Paroxysmal Atrial FibrillationTRAC-AFNCT02821351
ACT DiamondTemp TempeRAture-Controlled and Contact Sensing RF Ablation Clinical Trial for Atrial Fibrillation
A study testing Radio frequency (RF) Cardiac ablation in people with Paroxysmal Atrial Fibrillation, run by Medtronic Cardiac Ablation Solutions at 4 sites in 2 countries.
Trial summary
The primary objective of this study is to establish the safety and performance effectiveness of the DiamondTemp System for the treatment of drug refractory, recurrent, symptomatic paroxysmal atrial fibrillation (PAF). Read more about this study
- Who is it for?
- Ages 18 years and older
- Conditions the study is for
- Paroxysmal Atrial Fibrillation
- What is being tested?
- Radio frequency (RF) Cardiac ablation
- Type of treatment
- Medical device
- Could I receive a placebo?
- No, everyone receives an active treatment
- How many people
- 70 participants
- Where
- 4 sitesin 2 countries
- Study dates
- Jan 2016to Sep 2018
- Phase
- Interventional
- Are there results?
- None posted in the registry
Key requirements
Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.
- Ages 18 years and older
- All sexes
- No healthy volunteers
- Adult, Older adult
Study Inclusion Criteria
Subjects for this study must meet ALL of the following criteria:
- Suitable candidate for intra-cardiac mapping and ablation for arrhythmias.
- History of recurrent symptomatic PAF1 WITH ≥2 episodes reported within the 365 days (12) months prior to enrollment.
- At least one episode of AF documented by Holter monitor, rhythm strip, trans-telephonic monitor (TTM), or 12-lead ECG prior to enrollment
- Refractory to at least one Class I - IV anti-arrhythmic drug (AAD)
- Eighteen (18) years of age or above
- Competent and willing to provide written informed consent to participate in the study and agree to comply with the follow-up visits and evaluation.
Study Exclusion Criteria
Candidates will be excluded from the study if any of the following conditions apply:
- Previous left atrial ablation procedure
- Intracardiac thrombus, tumor or other abnormality that precludes catheter introduction and placement
- Known severe cerebrovascular disease or history of cerebrovascular event (within 1 month)
- Patients with severely impaired kidney function as measured by a Cockcroft-Gault Glomerular Filtration Rate (GFR)3 with a GFR ≤ 29. This is calculated as follows for males:
GFR = (140 - age) x weight x .85 (for females) PCr x 72 where age is specified in years, weight in kg, and PCr is Serum Creatinine in mg/dL Female GFR is reduced by 15% of the above calculated value for males.
- Active gastrointestinal bleeding
- Active infection or fever (> 100.5 F/38 C)
- Sepsis
- Cardiac surgery within the past two months
- Short life expectancy (< 1yr) due to other illnesses, such as cancer or pulmonary, hepatic, or renal disease
- Significant anemia (hemoglobin < 8.0 mg/dL)
- Severe uncontrolled systemic hypertension (systolic press. > 240 mm Hg within the last 30 days)
- Documented anaphylaxis during previous exposure to angiographic contrast media
- Uncontrolled congestive heart failure (NYHA Class III or IV)
- Unstable angina or acute myocardial infarction within the past three months
- Bleeding, clotting disorders, or known thrombosis
- Severe Peripheral vascular disease
- Uncontrolled diabetes
- Rheumatic heart disease
- Heart valve replacement
- Mitral clip (Evalve)
- Women who are of childbearing potential who are currently pregnant or not willing to use contraception for the duration of the study
- Active participation in another investigational protocol currently or the last 30 days
- Unable or unwilling to take anti-coagulants
- Unwilling or unable to comply with any protocol or follow up requirements
Trial locations and contacts
4 sites in 2 countries.
