The purpose of this study is to compare the diagnostic accuracy and complication rate between low-dose computed tomography-guided and standard-dose computed tomography-guided lung biopsy. Read more about this study

Who is it for?
Ages 18 to 90 years
What is being tested?
Low-dose protocol computed tomography and Standard-dose protocol computed tomography
Type of treatment
Surgery or procedure
Could I receive a placebo?
No, everyone receives an active treatment
How many people
280 participants
Where
1 siteChina
Study dates
30 Nov 2016to 31 May 2019
Phase
Interventional
Are there results?
None posted in the registry

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 18 to 90 years
  • All sexes
  • No healthy volunteers
  • Adult, Older adult

Who may be able to join

  • Non-diagnostic lung lesions; Solid lung lesions; Lesion size ≥ 5mm.

Who cannot join

  • The lesion which has been punctured previously; Severe dysfunction in heart, lung and coagulation function.

Trial locations and contacts

1 site in 1 country.

China1 site
  • Xuzhou Central Hospital

    Xuzhou, Jiangsu, 221009

Other trials in China

About this study

The purpose of this study is to compare the diagnostic accuracy and complication rate between low-dose computed tomography-guided and standard-dose computed tomography-guided lung biopsy.

Read the detailed description

With the comprehensive usage of computed tomography examination, patients are more and more aware of the radiation dose of computed tomography. Concerns over the potential for radiation induced malignancies have increasingly been published in the scientific literature and reported in the popular press. The risk is highest for younger patients, who have more radiation-sensitive tissues and longer life expectancies than adults. Recently, the United States Food and Drug Administration announced an initiative to reduce unnecessary radiation exposure from medical imaging. At present, low-dose computed tomography protocol is widely used for the diagnosis of cardiovascular and cerebrovascular diseases.

Computed tomography-guided lung biopsy is widely used for diagnosis of lung nodules and masses. However, it requires repeating scanning to guide the needles, which inevitably increases the radiation dose. Therefore, low-dose protocol was also used in the computed tomography-guided lung biopsy procedure.

The purpose of this study is to compare the diagnostic accuracy and complication rate between low-dose computed tomography-guided and standard-dose computed tomography-guided lung biopsy.

Being tested
Low-dose protocol computed tomography, Standard-dose protocol computed tomography
Medical subject headings
Adenocarcinoma of Lung, Plasma Cell Granuloma, Pulmonary

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • Low-dose protocol computed tomographyRadiation

    Radiation dose under the low-dose protocol computed tomography (120 kilovolt, 15 milliampere seconds)

  • Standard-dose protocol computed tomographyRadiation

    Radiation dose under the standard-dose protocol computed tomography (120 kilovolt, 150 milliampere seconds)

Study groups in NCT02971176
Study groupRoleWhat they receive
Low-dose protocolExperimentalPatients undergo low-dose protocol computed tomography-guided lung biopsy on day 1.
Receives: Radiation: Low-dose protocol computed tomography
Standard-dose protocolActive comparatorPatients undergo standard-dose protocol computed tomography-guided lung biopsy on day 1.
Receives: Radiation: Standard-dose protocol computed tomography

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. Diagnostic accuracy

    Diagnostic accuracy is defined as the biopsy diagnosis matches with the final diagnosis. The final diagnosis is made according to the surgical or follow-up findings.

    Measured: From the date of randomization until the date of first documented final diagnosis, assessed up to 24 months

Secondary outcomes (1)
  1. Complication

    Biopsy-related complications mainly include pneumothorax and hemoptysis. Complications is evaluated by computed tomography scan and clinical symptoms.

    Measured: From the date of randomization until the date of first documented biopsy-related complication, assessed up to 1 day.

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted22 Nov 2016 (estimated)
  2. Study start30 Nov 2016
  3. Primary completion31 May 2019
  4. Study completion31 May 2019

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Interventional
Phase
Phase N/A
Primary purpose
Diagnosis
Allocation
Randomised
Intervention model
Parallel groups
Masking
Single blind
Who is masked
Participant
Enrolment
280 participants (actual)
IDs, dates and publications
ClinicalTrials.gov ID
NCT02971176
Sponsor's protocol ID
20161115-010
Status last verified
Jun 2019
First submitted
17 Nov 2016
Last updated
4 Jun 2019
Results posted
No
Data monitoring committee
Yes
Individual data sharing
No: There is not a plan to make individual participant data available.

Publications

  • Fazel R, Krumholz HM, Wang Y, Ross JS, Chen J, Ting HH, Shah ND, Nasir K, Einstein AJ, Nallamothu BK. Exposure to low-dose ionizing radiation from medical imaging procedures. N Engl J Med. 2009 Aug 27;361(9):849-57. doi: 10.1056/NEJMoa0901249.

    PubMed 19710483
  • Brenner DJ, Hall EJ. Computed tomography--an increasing source of radiation exposure. N Engl J Med. 2007 Nov 29;357(22):2277-84. doi: 10.1056/NEJMra072149. No abstract available.

    PubMed 18046031
  • Jaffe TA, Yoshizumi TT, Toncheva G, Anderson-Evans C, Lowry C, Miller CM, Nelson RC, Ravin CE. Radiation dose for body CT protocols: variability of scanners at one institution. AJR Am J Roentgenol. 2009 Oct;193(4):1141-7. doi: 10.2214/AJR.09.2330.

    PubMed 19770340
  • Gnannt R, Winklehner A, Goetti R, Schmidt B, Kollias S, Alkadhi H. Low kilovoltage CT of the neck with 70 kVp: comparison with a standard protocol. AJNR Am J Neuroradiol. 2012 Jun;33(6):1014-9. doi: 10.3174/ajnr.A2910. Epub 2012 Feb 2.

