Aortic Valve StenosisREPRISE EDGENCT02854319
REpositionable Percutaneous Replacement of NatIve StEnotic Aortic Valve Through Implantation of LOTUS EDGE Valve System
A study testing LOTUS Edge Valve System in people with Aortic Valve Stenosis, run by Boston Scientific Corporation at 3 sites in 3 countries.
Trial summary
The objective of the REPRISE EDGE study is to confirm the acute performance and safety of the LOTUS Edge™ Valve System when used with the Lotus™ or iSleeve™ Introducer Set for transcatheter aortic valve implantation (TAVI) in symptomatic patients with severe calcific aortic stenosis who are considered high risk for… Read more about this study
- Who is it for?
- Ages 70 years and older
- Conditions the study is for
- Aortic Valve Stenosis
- What is being tested?
- LOTUS Edge Valve System
- Type of treatment
- Medical device
- Could I receive a placebo?
- No, everyone receives an active treatment
- How many people
- 15 participants
- Where
- 3 sitesin 3 countries
- Study dates
- 7 Sep 2016to 13 Mar 2018
- Phase
- Interventional
- Are there results?
- None posted in the registry
Key requirements
Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.
- Ages 70 years and older
- All sexes
- No healthy volunteers
- Older adult
Who may be able to join
- Subject is ≥70 years of age.
- Subject has documented calcific native aortic valve stenosis with an initial aortic valve area (AVA) of <1.0 cm2 (or AVA index of <0.6 cm2/m2) and either a mean pressure gradient >40 mm Hg or a jet velocity >4 m/s, as measured by echocardiography and/or invasive hemodynamics.
- Note: In cases of low flow, low gradient aortic stenosis dobutamine can be used to assess the grade of aortic stenosis (maximum dobutamine dose of 20 mcg/kg/min recommended)c; the subject may be enrolled if echocardiographic criteria are met with this augmentation.
- Subject has a documented aortic annulus size between ≥20 mm and ≤27 mm based on pre-procedure diagnostic imaging.
- Subject has symptomatic aortic valve stenosis with NYHA Functional Class ≥ II.
- Subject is considered high risk for surgical valve replacement based on at least one of the following:
Show all 11Show fewer
- STS score ≥8%, and/or
- Agreement by the heart team (which must include an in-person evaluation by an experienced cardiac surgeon) that subject is at high operative risk of serious morbidity or mortality with surgical valve replacement.
- Heart team (which must include an experienced cardiac surgeon) assessment that the subject is likely to benefit from valve replacement
- Subject (or legal representative) understands the study requirements and the treatment procedures, and provides written informed consent.
- Subject, family member and/or legal representative agree(s) and subject is capable of returning to the study hospital for all required scheduled follow up visits.
Who cannot join
- Subject has a congenital unicuspid or bicuspid aortic valve.
- Subject with an acute myocardial infarction within 30 days of the index procedure (defined as Q-wave MI or non-Q-wave MI with total CK elevation ≥ twice normal in the presence of CK-MB elevation and/or troponin level elevation).
- Subject has had a cerebrovascular accident or transient ischemic attack within the past 6 months, or has any permanent neurologic defect prior to study enrollment.
- Subject is on dialysis or has serum creatinine level >3.0 mg/dL or 265 µml/L.
- Subject has a pre-existing prosthetic aortic or mitral valve.
- Subject has >3+ mitral regurgitation, >3+ aortic regurgitation or >3+ tricuspid regurgitation.
Show all 25Show fewer
- Subject has a need for emergency surgery for any reason.
- Subject has a history of endocarditis within 12 months of index procedure or evidence of an active systemic infection or sepsis.
- Subject has echocardiographic evidence of new intra-cardiac vegetation or intraventricular or paravalvular thrombus requiring intervention.
- Subject has Hgb <9 g/dL, platelet count <50,000 cells/mm3 or >700,000 cells/mm3, or white blood cell count <1,000 cells/mm3.
- Subject requires chronic anticoagulation therapy after the implant procedure and cannot be treated with warfarin (other anticoagulants are not permitted in the first month) for at least 1 month concomitant with either aspirin or clopidogrel.
- Note: An alternative P2Y12 inhibitor may be prescribed if subject is allergic to or intolerant of clopidogrel
- Subject has had a gastrointestinal bleed requiring hospitalization or transfusion within the past 3 months, or has other clinically significant bleeding diathesis or coagulopathy that would preclude treatment with required antiplatelet regimen, or will refuse transfusions.
- Subject has known hypersensitivity to contrast agents that cannot be adequately pre-medicated, or has known hypersensitivity to aspirin, all thienopyridines, heparin, nickel, titanium, or polyurethanes.
- Subject has a life expectancy of less than 12 months due to non-cardiac, co-morbid conditions based on the assessment of the investigator at the time of enrollment.
