AzTrials
AzTrials

Carbon Monoxide PoisoningCO-OXNCT02860455

Role of Pulse Co-oximetry for Detecting Carbon Monoxide Poisoning in the Prehospital Emergency Medical Service Setting

A study testing RAD57 measurement (SpCO) and CO-oximeter in people with Carbon Monoxide Poisoning, run by University Hospital, Montpellier at 1 site in France.

Unknown status

Status not confirmed. The sponsor has not verified this record for over two years, so it may be out of date.

Official record
Search all trials

Trial summary

The RAD-57 pulse CO-oximeter is a lightweight device allowing non-invasive measurement of blood carboxyhemoglobin. Previous studies comparing RAD-57 measurements (SpCO) to standard laboratory blood gas analysis (COHb) have reported contradictory results. Read more about this study

Who is it for?
Ages 18 years and older
Conditions the study is for
Carbon Monoxide Poisoning
What is being tested?
RAD57 measurement (SpCO) and CO-oximeter
Type of treatment
Medical device
Could I receive a placebo?
No, everyone receives an active treatment
How many people
176 participants
Where
1 siteFrance
Study dates
Feb 2012to Dec 2017
Phase
Interventional
Are there results?
None posted in the registry

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 18 years and older
  • All sexes
  • No healthy volunteers
  • Adult, Older adult

Who may be able to join

  • Patient aged 18 years or older
  • Patient managed by prehospital emergency medical services.
  • Patient with a suspected CO exposure presenting or not with clinical signs of CO poisoning

Who cannot join

  • Patient for whom venous blood sampling cannot be obtained prehospitally
  • Patient for whom SpCo measurement cannot be performed prehospitally (cardiac arrest, peripheral vasoconstriction)

Trial locations and contacts

1 site in 1 country.

Mustapha Sebbane, MD, PhD contact

0467337974

m-sebbane@chu-montpellier.fr

France1 site, 1 recruiting
  • Montpellier University hospital - Emergency department

    Montpellier, 34295

    Mustapha Sebbane, MD, Ph.D, 0467337974, m-sebbane@chu-montpellier.fr

    Recruiting

Other trials in France

About this study

Official title: Role of Pulse Co-oximetry in Prehospital Emergency Medical Service Management of Suspected Carbon Monoxide Poisoning : A Prospective Multicenter Study.

The RAD-57 pulse CO-oximeter is a lightweight device allowing non-invasive measurement of blood carboxyhemoglobin. Previous studies comparing RAD-57 measurements (SpCO) to standard laboratory blood gas analysis (COHb) have reported contradictory results.

the RAD-57 pulse CO-oximeter could be useful as a first-line screening test for acute CO poisoning, enabling rapid detection and management of patients with suspected CO poisoning in the prehospital emergency setting This study assesses the diagnostic value of pulse CO-oximetry, comparing SpCO to standard laboratory blood measurement for prehospital management of patients with suspected carbon monoxide (CO) poisoning.

Read the detailed description

Transcutaneous SpCO will be obtained using the RAD-57 simultaneously with blood sampling for laboratory blood gas analysis, at the time of prehospital management by emergency medical services. The diagnostic performance of SpCO for the screening of CO poisoning will be determined using ROC curve analysis, and Blood COHb levels >5% and 10% as the reference standard for CO poisonning for non-smokers and smokers respectively. Correlation between SpCO and COHb will be assessed using Bland and Altman's method.

Being tested
RAD57 measurement (SpCO), CO-oximeter
Keywords
CO poisoning, CO-oximetry, Pulse oximetry, Carbon monoxide saturation (SpCO), Emergency Department, Sensitivity, Specificity
Medical subject headings
Carbon Monoxide Poisoning, Emergencies, Hypersensitivity

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • RAD57 measurement (SpCO)Device

    Also called Non invasive pulse CO-oximetry

    SpCO measurement (Experimental)

    Non invasive pulse CO-oximetry will be carried out by prehospital emergency nursing staff trained in the use of the Rad-57 pulse CO-oximeter (Masimo, Inc., Irvine, CA, USA), using the adult sized sensor (Sensor, Rev. B) placed on the 3rd or 4th digit, according to manufacturer recommendations. Nail polish will be removed if necessary. SpCO was expressed in total percentage of hemoglobin.

  • CO-oximeterDevice

    COHb measurement (Active Comparator)

    Venous blood will be collected into EDTA treated tubes (Beckton Dickinson) prehospitally and sent to the toxicology laboratory for further carboxyhemoglobin testing. Blood carboxyhemoglobin will be analyzed by derivative spectrophotometry using an automated CO-oximeter (IL 682, Instrumentation Laboratory SpA V.le Monza 338-20128 Milan, Italy). Blood carboxyhemoglobin will be detected within a range of 0-100% and accuracy of 0.5% and reported as percentage of total haemoglobin.

Study groups in NCT02860455
Study groupRoleWhat they receive
SpCO and COHb measurementOtherSpCO measurement (Experimental) : Non invasive pulse CO-oximetry will be carried out in all patients simultaneously with venous blood sampling for standard laboratory blood gas analysis, at time of prehospital management by emergency medical services COHb measurement (Active comparator) : Blood carboxyhemoglobin testing will be carried out in all patients
Receives: Device: RAD57 measurement (SpCO); Device: CO-oximeter

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. SpCO optimal threshold value for detection of CO poisoning

    prehospital medical management

    Measured: Baseline

Secondary outcomes (2)
  1. SpCO level

    prehospital medical management

    Measured: Baseline

  2. COHb Blood carboxyhemoglobin level

    prehospital medical management

    Measured: Baseline

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted9 Aug 2016 (estimated)
  2. Study startFeb 2012
  3. Primary completionDec 2017 (estimated)
  4. Study completionDec 2017 (estimated)

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Interventional
Phase
Phase N/A
Primary purpose
Diagnosis
Allocation
Not applicable
Intervention model
Single group
Masking
None (open label)
Enrolment
176 participants (estimated)
IDs, dates and publications
ClinicalTrials.gov ID
NCT02860455
Sponsor's protocol ID
8869
Acronym
CO-OX
Status last verified
Aug 2016
First submitted
2 Aug 2016
Last updated
9 Aug 2016
Results posted
No
Data monitoring committee
No
Individual data sharing
Undecided

Questions about this trial

What is this clinical trial studying?

A study testing RAD57 measurement (SpCO) and CO-oximeter in people with Carbon Monoxide Poisoning, run by University Hospital, Montpellier at 1 site in France.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 3 inclusion and 2 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: status not confirmed, as of the sponsor's last update on 9 Aug 2016. Status can change between updates, so confirm with the study contact before making plans.

Where is the study taking place?

The record lists 1 site in France. Whether a site is taking part right now should be confirmed with that site. See every site.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

Results are not available in the source record.

How can a doctor refer a patient or contact the research team?

Contact Mustapha Sebbane, MD, PhD (0467337974, m-sebbane@chu-montpellier.fr), or a site near the patient. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

SpCO optimal threshold value for detection of CO poisoning (time frame: Baseline). It is what the study was designed to measure, not a finding.

Where can I read the original study information?
Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 9 Aug 2016.

Free account

Log in to keep searching

You’ve used your 3 free searches. AzTrials is free: log in or create a free account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in