmol/L; i. >16.7 mmol/L
Measured: Up to 24 hours
Standard deviation of glucose levels as a measure of glucose variability.
Measured: Up to 24 hours
Total insulin delivery.
Measured: Up to 24 hours
Total pramlintide delivery.
Measured: Up to 24 hours
Mean plasma glucose level during: a. the overall study period; b. overnight period.
Measured: Up to 24 hours
Mean plasma insulin concentration.
Measured: Up to 24 hours
Mean plasma glucagon concentration.
Measured: Up to 24 hours
Mean plasma amylin concentration.
Measured: Up to 24 hours
Number of subjects experiencing hypoglycemia requiring oral treatment during: a. the overall study period; b. the night.
Measured: Up to 24 hours
Gastrointestinal symptoms during the treatment optimization (i.e., the minimum 10 days prior to the 24-hour closed-loop visits) and during the 24-hour closed-loop visits.
Measured: Up to 24 hours
Timeline
From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.
- First posted27 Jun 2016 (estimated)
- Study start13 Jan 2017
- Primary completion8 Jul 2018
- Study completion8 Jul 2018
Resources
- Official record on ClinicalTrials.govThe registry entry this page is built from, with its full change history.
- Publications (2)Papers the sponsor has linked to this study.
- Other trials for Diabetes Mellitus, Type 1Studies of the same condition, open and under way.
- What the trial phases meanHow a treatment moves from first tests in people to approval.
More details
For doctors and researchers: how the study is designed, who runs it, and its registry IDs.
Study design
- Study type
- Interventional
- Phase
- Phase 2
- Primary purpose
- Treatment
- Allocation
- Randomised
- Intervention model
- Crossover
- Masking
- None (open label)
- Enrolment
- 28 participants (actual)
Sponsor and investigators
- Lead sponsor
- McGill University
- Sponsor type
- University, hospital or other
- Collaborators
- Juvenile Diabetes Research Foundation
- Responsible party
- Principal investigator, Ahmad Haidar, McGill University
- Investigators
- Ahmad Haidar, Principal investigator, McGill UniversityLaurent Legault, Principal investigator, McGill University Health Centre/Research Institute of the McGill University Health Centre
IDs, dates and publications
- ClinicalTrials.gov ID
- NCT02814123
- Sponsor's protocol ID
- MAP-1
- Status last verified
- Feb 2020
- First submitted
- 22 Jun 2016
- Last updated
- 17 Feb 2020
- Results posted
- No
- Data monitoring committee
- No
- Individual data sharing
- No
Publications
Haidar A, Tsoukas MA, Bernier-Twardy S, Yale JF, Rutkowski J, Bossy A, Pytka E, El Fathi A, Strauss N, Legault L. A Novel Dual-Hormone Insulin-and-Pramlintide Artificial Pancreas for Type 1 Diabetes: A Randomized Controlled Crossover Trial. Diabetes Care. 2020 Mar;43(3):597-606. doi: 10.2337/dc19-1922. Epub 2020 Jan 23.
PubMed 31974099Tsoukas M, Rutkowski J, El-Fathi A, Yale JF, Bernier-Twardy S, Bossy A, Pytka E, Legault L, Haidar A. Accuracy of FreeStyle Libre in Adults with Type 1 Diabetes: The Effect of Sensor Age. Diabetes Technol Ther. 2020 Mar;22(3):203-207. doi: 10.1089/dia.2019.0262. Epub 2020 Jan 23.
PubMed 31613140
Study at a glance
From the registry record, last updated by the sponsor on 17 Feb 2020. Recruitment status is as the sponsor reported it: confirm with the study team.
- Official title
- A Randomized, Three-way, Crossover Study to Assess the Efficacy of Fast-acting Insulin-plus-pramlintide Closed-loop Co-administration, Regular Insulin-plus-pramlintide Closed-loop Co-administration, and Fast-acting Insulin-alone Closed-loop Infusion in Regulating Glucose Levels Over a 24-hour Period in Adults With Type 1 Diabetes in Inpatient Settings.
- ClinicalTrials.gov ID
- NCT02814123
- Acronym / sponsor ID
- MAP-1
- Conditions
- Diabetes Mellitus, Type 1
- Keywords
- Diabetes Mellitus, Type 1, Pramlintide, Artificial Pancreas, Closed-Loop System, Insulin
- Phase
- Phase 2
- Study type
- Interventional
- Recruitment status
- Completed
- Enrolment
- 28 participants (actual)
- Lead sponsor
- McGill UniversityUniversity, hospital or other
- Collaborators
- Juvenile Diabetes Research Foundation
- Study start
- 13 Jan 2017 (actual)
- Primary completion
- 8 Jul 2018 (actual)
- Study completion
- 8 Jul 2018 (actual)
- First posted
- 27 Jun 2016 (estimated)
- Results
- Not posted in the source record
Clinical summary
The research question as the sponsor registered it. This describes what the study plans to test, not what it found.
