Hemodynamic Study With PRAM of the Cardiovascular Response to the Positioning of the Extraglottic Device

A study testing airway management in people with Intubation Complication and Hemodynamic Instability, run by Azienda Ospedaliero-Universitaria Careggi.

Unknown status

Status not confirmed. The sponsor has not verified this record for over two years, so it may be out of date.

Official record
Search all trials

Trial summary

The purpose of the study will be to record the hemodynamic response measured by traditional methods (non-invasive blood pressure and ECG) and Pressure Recording Analytical Method in patients undergoing laryngeal mask placement compared with the hemodynamic response measured in patients undergoing laryngoscopy and… Read more about this study

Who is it for?
Ages 18 to 50 years, women only
What is being tested?
airway management
Type of treatment
Medical device
Could I receive a placebo?
No, everyone receives an active treatment
How many people
94 participants
Where
No sites listed yet
Study dates
Oct 2016to Jun 2017
Phase
Interventional
Are there results?
None posted in the registry

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 18 to 50 years
  • Women only
  • No healthy volunteers
  • Adult

Who may be able to join

  • Patients scheduled for elective gynecological surgery under general anesthesia
  • Age >18 <50 years
  • Presence of informed consent in the clinical record
  • Belonging to risk classes ASA 1 - ASA 2

Who cannot join

  • Hypertension
  • Heart failure
  • Treatment with beta blockers, Ca channel blockers, antihypertensives, vagolytic
  • Hypo/hyperthyroidism and its treatment
  • Adrenal insufficiency and its treatment
  • Autonomic neuropathy

Trial locations and contacts

No sites are listed yet.

Alessandro Di Filippo, MD contact

3397219337 ext. +39

adifilippo@unifi.it

Massimo Micaglio, MD contact

3357766532 ext. +39

m.micaglio@gmail.com

About this study

Official title: Hemodynamic Study With Pressure Recording Analytical Method (PRAM) of the Cardiovascular Response to the Positioning of the Extraglottic Device in Gynecological Surgery

The purpose of the study will be to record the hemodynamic response measured by traditional methods (non-invasive blood pressure and ECG) and Pressure Recording Analytical Method in patients undergoing laryngeal mask placement compared with the hemodynamic response measured in patients undergoing laryngoscopy and tracheal intubation for performing surgery in gynecological area and assess the differences with the two methods.

Read the detailed description

Introduction Laryngoscopy and tracheal intubation may cause significant hemodynamic changes in the patient and induce cardiovascular complications.

Numerous studies have sought methods to reduce this risk (1-5). The extraglottic not involving either laryngoscopy or their passage through the vocal cords, have proven protective of the possible cardiovascular complications resulting from the placement of respiratory prosthesis (6,7).

Measurements of hemodynamic changes resulting from the procedures for airway management with extraglottic have not previously been carried out.

The MostCare (Vytech, Vygon Italia srl, Padova, Italy) is a monitor provided for more than 10 years at the obstetric gynecological anesthesia unit able to evaluate the hemodynamic changes in a patient based on the Pressure Recording Analytical Method (PRAM).

This is a measurement method of the cardio-circulatory performance of a patient that does not require calibration and / or insertion of a pre-estimated data because the method of analysis of the wave form of the arterial pressure is developed completely a priori (8). The measurement derives from the simultaneous analysis of the components of a pulsatile flow and the continuous flow as a ratio between the area under the curve of the pulsatile portion of the systolic pressure and the characteristic impedance Z (t). The PRAM method has proven effective in many clinical settings (9).

The Medical Device (DM) will be used in accordance with the indications of use for which it has acquired the CE mark. A morphology detection system linked to high blood pressure curve detected through non-invasive Masimo oximetry system supplied to the Hospital will be used Purpose of the study The purpose of the research will be to record the hemodynamic response measured by traditional methods (non-invasive blood pressure and ECG) and PRAM method in patients undergoing placement laryngeal mask compared with the hemodynamic response measured in patients undergoing laryngoscopy and tracheal intubation for performing surgery in gynecological area and assess the differences with the two methods

Methods This will be a prospective observational study. Data will be collected from all consecutive patients undergoing general anesthesia for gynecologic surgery for a period of 3 months or until the minimum number of 94 patients (see section statistical analysis).