4 sites in 2 countries
Czechia3 sites
St Anne's University Hospital
Brno
Institut Klinické a Experimentální Medicíny (IKEM)
Prague
Nemocnice Na Homolce
Prague
About this study
Official title: Advanced Cardiac Therapeutics DiamondTemp TempeRAture-Controlled and Contact Sensing RF Ablation Clinical Trial for Atrial Fibrillation
The primary objective of this study is to establish the safety and performance effectiveness of the DiamondTemp System for the treatment of drug refractory, recurrent, symptomatic paroxysmal atrial fibrillation (PAF).
Read the detailed description
Study Title: Advanced Cardiac Therapeutics DiamondTemp TempeRAture-Controlled and Contact Sensing RF Ablation Clinical Trial for Atrial Fibrillation: TRAC-AF
Sponsor: Advanced Cardiac Therapeutics 2880 Lakeside Drive Suite 250 Santa Clara, CA 95054
Protocol No: DTAF-CZ01
Product: Cardiac Ablation Catheter and RF Generator/Pump System Investigational Device: DiamondTemp System (Inclusive of the DiamondTemp Ablation Catheter, DiamondTemp Catheter-to-RFG Cable, DiamondTemp GenConnect Cable, DiamondTemp RF Generator, DiamondTemp Irrigation Pump and DiamondTemp Irrigation Tubing)
PROTOCOL SUMMARY Advanced Cardiac Therapeutics DiamondTemp TempeRAture-Controlled and Contact Sensing RF Ablation Clinical Trial for Atrial Fibrillation: TRAC-AF
Study Objective:
The primary objective of this study is to assess the safety and performance effectiveness of the DiamondTemp System for the treatment of drug refractory, recurrent, symptomatic paroxysmal atrial fibrillation (PAF).
Investigational Device:
The investigational device in this clinical study is the DiamondTemp System inclusive of
- DiamondTemp Catheter (UPN: CZDT100S, CZDT100L)
- DiamondTemp Catheter-to RFG Cable (UPN: CZDC100)
- DiamondTemp GenConnect Cable (UPN: CZDTGC100)
- DiamondTemp RF Generator (UPN:CZDTG100)
- DiamondTemp Irrigation Pump (UPN: CZDP100)
- DiamondTemp Irrigation Tubing Set (UPN: CZDTS100)
System Accessories:
- Dispersive Indifferent Patch (DIP) electrodes
- Power Cord
- EGM Cable (not supplied)
- St. Jude Maestro GenConnect (not supplied)
The investigational device can be used with commonly available EP Recording System, Cardiac Stimulator and the ST. Jude EnSite™ Velocity™ Cardiac Mapping System.
There are no control devices in this study.
Study Design/Planned Number of Subjects/Number of Centers This study is a prospective, single center, single arm study. A maximum of 75 subjects will be enrolled in the study to include a maximum of 5 roll-in subjects in one investigational center in the Czech Republic.
Primary Endpoints The primary endpoint events for this trial as follows are to assess the safety and performance effectiveness of the DiamondTemp System for the treatment of drug refractory, recurrent, symptomatic PAF.
- Primary Safety Endpoint: The safety of the DiamondTemp System will be assessed by evaluating the nature and frequency of serious adverse events (SAE) and serious adverse device effects (SADE) during the time of the ablation procedure and within 7 days afterwards.
- Primary Effectiveness Endpoint: The effectiveness of the DiamondTemp System will be evaluated post-ablation with demonstration of acute procedural success defined as isolation of clinically relevant pulmonary veins by demonstration of block or isolation of signals confirmed after delivery of the ablation treatment. Depending on EP lab protocol, one method will be chosen.
Secondary Endpoints
The following secondary endpoint will be evaluated to support the results of the primary endpoints:
- Secondary Safety Endpoint: The chronic safety of the DiamondTemp System will be assessed by evaluating the nature and frequency of adverse events (AE) and adverse device effects (ADE) at 30 days, 90 days, 6 months and 12 months post-procedure.
Study Duration The duration of the study is expected to last approximately 18 months from the first enrollment to final report for assessment of endpoints. An additional 12 months to the study closeout after the last follow-up.
