Obesity, MorbidNCT03009877
Preoxygenation With Optiflow™ in Morbidly Obese Patients is Superior to Face Mask
A study testing Optiflow F&P 850™ System, facemask and Rocuronium in people with Obesity, Morbid, run by Montefiore Medical Center.
Trial summary
Optiflow™ may provide an opportunity to prolong apnea time in the morbidly obese patient population. This study will examine whether Optiflow can do this, and compare the pre-oxygenation with Optiflow to the pre-oxygenation achieved with face mask. Read more about this study
- Who is it for?
- Ages 18 years and olderHealthy volunteers can take part
- Conditions the study is for
- Obesity, Morbid
- What is being tested?
- Optiflow F&P 850™ System, facemask and Rocuronium
- Type of treatment
- Injection or infusion, Medical device
- Could I receive a placebo?
- No, everyone receives an active treatment
- How many people
- 0 participants
- Where
- No sites listed yet
- Study dates
- Jul 2018to Dec 2019
- Phase
- Interventional
- Are there results?
- None posted in the registry
Key requirements
Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.
- Ages 18 years and older
- All sexes
- Healthy volunteers accepted
- Adult, Older adult
Who may be able to join
- Adult patients (≥ 18 years old) undergoing elective surgery requiring general anesthesia
- BMI > 40 kg/m2
- American Society of Anesthesiology (ASA) Physical Status II-III
Who cannot join
- Chronic hypoxemia (SpO2 <94% on room air or on home oxygen)
- Acute respiratory failure
- Coronary artery disease and/or congestive heart failure
- Moderate-Severe pulmonary hypertension and/or RV dysfunction
- Full stomach (recently eaten)
- Pregnancy
Show all 10Show fewer
- Chronic pulmonary disease (specifically COPD or interstitial disease, NOT asthma)
- Respiratory tract pathology
- Facial Abnormality
- American Society of Anesthesiology (ASA) Physical Status IV-V
About this study
Official title: Preoxygenation With Optiflow™, a High Flow Nasal Cannula (HFNC), is Superior to Preoxygenation With Facemask in Morbidly Obese Patients Undergoing General Anesthesia
Optiflow™ may provide an opportunity to prolong apnea time in the morbidly obese patient population. This study will examine whether Optiflow can do this, and compare the pre-oxygenation with Optiflow to the pre-oxygenation achieved with face mask.
Read the detailed description
The use of high flow nasal cannula (HFNC) originated in neonatal care, and has become widespread in its application for patients that are high risk for hypoxemia, both in critical care and emergency settings. Therefore, high flow nasal oxygenation continues to be studied in airway management for preoxygenation, as well as maintenance of oxygenation in airway procedures. Optiflow™, a humidified high flow nasal cannula, has already been shown to be useful in preventing desaturation during intubation in ICU patients versus the non-rebreathing mask, in addition to, prolonging safe apnea time in patients with potential difficult airways. Additionally, preoxygenation with HFNC prior to intubation of patients in hypoxemic respiratory failure has also been shown to decrease desaturation during apnea compared to preoxygenation with traditional bag valve mask. The morbidly obese patient presents a separate group of challenges to the anesthesiologist in regards to mask ventilation and intubation. Obesity (along with other factors) has been shown to contribute to difficulty with mask ventilation. Obese patients have altered respiratory physiology, including decreased functional residual capacity, increased oxygen consumption and lower tidal volumes, as compared to the non-obese patient. These factors contribute to obese patients potentially having a shorter apnea time before desaturating during induction of general anesthesia, as compared to the non-obese patient. Weight is inversely correlated with safe apnea time. Optiflow™ may provide an opportunity to prolong apnea time in the morbidly obese patient population. If demonstrated to be efficacious as a method for preoxygenation and prolongation of apneic time, this could provide a safer environment for intubation in this particular patient population.
- Conditions
- Obesity, Morbid
- Medical subject headings
- Obesity, Morbid
What participants receive
What participants receive. In a randomised study each person is assigned to one group by chance.
Optiflow F&P 850™ SystemDevice
Also called High flow nasal cannula
Optiflow™ (Fisher \& Paykel Healthcare Limited, East Tamaki, Auckland-New Zealand) offers the ability to comfortably deliver a complete range of oxygen concentrations and flows to extend the traditional boundaries of oxygen therapy.
