CataractsNCT02826421
Clinical Investigation of Corneal Incision Size After Intraocular Lens (IOL) Implantation
A study testing UltraSert Preloaded Delivery System, iTec Preloaded Delivery System and iSert Preloaded Delivery System in people with Cataracts, run by Alcon Research.
Trial summary
The purpose of this study is to compare corneal incision size after IOL implantation with the use of one of four IOL delivery systems (three preloaded IOL delivery systems and one manually loaded IOL delivery system). Read more about this study
- Who is it for?
- Ages 22 years and older
- Conditions the study is for
- Cataracts
- What is being tested?
- UltraSert Preloaded Delivery System, iTec Preloaded Delivery System and iSert Preloaded Delivery System
- Type of treatment
- Medical device
- Could I receive a placebo?
- No, everyone receives an active treatment
- How many people
- 114 participants
- Where
- No sites listed yet
- Study dates
- 4 Jul 2016to 29 Nov 2016
- Phase
- Interventional
- Are there results?
- Yes, posted in the registrySummary in the doctors' view
Key requirements
Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.
- Ages 22 years and older
- All sexes
- No healthy volunteers
- Adult, Older adult
Who may be able to join
- Able to comprehend and sign a statement of informed consent;
- Willing and able to complete all required postoperative visits;
- Cataract;
- Planned cataract removal by phacoemulsification;
- Calculated lens power from 18.0 through 27.0 D inclusive;
- Preoperative astigmatism <1.0D;
- Other protocol-specified inclusion criteria may apply.
Who cannot join
- Systemic disease that affects the cornea;
- Any inflammation or edema of the cornea;
- Previous or planned refractive or corneal surgery during the subject's participation in the study;
- Previous corneal transplant;
- Previous retinal detachment;
- Pregnancy or lactation, current or planned, during the course of the study;
Show all 9Show fewer
- Current participation in another investigational drug or device study that may confound the results of this investigation;
- Any condition observed before or during surgery that in the surgeon's medical opinion may affect the success of the cataract surgery;
- Other protocol-specified exclusion criteria may apply.
About this study
Official title: Clinical Investigation of Corneal Incision Size After IOL Implantation With Preloaded Delivery Devices and a Manual Delivery Device
The purpose of this study is to compare corneal incision size after IOL implantation with the use of one of four IOL delivery systems (three preloaded IOL delivery systems and one manually loaded IOL delivery system).
- Conditions
- Cataracts
- Being tested
- UltraSert Preloaded Delivery System, iTec Preloaded Delivery System, iSert Preloaded Delivery System, Monarch III D Manual IOL Delivery System
- Keywords
- Intraocular lens
- Medical subject headings
- Cataract
What participants receive
What participants receive. In a randomised study each person is assigned to one group by chance.
UltraSert Preloaded Delivery SystemDevice
Includes AcrySof IQ monofocal posterior chamber IOL Model AU00T0, intended for long term use over the lifetime of the subject
iTec Preloaded Delivery SystemDevice
Includes TECNIS 1-piece monofocal IOL, intended for long term use over the lifetime of the subject
iSert Preloaded Delivery SystemDevice
Includes Model 251 or Model 250 posterior chamber IOL, as selected by the Investigator, intended for long term use over the lifetime of the subject
Monarch III D Manual IOL Delivery SystemDevice
Includes AcrySof IQ monofocal IOL posterior chamber IOL Model SN60WF, intended for long term use over the lifetime of the subject
| Study group | Role | What they receive |
|---|---|---|
| UltraSert Preloaded Delivery System | Experimental | Preloaded IOL delivered via a 2.2 mm clear corneal incision during cataract surgery Receives: Device: UltraSert Preloaded Delivery System |
| iTec Preloaded Delivery System | Active comparator | Preloaded IOL delivered via a 2.2 mm clear corneal incision during cataract surgery Receives: Device: iTec Preloaded Delivery System |
| iSert Preloaded Delivery System | Active comparator | Preloaded IOL delivered via a 2.2 mm clear corneal incision during cataract surgery Receives: Device: iSert Preloaded Delivery System |
| Monarch III D Manual IOL Delivery System | Active comparator | Manually loaded IOL delivered via a 2.4 mm clear corneal incision during cataract surgery Receives: Device: Monarch III D Manual IOL Delivery System |
What is being measured
The primary outcome is the main question the study is designed to answer.
Mean Corneal Incision Size After IOL Implantation (UltraSert, iTec, and iSert)
Post-IOL implantation corneal incision size was measured directly after IOL implantation and reported in millimeters (mm). Minimizing enlargement of incision size during cataract surgery results in less postoperative inflammation, less surgically-induced astigmatism, and more rapid visual and wound rehabilitation. This endpoint was prespecified for the UltraSert, iTec, and iSert preloaded delivery systems. Only one eye (study eye) contributed to the analysis.
