AzTrials
AzTrials

Osteoarthritis of Hip(HRS-P)NCT02836262

Hip Replacement System (HRS-P) in Primary Total Hip Arthroplasty

A study testing HIT Hip Replacement System in people with Osteoarthritis of Hip, run by Hip Innovation Technology at 1 site in Canada.

Recruiting

Looking for participants now. Contact the study team or a site below to ask about taking part.

Sites and contacts
Official record

Search all trials

Trial summary

To evaluate effectiveness and safety of HHRS in subjects undergoing total hip arthroplasty (THA). Effectiveness will be evaluated using patient-reported, clinical, radiologic, and radiostereometric outcomes. Read more about this study

Who is it for?
Ages 65 to 79 years
Conditions the study is for
Osteoarthritis of Hip
What is being tested?
HIT Hip Replacement System
Type of treatment
Medical device
Could I receive a placebo?
No, everyone receives an active treatment
How many people
100 participants
Where
1 siteCanada
Study dates
25 Aug 2017to 16 Sep 2032
Phase
Interventional

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 65 to 79 years
  • All sexes
  • No healthy volunteers
  • Older adult

Who may be able to join

  • Patient has a non-inflammatory degenerative joint disease (NIDJD) or any of its composite diagnoses such as osteoarthritis, avascular necrosis, traumatic arthritis, slipped capital epiphysis, fracture of the pelvis, and diastrophic variant requiring unilateral primary total hip replacement.
  • Age between 65 and 79 years (inclusive) at the time of enrollment.
  • Patient is a suitable candidate for primary total hip replacement at the discretion of the Investigator.
  • Pre-surgery (within 28 days before surgery) WOMAC Global Score of 40 or larger on a scale from 0 (best) to 96 (worst)
  • Signed and dated informed consent document.
  • Patient is willing and able to participate in required follow-up visits at the Investigational site and to complete study procedures and questionnaires.

Who cannot join

  • Patient has had total hip replacement, hemi-arthroplasty, or fusion in either hip in the last 12 months;
  • Patient has planned total hip arthroplasty on a contra-lateral joint in the next 12 months;
  • Patient has a known allergy to any component of the study device;
  • Patient has a history of active sepsis in the joint;
  • Patient has an insufficient acetabular or femoral bone stock in which good anchorage of the implants are unlikely or impossible;
  • Patient has total or partial absence of the muscular or ligamentous apparatus;
Show all 19Show fewer
  • Patient has known moderate to severe renal insufficiency;
  • Patient has vascular insufficiency, muscular atrophy, or neuromuscular disease in either leg (based on the Investigator's discretion);
  • Patient has a deformity of the affected limb or significant anatomic variance of the affected hip;
  • Patient has an active malignancy or history of invasive malignancy within the last five years, with the exception of superficial basal cell carcinoma or squamous cell carcinoma of the skin that has been definitively treated. Patients with carcinoma in situ of the uterine cervix definitively treated more than 1 year prior to enrollment may enter the study;
  • Patient has any condition which may, in the opinion of the Investigator, interfere with the total hip replacement survival or patient outcomes (e.g. Paget's disease, Charcot's disease);
  • Patient has rheumatoid arthritis or other autoimmune condition that affect joints (e.g. Lupus Arthritis);
  • Patient has any condition that would interfere with patient self-assessment or pain, the function or quality of life required for patient reported outcomes during the study (based on the Investigator's discretion);
  • Body Mass Index (BMI) of 40 or more;
  • Patient has an active infection (e.g. hepatitis, AIDS, ARC) - systemic or at the site of intended surgery;
  • Patient is currently participating in any investigational study not related to this study's pre-operative or post-operative care;
  • Patient has any other severe acute or chronic medical condition that may interfere with the interpretation of the study results, in the judgment of the Investigator, which would make the patient inappropriate for entry into this study;
  • Patient has a history of metabolic bone disease (e.g. Paget's disease or osteomalacia);
  • Patient is currently pregnant or is planning to become pregnant.

Trial locations and contacts

1 site in 1 country. Contact the study team or a site near you to ask about taking part.

