Femoral Neck FractureNCT02877472
Porous Tantalum Rods Improve the Hip Joint Function of Patients With Avascular Necrosis of the Femoral Head
A study testing porous tantalum rod and core decompression in people with Femoral Neck Fracture, run by Qinghai University at 1 site in China.
Trial summary
To confirm 1) whether, compared with core decompression alone, core decompression with porous tantalum rod implantation improves the hip joint function of patients with avascular necrosis of the femoral head after femoral neck fracture surgery, 2) whether porous tantalum rod shows favorable biocompatibility with the… Read more about this study
- Who is it for?
- Ages 18 to 80 years
- Conditions the study is for
- Femoral Neck Fracture
- What is being tested?
- porous tantalum rod and core decompression
- Type of treatment
- Medical device, Surgery or procedure
- Could I receive a placebo?
- No, everyone receives an active treatment
- How many people
- 100 participants
- Where
- 1 siteChina
- Study dates
- May 2015to May 2017
- Phase
- Interventional
- Are there results?
- None posted in the registry
Key requirements
Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.
- Ages 18 to 80 years
- All sexes
- No healthy volunteers
- Adult, Older adult
Who may be able to join
- Patients with fracture nonunion as indicated by a clear fracture line 12 months after femoral neck fracture; avascular necrosis of the femoral head as shown by cystic degeneration, sclerosis, and uneven density on X-ray images and CT scans
- Patients with avascular necrosis of the femoral head after femoral neck fracture surgery who underwent internal fixation between 1 January 2016 and 31 May 2017
- Age 18-80 years
- Any sex and nationality
- Provision of signed informed consent to participate in the trial
Who cannot join
- Poor general health
- Chronic disease or history of surgery
- Alcohol abuse or long-term use of hormone drugs
- Unable or declines to cooperate with treatment and examination because of language and/or mental disorders
- Unable or declines to cooperate with rehabilitation treatment because of mental and/or psychological disorders
Trial locations and contacts
1 site in 1 country.
China1 site, 1 recruiting
- Recruiting
Qinghai University Affiliated Hospital
Xining, Qinghai, 810001
Heling Zhang, Master, 8613997262938, helingzhang_qu@sina.com
About this study
Official title: Porous Tantalum Rods Improve the Hip Joint Function of Patients With Avascular Necrosis of the Femoral Head After Femoral Neck Fracture Surgery: a Randomized Controlled Trial
To confirm 1) whether, compared with core decompression alone, core decompression with porous tantalum rod implantation improves the hip joint function of patients with avascular necrosis of the femoral head after femoral neck fracture surgery, 2) whether porous tantalum rod shows favorable biocompatibility with the human body, and 3) whether this treatment method is feasible for treating avascular necrosis of the femoral head after femoral neck fracture surgery.
Read the detailed description
History and current status of related studies: Femoral neck fracture can render the blood supply to the femoral head insufficient, leading to avascular necrosis of the femoral head. This often increases treatment difficulty and can have a strong influence on the recovery of hip joint function. Although core decompression for treatment of avascular necrosis of the femoral head has been largely used in clinical settings, the mid-term therapeutic effects are not satisfactory in some patients.
Biocompatibility is defined as the ability of a biomaterial, prosthesis, or medical device to perform with an appropriate host response. The biocompatibility of a bone implant and host influences the therapeutic effects. Therefore, biomaterials that are less likely to induce negative host responses may increase the therapeutic effects of such treatments for orthopedic diseases. A porous tantalum rod is a bone trabecula-like metal implant that is used to support weight-bearing areas of necrotic bone, preventing further collapse of the necrotic area. This implant has exhibited favorable effects in the early treatment of avascular necrosis of the femoral head. Although previous reports have focused on porous tantalum rod implantation for clinical treatment of avascular necrosis of the femoral head after fermoral neck fracture, few have assessed the long-term therapeutic effects or biocompatibility of porous tantalum rods.
Adverse events Possible adverse events include any expected or unexpected symptoms. If severe adverse events occur, information including the date of occurrence and measures taken related to the treatment of the adverse events will be reported to the principal investigator and the institutional review board within 24 hours.
Data collection, management, analysis, and open access Data collection: Case report forms with demographic data, disease diagnosis, accompanying diseases, drug allergy history, and adverse events will be collected , processed using Epidata software, collated, and then electrically recorded using a double-data entry strategy by data managers.
Data management: The locked electronic database will not be altered in any way, and will only be available to the project manager. Paper and electronic data regarding screening, informed consent, and clinical outcomes will be preserved at the Affiliated Hospital of Nantong University, China.
