AzTrials
AzTrials

Mechanical VentilationNCT02976844

Effect of Positive End-expiratory Pressure on Optimal Balloon Volume During Esophageal Pressure Monitoring

An observational study of Mechanical Ventilation, run by Capital Medical University at 1 site in China.

Completed

Finished. The study has ended and is not enrolling. Results may be posted on the official record.

Official record
Search all trials

Trial summary

Esophageal pressure (PES), which has been used as a surrogate for pleural pressure. The volume of esophageal balloon can influence the accuracy of monitoring esophageal pressure. The optimal balloon volume is directly dependent on surrounding pressure. Read more about this study

Who is it for?
Ages 18 to 80 years
Conditions the study is for
Mechanical Ventilation
What is being tested?
Positive end-expiratory Pressure
Type of treatment
Surgery or procedure
How many people
12 participants
Where
1 siteChina
Study dates
Aug 2016to Jan 2017
Phase
Observational
Are there results?
None posted in the registry

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 18 to 80 years
  • All sexes
  • No healthy volunteers
  • Adult, Older adult

Study population: postoperative patients receiving mechanical ventilation

Who may be able to join

  • postoperative patients with delayed emergence from general anesthesia admitted to the ICU for mechanical ventilation.

Who cannot join

  • age under 18 years;
  • diagnosed or suspected esophageal varices;
  • history of chronic obstructive pulmonary diseases or asthma;
  • history of esophageal, gastric or lung surgery;
  • evidence of active air leak from the lung, including bronchopleural fistula, pneumothorax, pneumomediastinum, or an existing chest tube;
  • evidence of severe coagulopathy.

Trial locations and contacts

1 site in 1 country.

China1 site
  • ICU, Beijing Tiantan Hospital, Capital Medical University

    Beijing, Beijing Municipality, 100050

Other trials in China

About this study

Official title: Effect of Positive End-expiratory Pressure on Optimal Balloon Volume During Esophageal Pressure Monitoring in Mechanical Ventilated Patients: A Clinical Feasibility Study

Esophageal pressure (PES), which has been used as a surrogate for pleural pressure. The volume of esophageal balloon can influence the accuracy of monitoring esophageal pressure. The optimal balloon volume is directly dependent on surrounding pressure. In the present study,the investigators will observe the optimal volume of esophageal balloon during the different PEEP in bench and clinical study.

Read the detailed description

The esophageal pressure (Pes) is used as a surrogate for pleural pressure to obtain transpulmonary pressure. Catheter with air balloon is the most commonly used method to measure the Pes. The optimal injected volume of the balloon is the key factor in accurate measurement of Pes. The recoil pressure of the balloon turns up while the balloon is over-filled, resulting in over-estimation of the PES; on the other hand, an under-filled balloon also cannot properly transmit the surrounding pressure of balloon. However, the researchers showed the optimal balloon volumes is related to the surrounding pressure and even is not correspond with manufacturer's recommendations. Theoretically, when balloon transmural pressure(PTM) is zero, representing the balloon in a condition with equivalent pressure inside and outside of the balloon, it was defined as optimal volume. However, in clinical settings, it is difficult to determine the balloon PTM, and therefore the optimal volume cannot be obtained, because the surrounding pressure of the balloon cannot be conveniently measured.

In the present study, the investigators will develop a simple method to obtain the optimal balloon volume and observe the effect of positive end-expiratory pressure on optimal balloon volume during esophageal pressure monitoring. The investigators want to validate the accuracy of method in the bench study and clinical feasibility in mechanical ventilated patients.

Being tested
Positive end-expiratory Pressure
Keywords
optimal balloon volume, positive end-expiratory pressure

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • Positive end-expiratory PressureProcedure or surgery

    Positive end-expiratory pressure will be used during mechanical ventilation.

Study groups in NCT02976844
Study groupRoleWhat they receive
Low PEEP groupThe positive end-expiratory pressure was less than 10cmH2O
Receives: Procedure: Positive end-expiratory Pressure
High PEEP groupThe positive end-expiratory pressure was higher or equal to 10cmH2O.
Receives: Procedure: Positive end-expiratory Pressure

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. The optimal balloon volume at different PEEP

    The 3 minutes after esophageal balloon volume changing, the investigators will record the end-expiratory and end-inspiratory esophageal pressure. The pressure and volume curve will be drawn to determine the optimal volume.

    Measured: within 3 minutes after esophageal balloon volume changing

Secondary outcomes (1)
  1. The transpulmonary pressure

    Measured: within 3 minutes after esophageal balloon volume changing

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted29 Nov 2016 (estimated)
  2. Study startAug 2016
  3. Primary completionJan 2017
  4. Study completionJan 2017

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Observational
Observational model
Case crossover
Time perspective
Prospective
Enrolment
12 participants (actual)
IDs, dates and publications
ClinicalTrials.gov ID
NCT02976844
Sponsor's protocol ID
KY-2016-11-22
Status last verified
Jan 2017
First submitted
23 Nov 2016
Last updated
7 Aug 2017
Results posted
No
Data monitoring committee
Yes

Publications

  • Sun XM, Chen GQ, Huang HW, He X, Yang YL, Shi ZH, Xu M, Zhou JX. Use of esophageal balloon pressure-volume curve analysis to determine esophageal wall elastance and calibrate raw esophageal pressure: a bench experiment and clinical study. BMC Anesthesiol. 2018 Feb 14;18(1):21. doi: 10.1186/s12871-018-0488-6.

    PubMed 29444644

Questions about this trial

What is this clinical trial studying?

An observational study of Mechanical Ventilation, run by Capital Medical University at 1 site in China.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 1 inclusion and 6 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: finished, as of the sponsor's last update on 7 Aug 2017. Status can change between updates, so confirm with the study contact before making plans.

Where is the study taking place?

The record lists 1 site in China. Whether a site is taking part right now should be confirmed with that site. See every site.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.

How can a doctor refer a patient or contact the research team?

The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

The optimal balloon volume at different PEEP (time frame: within 3 minutes after esophageal balloon volume changing). It is what the study was designed to measure, not a finding.

Where can I read the original study information?

On the ClinicalTrials.gov record for NCT02976844, which also lists 1 linked publication.

Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 7 Aug 2017.

Free account

Log in to keep searching

You’ve used your 3 free searches. AzTrials is free: log in or create a free account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in