Key Inclusion Criteria
- Suitable candidate for intra-cardiac mapping for arrhythmias
- History of recurrent symptomatic PAF WITH ≥2 episodes reported within the 365 days (12) months prior to enrollment
- At least 1 episode of atrial fibrillation (AF) documented by Holter monitor, rhythm strip, trans-telephonic monitor (TTM), or 12-lead ECG prior to enrollment
- Refractory to at least one Class I-IV anti-arrhythmic drug (AAD)
- Eighteen (18) years of age or above
- Competent and willing to provide written informed consent to participate in the study and agree to comply with the follow-up visits and evaluation
Key Exclusion Criteria
- Previous ablation procedure in the left atrium
- Intracardiac thrombus, tumor or other abnormality that precludes catheter introduction and placement
- Known severe cerebrovascular disease or history of cerebrovascular event (within 1 month)
- Cardiac surgery within the past two months.
- Short life expectancy (< 1 yr.) due to other illnesses, such as cancer or pulmonary, hepatic, or renal disease
- Uncontrolled congestive heart failure (NYHA Class III or IV)
- Unstable angina or acute myocardial infarction within the past three months
- Bleeding, clotting disorders, or known thrombosis
- Heart valve replacement
- Mitral clip (Evalve)
- Unable or unwilling to take anti-coagulants
Ablation Procedure The ablation procedure will consist of documentation of pre-ablation pulmonary vein (PV) potentials, conducting PV isolation using the DiamondTemp System, providing documentation of PV entrance block. Investigator can opt to perform other ablations if any non- PV foci are involved in atrial arrhythmia.
Follow-up Schedule
- Screening visit any time during six (6) months before ablation procedure
- Ablation Procedure (Day 0, all follow-ups post ablation are based on this date)
- Discharge (5-72 hours)
- 7-Day Phone Check (7 + 3 days)
- 1-Month Follow-up (30 + 5 days)
- Repeat Mapping Procedure
- Repeat Ablation Procedure, if necessary
- 3-Month Follow-up (90 + 10 days)
- 6-Month Follow-up (180 + 30 days)
- 12-Month Follow-up (365 + 30 days)
- Additional Follow-up visits (as determined necessary)
The study will be considered complete for the purpose of reporting results with regards to the primary endpoints after all subjects have completed the 7-Day follow-up. A final study closeout report will be created after the last 12-month follow-up visit.
- Conditions
- Paroxysmal Atrial Fibrillation
- Being tested
- Radio frequency (RF) Cardiac ablation
- Keywords
- Afib
- Medical subject headings
- Atrial Fibrillation
What participants receive
What participants receive. In a randomised study each person is assigned to one group by chance.
Radio frequency (RF) Cardiac ablationDevice
Also called RF Ablation
Catheter based RF cardiac ablation to treat Paroxysmal Atrial Fibrillation
| Study group | Role | What they receive |
|---|---|---|
| DiamondTemp | Experimental | Bilateral pulmonary vein isolation by RF ablation using DiamondTemp temperature controlled catheter and RF generator/pump system Receives: Device: Radio frequency (RF) Cardiac ablation |
What is being measured
The primary outcome is the main question the study is designed to answer.
Nature and frequency of serious adverse events (SAE) and serious adverse device effects (SADE)
The safety of the DiamondTemp System will be assessed by evaluating the nature and frequency of serious adverse events (SAE) and serious adverse device effects (SADE) during the time of the ablation procedure and within 7 days afterwards.
Measured: Seven days
Electrical Isolation of treated Pulmonary Vein from Left Atrium
The effectiveness of the DiamondTemp System will be evaluated post-ablation with demonstration of acute procedural success defined as isolation of clinically relevant pulmonary veins by demonstration of block or isolation of signals confirmed after delivery of the ablation treatment. Depending on EP lab protocol, one method will be chosen.
