Multichannel ECG SystemNCT02814396
The Application of Multichannel ECG Analytic System in Cardiovascular Diseases
An observational study of Multichannel ECG System, run by National Taiwan University Hospital at 1 site in Taiwan.
Trial summary
Cardiovascular disease (CVD) is the leading cause of death worldwide. Most individuals with CVD show no evidence of disease for decades as the disease progresses before the first onset of symptoms, often a "sudden" heart attack, finally arises. Read more about this study
- Who is it for?
- Ages 20 years and older
- Conditions the study is for
- Multichannel ECG System
- How many people
- 5,000 participants
- Where
- 1 siteTaiwan
- Study dates
- Jan 2013to Dec 2026
- Phase
- Observational
- Are there results?
- Not yet: the study is under way
Key requirements
Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.
- Ages 20 years and older
- All sexes
- No healthy volunteers
- Adult, Older adult
Study population: Space ventricular repolarization within the proposal does not have to represent functions in heart health and disease. Repolarization dispersion higher than normal levels may allow early diagnosis of CVD. The BSPM and magnetic diagram (MCG) is a newly developed method for both records, and provide higher spatial resolution than conventional ECG signal but has a high cost and bulky shortcomings. It is impossible in a portable manner. Previously, the investigators have used a 64-channel low TC SQUID MCG equipment to develop and validate two parameters, the so-called QT interval (SIQTc) and T wave propagation (TWP) smoothness index, accurate detection and localization of myocardial ischemia blood.
Who may be able to join
- Patients older than 20 years old.
- with suspected arrhythmia or cardiovascular diseases.
Who cannot join
- NO
Trial locations and contacts
1 site in 1 country. Contact the study team or a site near you to ask about taking part.
Taiwan1 site, 1 recruiting
- Recruiting
NTUH
Taipei
chau C Wu, Ph.D, MD, 886-2-23123456 ext. 88560, chauchungwu@ntu.edu.tw
About this study
Cardiovascular disease (CVD) is the leading cause of death worldwide. Most individuals with CVD show no evidence of disease for decades as the disease progresses before the first onset of symptoms, often a "sudden" heart attack, finally arises. The spatial repolarization heterogeneity within the ventricular myocardium had been proposed to represent the function of the heart in health and disease. Greater than normal levels of repolarization dispersion may allow early diagnosis of CVD. There is a growing interest in the characteristic features of ventricular repolarization that leads to lethal ventricular arrhythmia even with the use of non-antiarrhythmic drugs. The recovery time dispersion may reflect a repolarization heterogeneity leading to lethal ventricular arrhythmia. Previously, the investigators had utilized a 64-channel low-TC SQUID MCG device to develop and verify 2 parameters, so called smooth index of QTc (SIQTc) and T wave propagation (TWP), to accurately detect and localize the myocardial ischemia. Recently Nakai, et al. reported that a newly developed 187-ch signal-averaged vector-projected ECG (187-ch SAVP-ECG) could evaluate low-amplitude high-frequency potentials and repolarization heterogeneity. In this project, the investigators'll try to modify and improve the spatial resolution of ECG signals from a Self-built-in multichannel ECG system with a newly developed algorithm, and also try to derive the SIQTc and TWP from this system, for early detection of CVD. The investigators intend to prove the concept that this newly developed multichannel ECG system could efficiently detect or diagnose CVD with acceptable sensitivity and specificity, and in a portable way.
Read the detailed description
Cardiovascular disease (CVD) is the leading cause of death worldwide. Most individuals with CVD show no evidence of disease for decades as the disease progresses before the first onset of symptoms, often a "sudden" heart attack, finally arises. The spatial repolarization heterogeneity within the ventricular myocardium had been proposed to represent the function of the heart in health and disease. Greater than normal levels of repolarization dispersion may allow early diagnosis of CVD. There is a growing interest in the characteristic features of ventricular repolarization that leads to lethal ventricular arrhythmia even with the use of non-antiarrhythmic drugs. The recovery time dispersion may reflect a repolarization heterogeneity leading to lethal ventricular arrhythmia. Although cheap and convenient, the traditional 12-leads electrocardiogram (ECG) is frequently normal at rest in such patients. The quantification of repolarization heterogeneity with ECG, QT dispersion, has some methodological limitations and has been abandoned in daily practice. Many studies have shown that body surface potential mapping (BSPM) contains more diagnostic and prognostic information than that elicited from a 12-lead ECG. The BSPM and magnetocardiogram (MCG) are two new developed recording methods, and provide higher spatial resolution than traditional ECG signals but with the disadvantages of high cost and huge volume. It is impossible to be used in a portable way. Previously, the investigators had utilized a 64-channel low-TC SQUID MCG device to develop and verify 2 parameters, so called smooth index of QTc (SIQTc) and T wave propagation (TWP), to accurately detect and localize the myocardial ischemia. Recently Nakai, et al. reported that a newly developed 187-ch signal-averaged vector-projected ECG (187-ch SAVP-ECG) could evaluate low-amplitude high-frequency potentials and repolarization heterogeneity. In this project, the investigators'll try to modify and improve the spatial resolution of ECG signals from a Self-built-in multichannel ECG system with a newly developed algorithm, and also try to derive the SIQTc and TWP from this system, for early detection of CVD. The investigators intend to prove the concept that this newly developed multichannel ECG system could efficiently detect or diagnose CVD with acceptable sensitivity and specificity, and in a portable way.
