Aortic StenosisNCT02950428

ACURATE Neo™ TA Delivery System in Patient With Severe Aortic Stenosis

A study testing ACURATE neo™TA Delivery System in people with Aortic Stenosis, run by Symetis SA at 7 sites in Germany.

Completed

Finished. The study has ended and is not enrolling. Results may be posted on the official record.

Official record
Search all trials

Trial summary

The purpose of this investigation is to collect data pertaining to the safety and performance of the ACURATE neo (TM) Aortic Bioprosthesis as implanted with the ACURATE neo (TM) TA Transapical Delivery System. Read more about this study

Who is it for?
Ages 18 years and older
Conditions the study is for
Aortic Stenosis
What is being tested?
ACURATE neo™TA Delivery System
Type of treatment
Medical device
Could I receive a placebo?
No, everyone receives an active treatment
How many people
60 participants
Where
7 sitesGermany
Study dates
18 Nov 2015to 3 Sep 2021
Phase
Interventional
Are there results?
None posted in the registry

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 18 years and older
  • All sexes
  • No healthy volunteers
  • Adult, Older adult

Who may be able to join

  • Subject must be at least 18 years old
  • Severe aortic stenosis defined as:
  • Mean aortic gradient > 40 mmHg or
  • Peak jet velocity > 4.0 m/s or
  • Aortic valve area of < 0.8 cm2
  • High risk patient determined by a multidisciplinary heart team consensus (cardiologist and cardiac surgeon) that patient is not a surgical candidate for conventional AVR due to risk factors such as STS Score (8% or higher) or other co-morbid conditions unrelated to aortic stenosis such as severe chronic obstructive pulmonary disease (COPD), chest deformities and irradiated mediastinum
Show all 14Show fewer
  • NYHA Functional Class > II
  • Multidisciplinary heart team (cardiologist and cardiac surgeon) consensus that the transapical approach is the most suitable access route for TAVI due to the presence of the following anatomic conditions:
  • porcelain aorta or
  • severely calcified or highly tortuous peripheral vasculature not appropriate for transfemoral transcatheter aortic valve implantation or
  • vessels too small for retrograde approach or
  • other anatomical conditions making transapical approach more suitable
  • Aortic annulus diameter from ≥ 21mm up to ≤ 27mm by CT or TEE
  • Patient willing to participate in the study and provides signed informed consent

Who cannot join

  • Congenital unicuspid or bicuspid aortic valve or non-calcified
  • Extreme eccentricity of calcification
  • Severe mitral regurgitation (> Grade 3)
  • Pre-existing prosthetic heart valve in any position and / or prosthetic ring
  • LV apex is not accessible via transapical access due to severe chest deformity
  • Previous surgery of the LV using a patch, such as the Dor procedure
Show all 31Show fewer
  • Presence of apical LV thrombus
  • Calcified pericardium
  • Septal hypertrophy unacceptable for transapical procedure
  • Transesophageal echocardiogram (TEE) is contraindicated
  • ECHO evidence of intracardiac mass, thrombus, or vegetation
  • LVEF < 20% by ECHO
  • Need for emergency intervention for any reason within 30 Days of scheduled procedure
  • Any percutaneous intervention, except for balloon valvuloplasty (BAV) within 1 month prior to implant procedure
  • Untreated clinically significant coronary artery disease requiring revascularization within 30 days before or after the study procedure
  • Acute myocardial infarction within 1 month prior to implant procedure
  • Previous TIA or stroke within 6 months prior to implant procedure
  • Active gastrointestinal (GI) bleeding within 3 months prior to implant procedure
  • Scheduled surgical or percutaneous procedure to be performed prior to 30 day visit
  • History of bleeding diathesis, coagulopathy, refusal of blood transfusions or severe anemia (Hb<8 g/dL)
  • Systolic pressure <80mmHg, cardiogenic shock, need for inotropic support or IABP
  • Primary hypertrophic obstructive cardiomyopathy (HOCM)
  • Active infection or endocarditis
  • Hepatic failure (> Child B)
  • Chronic renal dysfunction with serum creatinine > 3.0 mg/dL or renal dialysis
  • Neurological disease severely affecting ambulation, daily functioning, or dementia
  • Life expectancy < 12 months due to non-cardiac co-morbid conditions
  • Intolerance to aspirin, clopidogrel, contrast media, or porcine tissue and allergy to nickel
  • Pregnant or breast-feeding women
  • For other severe illnesses of the patient (e.g. active carcinoma), the investigator shall decide on an individual basis whether the patient is not to be included in the study
  • Currently participating in an investigational drug or another device study

Trial locations and contacts

7 sites in 1 country.

7 sites in 1 country

Germany7 sites
  • Kerckhoff-Klinik

    Bad Nauheim, 61231

  • Krankenhausbetriebsgesellschaft

    Bad Oeynhausen, 32545

  • Deutsched Herzzentrum Berlin

    Berlin, 13353

  • Martin Luther University Halle Winttenberg

    Halle, 06112

  • Universitätklinikum Hamburg Eppendorf

    Hamburg, 20246

  • Herzentrum Leipzig GmbH

    Leipzig, 04289

  • University Hospital Regensburg

    Regensburg, 93053

Other trials in Germany

About this study

Official title: ACURATE Neo™ Aortic Bioprosthesis for Implantation Using the ACURATE Neo™ TA Transapical Delivery System in Patients With Severe Aortic Stenosis

The purpose of this investigation is to collect data pertaining to the safety and performance of the ACURATE neo (TM) Aortic Bioprosthesis as implanted with the ACURATE neo (TM) TA Transapical Delivery System. This device is intended for treatment of subjects with severe aortic stenosis (AS) who have high risk for conventional aortic valve replacement (AVR) surgery. The ACURATE neo (TM) Aortic Bioprosthesis is intended for use via minimally-invasive transapical implantation in a well-defined population.

