High Frequency Jet Ventilation in AF Ablation

A study testing High frequency jet ventilation and Conventional ventilation in people with Atrial Fibrillation, run by Oxford University Hospitals NHS Trust at 1 site in United Kingdom.

Completed

Finished. The study has ended and is not enrolling. Results may be posted on the official record.

Official record
Search all trials

Trial summary

Atrial fibrillation (AF) is a cardiac condition that results in patients experiencing an irregular heart beat resulting in symptoms including palpitations and breathlessness. It is known that in most cases, AF is caused by abnormal electrical activity from the top of the left side of the heart (left atrium) which… Read more about this study

Who is it for?
Ages 18 to 85 years
Conditions the study is for
Atrial Fibrillation
What is being tested?
High frequency jet ventilation and Conventional ventilation
Type of treatment
Medical device
Could I receive a placebo?
No, everyone receives an active treatment
How many people
30 participants
Where
1 siteUnited Kingdom
Study dates
7 Apr 2017to 31 May 2019
Phase
Interventional
Are there results?
None posted in the registry

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 18 to 85 years
  • All sexes
  • No healthy volunteers
  • Adult, Older adult

Who may be able to join

  • Participant is willing and able to give informed consent for participation in the study.
  • Male or Female, aged 18 years or above.
  • Indication for left atrial catheter ablation for persistent atrial fibrillation
  • Patients may be enrolled in other atrial fibrillation trials at Oxford University Hospitals Foundation Trust (unless directly related to ventilation or ablation strategy)

Who cannot join

  • Age<18 and >85
  • Left ventricular ejection fraction <35%
  • Severe lung disease - chronic obstructive pulmonary disease or asthma requiring home oxygen therapy or >3 admissions in preceding 12 months
  • Previously failed high frequency jet ventilation due to hypercapnia
  • Previous catheter ablation for atrial fibrillation

Trial locations and contacts

1 site in 1 country.

United Kingdom1 site
  • John Radcliffe Hospital

    Oxford, Oxfordshire, OX3 9DU

Other trials in United Kingdom

About this study

Atrial fibrillation (AF) is a cardiac condition that results in patients experiencing an irregular heart beat resulting in symptoms including palpitations and breathlessness. It is known that in most cases, AF is caused by abnormal electrical activity from the top of the left side of the heart (left atrium) which overrides the heart natural pacemaker in the right atrium. Treatment options include tablets which suppress this abnormal electrical activity, but in some patients these are not sufficient and a procedure is carried out where the areas of abnormal electrical activity are disconnected or 'ablated' to prevent AF from occurring. This treatment is well established and performed worldwide, often under general anaesthetic (GA). The heart and lungs sit close together in the chest, and when the lungs are inflated and deflated during the procedure, the heart also moves. This movement is then transmitted to the special wires or 'catheters' that are placed inside the heart to deliver the ablation treatment. Instability during the treatment can result in ineffective areas of ablation which may later contribute to reduced success of the procedure. Previous research has shown that by reducing the movement of the heart under anaesthesia using alternative techniques can improve catheter stability and improve procedural results. Once such technique is called high frequency jet ventilation (HFJV) which allows the lungs to filled with air using fast and shallow breaths resulting in normal blood oxygen levels with little movement in the heart. This technique has been shown to be safe and effective for this procedure but a direct comparison with conventional ventilation has not been done. The investigators wish to test this and determine if using HFJV improves outcomes during the procedure (i.e. can investigators do the treatment faster and more effectively) and if this translates to better outcomes long term.

Read the detailed description

Catheter ablation for the treatment of the symptoms of fibrillation is now a well-established technique. The technique is complex and commonly undertaken under general anaesthesia. Catheters are introduced into the circulation from the veins at the top of the leg and advanced to the right side of the heart. Using x-ray and ultrasound guidance, the catheters are passed to the left atrium by puncturing the muscle that divides left and right atria (septum). A model of the left atrium is created and this used to guide the movement of an ablation catheter across the tissue and create ablation lesions that lead to electrical isolation of target sites.

Under general anaesthesia, the lungs are inflated and deflated via the ventilator circuit. The expansion of the lungs results in movement of the heart with each respiratory cycle. This leads to catheter instability as the tissue is moved towards and away from a catheter positioned in the left atrium. This movement is particularly marked at the back of the left atrium. This instability can lead to real time variation in the delivery of energy which can result in ineffective lesions. These will then translate acutely to incomplete isolation and the need for further ablation (thereby increasing procedure time) and later into reconnection of tissue which can result in repeated procedures being needed to achieve an effective outcome. Each procedure carries risk of minor and major complications therefore measures to improve first time success are critical.