Measured: Seven days
Secondary outcomes (1)
Nature and frequency of serious adverse events (SAE) and serious adverse device effects (SADE) up to a year after treatment
The chronic safety of the DiamondTemp System will be assessed by evaluating the nature and frequency of adverse events (AE) and adverse device effects (ADE) at 30 days, 90 days, 6 months and 12 months post-procedure
Measured: During 12 months after the treatment
Timeline
From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.
- First posted1 Jul 2016 (estimated)
- Study startJan 2016
- Primary completionAug 2017
- Study completionSep 2018
Resources
- Official record on ClinicalTrials.govThe registry entry this page is built from, with its full change history.
- Publications (2)Papers the sponsor has linked to this study.
- Other trials for Paroxysmal Atrial FibrillationStudies of the same condition, open and under way.
- More trials run by Medtronic Cardiac Ablation SolutionsThe sponsor's other registered studies.
- What the trial phases meanHow a treatment moves from first tests in people to approval.
More details
For doctors and researchers: how the study is designed, who runs it, and its registry IDs.
Study design
- Study type
- Interventional
- Phase
- Phase N/A
- Primary purpose
- Treatment
- Allocation
- Not applicable
- Intervention model
- Single group
- Masking
- None (open label)
- Enrolment
- 70 participants (actual)
Sponsor and investigators
- Lead sponsor
- Medtronic Cardiac Ablation Solutions
- Sponsor type
- Industry (pharma, biotech, devices)
- Responsible party
- Sponsor
- Investigators
- Petr Neuzil, MD, PhD, Principal investigator, Na Homolce Hospital
IDs, dates and publications
- ClinicalTrials.gov ID
- NCT02821351
- Sponsor's protocol ID
- DTAF-CZ01
- Acronym
- TRAC-AF
- Status last verified
- Feb 2025
- First submitted
- 22 Jun 2016
- Last updated
- 13 Feb 2025
- Results posted
- No
- Data monitoring committee
- No
- Individual data sharing
- Undecided
Publications
Starek Z, Lehar F, Jez J, Pesl M, Neuzil P, Sediva L, Petru J, Dujka L, Funasako M, Kautzner J, Peichl P, Aldhoon B, Albenque JP, Combes S, Boveda S, Dukkipati SR, Reddy VY. Efficacy and safety of novel temperature-controlled radiofrequency ablation system during pulmonary vein isolation in patients with paroxysmal atrial fibrillation: TRAC-AF study. J Interv Card Electrophysiol. 2022 Aug;64(2):375-381. doi: 10.1007/s10840-021-00986-0. Epub 2021 Jun 5.
PubMed 34089431Iwasawa J, Koruth JS, Petru J, Dujka L, Kralovec S, Mzourkova K, Dukkipati SR, Neuzil P, Reddy VY. Temperature-Controlled Radiofrequency Ablation for Pulmonary Vein Isolation in Patients With Atrial Fibrillation. J Am Coll Cardiol. 2017 Aug 1;70(5):542-553. doi: 10.1016/j.jacc.2017.06.008.
PubMed 28750697
Study at a glance
From the registry record, last updated by the sponsor on 13 Feb 2025. Recruitment status is as the sponsor reported it: confirm with the study team.
- Official title
- Advanced Cardiac Therapeutics DiamondTemp TempeRAture-Controlled and Contact Sensing RF Ablation Clinical Trial for Atrial Fibrillation
- ClinicalTrials.gov ID
- NCT02821351
- Acronym / sponsor ID
- TRAC-AF / DTAF-CZ01
- Conditions
- Paroxysmal Atrial Fibrillation
- Keywords
- Afib
- Study type
- Interventional
- Recruitment status
- Completed
- Enrolment
- 70 participants (actual)
- Lead sponsor
- Medtronic Cardiac Ablation SolutionsIndustry (pharma, biotech, devices)
- Study start
- Jan 2016 (actual)
- Primary completion
- Aug 2017 (actual)
- Study completion
- Sep 2018 (actual)
- First posted
- 1 Jul 2016 (estimated)
- Results
- Not posted in the source record
Clinical summary
The research question as the sponsor registered it. This describes what the study plans to test, not what it found.
