Pulmonary vein (PV) isolation is very important in atrial fibrillation (AF) catheter ablation. PV reconnection is one of the main reasons in AF recurrence. Contact force-sensing catheter is a new catheter which has valuable tools to monitor and increase the efficacy of PV isolation. Read more about this study

Who is it for?
Ages 18 to 80 yearsHealthy volunteers can take part
Conditions the study is for
Atrial Fibrillation
What is being tested?
SmartTouch Catheter
Type of treatment
Medical device
Could I receive a placebo?
No, everyone receives an active treatment
How many people
60 participants
Where
1 siteSouth Korea
Study dates
Jun 2015to 11 Oct 2018
Phase
Interventional
Are there results?
None posted in the registry

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 18 to 80 years
  • All sexes
  • Healthy volunteers accepted
  • Adult, Older adult

Who may be able to join

  • Patients with symptomatic paroxysmal atrial fibrillation (AF) who had failed with anti-arrhythmic agents.

Who cannot join

  • Patients who had previous ablation for AF
  • Patients with symptomatic persistent AF

Trial locations and contacts

1 site in 1 country.

South Korea1 site
  • Seoul National University Hospital

    Seoul, 03080

Other trials in South Korea

About this study

Official title: Comparison of Acute Pulmonary Vein (PV) Reconnection Between Contact Force Guided and Blinded PV Isolation in Patients With Symptomatic Atrial Fibrillation

Pulmonary vein (PV) isolation is very important in atrial fibrillation (AF) catheter ablation. PV reconnection is one of the main reasons in AF recurrence. Contact force-sensing catheter is a new catheter which has valuable tools to monitor and increase the efficacy of PV isolation. Previous paper reported the efficacy of contact force-sensing catheter on immediate PV isolation and outcome. However, there might be confounding factor as inter-individual variation. Therefore, we would like to compare the efficacy of contact force-sensing catheter within same patient but different veins.

In this study, we would like to confirm the efficacy of contact force-sensing catheter on immediate PV isolation outcome within same patient. This study randomized the right or left PVs whether to use the contact force-sensing function or not. The study design will minimize the inter-individual variation on evaluating the efficacy of contact force-sensing catheter on immediate PV isolation.

Also, in patients who had recurred AF or AT, we would like to evaluate the long-term efficacy of contact force-sensing catheter on PV isolation.

Read the detailed description

Sixty patients will be randomized to select right or left pulmonary veins whether to apply contact force-guided ablation or contact force-blinded ablation strategy. Each PV will be ablated with same contact force-sensing catheter (Thermocool Smart Touch Catheter, Biosense Webster Inc. CA). The PV (right or left) which will be randomized to contact force-sensing PV or blind PV. Contact force-sensing PV will be ablated guided by contact force, whereas the blind PVs will be ablated without contact force-sensing information. The change of impedance, total ablation and time to ablate PV will be collected and analysed according to contact force-sensing strategy. After exit and entrance block by conventional method, dormant conduction will be evaluated by using adenosine. The proportion of dormant conduction will be compared between contact force-sensing guided or blinded strategy.

During 1-year follow up, patients who recurred AF or AT will be undergo second ablation procedure. In these patients, PV reconnection rate will be evaluated by a duodecapolar lasso circular mapping catheter. We would like to know whether PVs which have ablated with contact force-sensing information at index procedure have less reconnection than those which was ablated without contact force-sensing information.

Being tested
SmartTouch Catheter
Keywords
pulmonary vein isolation, contact force sensing catheter
Medical subject headings
Atrial Fibrillation

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • SmartTouch CatheterDevice

    Also called Contact force guided pulmonary vein isolation

    Pulmonary vein (PV) isolation guided by CF information

Study groups in NCT02924181
Study groupRoleWhat they receive
Lt PV CF guided/rt PV CF blindedActive comparatorFifteen patients will be allocated to this group. Left side pulmonary veins isolation will be performed with contact force information guidance. Then, right side pulmonary veins isolation will be performed without contact force information (using same catheter named SmartTouch Catheter).
Receives: Device: SmartTouch Catheter
Lt PV CF blinded/rt PV CF guidedActive comparatorFifteen patients will be allocated to this group. Left side pulmonary veins isolation will be performed without contact force information (using same catheter named SmartTouch Catheter).Then, right side pulmonary veins isolation will be performed with contact force information guidance.
Receives: Device: SmartTouch Catheter
Rt PV CF guided/lt PV CF blindedActive comparatorFifteen patients will be allocated to this group. Right side pulmonary veins isolation will be performed with contact force information guidance. Then, left side pulmonary veins isolation will be performed without contact force information (using same catheter named SmartTouch Catheter).
Receives: Device: SmartTouch Catheter
Rt PV CF blinded/lt PV CF guidedActive comparatorFifteen patients will be allocated to this group. Right side pulmonary veins isolation will be performed without contact force information (using same catheter named SmartTouch Catheter). Then, left side pulmonary veins isolation will be performed with contact force information guidance.
Receives: Device: SmartTouch Catheter