- Subject has hypertrophic obstructive cardiomyopathy.
- Subject has any therapeutic invasive cardiac procedure within 30 days prior to the index procedure (except for balloon aortic valvuloplasty and pacemaker implantation which are allowed).
- Subject has untreated coronary artery disease, which in the opinion of the treating physician, is clinically significant and requires revascularization.
- Subject has documented left ventricular ejection fraction <30%.
- Subject is in cardiogenic shock or has hemodynamic instability requiring inotropic support or mechanical support devices.
- Subject has severe vascular disease that would preclude safe access (e.g., aneurysm with thrombus that cannot be crossed safely, marked tortuosity, significant narrowing of the abdominal aorta, severe unfolding of the thoracic aorta, or symptomatic carotid or vertebral disease).
- Subject has arterial access that is not acceptable for the LOTUS Edge delivery system and its compatible Lotus or iSleeve Introducers as defined in the Directions For Use, or severe iliofemoral tortuosity or calcification that would prevent safe placement of either introducer sheath.
- Current problems with substance abuse (e.g., alcohol, etc.).
- Subject is participating in another investigational drug or device study that has not reached its primary endpoint.
- Subject does not have a permanent pacemaker but has a class I or II indication for pacemaker implantation (based on the latest available ESC guidelines).
Trial locations and contacts
3 sites in 3 countries.
3 sites in 3 countries
About this study
Official title: REPRISE EDGE: REpositionable Percutaneous Replacement of NatIve StEnotic Aortic Valve Through Implantation of LOTUS EDGE Valve System - Evaluation of Performance and Safety
The objective of the REPRISE EDGE study is to confirm the acute performance and safety of the LOTUS Edge™ Valve System when used with the Lotus™ or iSleeve™ Introducer Set for transcatheter aortic valve implantation (TAVI) in symptomatic patients with severe calcific aortic stenosis who are considered high risk for surgical valve replacement.
Read the detailed description
This clinical study is a prospective, single-arm study designed to demonstrate that the acute performance and safety of the LOTUS Edge Valve System when used with the iSleeve or Lotus Introducer Set are consistent with the results of the commercially approved Lotus Valve System used in the REPRISE II study, when delivered and deployed in symptomatic subjects who have severe calcific aortic valve stenosis and who are at high risk for surgical aortic valve replacement (SAVR).
- Conditions
- Aortic Valve Stenosis
- Being tested
- LOTUS Edge Valve System
- Medical subject headings
- Aortic Valve Stenosis
What participants receive
What participants receive. In a randomised study each person is assigned to one group by chance.
LOTUS Edge Valve SystemDevice
Transcatheter Aortic Valve Implantation (TAVI) with the LOTUS Edge™ Valve System when used with the Lotus™ or iSleeve™ Introducer Set
| Study group | Role | What they receive |
|---|---|---|
| LOTUS Edge Valve System | Experimental | Transcatheter aortic valve implantation (TAVI) with the LOTUS Edge™ Valve System when used with the Lotus™ or iSleeve™ Introducer Set Receives: Device: LOTUS Edge Valve System |
What is being measured
The primary outcome is the main question the study is designed to answer.
Mean aortic valve pressure gradient
Mean aortic valve pressure gradient as measured by echocardiography and assessed by an independent core laboratory.
Measured: At discharge from hospital or at 7 days post-procedure (whichever comes first)
Secondary outcomes (5)
Technical success
Defined as successful vascular access, delivery, and deployment of a Lotus Valve; successful retrieval with the delivery system; and correct positioning of a single Lotus Valve in the proper anatomical location (reported as percent of subjects implanted with a Lotus Valve). Reported as percent of subjects.
Measured: Immediately post-procedure (patient discharged from operative room)
Effective orifice area
Effective orifice area as measured by echocardiography and assessed by an independent core laboratory
Measured: At discharge from hospital or at 7 days post-procedure (whichever comes first)
Successful repositioning of the study valve if repositioning is attempted
Measured: Immediately post-procedure (patient discharged from operative room)
Successful retrieval of the study valve if retrieval is attempted
Measured: Immediately post-procedure (patient discharged from operative room)
Grade of paravalvular aortic regurgitation
Grade of paravalvular aortic regurgitation as measured by echocardiography and assessed by an independent core laboratory
Measured: At discharge from hospital or at 7 days post-procedure (whichever comes first)
Timeline
From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.
- First posted3 Aug 2016 (estimated)
- Study start7 Sep 2016
- Primary completion25 Oct 2016
- Study completion13 Mar 2018
Why it stopped: Investigational Medical Device is not available and the 15 patients enrolled completed their 1-yr follow-up per protocol
Resources
- Official record on ClinicalTrials.govThe registry entry this page is built from, with its full change history.