Measured: Day 0, operative day
Secondary outcomes (1)
Mean Corneal Incision Size After IOL Implantation (UltraSert and Monarch III D)
Post-IOL implantation corneal incision size was measured directly after IOL implantation and reported in millimeters (mm). Minimizing enlargement of incision size during cataract surgery results in less postoperative inflammation, less surgically-induced astigmatism, and more rapid visual and wound rehabilitation. This endpoint was prespecified for the UltraSert preloaded delivery system and the Monarch III D delivery system. Only one eye (study eye) contributed to the analysis.
Measured: Day 0, operative day
Timeline
From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.
- First posted11 Jul 2016 (estimated)
- Study start4 Jul 2016
- Primary completion29 Nov 2016
- Study completion29 Nov 2016
Resources
- Official record on ClinicalTrials.govThe registry entry this page is built from, with its full change history.
- Posted resultsParticipant flow, outcome measures and adverse events reported by the sponsor.
- Other trials for CataractsStudies of the same condition, open and under way.
- More trials run by Alcon ResearchThe sponsor's other registered studies.
- What the trial phases meanHow a treatment moves from first tests in people to approval.
More details
For doctors and researchers: how the study is designed, who runs it, and its registry IDs.
Study design
- Study type
- Interventional
- Phase
- Phase N/A
- Primary purpose
- Treatment
- Allocation
- Randomised
- Intervention model
- Parallel groups
- Masking
- Single blind
- Who is masked
- Participant
- Enrolment
- 114 participants (actual)
Sponsor and investigators
- Lead sponsor
- Alcon Research
- Sponsor type
- Industry (pharma, biotech, devices)
- Responsible party
- Sponsor
- Investigators
- Sr. Clinical Manager, GCRA, Study director, Alcon Research
IDs, dates and publications
- ClinicalTrials.gov ID
- NCT02826421
- Sponsor's protocol ID
- ILN296-P001
- Status last verified
- Jul 2017
- First submitted
- 5 Jul 2016
- Last updated
- 2 Jul 2018
- Results posted
- Yes, on ClinicalTrials.gov
- Data monitoring committee
- No
- FDA-regulated drug
- No
- FDA-regulated device
- Yes
Study at a glance
From the registry record, last updated by the sponsor on 2 Jul 2018. Recruitment status is as the sponsor reported it: confirm with the study team.
- Official title
- Clinical Investigation of Corneal Incision Size After IOL Implantation With Preloaded Delivery Devices and a Manual Delivery Device
- ClinicalTrials.gov ID
- NCT02826421
- Acronym / sponsor ID
- ILN296-P001
- Conditions
- Cataracts
- Keywords
- Intraocular lens
- Study type
- Interventional
- Recruitment status
- Completed
- Enrolment
- 114 participants (actual)
- Lead sponsor
- Alcon ResearchIndustry (pharma, biotech, devices)
- Study start
- 4 Jul 2016 (actual)
- Primary completion
- 29 Nov 2016 (actual)
- Study completion
- 29 Nov 2016 (actual)
- First posted
- 11 Jul 2016 (estimated)
- Results
- Posted 28 Jul 2017
Clinical summary
The research question as the sponsor registered it. This describes what the study plans to test, not what it found.
The purpose of this study is to compare corneal incision size after IOL implantation with the use of one of four IOL delivery systems (three preloaded IOL delivery systems and one manually loaded IOL delivery system).
Study design
- Primary purpose
- Treatment
- Allocation
- Randomised
- Intervention model
- Parallel groups
- Masking
- Single blind (participant)
- Number of arms
- 4
| Arm | Type | Receives |
|---|---|---|
| UltraSert Preloaded Delivery System | Experimental | Device: UltraSert Preloaded Delivery SystemPreloaded IOL delivered via a 2.2 mm clear corneal incision during cataract surgery |
| iTec Preloaded Delivery System | Active comparator | Device: iTec Preloaded Delivery SystemPreloaded IOL delivered via a 2.2 mm clear corneal incision during cataract surgery |
| iSert Preloaded Delivery System | Active comparator | Device: iSert Preloaded Delivery SystemPreloaded IOL delivered via a 2.2 mm clear corneal incision during cataract surgery |
| Monarch III D Manual IOL Delivery System | Active comparator | Device: Monarch III D Manual IOL Delivery SystemManually loaded IOL delivered via a 2.4 mm clear corneal incision during cataract surgery |
Who may qualify
- Ages
- 22 years and older
- Sex
- All
- Healthy volunteers
- Not accepted
- Age groups
- Adult, Older adult
Key inclusion criteria (7 listed)
- Able to comprehend and sign a statement of informed consent;
- Willing and able to complete all required postoperative visits;
- Cataract;
- Planned cataract removal by phacoemulsification;
- Calculated lens power from 18.0 through 27.0 D inclusive;
Key exclusion criteria (9 listed)
- Systemic disease that affects the cornea;
- Any inflammation or edema of the cornea;
- Previous or planned refractive or corneal surgery during the subject's participation in the study;
- Previous corneal transplant;
- Previous retinal detachment;
Eligibility is decided by the study team after screening; this overview does not establish that a patient qualifies. Full inclusion and exclusion criteria.