Current research supports the use of steerable catheter sheaths (tubes through which the catheters travel to the atria) and 3 dimensional mapping in improving ablation parameters. Data also exists demonstrating significant variation in catheter contact despite these measures. In order to improve catheter stability further, changes to the mode of ventilation has been studied. Small studies have shown that by stopping cardiac movement altogether by transiently stopping ventilation (apnoea) catheter stability is improved and ablation is more effective. However, intermittent apnoea is not an effective method of ventilation in long cases. An alternative is high frequency jet ventilation. This is where the lungs are ventilated with low volume, high speed and high pressure breaths. This technique is well established and has safety data in upper airway surgery and liver radiology procedures where movement of airways and diaphragm needs to be minimized. In view of this, this technique has been studied in AF ablation and has been shown to improve catheter stability and energy delivery with no increase in complications related to the mode of ventilation. However, existing studies have focused mainly in paroxysmal AF patients (where less ablation is needed) and conducted in a non randomized trial design.

The investigators wish to research the use of HFJV in patients undergoing ablation for persistent AF in a prospective and randomised trial to answer the primary and secondary questions shown below.

Being tested
High frequency jet ventilation, Conventional ventilation
Keywords
atrial fibrillation, catheter ablation, general anaesthesia
Medical subject headings
Atrial Fibrillation

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • High frequency jet ventilationDevice

    General anaesthesia and ventilation with the Acutronic Monsoon III Jet ventilator system

  • Conventional ventilationDevice

    General anaesthesia and ventilation with a conventional Phillips intermittent positive pressure ventilator system

Study groups in NCT02968147
Study groupRoleWhat they receive
Conventional ventilationExperimentalCatheter ablation for persistent atrial fibrillation with general anesthesia and conventional ventilation
Receives: Device: Conventional ventilation
Jet ventilationExperimentalCatheter ablation for persistent atrial fibrillation with general anesthesia and high frequency jet ventilation
Receives: Device: High frequency jet ventilation

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. Number of patients with improved catheter contact force during AF ablation under high frequency jet ventilation

    Data will be extracted from the St Jude Medical Velocity/Tacticath system to determine average force (grams/sec) for each applied lesion.

    Measured: 12 months

Secondary outcomes (3)
  1. Number of patients with improved lesion power delivery during AF ablation under high frequency jet ventilation

    Data will be extracted from the St Jude Medical Velocity/Tacticath system to determine power delivery (force time integral) for each applied lesion.

    Measured: 12 months

  2. Number of patients with improved lesion creation during AF ablation under high frequency jet ventilation

    Data will be extracted from the St Jude Medical Velocity/Tacticath system to determine power delivery (lesion size index) for each applied lesion.

    Measured: 12 months

  3. Number of patients with improved catheter stability during AF ablation under high frequency jet ventilation

    Data will be extracted from the St Jude Medical Velocity/Tacticath system to determine catheter movement (mm movement during ablation) for each applied lesion.

    Measured: 12 months

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted18 Nov 2016 (estimated)
  2. Study start7 Apr 2017
  3. Primary completion7 Nov 2017
  4. Study completion31 May 2019

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Interventional
Phase
Phase N/A
Primary purpose
Treatment
Allocation
Randomised
Intervention model
Parallel groups
Masking
None (open label)
Enrolment
30 participants (actual)
IDs, dates and publications
ClinicalTrials.gov ID
NCT02968147
Sponsor's protocol ID
PID11559
Status last verified
Nov 2016
First submitted
1 Feb 2016
Last updated
1 Jun 2021
Results posted
No
Data monitoring committee
No
FDA-regulated drug
No
FDA-regulated device
No
Individual data sharing
No

Questions about this trial

What is this clinical trial studying?

A study testing High frequency jet ventilation and Conventional ventilation in people with Atrial Fibrillation, run by Oxford University Hospitals NHS Trust at 1 site in United Kingdom.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 4 inclusion and 5 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: finished, as of the sponsor's last update on 1 Jun 2021. Status can change between updates, so confirm with the study contact before making plans.

Where is the study taking place?

The record lists 1 site in United Kingdom. Whether a site is taking part right now should be confirmed with that site. See every site.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.

How can a doctor refer a patient or contact the research team?

The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

Number of patients with improved catheter contact force during AF ablation under high frequency jet ventilation (time frame: 12 months). It is what the study was designed to measure, not a finding.

Where can I read the original study information?
Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 1 Jun 2021.

Free account

Keep searching with a free account

You’ve used your 3 free searches for this session. Log in or create a free AzTrials account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in
High Frequency Jet Ventilation in AF Ablation | AzTrials