- Other trials for Aortic Valve StenosisStudies of the same condition, open and under way.
- More trials run by Boston Scientific CorporationThe sponsor's other registered studies.
- What the trial phases meanHow a treatment moves from first tests in people to approval.
More details
For doctors and researchers: how the study is designed, who runs it, and its registry IDs.
Study design
- Study type
- Interventional
- Phase
- Phase N/A
- Primary purpose
- Treatment
- Allocation
- Not applicable
- Intervention model
- Single group
- Masking
- None (open label)
- Enrolment
- 15 participants (actual)
Sponsor and investigators
- Lead sponsor
- Boston Scientific Corporation
- Sponsor type
- Industry (pharma, biotech, devices)
- Responsible party
- Sponsor
- Investigators
- Matthias Götberg, MD, PhD, Principal investigator, Skane University HospitalSabine Bleiziffer, MD, Principal investigator, German Heart Centre München
IDs, dates and publications
- ClinicalTrials.gov ID
- NCT02854319
- Sponsor's protocol ID
- S2367
- Acronym
- REPRISE EDGE
- Status last verified
- May 2018
- First submitted
- 28 Jul 2016
- Last updated
- 31 May 2018
- Results posted
- No
- Data monitoring committee
- Yes
- FDA-regulated drug
- No
- FDA-regulated device
- No
- Individual data sharing
- No
Study at a glance
From the registry record, last updated by the sponsor on 31 May 2018. Recruitment status is as the sponsor reported it: confirm with the study team.
- Official title
- REPRISE EDGE: REpositionable Percutaneous Replacement of NatIve StEnotic Aortic Valve Through Implantation of LOTUS EDGE Valve System - Evaluation of Performance and Safety
- ClinicalTrials.gov ID
- NCT02854319
- Acronym / sponsor ID
- REPRISE EDGE / S2367
- Conditions
- Aortic Valve Stenosis
- Study type
- Interventional
- Recruitment status
- TerminatedReason stopped: Investigational Medical Device is not available and the 15 patients enrolled completed their 1-yr follow-up per protocol
- Enrolment
- 15 participants (actual)
- Lead sponsor
- Boston Scientific CorporationIndustry (pharma, biotech, devices)
- Study start
- 7 Sep 2016 (actual)
- Primary completion
- 25 Oct 2016 (actual)
- Study completion
- 13 Mar 2018 (actual)
- First posted
- 3 Aug 2016 (estimated)
- Results
- Not posted in the source record
Clinical summary
The research question as the sponsor registered it. This describes what the study plans to test, not what it found.
The objective of the REPRISE EDGE study is to confirm the acute performance and safety of the LOTUS Edge™ Valve System when used with the Lotus™ or iSleeve™ Introducer Set for transcatheter aortic valve implantation (TAVI) in symptomatic patients with severe calcific aortic stenosis who are considered high risk for surgical valve replacement.
Detailed description
This clinical study is a prospective, single-arm study designed to demonstrate that the acute performance and safety of the LOTUS Edge Valve System when used with the iSleeve or Lotus Introducer Set are consistent with the results of the commercially approved Lotus Valve System used in the REPRISE II study, when delivered and deployed in symptomatic subjects who have severe calcific aortic valve stenosis and who are at high risk for surgical aortic valve replacement (SAVR).
Study design
- Primary purpose
- Treatment
- Allocation
- Not applicable
- Intervention model
- Single group
- Masking
- None (open label)
- Number of arms
- 1
| Arm | Type | Receives |
|---|---|---|
| LOTUS Edge Valve System | Experimental | Device: LOTUS Edge Valve SystemTranscatheter aortic valve implantation (TAVI) with the LOTUS Edge™ Valve System when used with the Lotus™ or iSleeve™ Introducer Set |
Who may qualify
- Ages
- 70 years and older
- Sex
- All
- Healthy volunteers
- Not accepted
- Age groups
- Older adult
Key inclusion criteria (11 listed)
- Subject is ≥70 years of age.
- Subject has documented calcific native aortic valve stenosis with an initial aortic valve area (AVA) of <1.0 cm2 (or AVA index of <0.6 cm2/m2) and either a mean pressure gradient >40 mm Hg or a jet velocity >4 m/s, as measured by echocardiography and/or invasive hemodynamics.
- Note: In cases of low flow, low gradient aortic stenosis dobutamine can be used to assess the grade of aortic stenosis (maximum dobutamine dose of 20 mcg/kg/min recommended)c; the subject may be enrolled if echocardiographic criteria are met with this augmentation.
- Subject has a documented aortic annulus size between ≥20 mm and ≤27 mm based on pre-procedure diagnostic imaging.
- Subject has symptomatic aortic valve stenosis with NYHA Functional Class ≥ II.