The primary objective of this study is to establish the safety and performance effectiveness of the DiamondTemp System for the treatment of drug refractory, recurrent, symptomatic paroxysmal atrial fibrillation (PAF).
Detailed description
Study Title: Advanced Cardiac Therapeutics DiamondTemp TempeRAture-Controlled and Contact Sensing RF Ablation Clinical Trial for Atrial Fibrillation: TRAC-AF
Sponsor: Advanced Cardiac Therapeutics 2880 Lakeside Drive Suite 250 Santa Clara, CA 95054
Protocol No: DTAF-CZ01
Product: Cardiac Ablation Catheter and RF Generator/Pump System Investigational Device: DiamondTemp System (Inclusive of the DiamondTemp Ablation Catheter, DiamondTemp Catheter-to-RFG Cable, DiamondTemp GenConnect Cable, DiamondTemp RF Generator, DiamondTemp Irrigation Pump and DiamondTemp Irrigation Tubing)
PROTOCOL SUMMARY Advanced Cardiac Therapeutics DiamondTemp TempeRAture-Controlled and Contact Sensing RF Ablation Clinical Trial for Atrial Fibrillation: TRAC-AF
Study Objective:
The primary objective of this study is to assess the safety and performance effectiveness of the DiamondTemp System for the treatment of drug refractory, recurrent, symptomatic paroxysmal atrial fibrillation (PAF).
Investigational Device:
The investigational device in this clinical study is the DiamondTemp System inclusive of
- DiamondTemp Catheter (UPN: CZDT100S, CZDT100L)
- DiamondTemp Catheter-to RFG Cable (UPN: CZDC100)
- DiamondTemp GenConnect Cable (UPN: CZDTGC100)
- DiamondTemp RF Generator (UPN:CZDTG100)
- DiamondTemp Irrigation Pump (UPN: CZDP100)
- DiamondTemp Irrigation Tubing Set (UPN: CZDTS100)
System Accessories:
- Dispersive Indifferent Patch (DIP) electrodes
- Power Cord
- EGM Cable (not supplied)
- St. Jude Maestro GenConnect (not supplied)
The investigational device can be used with commonly available EP Recording System, Cardiac Stimulator and the ST. Jude EnSite™ Velocity™ Cardiac Mapping System.
There are no control devices in this study.
Study Design/Planned Number of Subjects/Number of Centers This study is a prospective, single center, single arm study. A maximum of 75 subjects will be enrolled in the study to include a maximum of 5 roll-in subjects in one investigational center in the Czech Republic.
Primary Endpoints The primary endpoint events for this trial as follows are to assess the safety and performance effectiveness of the DiamondTemp System for the treatment of drug refractory, recurrent, symptomatic PAF.
- Primary Safety Endpoint: The safety of the DiamondTemp System will be assessed by evaluating the nature and frequency of serious adverse events (SAE) and serious adverse device effects (SADE) during the time of the ablation procedure and within 7 days afterwards.
- Primary Effectiveness Endpoint: The effectiveness of the DiamondTemp System will be evaluated post-ablation with demonstration of acute procedural success defined as isolation of clinically relevant pulmonary veins by demonstration of block or isolation of signals confirmed after delivery of the ablation treatment. Depending on EP lab protocol, one method will be chosen.
Secondary Endpoints
The following secondary endpoint will be evaluated to support the results of the primary endpoints:
- Secondary Safety Endpoint: The chronic safety of the DiamondTemp System will be assessed by evaluating the nature and frequency of adverse events (AE) and adverse device effects (ADE) at 30 days, 90 days, 6 months and 12 months post-procedure.
Study Duration The duration of the study is expected to last approximately 18 months from the first enrollment to final report for assessment of endpoints. An additional 12 months to the study closeout after the last follow-up.