This will be placed on the patient immediately upon entering the operating room for 5 minutes, at 50 liters per minute then increased to 70 liters per minute after induction.
facemaskDevice
Also called face mask
We will apply the facemask to the patient immediately upon entering the operating room to pre-oxygenate for five minutes.
RocuroniumDrug
Rocuronium will be administered after the ability to mask ventilate is determined.
PropofolDrug
Propofol infusion 50 micrograms to 150 micrograms will be administered immediately on induction to maintain sedation throughout apneic oxygenation.
FentanylDrug
Fentanyl will be administered at the beginning of induction, 2 micrograms per kilogram.
MidazolamDrug
Also called Versed
midazolam will be given upon induction, 1-2 milligrams at the anesthesiologist's discretion.
C-MAC Premium Video Intubation Platform-KARL STORZDevice
Also called videolaryngoscope and optical fiberoptic bronchoscope
After patient is induced, the 5.5mm flexible intubation video scope (C-MAC Premium Video Intubation Platform-KARL STORZ) will then be introduced into the oropharynx and advanced into the trachea with the assistance of the C-MAC video laryngoscope (3 or 4 blade based on anesthesiologist's discretion).
| Study group | Role | What they receive |
|---|---|---|
| Preoxygenation with face mask | Active comparator | Standard preoxygenation with a mask will be performed for five minutes. Once preoxygenation is complete, patients will be induced with standard induction medications including lidocaine, midazolam, fentanyl and propofol. Once the patient is apneic, one breath will be given via facemask to confirm ventilation and then 0.6 mg/kg of rocuronium will be administered. The 5.5mm flexible intubation scope will be introduced into the oropharynx and advanced into the trachea with the assistance of the C-MAC video laryngoscope. Once the flexible intubation scope is in the trachea, the endotracheal tube (7.0 mm unless otherwise specified) will be advanced. Ventilation will not begin until the primary or secondary endpoints are reached. Receives: Device: facemask; Drug: Rocuronium; Drug: Propofol; Drug: Fentanyl; Drug: Midazolam; Device: C-MAC Premium Video Intubation Platform-KARL STORZ |
| Preoxygenation via hi flow nasal cannula | Experimental | The high flow nasal cannula (Optiflow) will be applied as soon as the patient is in the operating room. The patient will be preoxygenated with high flow nasal cannula at 50 L/min for 5 minutes. After induction, general anesthesia will be maintained with a propofol infusion. One breath will be given via facemask to confirm ventilation and then 0.6 mg/kg of rocuronium will be administered. Upon apnea, the Optiflow™ flow will be increased to 70 L/min and jaw thrust will be performed until the patient is adequately relaxed. The video laryngoscope (C-MAC) will then be introduced into the oropharynx and the flexible intubation scope advanced into the trachea with the assistance of the C-MAC. Once the flexible intubation scope is in the trachea, the endotracheal tube will be advanced. Receives: Device: Optiflow F&P 850™ System; Drug: Rocuronium; Drug: Propofol; Drug: Fentanyl; Drug: Midazolam; Device: C-MAC Premium Video Intubation Platform-KARL STORZ |
What is being measured
The primary outcome is the main question the study is designed to answer.
Time to desaturation
Intraoperatively, apneic time will be record from the time of administration of the muscle relaxant. The time until the first desaturation will be recorded. The maximum time of measurement will be 10 minutes.
Measured: up to 10 minutes
Secondary outcomes (2)
Time until hypercarbia > 65 mmHg
The time until hypercarbia to more than 65 mmHg will be measured from the time of administration of the muscle relaxant. The time until transcutaneous CO2 is > 65 mmHg will be recorded, unless 10 minutes is reached before that level is reached.
Measured: up to 10 minutes
Assess correlation between end tidal CO2 and transcutaneous CO2 monitoring
Assessment of accurate correlation between transcutaneous CO2 monitoring, end tidal CO2, and/or PaCO2 will be performed up to 10 minutes.
Measured: up to 10 minutes
Timeline
From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.
- First posted4 Jan 2017 (estimated)
- Study startJul 2018 (estimated)
- Primary completionMay 2019 (estimated)
- Study completionDec 2019 (estimated)
Why it stopped: withdrawn prior to IRB approval
Resources
- Official record on ClinicalTrials.govThe registry entry this page is built from, with its full change history.