- Conditions
- Multichannel ECG System
- Keywords
- Ventricular, CVD, Ventricular arrhythmias
What is being measured
The primary outcome is the main question the study is designed to answer.
Composite cardiovascular outcome
The composite cardiovascular (CV) outcome will be any CV events (coronary, cerebral, or peripheral vascular diseases)
Measured: up to 5 years
Secondary outcomes (1)
With at least 1 cardiovascular risk factor.
no evidence of atherosclerotic vascular diseases,with at least 1 cardiovascular risk factor.
Measured: up to 5 years
Timeline
From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.
- First posted27 Jun 2016 (estimated)
- Study startJan 2013
- Primary completionDec 2026 (estimated)
- Study completionDec 2026 (estimated)
Resources
- Official record on ClinicalTrials.govThe registry entry this page is built from, with its full change history.
- Other trials for Multichannel ECG SystemStudies of the same condition, open and under way.
- More trials run by National Taiwan University HospitalThe sponsor's other registered studies.
- What the trial phases meanHow a treatment moves from first tests in people to approval.
More details
For doctors and researchers: how the study is designed, who runs it, and its registry IDs.
Study design
- Study type
- Observational
- Observational model
- Case only
- Time perspective
- Prospective
- Enrolment
- 5,000 participants (estimated)
Sponsor and investigators
- Lead sponsor
- National Taiwan University Hospital
- Sponsor type
- University, hospital or other
- Responsible party
- Sponsor
- Investigators
- Chau C WU, M.D.,Ph.D., Principal investigator, chauchungwu@ntu.edu.tw
IDs, dates and publications
- ClinicalTrials.gov ID
- NCT02814396
- Sponsor's protocol ID
- 201207070RIC
- Status last verified
- Jul 2026
- First submitted
- 23 Jun 2016
- Last updated
- 20 Jul 2026
- Results posted
- No
- Data monitoring committee
- Yes
- Individual data sharing
- Yes
Study at a glance
From the registry record, last updated by the sponsor on 20 Jul 2026. Recruitment status is as the sponsor reported it: confirm with the study team.
- Official title
- The Application of Multichannel ECG Analytic System in Cardiovascular Diseases
- ClinicalTrials.gov ID
- NCT02814396
- Acronym / sponsor ID
- 201207070RIC
- Conditions
- Multichannel ECG System
- Keywords
- Ventricular, CVD, Ventricular arrhythmias
- Study type
- Observational
- Recruitment status
- Recruiting
- Enrolment
- 5,000 participants (estimated)
- Lead sponsor
- National Taiwan University HospitalUniversity, hospital or other
- Study start
- Jan 2013
- Primary completion
- Dec 2026 (estimated)
- Study completion
- Dec 2026 (estimated)
- First posted
- 27 Jun 2016 (estimated)
- Results
- Not posted in the source record
Clinical summary
The research question as the sponsor registered it. This describes what the study plans to test, not what it found.
Cardiovascular disease (CVD) is the leading cause of death worldwide. Most individuals with CVD show no evidence of disease for decades as the disease progresses before the first onset of symptoms, often a "sudden" heart attack, finally arises. The spatial repolarization heterogeneity within the ventricular myocardium had been proposed to represent the function of the heart in health and disease. Greater than normal levels of repolarization dispersion may allow early diagnosis of CVD. There is a growing interest in the characteristic features of ventricular repolarization that leads to lethal ventricular arrhythmia even with the use of non-antiarrhythmic drugs. The recovery time dispersion may reflect a repolarization heterogeneity leading to lethal ventricular arrhythmia. Previously, the investigators had utilized a 64-channel low-TC SQUID MCG device to develop and verify 2 parameters, so called smooth index of QTc (SIQTc) and T wave propagation (TWP), to accurately detect and localize the myocardial ischemia. Recently Nakai, et al. reported that a newly developed 187-ch signal-averaged vector-projected ECG (187-ch SAVP-ECG) could evaluate low-amplitude high-frequency potentials and repolarization heterogeneity. In this project, the investigators'll try to modify and improve the spatial resolution of ECG signals from a Self-built-in multichannel ECG system with a newly developed algorithm, and also try to derive the SIQTc and TWP from this system, for early detection of CVD. The investigators intend to prove the concept that this newly developed multichannel ECG system could efficiently detect or diagnose CVD with acceptable sensitivity and specificity, and in a portable way.