Key Inclusion Criteria
- Suitable candidate for intra-cardiac mapping for arrhythmias
- History of recurrent symptomatic PAF WITH ≥2 episodes reported within the 365 days (12) months prior to enrollment
- At least 1 episode of atrial fibrillation (AF) documented by Holter monitor, rhythm strip, trans-telephonic monitor (TTM), or 12-lead ECG prior to enrollment
- Refractory to at least one Class I-IV anti-arrhythmic drug (AAD)
- Eighteen (18) years of age or above
- Competent and willing to provide written informed consent to participate in the study and agree to comply with the follow-up visits and evaluation
Key Exclusion Criteria
- Previous ablation procedure in the left atrium
- Intracardiac thrombus, tumor or other abnormality that precludes catheter introduction and placement
- Known severe cerebrovascular disease or history of cerebrovascular event (within 1 month)
- Cardiac surgery within the past two months.
- Short life expectancy (< 1 yr.) due to other illnesses, such as cancer or pulmonary, hepatic, or renal disease
- Uncontrolled congestive heart failure (NYHA Class III or IV)
- Unstable angina or acute myocardial infarction within the past three months
- Bleeding, clotting disorders, or known thrombosis
- Heart valve replacement
- Mitral clip (Evalve)
- Unable or unwilling to take anti-coagulants
Ablation Procedure The ablation procedure will consist of documentation of pre-ablation pulmonary vein (PV) potentials, conducting PV isolation using the DiamondTemp System, providing documentation of PV entrance block. Investigator can opt to perform other ablations if any non- PV foci are involved in atrial arrhythmia.
Follow-up Schedule
- Screening visit any time during six (6) months before ablation procedure
- Ablation Procedure (Day 0, all follow-ups post ablation are based on this date)
- Discharge (5-72 hours)
- 7-Day Phone Check (7 + 3 days)
- 1-Month Follow-up (30 + 5 days)
- Repeat Mapping Procedure
- Repeat Ablation Procedure, if necessary
- 3-Month Follow-up (90 + 10 days)
- 6-Month Follow-up (180 + 30 days)
- 12-Month Follow-up (365 + 30 days)
- Additional Follow-up visits (as determined necessary)
The study will be considered complete for the purpose of reporting results with regards to the primary endpoints after all subjects have completed the 7-Day follow-up. A final study closeout report will be created after the last 12-month follow-up visit.
Study design
- Primary purpose
- Treatment
- Allocation
- Not applicable
- Intervention model
- Single group
- Masking
- None (open label)
- Number of arms
- 1
| Arm | Type | Receives |
|---|---|---|
| DiamondTemp | Experimental | Device: Radio frequency (RF) Cardiac ablationBilateral pulmonary vein isolation by RF ablation using DiamondTemp temperature controlled catheter and RF generator/pump system |
Who may qualify
- Ages
- 18 years and older
- Sex
- All
- Healthy volunteers
- Not accepted
- Age groups
- Adult, Older adult
Eligibility is decided by the study team after screening; this overview does not establish that a patient qualifies. Full inclusion and exclusion criteria.
Interventions
| Intervention | Type | Arms |
|---|---|---|
| Radio frequency (RF) Cardiac ablationAlso: RF AblationCatheter based RF cardiac ablation to treat Paroxysmal Atrial Fibrillation | Device | DiamondTemp |
Primary outcome
Nature and frequency of serious adverse events (SAE) and serious adverse device effects (SADE)
Time frame: Seven days
The safety of the DiamondTemp System will be assessed by evaluating the nature and frequency of serious adverse events (SAE) and serious adverse device effects (SADE) during the time of the ablation procedure and within 7 days afterwards.
Electrical Isolation of treated Pulmonary Vein from Left Atrium
Time frame: Seven days
The effectiveness of the DiamondTemp System will be evaluated post-ablation with demonstration of acute procedural success defined as isolation of clinically relevant pulmonary veins by demonstration of block or isolation of signals confirmed after delivery of the ablation treatment. Depending on EP lab protocol, one method will be chosen.