Data analysis: The electronic database will be made available to a professional statistician for statistical analysis. An outcome analysis report will be made by the statistician and submitted to the lead researchers. An independent data monitoring committee will supervise and manage the trial data with the goal of ensuring a scientific and stringent trial process, resulting in accurate and complete data.
Data open access: Anonymized trial data will be published at http://www.figshare.com.
Statistical analysis Statistical analysis will be performed by a statistician using SPSS 19.0 software and will follow the intention-to-treat principle. Normally distributed measurement data will be expressed as a mean, standard deviation, min, and max. Non-normally distributed measurement data will be expressed as a lower quartile (q1), median, and upper quartile (q3). McNemar's test will be used to compare the percentage of patients with excellent hip joint function as per Harris hip scores 12 months after surgery, the percentage of patients presenting with femoral head collapse, prosthesis loosening, peri-prosthesis infection, and incidence of complications 6 and 12 months after surgery. The Mann-Whitney U test will be used to compare the VAS score prior to and 1, 6, and 12 months after surgery. Statistical significance will be accepted when α = 0.05.
- Conditions
- Femoral Neck Fracture
- Being tested
- porous tantalum rod, core decompression
- Medical subject headings
- Femoral Neck Fractures
What participants receive
What participants receive. In a randomised study each person is assigned to one group by chance.
porous tantalum rodDevice
Also called Experimental group
Patients with avascular necrosis of the femoral head after femoral head fracture surgery receive treatment of core decompression and porous tantalum rod implantation
core decompressionProcedure or surgery
Also called Control group
Patients with avascular necrosis of the femoral head after femoral head fracture surgery will undergo core decompression.
| Study group | Role | What they receive |
|---|---|---|
| Experimental group | Experimental | Patients with avascular necrosis of the femoral head after femoral neck fracture surgery will undergo core decompression and porous tantalum rod implantation (experimental group). Receives: Device: porous tantalum rod |
| Control group | Experimental | Patients with avascular necrosis of the femoral head after femoral neck fracture surgery will undergo core decompression (control group). Receives: Procedure: core decompression |
What is being measured
The primary outcome is the main question the study is designed to answer.
Harris hip scores
To evaluate the recovery of hip joint function. The Harris hip score ranges from 0-100 points with higher scores indicating better hip joint function. Hip joint function is scored as follows: ≥ 90 is excellent, 80-89 very good, 70-79 good, and < 70 poor.
Measured: 12 months after surgery
Secondary outcomes (2)
Visual Analogue Scale (VAS)
To evaluate the severity of pain and ranges from 0-10, with higher scores indicating more severe pain.
Measured: prior to and 1, 6, and 12 months after surgery
Incidences of complications
To evaluate the safety of various implantation methods.
Measured: 6 and 12 months after surgery
Timeline
From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.
- First posted24 Aug 2016 (estimated)
- Study startMay 2015
- Primary completionOct 2016 (estimated)
- Study completionMay 2017 (estimated)
Resources
- Official record on ClinicalTrials.govThe registry entry this page is built from, with its full change history.
- Other trials for Femoral Neck FractureStudies of the same condition, open and under way.
- What the trial phases meanHow a treatment moves from first tests in people to approval.
More details
For doctors and researchers: how the study is designed, who runs it, and its registry IDs.
Study design
- Study type
- Interventional
- Phase
- Phase N/A
- Primary purpose
- Treatment
- Allocation
- Randomised
- Intervention model
- Parallel groups
- Masking
- None (open label)
- Enrolment
- 100 participants (estimated)
Sponsor and investigators
- Lead sponsor
- Qinghai University
- Sponsor type
- University, hospital or other
- Responsible party
- Principal investigator, Heling Zhang, Qinghai University
- Investigators
- Heling Zhang, Master, Principal investigator, Affiliated Hospital of Qinghai University
IDs, dates and publications
- ClinicalTrials.gov ID
- NCT02877472
- Sponsor's protocol ID
- QinghaiUH_003
- Status last verified
- Aug 2016
- First submitted
- 19 Aug 2016
- Last updated
- 24 Aug 2016
- Results posted
- No
- Data monitoring committee
- Yes
- Individual data sharing
- Undecided
Study at a glance
From the registry record, last updated by the sponsor on 24 Aug 2016. Recruitment status is as the sponsor reported it: confirm with the study team.