Detailed description
Cardiovascular disease (CVD) is the leading cause of death worldwide. Most individuals with CVD show no evidence of disease for decades as the disease progresses before the first onset of symptoms, often a "sudden" heart attack, finally arises. The spatial repolarization heterogeneity within the ventricular myocardium had been proposed to represent the function of the heart in health and disease. Greater than normal levels of repolarization dispersion may allow early diagnosis of CVD. There is a growing interest in the characteristic features of ventricular repolarization that leads to lethal ventricular arrhythmia even with the use of non-antiarrhythmic drugs. The recovery time dispersion may reflect a repolarization heterogeneity leading to lethal ventricular arrhythmia. Although cheap and convenient, the traditional 12-leads electrocardiogram (ECG) is frequently normal at rest in such patients. The quantification of repolarization heterogeneity with ECG, QT dispersion, has some methodological limitations and has been abandoned in daily practice. Many studies have shown that body surface potential mapping (BSPM) contains more diagnostic and prognostic information than that elicited from a 12-lead ECG. The BSPM and magnetocardiogram (MCG) are two new developed recording methods, and provide higher spatial resolution than traditional ECG signals but with the disadvantages of high cost and huge volume. It is impossible to be used in a portable way. Previously, the investigators had utilized a 64-channel low-TC SQUID MCG device to develop and verify 2 parameters, so called smooth index of QTc (SIQTc) and T wave propagation (TWP), to accurately detect and localize the myocardial ischemia. Recently Nakai, et al. reported that a newly developed 187-ch signal-averaged vector-projected ECG (187-ch SAVP-ECG) could evaluate low-amplitude high-frequency potentials and repolarization heterogeneity. In this project, the investigators'll try to modify and improve the spatial resolution of ECG signals from a Self-built-in multichannel ECG system with a newly developed algorithm, and also try to derive the SIQTc and TWP from this system, for early detection of CVD. The investigators intend to prove the concept that this newly developed multichannel ECG system could efficiently detect or diagnose CVD with acceptable sensitivity and specificity, and in a portable way.
Study design
- Observational model
- Case only
- Time perspective
- Prospective
Who may qualify
- Ages
- 20 years and older
- Sex
- All
- Healthy volunteers
- Not accepted
- Age groups
- Adult, Older adult
- Study population
- Space ventricular repolarization within the proposal does not have to represent functions in heart health and disease. Repolarization dispersion higher than normal levels may allow early diagnosis of CVD. The BSPM and magnetic diagram (MCG) is a newly developed method for both records, and provide higher spatial resolution than conventional ECG signal but has a high cost and bulky shortcomings. It is impossible in a portable manner. Previously, the investigators have used a 64-channel low TC SQUID MCG equipment to develop and validate two parameters, the so-called QT interval (SIQTc) and T wave propagation (TWP) smoothness index, accurate detection and localization of myocardial ischemia blood.
Key inclusion criteria (2 listed)
- Patients older than 20 years old.
- with suspected arrhythmia or cardiovascular diseases.
Key exclusion criteria (1 listed)
- NO
Eligibility is decided by the study team after screening; this overview does not establish that a patient qualifies. Full inclusion and exclusion criteria.
Primary outcome
Composite cardiovascular outcome
Time frame: up to 5 years
The composite cardiovascular (CV) outcome will be any CV events (coronary, cerebral, or peripheral vascular diseases)
1 secondary outcome
With at least 1 cardiovascular risk factor.
Time frame: up to 5 years
Results and safety
This study is still under way. Results are not available in the source record yet.
Research links
- Official record on ClinicalTrials.govLast updated by the sponsor 20 Jul 2026.
- Individual participant dataSharing planned: Yes
Referral and contact
AzTrials does not enrol participants or take referrals. Contact the study team or a site listed below; they decide who can take part.
Chau C WU, M.D.,Ph.D. principal investigator
chauchungwu@ntu.edu.tw
1 site in 1 country: see every site and its status.
Questions about this trial
What is this clinical trial studying?
An observational study of Multichannel ECG System, run by National Taiwan University Hospital at 1 site in Taiwan.
The full registered description is in the About this study section and the official record.
Who may be eligible to take part?
The sponsor lists 2 inclusion and 1 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.
Is this clinical trial currently recruiting?
The record says: looking for participants now, as of the sponsor's last update on 20 Jul 2026. Status can change between updates, so confirm with the study contact before making plans.
Where is the study taking place?
The record lists 1 site in Taiwan. Whether a site is taking part right now should be confirmed with that site. See every site.
What are the possible benefits and risks?
They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.
Are results available for this study?
This study is still under way. Results are not available in the source record yet.
How can a doctor refer a patient or contact the research team?
Contact Chau C Wu, M.D.,Ph.D. (886-2-23123456 ext. 88560, chauchungwu@ntu.edu.tw), or a site near the patient. AzTrials does not enrol participants or take referrals.
What does the primary outcome measure?
Composite cardiovascular outcome (time frame: up to 5 years). It is what the study was designed to measure, not a finding.
Where can I read the original study information?
Does a listing mean the treatment is approved or proven to work?
No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.
How often is this information updated?
AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 20 Jul 2026.