The closed-loop delivery system is composed of an insulin pump, a continuous glucose sensor and a dosing algorithm that calculates the insulin dose to infuse based on sensor readings. Pramlintide is a drug and an analog of amylin, a hormone that is co-secreted with insulin in healthy individuals, and is deficient in people with type 1 diabetes. Co-injection of pramlintide with insulin at meal times improves glucose control in type 1 diabetes. Literature data suggests that regular insulin may better match the effect of pramlintide compared to rapid insulin in regulating post-prandial glucose levels.
The purpose of this study is to compare the effectiveness of 3 strategies to control your day-and-night glucose levels:
- rapid insulin-alone closed-loop delivery;
- rapid insulin-plus-pramlintide closed-loop delivery;
- regular insulin-plus-pramlintide closed-loop delivery.
The primary hypotheses are:
- During closed-loop control, the simultaneous basal-bolus infusion of pramlintide and fast-acting insulin improves glucose control compared to fast-acting insulin-alone infusion.
- During closed-loop control, the simultaneous basal-bolus infusion of pramlintide and regular insulin improves glucose control compared to fast-acting insulin-alone infusion.
Detailed description
The closed-loop delivery system is composed of an insulin pump, a continuous glucose sensor and a dosing algorithm that calculates the insulin dose to infuse based on sensor readings. Pramlintide is a drug and an analog of amylin, a hormone that is co-secreted with insulin in healthy individuals, and is deficient in people with type 1 diabetes. Co-injection of pramlintide with insulin at meal times improves glucose control in type 1 diabetes.
Literature data suggests that the pharmacodynamics of regular insulin may better match the effect of pramlintide compared to the pharmacodynamics of fast-acting insulin. Moreover, the cost of regular insulin is significantly lower than fast-acting insulin. Therefore, if a similar (or better) glucose profile can be achieved with regular insulin-plus-pramlintide compared to fast-acting insulin-plus-pramlintide, then a co-formulation employing regular insulin should be prioritized.
Therefore, in this protocol, we aim to assess the effect of the simultaneous, closed-loop, basal-bolus infusion of pramlintide with insulin at a fixed ratio in controlling glucose levels. In the first experimental arm, we propose to infuse pramlintide with fast-acting insulin. In the second experimental arm, pramlintide will be infused with regular insulin. The control arm will be fast-acting insulin-alone closed-loop system.
The aim of the study is to assess the efficacy of the simultaneous, closed-loop, basal-bolus infusion of pramlintide with fast-acting insulin at a fixed ratio and pramlintide with regular insulin at a fixed ratio in controlling glucose levels compared to fast-acting insulin-alone closed-loop infusion.
The investigators aim to conduct a randomized, three-way, crossover trial to compare the efficacy of 1) fast-acting insulin-plus-pramlintide closed-loop delivery, 2) regular insulin-plus-pramlintide closed-loop delivery, and 3) fast-acting insulin-alone closed-loop delivery in regulating glucose levels over a period of 24 hours in a study on adults in inpatient settings. Insulin (fast-acting and regular) and pramlintide are given with fixed ratio (6 µg of pramlintide for each unit of insulin).
Before each 24-hour intervention visit, the participant's insulin therapy (basal rates and insulin-to-carbohydrate ratios) will be optimized for a minimum of 10 days, with a target of 14 days.
There will be a wash-out period of 0 to 42 days between the three intervention arms (termination of 24-hr intervention and start of next optimization period).
The primary hypotheses are:
- During closed-loop control, the simultaneous basal-bolus infusion of pramlintide and fast-acting insulin improves glucose control compared to fast-acting insulin-alone infusion.
- During closed-loop control, the simultaneous basal-bolus infusion of pramlintide and regular insulin improves glucose control compared to fast-acting insulin-alone infusion.