Key exclusion criteria (25 listed)
- Subject has a congenital unicuspid or bicuspid aortic valve.
- Subject with an acute myocardial infarction within 30 days of the index procedure (defined as Q-wave MI or non-Q-wave MI with total CK elevation ≥ twice normal in the presence of CK-MB elevation and/or troponin level elevation).
- Subject has had a cerebrovascular accident or transient ischemic attack within the past 6 months, or has any permanent neurologic defect prior to study enrollment.
- Subject is on dialysis or has serum creatinine level >3.0 mg/dL or 265 µml/L.
- Subject has a pre-existing prosthetic aortic or mitral valve.
Eligibility is decided by the study team after screening; this overview does not establish that a patient qualifies. Full inclusion and exclusion criteria.
Interventions
| Intervention | Type | Arms |
|---|---|---|
| LOTUS Edge Valve SystemTranscatheter Aortic Valve Implantation (TAVI) with the LOTUS Edge™ Valve System when used with the Lotus™ or iSleeve™ Introducer Set | Device | LOTUS Edge Valve System |
Primary outcome
Mean aortic valve pressure gradient
Time frame: At discharge from hospital or at 7 days post-procedure (whichever comes first)
Mean aortic valve pressure gradient as measured by echocardiography and assessed by an independent core laboratory.
5 secondary outcomes
Technical success
Time frame: Immediately post-procedure (patient discharged from operative room)
Effective orifice area
Time frame: At discharge from hospital or at 7 days post-procedure (whichever comes first)
Successful repositioning of the study valve if repositioning is attempted
Time frame: Immediately post-procedure (patient discharged from operative room)
Successful retrieval of the study valve if retrieval is attempted
Time frame: Immediately post-procedure (patient discharged from operative room)
Grade of paravalvular aortic regurgitation
Time frame: At discharge from hospital or at 7 days post-procedure (whichever comes first)
Results and safety
The study was stopped early (reason given: Investigational Medical Device is not available and the 15 patients enrolled completed their 1-yr follow-up per protocol). Results are not available in the source record.
Research links
- Official record on ClinicalTrials.govLast updated by the sponsor 31 May 2018.
- Individual participant dataSharing planned: No
Related trials for Aortic Valve Stenosis
Recruiting
Trial of the F2 Filter and Delivery System for Embolic Protection During TAVR
Aortic Stenosis Treated With TAVI, Aortic Diseases
Not yet recruiting
Human Experimental Models of Pain (HEMP)
Acute Pain
Active, not recruitingObservational study
Intravascular Lithotripsy in High Risk Calcified Iliac Anatomy for Transfemoral TAVR
Iliac Disease, Aortic Valve Stenosis
Not yet recruiting
NHLBI SESAME (SEptal Scoring Along Midline Endocardium) Multi-Center Prospective Study Using Improvised Off-Label Devices
Hypertrophic Cardiomyopathy, Left Ventricular Outflow Obstruction
Recruiting
Exercise and Diet Supplements for Older Patients Undergoing TAVI: the IRON-TAVI Trial
Aortic Stenosis Disease, Aortic Stenosis Symptomatic
Referral and contact
AzTrials does not enrol participants or take referrals. Contact the study team or a site listed below; they decide who can take part. This study is not recruiting at the moment.
Matthias Götberg, MD, PhD principal investigator
Skane University Hospital
Sabine Bleiziffer, MD principal investigator
German Heart Centre München
3 sites in 3 countries: see every site and its status.
Questions about this trial
What is this clinical trial studying?
A study testing LOTUS Edge Valve System in people with Aortic Valve Stenosis, run by Boston Scientific Corporation at 3 sites in 3 countries.
The full registered description is in the About this study section and the official record.
Who may be eligible to take part?
The sponsor lists 11 inclusion and 25 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.
Is this clinical trial currently recruiting?
The record says: stopped early, as of the sponsor's last update on 31 May 2018. Status can change between updates, so confirm with the study contact before making plans.
Where is the study taking place?
The record lists 3 sites in Denmark, France, Sweden. Whether a site is taking part right now should be confirmed with that site. See every site.
What are the possible benefits and risks?
They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.
Are results available for this study?
The study was stopped early (reason given: Investigational Medical Device is not available and the 15 patients enrolled completed their 1-yr follow-up per protocol). Results are not available in the source record.
How can a doctor refer a patient or contact the research team?
The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.
What does the primary outcome measure?
Mean aortic valve pressure gradient (time frame: At discharge from hospital or at 7 days post-procedure (whichever comes first)). It is what the study was designed to measure, not a finding.
Where can I read the original study information?
Does a listing mean the treatment is approved or proven to work?
No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.
How often is this information updated?
AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 31 May 2018.