- Publications (22)Papers the sponsor has linked to this study.
- Other trials for Obesity, MorbidStudies of the same condition, open and under way.
- More trials run by Montefiore Medical CenterThe sponsor's other registered studies.
- What the trial phases meanHow a treatment moves from first tests in people to approval.
More details
For doctors and researchers: how the study is designed, who runs it, and its registry IDs.
Study design
- Study type
- Interventional
- Phase
- Phase N/A
- Primary purpose
- Treatment
- Allocation
- Randomised
- Intervention model
- Parallel groups
- Masking
- None (open label)
- Enrolment
- 0 participants (actual)
Sponsor and investigators
- Lead sponsor
- Montefiore Medical Center
- Sponsor type
- University, hospital or other
- Responsible party
- Principal investigator, Tracey Straker, Montefiore Medical Center
- Investigators
- Irene Osborn, MD, Study director, Montefiore Medical Center
IDs, dates and publications
- ClinicalTrials.gov ID
- NCT03009877
- Sponsor's protocol ID
- 2016-7360
- Status last verified
- Mar 2018
- First submitted
- 21 Dec 2016
- Last updated
- 27 Mar 2018
- Results posted
- No
- Data monitoring committee
- No
- FDA-regulated drug
- No
- FDA-regulated device
- Yes
- Individual data sharing
- Yes: This is a collaborative study, so the information will be shared with the researchers in Texas. However, we do not plan to use this information for other studies.
Publications
Locke RG, Wolfson MR, Shaffer TH, Rubenstein SD, Greenspan JS. Inadvertent administration of positive end-distending pressure during nasal cannula flow. Pediatrics. 1993 Jan;91(1):135-8.
PubMed 8416477Frat JP, Thille AW, Mercat A, Girault C, Ragot S, Perbet S, Prat G, Boulain T, Morawiec E, Cottereau A, Devaquet J, Nseir S, Razazi K, Mira JP, Argaud L, Chakarian JC, Ricard JD, Wittebole X, Chevalier S, Herbland A, Fartoukh M, Constantin JM, Tonnelier JM, Pierrot M, Mathonnet A, Beduneau G, Deletage-Metreau C, Richard JC, Brochard L, Robert R; FLORALI Study Group; REVA Network. High-flow oxygen through nasal cannula in acute hypoxemic respiratory failure. N Engl J Med. 2015 Jun 4;372(23):2185-96. doi: 10.1056/NEJMoa1503326. Epub 2015 May 17.
PubMed 25981908Hayes-Bradley C, Lewis A, Burns B, Miller M. Efficacy of Nasal Cannula Oxygen as a Preoxygenation Adjunct in Emergency Airway Management. Ann Emerg Med. 2016 Aug;68(2):174-80. doi: 10.1016/j.annemergmed.2015.11.012. Epub 2015 Dec 31.
PubMed 26747218Badiger S, John M, Fearnley RA, Ahmad I. Optimizing oxygenation and intubation conditions during awake fibre-optic intubation using a high-flow nasal oxygen-delivery system. Br J Anaesth. 2015 Oct;115(4):629-32. doi: 10.1093/bja/aev262. Epub 2015 Aug 7.
PubMed 26253608Simon M, Braune S, Frings D, Wiontzek AK, Klose H, Kluge S. High-flow nasal cannula oxygen versus non-invasive ventilation in patients with acute hypoxaemic respiratory failure undergoing flexible bronchoscopy--a prospective randomised trial. Crit Care. 2014 Dec 22;18(6):712. doi: 10.1186/s13054-014-0712-9.
PubMed 25529351Miyagi K, Haranaga S, Higa F, Tateyama M, Fujita J. Implementation of bronchoalveolar lavage using a high-flow nasal cannula in five cases of acute respiratory failure. Respir Investig. 2014 Sep;52(5):310-4. doi: 10.1016/j.resinv.2014.06.006. Epub 2014 Jul 25.
PubMed 25169847Gottschalk A, Mirza N, Weinstein GS, Edwards MW. Capnography during jet ventilation for laryngoscopy. Anesth Analg. 1997 Jul;85(1):155-9. doi: 10.1097/00000539-199707000-00028.