In the operating room the patient will undergo to active pre-warming with hot air, peripheral venous cannulation and premedication with midazolam 0,04 mg/kg, and fentanyl 1.5 mcg/kg body weight. After the positioning of the standard monitoring systems (ECG, Non-Invasive Blood Pressure, Pulseoximetry, Neuromuscular Transmission), the signal from the Pulseoximetry will also be analyzed by the MostCare monitoring system that allows to apply the measuring method PRAM noninvasively.

After 3 minutes of high flows O2, propofol 2 mg/kg body weight and rocuronium 0.9 mg/kg body weight will be administered sequentially to the patient. Anesthesia will be maintained with propofol continuous infusion (9-12 mg/kg body weight /hour) and remifentanil continuous infusion (0.2 mcg/kg body weight /minute ). At the disappearance of the adductor muscle response to electrical stimulation of the thumb "Train of four" (TOF) applied to the ulnar nerve the positioning maneuver of the respiratory device will be performed:

  • with direct laryngoscopy in the case of endotracheal intubation
  • with direct insertion in the case of laryngeal mask placement. Proper placement will be evaluated by chest auscultation, spirometry and analysis of the concentration and the carbon dioxide curve in exhaled gases.

The data obtained from the PRAM and the usual monitoring will be recorded on a special sheet by an outside observer.

In the case of failed positioning of the respiratory device, the procedure will be repeated and in case of further failure will proceed as indicated by national and hospital guidelines (10), but the patient will still be excluded from the study ..

The choice of the respiratory device will depend on the type of intervention scheduled in the operating program.

The hemodynamic and monitoring data will be recorded every minute for 5 minutes for each patient.

The study duration will be 3 months (or in any case until reaching the minimum number of 94 cases).

The patients will be divided, retrospectively, in two groups according to the type of device used for airway management.

The two groups will be compared on the basis of age and anthropometric parameters. An analysis of the hemodynamic response of the two groups of patients to the positioning of the respiratory device will then conduct.

Statistical analysis A recent study (11), that analyzed the cardiac index changes in response to tracheal intubation with laryngoscope Mcintosh in comparison to the video laryngoscope laryngoscopy, showed a difference of 1 L/min/m2 (from 3.1±0.6 to 4.3±1.4 with laryngoscope McIntosh vs 3.0±0.3 to 3.2 ± 1.1 with videolaryngoscope).

Therefore, to test the hypothesis that the cardiac index difference using the airway management with traditional intubation compared to the use of the laryngeal mask is greater than or equal to 1 L/min/m2, having fixed the first type error to the 5% and the study power to 80%, it is possible to calculate that the sample size needed for a one-tailed test is represented by 47 patients per group.

The average of the data collected in each group of patients will be compared with Student's t test.

Expected results To verify, in two of homogeneous population groups for anthropometric and clinical data, the least impact on the cardiovascular system produced by the placement of laryngeal mask compared to that induced by endotracheal intubation with conventional laryngoscopy taking advantage of non-invasive hemodynamic monitoring system of the pulse oximetry MostCare (methodology PRAM) ever tested in this field.

Also to check the hemodynamic impact of any repeated attempts to both of the above maneuvers for airway management.

Ownership of the results will be accredited by the principal investigator on behalf of the AOU Careggi and the University of Florence as headings of him which has neither received nor will receive any fee for the conduct of the study.