Interventions
| Intervention | Type | Arms |
|---|---|---|
| UltraSert Preloaded Delivery SystemIncludes AcrySof IQ monofocal posterior chamber IOL Model AU00T0, intended for long term use over the lifetime of the subject | Device | UltraSert Preloaded Delivery System |
| iTec Preloaded Delivery SystemIncludes TECNIS 1-piece monofocal IOL, intended for long term use over the lifetime of the subject | Device | iTec Preloaded Delivery System |
| iSert Preloaded Delivery SystemIncludes Model 251 or Model 250 posterior chamber IOL, as selected by the Investigator, intended for long term use over the lifetime of the subject | Device | iSert Preloaded Delivery System |
| Monarch III D Manual IOL Delivery SystemIncludes AcrySof IQ monofocal IOL posterior chamber IOL Model SN60WF, intended for long term use over the lifetime of the subject | Device | Monarch III D Manual IOL Delivery System |
Primary outcome
Mean Corneal Incision Size After IOL Implantation (UltraSert, iTec, and iSert)
Time frame: Day 0, operative day
Post-IOL implantation corneal incision size was measured directly after IOL implantation and reported in millimeters (mm). Minimizing enlargement of incision size during cataract surgery results in less postoperative inflammation, less surgically-induced astigmatism, and more rapid visual and wound rehabilitation. This endpoint was prespecified for the UltraSert, iTec, and iSert preloaded delivery systems. Only one eye (study eye) contributed to the analysis.
1 secondary outcome
Mean Corneal Incision Size After IOL Implantation (UltraSert and Monarch III D)
Time frame: Day 0, operative day
Results and safety
Loading the posted results from ClinicalTrials.gov…
Research links
- Official record on ClinicalTrials.govLast updated by the sponsor 2 Jul 2018.
- Posted resultsParticipant flow, baseline, all outcome measures and adverse events.
Related trials for Cataracts
Recruiting
Implementing AI-based Glaucoma Screening Within Federally Qualified Health Centers
Glaucoma, Ocular Hypertension
Not yet recruiting
Trial to Investigate the Safety and Effectiveness of the KI-362-US1 (YP2.2VM) Intraocular Lens (IOL) in Adult Participants for Correction of Aphakia Following Cataract Extraction
Aphakia, Postcataract
Not yet recruiting
Effects of Oxygen Cage Support During Cataract Surgery
Cataract
Active, not recruitingObservational study
Age-Related Eye Disease Study (AREDS) Follow-Up
Age-Related Macular Degeneration, Cataract
RecruitingObservational study
Objective Depth-of-Focus Changes During Light Adjustable Lens UV Adjustments
Light Adjustable Lens, Objective Depth of Focus
Referral and contact
AzTrials does not enrol participants or take referrals. Contact the study team or a site listed below; they decide who can take part. This study is not recruiting at the moment.
Sr. Clinical Manager, GCRA study director
Alcon Research
Questions about this trial
What is this clinical trial studying?
A study testing UltraSert Preloaded Delivery System, iTec Preloaded Delivery System and iSert Preloaded Delivery System in people with Cataracts, run by Alcon Research.
The full registered description is in the About this study section and the official record.
Who may be eligible to take part?
The sponsor lists 7 inclusion and 9 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.
Is this clinical trial currently recruiting?
The record says: finished, as of the sponsor's last update on 2 Jul 2018. Status can change between updates, so confirm with the study contact before making plans.
What are the possible benefits and risks?
They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.
Are results available for this study?
Yes. Results are posted in the registry (first posted 28 Jul 2017). A summary is in the For doctors view, and the full results are on ClinicalTrials.gov.
How can a doctor refer a patient or contact the research team?
The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.
What does the primary outcome measure?
Mean Corneal Incision Size After IOL Implantation (UltraSert, iTec, and iSert) (time frame: Day 0, operative day). It is what the study was designed to measure, not a finding.