PubMed 9212140Nishimura M. High-flow nasal cannula oxygen therapy in adults. J Intensive Care. 2015 Mar 31;3(1):15. doi: 10.1186/s40560-015-0084-5. eCollection 2015.
PubMed 25866645Patel A, Nouraei SA. Transnasal Humidified Rapid-Insufflation Ventilatory Exchange (THRIVE): a physiological method of increasing apnoea time in patients with difficult airways. Anaesthesia. 2015 Mar;70(3):323-9. doi: 10.1111/anae.12923. Epub 2014 Nov 10.
PubMed 25388828Maggiore SM, Idone FA, Vaschetto R, Festa R, Cataldo A, Antonicelli F, Montini L, De Gaetano A, Navalesi P, Antonelli M. Nasal high-flow versus Venturi mask oxygen therapy after extubation. Effects on oxygenation, comfort, and clinical outcome. Am J Respir Crit Care Med. 2014 Aug 1;190(3):282-8. doi: 10.1164/rccm.201402-0364OC.
PubMed 25003980Aceto P, Perilli V, Modesti C, Ciocchetti P, Vitale F, Sollazzi L. Airway management in obese patients. Surg Obes Relat Dis. 2013 Sep-Oct;9(5):809-15. doi: 10.1016/j.soard.2013.04.013. Epub 2013 May 6.
PubMed 23810609Murphy C, Wong DT. Airway management and oxygenation in obese patients. Can J Anaesth. 2013 Sep;60(9):929-45. doi: 10.1007/s12630-013-9991-x. Epub 2013 Jul 9.
PubMed 23836064Sinha A, Jayaraman L, Punhani D. ProSeal LMA increases safe apnea period in morbidly obese patients undergoing surgery under general anesthesia. Obes Surg. 2013 Apr;23(4):580-4. doi: 10.1007/s11695-012-0833-7.
PubMed 23361469Jense HG, Dubin SA, Silverstein PI, O'Leary-Escolas U. Effect of obesity on safe duration of apnea in anesthetized humans. Anesth Analg. 1991 Jan;72(1):89-93. doi: 10.1213/00000539-199101000-00016.
PubMed 1984382Gambee AM, Hertzka RE, Fisher DM. Preoxygenation techniques: comparison of three minutes and four breaths. Anesth Analg. 1987 May;66(5):468-70. No abstract available.
PubMed 3578856
Study at a glance
From the registry record, last updated by the sponsor on 27 Mar 2018. Recruitment status is as the sponsor reported it: confirm with the study team.
- Official title
- Preoxygenation With Optiflow™, a High Flow Nasal Cannula (HFNC), is Superior to Preoxygenation With Facemask in Morbidly Obese Patients Undergoing General Anesthesia
- ClinicalTrials.gov ID
- NCT03009877
- Acronym / sponsor ID
- 2016-7360
- Conditions
- Obesity, Morbid
- Study type
- Interventional
- Recruitment status
- WithdrawnReason stopped: withdrawn prior to IRB approval
- Enrolment
- 0 participants (actual)
- Lead sponsor
- Montefiore Medical CenterUniversity, hospital or other
- Collaborators
- The University of Texas Health Science Center, Houston, M.D. Anderson Cancer Center
- Study start
- Jul 2018 (estimated)
- Primary completion
- May 2019 (estimated)
- Study completion
- Dec 2019 (estimated)
- First posted
- 4 Jan 2017 (estimated)
- Results
- Not posted in the source record
Clinical summary
The research question as the sponsor registered it. This describes what the study plans to test, not what it found.
Optiflow™ may provide an opportunity to prolong apnea time in the morbidly obese patient population. This study will examine whether Optiflow can do this, and compare the pre-oxygenation with Optiflow to the pre-oxygenation achieved with face mask.
