GlaucomaNCT02988752

Comparison Between an Electronic Mobile Device and Optical Coherence Tomography to Determine Cup-to-disc Ratio

A study testing Electronic Mobile Device and Optical Coherence Tomography in people with Glaucoma, run by Clinica Oftamologica Zona Sul at 1 site in Brazil.

Unknown status

Status not confirmed. The sponsor has not verified this record for over two years, so it may be out of date.

Official record
Search all trials

Trial summary

This study was a non-inferiority trial with masked data analysis. Individuals ranging from 18 to 60 years from both genders that met the pre-defined criteria were included. This study was carried out in Recife at Clinica Oftalmologica Zona Sul and at Centro de Informatica-UFPE. Read more about this study

Who is it for?
Ages 18 to 60 yearsHealthy volunteers can take part
Conditions the study is for
Glaucoma
What is being tested?
Electronic Mobile Device and Optical Coherence Tomography
Type of treatment
Medical device
Could I receive a placebo?
No, everyone receives an active treatment
How many people
110 participants
Where
1 siteBrazil
Study dates
Oct 2016to Nov 2017
Phase
Interventional
Are there results?
None posted in the registry

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 18 to 60 years
  • All sexes
  • Healthy volunteers accepted
  • Adult

Who may be able to join

  • Anyone from 18 to 60 Years old without any of the Specified Exclusion Criteria.

Who cannot join

  • Cancer
  • Cataract
  • Eyes transparency loss
  • Best Av < 0.4
  • Eye surgery in the last 12 Months
  • Use of drugs that leads to any kind of Neuropathy

Trial locations and contacts

1 site in 1 country.

Brazil1 site
  • Clinica Oftalmologica Zona Sul

    Recife, Pernambuco, 51110000

Other trials in Brazil

About this study

Official title: Comparison Between an Electronic Mobile Device(DEM) and Optical Coherence Tomography (OCT) to Determine Cup-to-disc Ratio (C/D) Through a Non-inferiority Trial With Masked Data Analysis

This study was a non-inferiority trial with masked data analysis. Individuals ranging from 18 to 60 years from both genders that met the pre-defined criteria were included. This study was carried out in Recife at Clinica Oftalmologica Zona Sul and at Centro de Informatica-UFPE. Using both equipment, 5 vertical cup-to-disc ratio (VCDR) evaluations were performed for each eye of the individuals, under midriatic conditions. Evaluations were done by examiners who did not know previously results obtained from other equipment. Data was collected by the main researcher of this research. This study was approved by the ethics committee before it started and all research members signed the TCLE agreement. The statistical test employed in this study was Pearson Correlation test.

Read the detailed description

Glaucoma is the second major cause of blindness in the world, lagging only behind cataract. However, unlike cataract, blindness caused by glaucoma is irreversible. Early diagnosis of the disease and progression monitoring is thus essential for proper treatment in order to avoid irreversible blindness. The most common screening exam for glaucoma diagnosis and monitoring is the eye fundus evaluation where Cup-to-Disc ratio (CDR) among other parameters are assessed. This kind of evaluation is performed by ophthalmologists based on their visual perception, requiring not only specific training but also some significant amount of time of eye examination.Objective measurement of CDR involves high cost equipment which in turn requires some specific training in order to use them. Currently, the Optical Coherence Tomography is used as the gold standard for CDR measurement. An OCT exam uses a high cost and complex equipment that most of the time is not affordable for low-income people. This study proposes a portable electronic device that captures eye fundus images, analyzes these images, performs CDR calculation and allows storing these images for further analysis. This low cost and portable device was developed to be used in several health services (public or private) and has low energy consumption, easing its mobility. Moreover, using this device is easy, not requiring any significant learning effort from ophthalmologists. In developing countries where screening programs for early diagnosis of glaucomatous neuropathy are adopted, an ever-growing number of researchers are putting a significant amount of effort to develop cost-benefit solutions that can reach low-income people and remote areas.

Objective: This study compared CDR measurements from the portable electronic device (PED) developed by Centro de Informatica da Universidade Federal de Pernambuco to CDR measurements provided by OCT.

Methods:This study was a non-inferiority trial with masked data analysis. Individuals ranging from 18 to 60 years from both genders that met the pre-defined criteria were included. This study was carried out in Recife at Clinica Oftalmologica Zona Sul and at Centro de Informatica-UFPE. Using both equipment, 5 vertical cup-to-disc ratio (VCDR) evaluations were performed for each eye of the individuals, under midriatic conditions. Evaluations were done by examiners who did not know previously results obtained from other equipment. Data was collected by the main researcher of this research. This study was approved by the ethics committee before it started and all research members signed the TCLE agreement. The statistical test employed in this study was Pearson Correlation test.

Conditions
Glaucoma
Being tested
Electronic Mobile Device, Optical Coherence Tomography
Medical subject headings
Glaucoma

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • Electronic Mobile DeviceDevice

    Measure C/D Ratio With An Equipment Attached To A Ophthalmoscope That Will Determine C/D Ratio Without Touching Patient's Eyes. To Perform It We Need Mydriatic Conditions.

  • Optical Coherence TomographyDevice

    Also called OCT

    Measure C/D Ratio With OCT, Considered Gold Standard Equipment

Study groups in NCT02988752
Study groupRoleWhat they receive
Electronic Mobile DeviceExperimentalUse an Electronic Low Cost Mobile Device To Determine C/D Ratio And Compare Results With Gold Standard Optical Coherence Tomography Results. The equipment needs mydriatic conditions and does not touch the patient's eye. The equipment uses a panoptik and a camera to access eye fundus.
Receives: Device: Electronic Mobile Device
Optical Coherence TomographyActive comparatorDevice considered as gold standard to determine c/d ratio. Needs mydriatic conditions.
Receives: Device: Optical Coherence Tomography

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. Objective C/D Ratio measure

    To measure vertical cup to disc ratio in an objective way

    Measured: One Year

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted9 Dec 2016 (estimated)
  2. Study startOct 2016
  3. Primary completionNov 2016
  4. Study completionNov 2017 (estimated)

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Interventional
Phase
Phase N/A
Primary purpose
Diagnosis
Allocation
Non-randomised
Intervention model
Single group
Masking
Single blind
Who is masked
Investigator
Enrolment
110 participants (actual)
IDs, dates and publications
ClinicalTrials.gov ID
NCT02988752
Sponsor's protocol ID
COZ001
Status last verified
Dec 2016
First submitted
2 Jun 2016
Last updated
9 Dec 2016
Results posted
No
Data monitoring committee
No
Individual data sharing
No

Questions about this trial

What is this clinical trial studying?

A study testing Electronic Mobile Device and Optical Coherence Tomography in people with Glaucoma, run by Clinica Oftamologica Zona Sul at 1 site in Brazil.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 1 inclusion and 6 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: status not confirmed, as of the sponsor's last update on 9 Dec 2016. Status can change between updates, so confirm with the study contact before making plans.

Where is the study taking place?

The record lists 1 site in Brazil. Whether a site is taking part right now should be confirmed with that site. See every site.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

Results are not available in the source record.

How can a doctor refer a patient or contact the research team?

The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

Objective C/D Ratio measure (time frame: One Year). It is what the study was designed to measure, not a finding.

Where can I read the original study information?
Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 9 Dec 2016; AzTrials last refreshed its copy on 30 Oct 2026.

Free account

Keep searching with a free account

You’ve used your 3 free searches for this session. Log in or create a free AzTrials account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in