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. Proportion of immediate PV isolation ratio after final ablation according to contact force-guided ablation, change of impedance, total ablation time, and procedure time according to contact force-guided strategy

    Measured: Immediate after PV isolation (acute result)

Secondary outcomes (1)
  1. Proportion of PV reconnection according to contact force-guided ablation in patients with AF recurrence

    Measured: 1 year

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted5 Oct 2016 (estimated)
  2. Study startJun 2015
  3. Primary completion23 Oct 2017
  4. Study completion11 Oct 2018

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Interventional
Phase
Phase N/A
Primary purpose
Treatment
Allocation
Randomised
Intervention model
Parallel groups
Masking
None (open label)
Enrolment
60 participants (actual)
IDs, dates and publications
ClinicalTrials.gov ID
NCT02924181
Sponsor's protocol ID
SNUH
Status last verified
Mar 2020
First submitted
19 May 2016
Last updated
18 Mar 2020
Results posted
No
Data monitoring committee
No
Individual data sharing
Yes

Publications

  • Andrade JG, Monir G, Pollak SJ, Khairy P, Dubuc M, Roy D, Talajic M, Deyell M, Rivard L, Thibault B, Guerra PG, Nattel S, Macle L. Pulmonary vein isolation using "contact force" ablation: the effect on dormant conduction and long-term freedom from recurrent atrial fibrillation--a prospective study. Heart Rhythm. 2014 Nov;11(11):1919-24. doi: 10.1016/j.hrthm.2014.07.033. Epub 2014 Jul 25.

    PubMed 25068575
  • Natale A, Reddy VY, Monir G, Wilber DJ, Lindsay BD, McElderry HT, Kantipudi C, Mansour MC, Melby DP, Packer DL, Nakagawa H, Zhang B, Stagg RB, Boo LM, Marchlinski FE. Paroxysmal AF catheter ablation with a contact force sensing catheter: results of the prospective, multicenter SMART-AF trial. J Am Coll Cardiol. 2014 Aug 19;64(7):647-56. doi: 10.1016/j.jacc.2014.04.072.

    PubMed 25125294
  • Marijon E, Fazaa S, Narayanan K, Guy-Moyat B, Bouzeman A, Providencia R, Treguer F, Combes N, Bortone A, Boveda S, Combes S, Albenque JP. Real-time contact force sensing for pulmonary vein isolation in the setting of paroxysmal atrial fibrillation: procedural and 1-year results. J Cardiovasc Electrophysiol. 2014 Feb;25(2):130-7. doi: 10.1111/jce.12303. Epub 2013 Nov 6.

    PubMed 24433324
  • Reichlin T, Knecht S, Lane C, Kuhne M, Nof E, Chopra N, Tadros TM, Reddy VY, Schaer B, John RM, Osswald S, Stevenson WG, Sticherling C, Michaud GF. Initial impedance decrease as an indicator of good catheter contact: insights from radiofrequency ablation with force sensing catheters. Heart Rhythm. 2014 Feb;11(2):194-201. doi: 10.1016/j.hrthm.2013.10.048. Epub 2013 Oct 28.

    PubMed 24177370

Questions about this trial

What is this clinical trial studying?

A study testing SmartTouch Catheter in people with Atrial Fibrillation, run by Seoul National University Hospital at 1 site in South Korea.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 1 inclusion and 2 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: finished, as of the sponsor's last update on 18 Mar 2020. Status can change between updates, so confirm with the study contact before making plans.

Where is the study taking place?

The record lists 1 site in South Korea. Whether a site is taking part right now should be confirmed with that site. See every site.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.

How can a doctor refer a patient or contact the research team?

The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

Proportion of immediate PV isolation ratio after final ablation according to contact force-guided ablation, change of impedance, total ablation time, and procedure time according to contact force-guided strategy (time frame: Immediate after PV isolation (acute result)). It is what the study was designed to measure, not a finding.

Where can I read the original study information?

On the ClinicalTrials.gov record for NCT02924181, which also lists 4 linked publications.

Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 18 Mar 2020.

Free account

Keep searching with a free account

You’ve used your 3 free searches for this session. Log in or create a free AzTrials account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in
Clinical Trial NCT02924181 | AzTrials