Detailed description
The use of high flow nasal cannula (HFNC) originated in neonatal care, and has become widespread in its application for patients that are high risk for hypoxemia, both in critical care and emergency settings. Therefore, high flow nasal oxygenation continues to be studied in airway management for preoxygenation, as well as maintenance of oxygenation in airway procedures. Optiflow™, a humidified high flow nasal cannula, has already been shown to be useful in preventing desaturation during intubation in ICU patients versus the non-rebreathing mask, in addition to, prolonging safe apnea time in patients with potential difficult airways. Additionally, preoxygenation with HFNC prior to intubation of patients in hypoxemic respiratory failure has also been shown to decrease desaturation during apnea compared to preoxygenation with traditional bag valve mask. The morbidly obese patient presents a separate group of challenges to the anesthesiologist in regards to mask ventilation and intubation. Obesity (along with other factors) has been shown to contribute to difficulty with mask ventilation. Obese patients have altered respiratory physiology, including decreased functional residual capacity, increased oxygen consumption and lower tidal volumes, as compared to the non-obese patient. These factors contribute to obese patients potentially having a shorter apnea time before desaturating during induction of general anesthesia, as compared to the non-obese patient. Weight is inversely correlated with safe apnea time. Optiflow™ may provide an opportunity to prolong apnea time in the morbidly obese patient population. If demonstrated to be efficacious as a method for preoxygenation and prolongation of apneic time, this could provide a safer environment for intubation in this particular patient population.
Study design
- Primary purpose
- Treatment
- Allocation
- Randomised
- Intervention model
- Parallel groups
- Masking
- None (open label)
- Number of arms
- 2
| Arm | Type | Receives |
|---|---|---|
| Preoxygenation with face mask | Active comparator | Device: facemask, Drug: Rocuronium, Drug: Propofol, Drug: Fentanyl, Drug: Midazolam, Device: C-MAC Premium Video Intubation Platform-KARL STORZStandard preoxygenation with a mask will be performed for five minutes. Once preoxygenation is complete, patients will be induced with standard induction medications including lidocaine, midazolam, fentanyl and propofol. Once the patient is apneic, one breath will be given via facemask to confirm ventilation and then 0.6 mg/kg of rocuronium will be administered. The 5.5mm flexible intubation scope will be introduced into the oropharynx and advanced into the trachea with the assistance of the C-MAC video laryngoscope. Once the flexible intubation scope is in the trachea, the endotracheal tube (7.0 mm unless otherwise specified) will be advanced. Ventilation will not begin until the primary or secondary endpoints are reached. |
| Preoxygenation via hi flow nasal cannula | Experimental | Device: Optiflow F&P 850™ System, Drug: Rocuronium, Drug: Propofol, Drug: Fentanyl, Drug: Midazolam, Device: C-MAC Premium Video Intubation Platform-KARL STORZThe high flow nasal cannula (Optiflow) will be applied as soon as the patient is in the operating room. The patient will be preoxygenated with high flow nasal cannula at 50 L/min for 5 minutes. After induction, general anesthesia will be maintained with a propofol infusion. One breath will be given via facemask to confirm ventilation and then 0.6 mg/kg of rocuronium will be administered. Upon apnea, the Optiflow™ flow will be increased to 70 L/min and jaw thrust will be performed until the patient is adequately relaxed. The video laryngoscope (C-MAC) will then be introduced into the oropharynx and the flexible intubation scope advanced into the trachea with the assistance of the C-MAC. Once the flexible intubation scope is in the trachea, the endotracheal tube will be advanced. |
Who may qualify
- Ages
- 18 years and older
- Sex
- All
- Healthy volunteers
- Accepted
- Age groups
- Adult, Older adult
Key inclusion criteria (3 listed)
- Adult patients (≥ 18 years old) undergoing elective surgery requiring general anesthesia
- BMI > 40 kg/m2
- American Society of Anesthesiology (ASA) Physical Status II-III
Key exclusion criteria (10 listed)
- Chronic hypoxemia (SpO2 <94% on room air or on home oxygen)
- Acute respiratory failure
- Coronary artery disease and/or congestive heart failure
- Moderate-Severe pulmonary hypertension and/or RV dysfunction
- Full stomach (recently eaten)
Eligibility is decided by the study team after screening; this overview does not establish that a patient qualifies. Full inclusion and exclusion criteria.