Study design
- Primary purpose
- Treatment
- Allocation
- Randomised
- Intervention model
- Crossover
- Masking
- None (open label)
- Number of arms
- 3
| Arm | Type | Receives |
|---|---|---|
| Rapid Insulin-alone closed-loop delivery | Active comparator | Other: 24-hour inpatient interventionRapid Insulin will be delivered by subcutaneous infusion. Interventions: 24-hour inpatient intervention Drug: Rapid acting Insulin (aspart, lispro, glulisine) |
| Rapid Insulin-plus-pramlintide closed-loop delivery | Experimental | Other: 24-hour inpatient interventionRapid insulin and pramlintide will be delivered by subcutaneous infusion using a fixed ratio (6 µg pramlintide/unit insulin). Interventions: 24-hour inpatient intervention Drug: Rapid acting Insulin (aspart, lispro, glulisine) Drug: Pramlintide |
| Regular Insulin-plus-pramlintide closed-loop delivery | Experimental | Other: 24-hour inpatient interventionRegular insulin and pramlintide will be delivered by subcutaneous infusion using a fixed ratio (6 µg pramlintide/unit insulin). Interventions: 24-hour inpatient intervention Drug: Regular Insulin (humulin R) Drug: Pramlintide |
Who may qualify
- Ages
- 18 years and older
- Sex
- All
- Healthy volunteers
- Not accepted
- Age groups
- Adult, Older adult
Key inclusion criteria (4 listed)
- Males and females ≥ 18 years of age.
- Clinical diagnosis of type 1 diabetes for at least 12 months. (The diagnosis of type 1 diabetes is based on the investigator's judgment; C peptide level and antibody determinations are not needed.)
- The subject will have been on insulin pump therapy for at least 6 months.
- HbA1c ≤ 10%.
Key exclusion criteria (12 listed)
- Current or ≤ 1 month use of other antihyperglycemic agents (SGLT2, GLP-1, Metformin, Acarbose, etc.…).
- Severe hypoglycemic episode within one month of screening.
- Severe diabetes keto-acidosis episode within one month of screening.
- Planned or ongoing pregnancy.
- Known or suspected allergy to the study drugs.
Eligibility is decided by the study team after screening; this overview does not establish that a patient qualifies. Full inclusion and exclusion criteria.
Interventions
| Intervention | Type | Arms |
|---|---|---|
| 24-hour inpatient interventionSubjects will be admitted at the research facility at 7:30. A cannula will be inserted into an arm or a hand vein for blood sampling purposes. Each 24-hour intervention visit includes 3 standardized meals (8:00, 12:00, and 17:00), an evening snack (21:00) and an overnight stay. The glucose level as measured by the real time sensor will be entered manually into the computer every 10 minutes. The insulin and pramlintide pumps' infusion rates will then be changed manually based on the computer generated recommendation, while still maintaining the ratio. The computer generated recommendations are based on a predictive algorithm. | Other | Rapid Insulin-alone closed-loop delivery, Rapid Insulin-plus-pramlintide closed-loop delivery, Regular Insulin-plus-pramlintide closed-loop delivery |
Primary outcome
Percentage of time of plasma glucose levels spent in target range. Target range is defined to be between 3.9 and 10.0 mmol/L of fast-acting insulin-plus-pramlintide closed-loop delivery vs. fast-acting insulin-alone closed-loop delivery.
Time frame: Up to 24 hours
Percentage of time of plasma glucose levels spent in target range. Target range is defined to be between 3.9 and 10.0 mmol/L of regular insulin-plus-pramlintide closed-loop delivery vs. fast-acting insulin-alone closed-loop delivery.
Time frame: Up to 24 hours
12 secondary outcomes
Percentage of time of plasma glucose levels spent in target range, comparing fast-acting insulin-plus-pramlintide closed-loop delivery vs. regular insulin-plus-pramlintide closed-loop delivery.
Time frame: Up to 24 hours
Percentage of time (8:00-8:00) of plasma glucose levels spent: a. 3.9-7.8 mmol/L; b. 3.9-10 mmol/L; c. <3.9 mmol/L; d. <3.3 mmol/L; e. <2.8 mmol/L; f. >7.8 mmol/L; g. >10 mmol/L; h. >13.9 mmol/L; i. >16.7 mmol/L
Time frame: Up to 24 hours
Percentage of overnight time (23:00-8:00) of plasma glucose levels: a. 3.9-7.8 mmol/L; b. 3.9-10 mmol/L; c. <3.9 mmol/L; d. <3.3 mmol/L; e. <2.8 mmol/L; f. >7.8 mmol/L; g. >10 mmol/L; h. >13.9 mmol/L; i. >16.7 mmol/L
Time frame: Up to 24 hours
Standard deviation of glucose levels as a measure of glucose variability.
Time frame: Up to 24 hours
Total insulin delivery.
Time frame: Up to 24 hours
Total pramlintide delivery.
Time frame: Up to 24 hours
Mean plasma glucose level during: a. the overall study period; b. overnight period.
Time frame: Up to 24 hours
Mean plasma insulin concentration.
Time frame: Up to 24 hours
Mean plasma glucagon concentration.