Being tested
airway management
Keywords
Laryngeal masks

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • airway managementDevice

    airway management with Laryngeal Mask or Oro Tracheal Intubation

Study groups in NCT02918526
Study groupRoleWhat they receive
Laryngeal MaskExperimentallaryngeal mask (LMA)
Receives: Device: airway management
Oro Tracheal IntubationActive comparatororo tracheal intubation
Receives: Device: airway management

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. Cardiac Index (L/min/m2)

    Cardiac Index (L/min/m2) measured with Pulse Recording Analytic Method

    Measured: for 5 minutes after induction of anesthesia

Secondary outcomes (8)
  1. Heart rate (bpm)

    Measured: for 5 minutes after induction of anesthesia

  2. Blood pressure (mmHg)

    Measured: for 5 minutes after induction of anesthesia

  3. Cardiac Output (CO) (L/min)

    Measured: for 5 minutes after induction of anesthesia

  4. Stroke Volume (SV) (ml/beat)

    Measured: for 5 minutes after induction of anesthesia

  5. Stroke Volume Index (SVI) (ml/beat /m2)

    Measured: for 5 minutes after induction of anesthesia

  6. Systemic Vascular Resistance (SVR) (dynes•s /cm5)

    Measured: for 5 minutes after induction of anesthesia

  7. Cardiac Cycle Efficiency (CCE) (a dimensional value)

    Measured: for 5 minutes after induction of anesthesia

  8. Cardiac Power Output (CPO) (W).

    Measured: for 5 minutes after induction of anesthesia

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted29 Sep 2016 (estimated)
  2. Study startOct 2016
  3. Primary completionMar 2017 (estimated)
  4. Study completionJun 2017 (estimated)

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Interventional
Phase
Phase N/A
Primary purpose
Prevention
Allocation
Randomised
Intervention model
Parallel groups
Masking
None (open label)
Enrolment
94 participants (estimated)
IDs, dates and publications
ClinicalTrials.gov ID
NCT02918526
Sponsor's protocol ID
AOUCareggi
Status last verified
Sep 2016
First submitted
24 Sep 2016
Last updated
29 Sep 2016
Results posted
No
Data monitoring committee
Yes
Individual data sharing
Yes

Publications

  • Efe EM, Bilgin BA, Alanoglu Z, Akbaba M, Denker C. Comparison of bolus and continuous infusion of esmolol on hemodynamic response to laryngoscopy, endotracheal intubation and sternotomy in coronary artery bypass graft. Braz J Anesthesiol. 2014 Jul-Aug;64(4):247-52. doi: 10.1016/j.bjane.2013.07.003. Epub 2013 Oct 25.

    PubMed 24998108
  • Lee SY, Min JJ, Kim HJ, Hong DM, Kim HJ, Park HP. Hemodynamic effects of topical lidocaine on the laryngoscope blade and trachea during endotracheal intubation: a prospective, double-blind, randomized study. J Anesth. 2014 Oct;28(5):668-75. doi: 10.1007/s00540-014-1812-z. Epub 2014 Mar 12.

    PubMed 24619576
  • Daabiss M, Hashish M. Effects of lornoxicam on the hemodynamic and catecholamine response to laryngoscopy and tracheal intubation. Eur J Clin Pharmacol. 2011 Aug;67(8):783-6. doi: 10.1007/s00228-011-1017-4. Epub 2011 Mar 3.

    PubMed 21369950
  • Min JH, Chai HS, Kim YH, Chae YK, Choi SS, Lee A, Choi YS. Attenuation of hemodynamic responses to laryngoscopy and tracheal intubation during rapid sequence induction: remifentanil vs. lidocaine with esmolol. Minerva Anestesiol. 2010 Mar;76(3):188-92.

    PubMed 20203546
  • Sun HL, Wu TJ, Ng CC, Chien CC, Huang CC, Chie WC. Efficacy of oropharyngeal lidocaine instillation on hemodynamic responses to orotracheal intubation. J Clin Anesth. 2009 Mar;21(2):103-7. doi: 10.1016/j.jclinane.2008.06.028.