Read the detailed description

This is a single arm, prospective, multicenter non randomised and open trial of the treatment of patients with severe aortic stenosis where conventional aortic valve replacement (AVR) via open heart surgery is considered to be high risk. All patients will be followed up to 5 years after the intervention.

The primary objective is to evaluate the safety and performance of the study device in patients presenting with severe aortic stenosis considered to be high risk for surgery Secondary objective is to evaluate adverse events and study device performance.

Conditions
Aortic Stenosis
Being tested
ACURATE neo™TA Delivery System
Keywords
TAVI, Aortic Stenosis, transcatether Aortic Valve Implantation
Medical subject headings
Aortic Valve Stenosis

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • ACURATE neo™TA Delivery SystemDevice

    ACURATE neo™ Aortic Bioprosthesis and ACURATE neo™TA Transapical Delivery System on patients with severe aortic stenosis where conventional aortic valve replacement (AVR) via open-heart surgery is considered to be high risk

Study groups in NCT02950428
Study groupRoleWhat they receive
ACURATE neo™TA Delivery SystemExperimentalPatients implanted with ACURATE neo™ Aortic Bioprosthesis and ACURATE neo™ TA Transapical Delivery System
Receives: Device: ACURATE neo™TA Delivery System

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. Primary Safety: freedom from all-cause mortality

    freedom from all-cause mortality

    Measured: 6 months post procedure

  2. Primary Device Performance:Procedure success in absence of MACCE

    Procedure success in absence of MACCE

    Measured: 30 days post procedure

Secondary outcomes (7)
  1. Rate of clinical endpoints according to the Valve Academic Research Consortium (VARC 2) guidelines

    VARC 2 guidelines include different safety and efficacy endpoints like mortality, MI, stroke, etc.

    Measured: 30 Days and month 12

  2. Incidence of all cause mortality at 30 Days and 12 Months

    Incidence of all cause mortality at 30 Days and 12 Months

    Measured: 30 days and 12 months

  3. Freedom from MACCE at 30 Days, 6 Months and 12 Months

    Freedom from MACCE at 30 Days, 6 Months and 12 Months

    Measured: 30 Days, 6 Months and 12 Months

  4. Number of patients who have a Procedural success defined by a combination of criteria

    Procedural success defined as ACURATE neo™ at intended location with

    Measured: procedure

  5. Rate of device success

    Rate of device success

    Measured: 7 days/ Discharge, 30 Days, 6 Months and at 12 Months

  6. NYHA Functional Classification improvement

    NYHA Functional Classification improvement

    Measured: 30 Days, 6 Month and at 12 Months

  7. Echocardiographic assessment of valve performance (at 7 Days or Discharge, 30 Days, 6 Months, 12 Months) using a combination of measures

    Echocardiographic assessment of valve performance (at 7 Days or Discharge, 30 Days, 6 Months, 12 Months) using a combination of measures

    Measured: 7 Days or Discharge, 30 Days, 6 Months, 12 Months

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted1 Nov 2016 (estimated)
  2. Study start18 Nov 2015
  3. Primary completion17 Apr 2017
  4. Study completion3 Sep 2021

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Interventional
Phase
Phase N/A
Primary purpose
Treatment
Allocation
Not applicable
Intervention model
Single group
Masking
None (open label)
Enrolment
60 participants (actual)
IDs, dates and publications
ClinicalTrials.gov ID
NCT02950428
Sponsor's protocol ID
2015-01
Status last verified
Feb 2023
First submitted
12 Feb 2016
Last updated
23 Feb 2023
Results posted
No
Data monitoring committee
Yes
FDA-regulated drug
No
FDA-regulated device
No
Individual data sharing
Undecided: The data and study protocol for this clinical trial may be made available to other researchers in accordance with the Boston Scientific Data Sharing Policy (http://www.bostonscientific.com/en-US/data-sharing-requests.html).

Publications

  • Conradi L, Hilker M, Kempfert J, Borgermann J, Treede H, Holzhey DM, Schrofel H, Kim WK, Schaefer U, Walther T. Prospective multicentre evaluation of a novel, low-profile transapical delivery system for self-expandable transcatheter aortic valve implantation: 6-month outcomes. Eur J Cardiothorac Surg. 2018 Oct 1;54(4):762-767. doi: 10.1093/ejcts/ezy097.

    PubMed 29554265

Questions about this trial

What is this clinical trial studying?

A study testing ACURATE neo™TA Delivery System in people with Aortic Stenosis, run by Symetis SA at 7 sites in Germany.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 14 inclusion and 31 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: finished, as of the sponsor's last update on 23 Feb 2023. Status can change between updates, so confirm with the study contact before making plans.

Where is the study taking place?

The record lists 7 sites in Germany. Whether a site is taking part right now should be confirmed with that site. See every site.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.

How can a doctor refer a patient or contact the research team?

The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

Primary Safety: freedom from all-cause mortality (time frame: 6 months post procedure). The study lists 2 primary outcomes in all. It is what the study was designed to measure, not a finding.

Where can I read the original study information?

On the ClinicalTrials.gov record for NCT02950428, which also lists 1 linked publication.

Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 23 Feb 2023.

Free account

Log in to keep searching

You’ve used your 3 free searches. AzTrials is free: log in or create a free account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in