Time frame: Up to 24 hours
Mean plasma amylin concentration.
Time frame: Up to 24 hours
Number of subjects experiencing hypoglycemia requiring oral treatment during: a. the overall study period; b. the night.
Time frame: Up to 24 hours
Gastrointestinal symptoms during the treatment optimization (i.e., the minimum 10 days prior to the 24-hour closed-loop visits) and during the 24-hour closed-loop visits.
Time frame: Up to 24 hours
Results and safety
The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.
Research links
- Official record on ClinicalTrials.govLast updated by the sponsor 17 Feb 2020.
- Derived from this study: PubMed 31974099Haidar A, Tsoukas MA, Bernier-Twardy S, Yale JF, Rutkowski J, Bossy A, Pytka E, El Fathi A, Strauss N, Legault L. A Novel Dual-Hormone Insulin-and-Pramlintide Artificial Pancreas for Type 1 Diabetes: A Randomized Controlled Crossover Trial. Diabetes Care. 2020 Mar;43(3):597-606. doi: 10.2337/dc19-1922. Epub 2020 Jan 23.
- Derived from this study: PubMed 31613140Tsoukas M, Rutkowski J, El-Fathi A, Yale JF, Bernier-Twardy S, Bossy A, Pytka E, Legault L, Haidar A. Accuracy of FreeStyle Libre in Adults with Type 1 Diabetes: The Effect of Sensor Age. Diabetes Technol Ther. 2020 Mar;22(3):203-207. doi: 10.1089/dia.2019.0262. Epub 2020 Jan 23.
- Individual participant dataSharing planned: No
Related trials for Diabetes Mellitus, Type 1
Not yet recruitingPhase 3
A Study to Evaluate the Effectiveness and Safety of the Drug AZD6234 for Managing Weight in Adults Who Are Obese or Overweight. These Participants May or May Not Also Have Type 2 Diabetes
Obesity, Overweight
RecruitingPhase 1
Pharmacokinetics, Safety, and Immunogenicity Comparison of Bmab1700 and Opdivo® as Adjuvant Monotherapy in Participants With Melanoma
Melanoma
Active, not recruitingPhase 2
A Study of Botensilimab and Balstilimab for the Treatment of Colorectal Cancer
Metastatic Colorectal Cancer
Not yet recruiting
Inter-Arm Differences in Continuous Glucose Monitor Readings in Adults With Diabetes
Continuous Glucose Monitoring, Type 1 Diabetes
RecruitingObservational study
Estimated Risk of Preeclampsia in the First Trimester and Its Association With Subclinical Atherosclerosis and Cardiovascular Risk in Women With Type 1 Diabetes
Type 1 Diabetes, Preeclampsia
Referral and contact
AzTrials does not enrol participants or take referrals. Contact the study team or a site listed below; they decide who can take part. This study is not recruiting at the moment.
Ahmad Haidar principal investigator
McGill University
Laurent Legault principal investigator
McGill University Health Centre/Research Institute of the McGill University Health Centre
1 site in 1 country: see every site and its status.
Questions about this trial
What is this clinical trial studying?
A Phase 2 study testing 24-hour inpatient intervention in people with Diabetes Mellitus, Type 1, run by McGill University at 1 site in Canada.
The full registered description is in the About this study section and the official record.
Who may be eligible to take part?
The sponsor lists 4 inclusion and 12 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.
Is this clinical trial currently recruiting?
The record says: finished, as of the sponsor's last update on 17 Feb 2020. Status can change between updates, so confirm with the study contact before making plans.
Where is the study taking place?
The record lists 1 site in Canada. Whether a site is taking part right now should be confirmed with that site. See every site.
What are the possible benefits and risks?
They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.
What does this phase mean?
Phase 2 studies give the treatment to a larger group to see whether it has the intended effect and to keep checking safety.
Not every study follows the same path, and some studies (observational studies, device studies) have no phase.
Are results available for this study?
The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.
How can a doctor refer a patient or contact the research team?
The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.
What does the primary outcome measure?
Percentage of time of plasma glucose levels spent in target range. Target range is defined to be between 3.9 and 10.0 mmol/L of fast-acting insulin-plus-pramlintide closed-loop delivery vs. fast-acting insulin-alone closed-loop delivery. (time frame: Up to 24 hours). The study lists 2 primary outcomes in all. It is what the study was designed to measure, not a finding.
Where can I read the original study information?
On the ClinicalTrials.gov record for NCT02814123, which also lists 2 linked publications.
Does a listing mean the treatment is approved or proven to work?
No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.
How often is this information updated?
AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 17 Feb 2020.