Linda Braddon, PhD contact

770-837-2681

LGB@SecureBME.com

Thomas Turgeon, MD contact

204-926-1218

tturgeon@cjrg.ca

Canada1 site, 1 recruiting
  • Orthopaedic Innovation Centre

    Winnipeg, Manitoba, R2K 2M9

    Thomas Turgeon, MD, (204) 926-1218, tturgeon@cjrg.ca

    Sarah Tran, (204) 926-1231, stran@orthoinno.com

    Recruiting

Other trials in Canada

About this study

Official title: A Multi-Center Prospective Study of the Hip Innovation Technology (HIT) Hip Replacement System in Primary Total Hip Arthroplasty

To evaluate effectiveness and safety of HHRS in subjects undergoing total hip arthroplasty (THA). Effectiveness will be evaluated using patient-reported, clinical, radiologic, and radiostereometric outcomes. Safety will be evaluated through the collection of device-related and unanticipated device-related adverse events.

Read the detailed description

The HIT Hip Replacement System (HHRS) is a Metal-on-Polyethylene (MoP) conventional hip prosthesis. The HHRS consists of a femoral stem, an acetabular cup and a Cobalt Chromium Molybdenum (CoCrMo) ball that articulates within a polyethylene liner. The ball sits on the acetabular cup, and the polyethylene liner is attached to the femoral cup, which attaches to the femoral stem, instead of the acetabular cup. The acetabular component of the HHRS consists of a hemispherical acetabular shell with a clustered screw-hole design. The outside of the shells are coated with titanium plasma to facilitate bone in-growth and provide secure intermediate fixation with the prepared bone surface at the site of implantation. The acetabular cup has a 3-hole design that accommodates three titanium alloy bone screws. Inside the acetabular cup is a male taper for assembly with the acetabular ball. The femoral component consists of a femoral stem manufactured from titanium and a mating cobalt chrome femoral cup lined with a highly cross-linked ultra-high-molecular-weight polyethylene (UHMWPE). As with the acetabular cup, the femoral stem is porous coated using a plasma spray of pure titanium, which is intended to facilitate bone in-growth and provide secure intermediate fixation with the prepared bone surface at the site of implantation. The femoral stem incorporates a female taper for assembly with the male taper of the femoral cup.

The device has undergone extensive pre-clinical testing. There is no clinical experience with the HRS.

Being tested
HIT Hip Replacement System
Medical subject headings
Osteoarthritis, Hip

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • HIT Hip Replacement SystemDevice

    HIT Hip Replacement System

Study groups in NCT02836262
Study groupRoleWhat they receive
HIT Hip Replacement System (HRS)ExperimentalSingle group assignment with historical controls.
Receives: Device: HIT Hip Replacement System

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. Change in Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC) v3.0 Likert Scale Functional Limitations Score between baseline (pre-operative) and the 730- day post-operative follow-up time point.

    Measured: between pre-operative and 730 days (24 months)

  2. Change in Harris Hip Score between baseline (pre-operative) and the 730-day post-operative follow-up time point.

    Measured: between pre-operative and 730 days (24 months)

Secondary outcomes (2)
  1. Change in Oxford Hip Score between 730-day post-operative and baseline (pre-surgery)

    Measured: between 730-days post-operative and baseline (pre-surgery)

  2. Change in Short Form 36 v2 Physical Component Score (PCS) between 730-days post-operative and baseline (pre-surgery)

    Measured: between 730-days post-operative and baseline (pre-surgery)

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted18 Jul 2016 (estimated)
  2. Study start25 Aug 2017
  3. Primary completion16 Sep 2029 (estimated)
  4. Study completion16 Sep 2032 (estimated)

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Interventional
Phase
Phase N/A
Primary purpose
Treatment
Allocation
Not applicable
Intervention model
Single group
Masking
None (open label)
Enrolment
100 participants (estimated)
IDs, dates and publications
ClinicalTrials.gov ID
NCT02836262
Sponsor's protocol ID
HIT-001
Acronym
(HRS-P)
Status last verified
Sep 2026
First submitted
14 Jul 2016
Last updated
21 Sep 2026
Results posted
No
Data monitoring committee
Yes
FDA-regulated drug
No
FDA-regulated device
No

Free account

Keep searching with a free account

You’ve used your 3 free searches for this session. Log in or create a free AzTrials account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in