1 secondary outcome
Nature and frequency of serious adverse events (SAE) and serious adverse device effects (SADE) up to a year after treatment
Time frame: During 12 months after the treatment
Results and safety
The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.
Research links
- Official record on ClinicalTrials.govLast updated by the sponsor 13 Feb 2025.
- Derived from this study: PubMed 34089431Starek Z, Lehar F, Jez J, Pesl M, Neuzil P, Sediva L, Petru J, Dujka L, Funasako M, Kautzner J, Peichl P, Aldhoon B, Albenque JP, Combes S, Boveda S, Dukkipati SR, Reddy VY. Efficacy and safety of novel temperature-controlled radiofrequency ablation system during pulmonary vein isolation in patients with paroxysmal atrial fibrillation: TRAC-AF study. J Interv Card Electrophysiol. 2022 Aug;64(2):375-381. doi: 10.1007/s10840-021-00986-0. Epub 2021 Jun 5.
- Derived from this study: PubMed 28750697Iwasawa J, Koruth JS, Petru J, Dujka L, Kralovec S, Mzourkova K, Dukkipati SR, Neuzil P, Reddy VY. Temperature-Controlled Radiofrequency Ablation for Pulmonary Vein Isolation in Patients With Atrial Fibrillation. J Am Coll Cardiol. 2017 Aug 1;70(5):542-553. doi: 10.1016/j.jacc.2017.06.008.
- Individual participant dataSharing planned: Undecided
Related trials for Paroxysmal Atrial Fibrillation
Recruiting
A Study Assessing Arrhythmia Mapping With a Multi-Electrode Mapping Catheter
Scar-related Atrial Tachycardia, Persistent Atrial Fibrillation
Active, not recruitingObservational study
THERMOCOOL SMARTTOUCH®SF Catheters With Ablation Index Study
Paroxysmal Atrial Fibrillation
Not yet recruitingObservational study
Catheter Ablation Using a Novel Navigation and Imaging System
Paroxysmal Atrial Fibrillation
Not yet recruiting
Paroxysmal Atrial Fibrillation Repeat Ablation Strategies With Durably Isolated Pulmonary Veins
Ablation Techniques, Atrial Fibrillation (Paroxysmal)
Active, not recruiting
VOLT CE Mark Study
Atrial Arrhythmia, Atrial Fibrillation
Referral and contact
AzTrials does not enrol participants or take referrals. Contact the study team or a site listed below; they decide who can take part. This study is not recruiting at the moment.
Petr Neuzil, MD, PhD principal investigator
Na Homolce Hospital
4 sites in 2 countries: see every site and its status.
Questions about this trial
What is this clinical trial studying?
A study testing Radio frequency (RF) Cardiac ablation in people with Paroxysmal Atrial Fibrillation, run by Medtronic Cardiac Ablation Solutions at 4 sites in 2 countries.
The full registered description is in the About this study section and the official record.
Who may be eligible to take part?
Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.
Is this clinical trial currently recruiting?
The record says: finished, as of the sponsor's last update on 13 Feb 2025. Status can change between updates, so confirm with the study contact before making plans.
Where is the study taking place?
The record lists 4 sites in Czechia, France. Whether a site is taking part right now should be confirmed with that site. See every site.
What are the possible benefits and risks?
They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.
Are results available for this study?
The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.
How can a doctor refer a patient or contact the research team?
The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.
What does the primary outcome measure?
Nature and frequency of serious adverse events (SAE) and serious adverse device effects (SADE) (time frame: Seven days). The study lists 2 primary outcomes in all. It is what the study was designed to measure, not a finding.
Where can I read the original study information?
On the ClinicalTrials.gov record for NCT02821351, which also lists 2 linked publications.
Does a listing mean the treatment is approved or proven to work?
No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.
How often is this information updated?
AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 13 Feb 2025; AzTrials last refreshed its copy on 6 Nov 2026.