Interventions
| Intervention | Type | Arms |
|---|---|---|
| Optiflow F&P 850™ SystemAlso: High flow nasal cannulaOptiflow™ (Fisher \& Paykel Healthcare Limited, East Tamaki, Auckland-New Zealand) offers the ability to comfortably deliver a complete range of oxygen concentrations and flows to extend the traditional boundaries of oxygen therapy. This will be placed on the patient immediately upon entering the operating room for 5 minutes, at 50 liters per minute then increased to 70 liters per minute after induction. | Device | Preoxygenation via hi flow nasal cannula |
| facemaskAlso: face maskWe will apply the facemask to the patient immediately upon entering the operating room to pre-oxygenate for five minutes. | Device | Preoxygenation with face mask |
| RocuroniumRocuronium will be administered after the ability to mask ventilate is determined. | Drug | Preoxygenation via hi flow nasal cannula, Preoxygenation with face mask |
| PropofolPropofol infusion 50 micrograms to 150 micrograms will be administered immediately on induction to maintain sedation throughout apneic oxygenation. | Drug | Preoxygenation via hi flow nasal cannula, Preoxygenation with face mask |
| FentanylFentanyl will be administered at the beginning of induction, 2 micrograms per kilogram. | Drug | Preoxygenation via hi flow nasal cannula, Preoxygenation with face mask |
| MidazolamAlso: Versedmidazolam will be given upon induction, 1-2 milligrams at the anesthesiologist's discretion. | Drug | Preoxygenation via hi flow nasal cannula, Preoxygenation with face mask |
| C-MAC Premium Video Intubation Platform-KARL STORZAlso: videolaryngoscope and optical fiberoptic bronchoscopeAfter patient is induced, the 5.5mm flexible intubation video scope (C-MAC Premium Video Intubation Platform-KARL STORZ) will then be introduced into the oropharynx and advanced into the trachea with the assistance of the C-MAC video laryngoscope (3 or 4 blade based on anesthesiologist's discretion). | Device | Preoxygenation via hi flow nasal cannula, Preoxygenation with face mask |
Primary outcome
Time to desaturation
Time frame: up to 10 minutes
Intraoperatively, apneic time will be record from the time of administration of the muscle relaxant. The time until the first desaturation will be recorded. The maximum time of measurement will be 10 minutes.
2 secondary outcomes
Time until hypercarbia > 65 mmHg
Time frame: up to 10 minutes
Assess correlation between end tidal CO2 and transcutaneous CO2 monitoring
Time frame: up to 10 minutes
Results and safety
The study was withdrawn before enrolling participants, so there are no results.
Research links
- Official record on ClinicalTrials.govLast updated by the sponsor 27 Mar 2018.
- Background: PubMed 8416477Locke RG, Wolfson MR, Shaffer TH, Rubenstein SD, Greenspan JS. Inadvertent administration of positive end-distending pressure during nasal cannula flow. Pediatrics. 1993 Jan;91(1):135-8.
- Background: PubMed 25981908Frat JP, Thille AW, Mercat A, Girault C, Ragot S, Perbet S, Prat G, Boulain T, Morawiec E, Cottereau A, Devaquet J, Nseir S, Razazi K, Mira JP, Argaud L, Chakarian JC, Ricard JD, Wittebole X, Chevalier S, Herbland A, Fartoukh M, Constantin JM, Tonnelier JM, Pierrot M, Mathonnet A, Beduneau G, Deletage-Metreau C, Richard JC, Brochard L, Robert R; FLORALI Study Group; REVA Network. High-flow oxygen through nasal cannula in acute hypoxemic respiratory failure. N Engl J Med. 2015 Jun 4;372(23):2185-96. doi: 10.1056/NEJMoa1503326. Epub 2015 May 17.
- Background: PubMed 26747218Hayes-Bradley C, Lewis A, Burns B, Miller M. Efficacy of Nasal Cannula Oxygen as a Preoxygenation Adjunct in Emergency Airway Management. Ann Emerg Med. 2016 Aug;68(2):174-80. doi: 10.1016/j.annemergmed.2015.11.012. Epub 2015 Dec 31.
- Background: PubMed 26253608Badiger S, John M, Fearnley RA, Ahmad I. Optimizing oxygenation and intubation conditions during awake fibre-optic intubation using a high-flow nasal oxygen-delivery system. Br J Anaesth. 2015 Oct;115(4):629-32. doi: 10.1093/bja/aev262. Epub 2015 Aug 7.
- Background: PubMed 25529351Simon M, Braune S, Frings D, Wiontzek AK, Klose H, Kluge S. High-flow nasal cannula oxygen versus non-invasive ventilation in patients with acute hypoxaemic respiratory failure undergoing flexible bronchoscopy--a prospective randomised trial. Crit Care. 2014 Dec 22;18(6):712. doi: 10.1186/s13054-014-0712-9.