    PubMed 22300930
  • Zhang LJ, Qi L, De Cecco CN, Zhou CS, Spearman JV, Schoepf UJ, Lu GM. High-pitch coronary CT angiography at 70 kVp with low contrast medium volume: comparison of 80 and 100 kVp high-pitch protocols. Medicine (Baltimore). 2014 Nov;93(22):e92. doi: 10.1097/MD.0000000000000092.

    PubMed 25396334
  • Neefjes LA, Dharampal AS, Rossi A, Nieman K, Weustink AC, Dijkshoorn ML, Ten Kate GJ, Dedic A, Papadopoulou SL, van Straten M, Cademartiri F, Krestin GP, de Feyter PJ, Mollet NR. Image quality and radiation exposure using different low-dose scan protocols in dual-source CT coronary angiography: randomized study. Radiology. 2011 Dec;261(3):779-86. doi: 10.1148/radiol.11110606. Epub 2011 Oct 3.

    PubMed 21969666
  • Chen GZ, Zhang LJ, Schoepf UJ, Wichmann JL, Milliken CM, Zhou CS, Qi L, Luo S, Lu GM. Radiation dose and image quality of 70 kVp cerebral CT angiography with optimized sinogram-affirmed iterative reconstruction: comparison with 120 kVp cerebral CT angiography. Eur Radiol. 2015 May;25(5):1453-63. doi: 10.1007/s00330-014-3533-y. Epub 2015 Jan 31.

    PubMed 25636415
  • Nour-Eldin NE, Alsubhi M, Emam A, Lehnert T, Beeres M, Jacobi V, Gruber-Rouh T, Scholtz JE, Vogl TJ, Naguib NN. Pneumothorax Complicating Coaxial and Non-coaxial CT-Guided Lung Biopsy: Comparative Analysis of Determining Risk Factors and Management of Pneumothorax in a Retrospective Review of 650 Patients. Cardiovasc Intervent Radiol. 2016 Feb;39(2):261-70. doi: 10.1007/s00270-015-1167-3. Epub 2015 Jul 7.

    PubMed 26148648
  • Nour-Eldin NE, Alsubhi M, Naguib NN, Lehnert T, Emam A, Beeres M, Bodelle B, Koitka K, Vogl TJ, Jacobi V. Risk factor analysis of pulmonary hemorrhage complicating CT-guided lung biopsy in coaxial and non-coaxial core biopsy techniques in 650 patients. Eur J Radiol. 2014 Oct;83(10):1945-52. doi: 10.1016/j.ejrad.2014.06.023. Epub 2014 Jul 5.

    PubMed 25063212
  • Kallianos KG, Elicker BM, Henry TS, Ordovas KG, Nguyen J, Naeger DM. Instituting a Low-dose CT-guided Lung Biopsy Protocol. Acad Radiol. 2016 Sep;23(9):1130-6. doi: 10.1016/j.acra.2016.05.013. Epub 2016 Jun 14.

    PubMed 27317393
  • Adiga S, Athreya S. Safety, efficacy, and feasibility of an ultra-low dose radiation protocol for CT-guided percutaneous needle biopsy of pulmonary lesions: initial experience. Clin Radiol. 2014 Jul;69(7):709-14. doi: 10.1016/j.crad.2014.02.006. Epub 2014 Apr 4.

    PubMed 24709093
  • Smith JC, Jin DH, Watkins GE, Miller TR, Karst JG, Oyoyo UE. Ultra-low-dose protocol for CT-guided lung biopsies. J Vasc Interv Radiol. 2011 Apr;22(4):431-6. doi: 10.1016/j.jvir.2011.01.431.

    PubMed 21463754
  • Meng XX, Kuai XP, Dong WH, Jia NY, Liu SY, Xiao XS. Comparison of lung lesion biopsies between low-dose CT-guided and conventional CT-guided techniques. Acta Radiol. 2013 Oct;54(8):909-15. doi: 10.1177/0284185113485937. Epub 2013 Jul 1.

    PubMed 23817682
  • Fu YF, Li GC, Xu QS, Shi YB, Wang C, Wang T. Computed tomography-guided lung biopsy: a randomized controlled trial of low-dose versus standard-dose protocol. Eur Radiol. 2020 Mar;30(3):1584-1592. doi: 10.1007/s00330-019-06464-6. Epub 2019 Nov 27.

    PubMed 31776740

Questions about this trial

What is this clinical trial studying?

A study testing Low-dose protocol computed tomography and Standard-dose protocol computed tomography in people with Lung Cancer, Adenocarcinoma and Lung Inflammatory Pseudotumor, run by Xuzhou Central Hospital at 1 site in China.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 1 inclusion and 1 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: finished, as of the sponsor's last update on 4 Jun 2019. Status can change between updates, so confirm with the study contact before making plans.

Where is the study taking place?

The record lists 1 site in China. Whether a site is taking part right now should be confirmed with that site. See every site.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.

How can a doctor refer a patient or contact the research team?

The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

Diagnostic accuracy (time frame: From the date of randomization until the date of first documented final diagnosis, assessed up to 24 months). It is what the study was designed to measure, not a finding.

Where can I read the original study information?

On the ClinicalTrials.gov record for NCT02971176, which also lists 14 linked publications.

Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 4 Jun 2019.

Free account

Keep searching with a free account

You’ve used your 3 free searches for this session. Log in or create a free AzTrials account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in