- Official title
- Porous Tantalum Rods Improve the Hip Joint Function of Patients With Avascular Necrosis of the Femoral Head After Femoral Neck Fracture Surgery: a Randomized Controlled Trial
- ClinicalTrials.gov ID
- NCT02877472
- Acronym / sponsor ID
- QinghaiUH_003
- Conditions
- Femoral Neck Fracture
- Study type
- Interventional
- Recruitment status
- Unknown status
- Enrolment
- 100 participants (estimated)
- Lead sponsor
- Qinghai UniversityUniversity, hospital or other
- Study start
- May 2015
- Primary completion
- Oct 2016 (estimated)
- Study completion
- May 2017 (estimated)
- First posted
- 24 Aug 2016 (estimated)
- Results
- Not posted in the source record
Clinical summary
The research question as the sponsor registered it. This describes what the study plans to test, not what it found.
To confirm 1) whether, compared with core decompression alone, core decompression with porous tantalum rod implantation improves the hip joint function of patients with avascular necrosis of the femoral head after femoral neck fracture surgery, 2) whether porous tantalum rod shows favorable biocompatibility with the human body, and 3) whether this treatment method is feasible for treating avascular necrosis of the femoral head after femoral neck fracture surgery.
Detailed description
History and current status of related studies: Femoral neck fracture can render the blood supply to the femoral head insufficient, leading to avascular necrosis of the femoral head. This often increases treatment difficulty and can have a strong influence on the recovery of hip joint function. Although core decompression for treatment of avascular necrosis of the femoral head has been largely used in clinical settings, the mid-term therapeutic effects are not satisfactory in some patients.
Biocompatibility is defined as the ability of a biomaterial, prosthesis, or medical device to perform with an appropriate host response. The biocompatibility of a bone implant and host influences the therapeutic effects. Therefore, biomaterials that are less likely to induce negative host responses may increase the therapeutic effects of such treatments for orthopedic diseases. A porous tantalum rod is a bone trabecula-like metal implant that is used to support weight-bearing areas of necrotic bone, preventing further collapse of the necrotic area. This implant has exhibited favorable effects in the early treatment of avascular necrosis of the femoral head. Although previous reports have focused on porous tantalum rod implantation for clinical treatment of avascular necrosis of the femoral head after fermoral neck fracture, few have assessed the long-term therapeutic effects or biocompatibility of porous tantalum rods.
Adverse events Possible adverse events include any expected or unexpected symptoms. If severe adverse events occur, information including the date of occurrence and measures taken related to the treatment of the adverse events will be reported to the principal investigator and the institutional review board within 24 hours.
Data collection, management, analysis, and open access Data collection: Case report forms with demographic data, disease diagnosis, accompanying diseases, drug allergy history, and adverse events will be collected , processed using Epidata software, collated, and then electrically recorded using a double-data entry strategy by data managers.
Data management: The locked electronic database will not be altered in any way, and will only be available to the project manager. Paper and electronic data regarding screening, informed consent, and clinical outcomes will be preserved at the Affiliated Hospital of Nantong University, China.
Data analysis: The electronic database will be made available to a professional statistician for statistical analysis. An outcome analysis report will be made by the statistician and submitted to the lead researchers. An independent data monitoring committee will supervise and manage the trial data with the goal of ensuring a scientific and stringent trial process, resulting in accurate and complete data.
Data open access: Anonymized trial data will be published at http://www.figshare.com.
Statistical analysis Statistical analysis will be performed by a statistician using SPSS 19.0 software and will follow the intention-to-treat principle. Normally distributed measurement data will be expressed as a mean, standard deviation, min, and max. Non-normally distributed measurement data will be expressed as a lower quartile (q1), median, and upper quartile (q3). McNemar's test will be used to compare the percentage of patients with excellent hip joint function as per Harris hip scores 12 months after surgery, the percentage of patients presenting with femoral head collapse, prosthesis loosening, peri-prosthesis infection, and incidence of complications 6 and 12 months after surgery. The Mann-Whitney U test will be used to compare the VAS score prior to and 1, 6, and 12 months after surgery. Statistical significance will be accepted when α = 0.05.