    PubMed 19329013
  • Perello-Cerda L, Fabregas N, Lopez AM, Rios J, Tercero J, Carrero E, Hurtado P, Hervias A, Gracia I, Caral L, de Riva N, Valero R. ProSeal Laryngeal Mask Airway Attenuates Systemic and Cerebral Hemodynamic Response During Awakening of Neurosurgical Patients: A Randomized Clinical Trial. J Neurosurg Anesthesiol. 2015 Jul;27(3):194-202. doi: 10.1097/ANA.0000000000000108.

    PubMed 25121397
  • Agrawal G, Agarwal M, Taneja S. A randomized comparative study of intraocular pressure and hemodynamic changes on insertion of proseal laryngeal mask airway and conventional tracheal intubation in pediatric patients. J Anaesthesiol Clin Pharmacol. 2012 Jul;28(3):326-9. doi: 10.4103/0970-9185.98325.

    PubMed 22869938
  • Romano SM, Pistolesi M. Assessment of cardiac output from systemic arterial pressure in humans. Crit Care Med. 2002 Aug;30(8):1834-41. doi: 10.1097/00003246-200208000-00027.

    PubMed 12163802
  • Scolletta S, Romano SM, Biagioli B, Capannini G, Giomarelli P. Pressure recording analytical method (PRAM) for measurement of cardiac output during various haemodynamic states. Br J Anaesth. 2005 Aug;95(2):159-65. doi: 10.1093/bja/aei154. Epub 2005 May 13.

    PubMed 15894561
  • Petrini F, Accorsi A, Adrario E, Agro F, Amicucci G, Antonelli M, Azzeri F, Baroncini S, Bettelli G, Cafaggi C, Cattano D, Chinelli E, Corbanese U, Corso R, Della Puppa A, Di Filippo A, Facco E, Favaro R, Favero R, Frova G, Giunta F, Giurati G, Giusti F, Guarino A, Iannuzzi E, Ivani G, Mazzon D, Menarini M, Merli G, Mondello E, Muttini S, Nardi G, Pigna A, Pittoni G, Ripamonti D, Rosa G, Rosi R, Salvo I, Sarti A, Serafini G, Servadio G, Sgandurra A, Sorbello M, Tana F, Tufano R, Vesconi S, Villani A, Zauli M; Gruppo di Studio SIAARTI "Vie Aeree Difficili"; IRC e SARNePI; Task Force. Recommendations for airway control and difficult airway management. Minerva Anestesiol. 2005 Nov;71(11):617-57. No abstract available. English, Italian.

    PubMed 16278626
  • Abdelgawad AF, Shi QF, Halawa MA, Wu ZL, Wu ZY, Chen XD, Yao SL. Comparison of cardiac output and hemodynamic responses of intubation among different videolaryngoscopies in normotensive and hypertensive patients. J Huazhong Univ Sci Technolog Med Sci. 2015 Jun;35(3):432-438. doi: 10.1007/s11596-015-1449-7. Epub 2015 Jun 14.

    PubMed 26072085

Questions about this trial

What is this clinical trial studying?

A study testing airway management in people with Intubation Complication and Hemodynamic Instability, run by Azienda Ospedaliero-Universitaria Careggi.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 4 inclusion and 6 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: status not confirmed, as of the sponsor's last update on 29 Sep 2016. Status can change between updates, so confirm with the study contact before making plans.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

Results are not available in the source record.

How can a doctor refer a patient or contact the research team?

Contact Alessandro Di Filippo, MD (3397219337 ext. +39, adifilippo@unifi.it), or a site near the patient. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

Cardiac Index (L/min/m2) (time frame: for 5 minutes after induction of anesthesia). It is what the study was designed to measure, not a finding.

Where can I read the original study information?

On the ClinicalTrials.gov record for NCT02918526, which also lists 11 linked publications.

Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 29 Sep 2016.

Free account

Log in to keep searching

You’ve used your 3 free searches. AzTrials is free: log in or create a free account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in