A study testing FLIR ThermaCAM P-65 in people with Breast Cancer, run by University Hospital of North Norway at 1 site in Norway.

Completed

Finished. The study has ended and is not enrolling. Results may be posted on the official record.

Official record
Search all trials

Trial summary

This study evaluate diagnostic accuracy of dynamic infrared thermography compared to mammography (reference test) in breast cancer diagnostics. Women aged 50-70 years, selected for assessment after mammography screening were invited to dynamic infrared thermography before clinical mammography and further examination. Read more about this study

Who is it for?
Ages 50 to 69 years, women only
Conditions the study is for
Breast Cancer
What is being tested?
FLIR ThermaCAM P-65
Type of treatment
Medical device
Could I receive a placebo?
No, everyone receives an active treatment
How many people
168 participants
Where
1 siteNorway
Study dates
Apr 2009to Jun 2012
Phase
Interventional
Are there results?
None posted in the registry

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 50 to 69 years
  • Women only
  • No healthy volunteers
  • Adult, Older adult

Who may be able to join

  • women,
  • aged 50-69
  • attending the Norwegian Breast Screening Program,
  • recalled for assessment after positive mammography screening

Who cannot join

  • not attending the Norwegian Breast Screening Program,
  • recalled to mammography for other reason than positive screening mammogram.

Trial locations and contacts

1 site in 1 country.

Norway1 site
  • Åshild Odden Miland

    Tromsø, Tromsø, 9037

Other trials in Norway

About this study

Official title: Dynamic Infrared Thermography in Breast Cancer Diagnostics. A Diagnostic Accuracy Study Comparing Dynamic Infrared Thermography Against Mammography (Reference Standard)

This study evaluate diagnostic accuracy of dynamic infrared thermography compared to mammography (reference test) in breast cancer diagnostics. Women aged 50-70 years, selected for assessment after mammography screening were invited to dynamic infrared thermography before clinical mammography and further examination.

Read the detailed description

This study evaluate diagnostic accuracy of dynamic infrared thermography compared to mammography (reference test) in breast cancer diagnostics.

Dynamic infrared thermography (DIRT) is an imagine procedure offering a non-invasive, painless examination without risk of radiation. Dynamic infrared thermography does not provide information on the morphological characteristics of the breast, rather it provides functional information on thermal and vascular conditions of the tissue (Fitzgerald, 2012).

During the study period from April 2009 until June 2012, a total of 168 women aged 50-70 years who were recalled for assessment after positive mammography screening were offered dynamic infrared thermography before further tests (clinical mammography, clinical examination and if necessary breast tissue biopsy).

Radiographers at the Breast Diagnostic Center (BDS) at University Hospital North Norway collected information about parity, menopausal status, use of hormone therapy and size of bra.

The same radiographers also carried out all the dynamic infrared thermography examinations. PI Åshild O. Miland and Professor James B. Mercer interpreted the thermograms and entered the data into the thermography database. Both were blinded for further assessments (mammography, clinical examination and biopsy) and non of them talked to any of the participants after the examination.

The health professionals who were responsible for the women during mammography, clinical examination and biopsy were blinded for the results from the infrared digital thermography examination. They were not allowed to ask the women about the infrared digital thermography examination.

The three radiologists at BDS made the interpretation of the mammographies and entered data into the digital patient journal and to the mammography database at The Norwegian Cancer Registry. One of the radiologist took, when necessary, breast biopsies. A breast surgeons were responsible for the clinical breast examination. Pathologists verified the histology.

Breast radiologist Jan Ole Frantzen and researcher Merethe Kumle, MD, PhD collected information about breast cancer results from the digital patient journal and Roentgen information system (RIS) and entered it into a separate mammography database.

The thermography database and the mammography database was still not merged at the time of registration in ClinicalTrials.gov (March 2015).

Conditions
Breast Cancer
Being tested
FLIR ThermaCAM P-65
Keywords
Sensitivity, Specificity, Breast cancer, Mammography, Thermography, Infrared, Dynamic, Diagnostic accuracy, Diagnostic odds ratio
Medical subject headings
Breast Neoplasms, Hypersensitivity

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • FLIR ThermaCAM P-65Device

    Also called Serial number: 25300659

    Women recalled for assessment after positive screening mammography were offered dynamic infrared thermography before clinical mammography and further tests.

Study groups in NCT02829021
Study groupRoleWhat they receive
Thermography and mammographyOtherAll participants will be examined with 1. Dynamic infrared thermography (FLIR ThermaCAM P-65) 2. Mammography, clinical examination and if necessary breast tissue biopsy to diagnose breast cancer.
Receives: Device: FLIR ThermaCAM P-65

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. Diagnostic accuracy of Thermography compared with Mammography and breast biopsy.

    Can thermography distinguish benign from malign tumours in breast cancer diagnostics. The gold standard is breast biopsy pathology.

    The outcome is measured as number of subjects with pathological diagnosis of cancer.

    Measured: Baseline

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted12 Jul 2016 (estimated)
  2. Study startApr 2009
  3. Primary completionJun 2012
  4. Study completionJun 2012

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Interventional
Phase
Phase N/A
Primary purpose
Diagnosis
Allocation
Not applicable
Intervention model
Single group
Masking
None (open label)
Enrolment
168 participants (actual)
IDs, dates and publications
ClinicalTrials.gov ID
NCT02829021
Sponsor's protocol ID
REK-109/2008
Other IDs
FAST-67
Status last verified
Jun 2016
First submitted
12 Apr 2016
Last updated
12 Jul 2016
Results posted
No
Data monitoring committee
No
Individual data sharing
Undecided: This is a small Diagnostic Accuracy Study, the investigators will decide upon data sharing when they have finished the statistical analysis. If someone is interested in the data, please contact the investigators.

Questions about this trial

What is this clinical trial studying?

A study testing FLIR ThermaCAM P-65 in people with Breast Cancer, run by University Hospital of North Norway at 1 site in Norway.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 4 inclusion and 2 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: finished, as of the sponsor's last update on 12 Jul 2016. Status can change between updates, so confirm with the study contact before making plans.

Where is the study taking place?

The record lists 1 site in Norway. Whether a site is taking part right now should be confirmed with that site. See every site.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.

How can a doctor refer a patient or contact the research team?

The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

Diagnostic accuracy of Thermography compared with Mammography and breast biopsy. (time frame: Baseline). It is what the study was designed to measure, not a finding.

Where can I read the original study information?
Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 12 Jul 2016.

Free account

Log in to keep searching

You’ve used your 3 free searches. AzTrials is free: log in or create a free account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in