Study design
- Primary purpose
- Treatment
- Allocation
- Randomised
- Intervention model
- Parallel groups
- Masking
- None (open label)
- Number of arms
- 2
| Arm | Type | Receives |
|---|---|---|
| Experimental group | Experimental | Device: porous tantalum rodPatients with avascular necrosis of the femoral head after femoral neck fracture surgery will undergo core decompression and porous tantalum rod implantation (experimental group). |
| Control group | Experimental | Procedure: core decompressionPatients with avascular necrosis of the femoral head after femoral neck fracture surgery will undergo core decompression (control group). |
Who may qualify
- Ages
- 18 to 80 years
- Sex
- All
- Healthy volunteers
- Not accepted
- Age groups
- Adult, Older adult
Key inclusion criteria (5 listed)
- Patients with fracture nonunion as indicated by a clear fracture line 12 months after femoral neck fracture; avascular necrosis of the femoral head as shown by cystic degeneration, sclerosis, and uneven density on X-ray images and CT scans
- Patients with avascular necrosis of the femoral head after femoral neck fracture surgery who underwent internal fixation between 1 January 2016 and 31 May 2017
- Age 18-80 years
- Any sex and nationality
- Provision of signed informed consent to participate in the trial
Key exclusion criteria (5 listed)
- Poor general health
- Chronic disease or history of surgery
- Alcohol abuse or long-term use of hormone drugs
- Unable or declines to cooperate with treatment and examination because of language and/or mental disorders
- Unable or declines to cooperate with rehabilitation treatment because of mental and/or psychological disorders
Eligibility is decided by the study team after screening; this overview does not establish that a patient qualifies. Full inclusion and exclusion criteria.
Interventions
| Intervention | Type | Arms |
|---|---|---|
| porous tantalum rodAlso: Experimental groupPatients with avascular necrosis of the femoral head after femoral head fracture surgery receive treatment of core decompression and porous tantalum rod implantation | Device | Experimental group |
| core decompressionAlso: Control groupPatients with avascular necrosis of the femoral head after femoral head fracture surgery will undergo core decompression. | Procedure or surgery | Control group |
Primary outcome
Harris hip scores
Time frame: 12 months after surgery
To evaluate the recovery of hip joint function. The Harris hip score ranges from 0-100 points with higher scores indicating better hip joint function. Hip joint function is scored as follows: ≥ 90 is excellent, 80-89 very good, 70-79 good, and < 70 poor.
2 secondary outcomes
Visual Analogue Scale (VAS)
Time frame: prior to and 1, 6, and 12 months after surgery
Incidences of complications
Time frame: 6 and 12 months after surgery
Results and safety
Results are not available in the source record.
Research links
- Official record on ClinicalTrials.govLast updated by the sponsor 24 Aug 2016.
- Individual participant dataSharing planned: Undecided
Related trials for Femoral Neck Fracture
Active, not recruiting
Lumbar-Sacral Plexus Block vs Fascia Iliaca Block Plus Low-Dose Spinal Anesthesia for Femoral Neck Fracture Surgery
Femoral Neck Fractures, Nerve Block
Not yet recruiting
Lumbar Erector Spinae Plane Block Versus PENG Block for Hip Fracture Surgery
Femur Neck Fracture, Hip Fractures
Active, not recruitingPhase 2
BDSF Vs DHS With Anterotational Screw in Vertical FNF
Evaluation of BDSF in FNF
RecruitingObservational study
Z1 Hip System: Post-Market Clinical Follow Up Study
Hip Osteoarthritis, Acute Traumatic Fracture of the Femoral Head or Neck
Not yet recruiting
Trochanteric Bursa Repair and Lateral Hip Pain After Hemiarthroplasty for Femoral Neck Fracture
Femoral Neck Fracture
Referral and contact
AzTrials does not enrol participants or take referrals. Contact the study team or a site listed below; they decide who can take part. This study is not recruiting at the moment.
Heling Zhang, Master principal investigator
Affiliated Hospital of Qinghai University
1 site in 1 country: see every site and its status.
Questions about this trial
What is this clinical trial studying?
A study testing porous tantalum rod and core decompression in people with Femoral Neck Fracture, run by Qinghai University at 1 site in China.
The full registered description is in the About this study section and the official record.
Who may be eligible to take part?
The sponsor lists 5 inclusion and 5 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.
Is this clinical trial currently recruiting?
The record says: status not confirmed, as of the sponsor's last update on 24 Aug 2016. Status can change between updates, so confirm with the study contact before making plans.
Where is the study taking place?
The record lists 1 site in China. Whether a site is taking part right now should be confirmed with that site. See every site.
What are the possible benefits and risks?
They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.
Are results available for this study?
Results are not available in the source record.
How can a doctor refer a patient or contact the research team?
Contact Heling Zhang, Master (8613997262938, helingzhang_qu@sina.com), or a site near the patient. AzTrials does not enrol participants or take referrals.
What does the primary outcome measure?
Harris hip scores (time frame: 12 months after surgery). It is what the study was designed to measure, not a finding.
Where can I read the original study information?
Does a listing mean the treatment is approved or proven to work?
No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.
How often is this information updated?
AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 24 Aug 2016; AzTrials last refreshed its copy on 7 Nov 2026.