- Background: PubMed 25169847Miyagi K, Haranaga S, Higa F, Tateyama M, Fujita J. Implementation of bronchoalveolar lavage using a high-flow nasal cannula in five cases of acute respiratory failure. Respir Investig. 2014 Sep;52(5):310-4. doi: 10.1016/j.resinv.2014.06.006. Epub 2014 Jul 25.
- Background: PubMed 9212140Gottschalk A, Mirza N, Weinstein GS, Edwards MW. Capnography during jet ventilation for laryngoscopy. Anesth Analg. 1997 Jul;85(1):155-9. doi: 10.1097/00000539-199707000-00028.
- Background: PubMed 25866645Nishimura M. High-flow nasal cannula oxygen therapy in adults. J Intensive Care. 2015 Mar 31;3(1):15. doi: 10.1186/s40560-015-0084-5. eCollection 2015.
- Background: PubMed 25388828Patel A, Nouraei SA. Transnasal Humidified Rapid-Insufflation Ventilatory Exchange (THRIVE): a physiological method of increasing apnoea time in patients with difficult airways. Anaesthesia. 2015 Mar;70(3):323-9. doi: 10.1111/anae.12923. Epub 2014 Nov 10.
- Background: PubMed 25003980Maggiore SM, Idone FA, Vaschetto R, Festa R, Cataldo A, Antonicelli F, Montini L, De Gaetano A, Navalesi P, Antonelli M. Nasal high-flow versus Venturi mask oxygen therapy after extubation. Effects on oxygenation, comfort, and clinical outcome. Am J Respir Crit Care Med. 2014 Aug 1;190(3):282-8. doi: 10.1164/rccm.201402-0364OC.
- Background: PubMed 23810609Aceto P, Perilli V, Modesti C, Ciocchetti P, Vitale F, Sollazzi L. Airway management in obese patients. Surg Obes Relat Dis. 2013 Sep-Oct;9(5):809-15. doi: 10.1016/j.soard.2013.04.013. Epub 2013 May 6.
- Background: PubMed 23836064Murphy C, Wong DT. Airway management and oxygenation in obese patients. Can J Anaesth. 2013 Sep;60(9):929-45. doi: 10.1007/s12630-013-9991-x. Epub 2013 Jul 9.
- Individual participant dataSharing planned: Yes. This is a collaborative study, so the information will be shared with the researchers in Texas. However, we do not plan to use this information for other studies.
Related trials for Obesity, Morbid
Not yet recruitingObservational study
Pilot Study on the Effectiveness and Safety of OPTILENE® SILVER MESH ELASTIC in Prevention of Surgical Site Infection (SSI) and Incisional Hernia (IH)
Abdominal Aortic Aneurysm, Morbid Obesity
Not yet recruitingObservational study
Evaluating Metabolic Health in Individuals With Extreme Obesity
BMI>40
Enrolling by invitationObservational study
Bariatric Surgery Registry
Obesity, Morbid
Not yet recruitingObservational study
Serum Estradiol and Endometrial Thickness After Bariatric Surgery in Postmenopausal Women With Obesity
Obesity, Morbid, Postmenopause
Active, not recruiting
Mindfulness Based Eating Awareness Training for Bariatric Surgery Patients
Obesity, Morbid, Eating Disorder Symptom
Referral and contact
AzTrials does not enrol participants or take referrals. Contact the study team or a site listed below; they decide who can take part. This study is not recruiting at the moment.
Irene Osborn, MD study director
Montefiore Medical Center
Questions about this trial
What is this clinical trial studying?
A study testing Optiflow F&P 850™ System, facemask and Rocuronium in people with Obesity, Morbid, run by Montefiore Medical Center.
The full registered description is in the About this study section and the official record.
Who may be eligible to take part?
The sponsor lists 3 inclusion and 10 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.
Is this clinical trial currently recruiting?
The record says: withdrawn, as of the sponsor's last update on 27 Mar 2018. Status can change between updates, so confirm with the study contact before making plans.
What are the possible benefits and risks?
They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.
Are results available for this study?
The study was withdrawn before enrolling participants, so there are no results.
How can a doctor refer a patient or contact the research team?
The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.
What does the primary outcome measure?
Time to desaturation (time frame: up to 10 minutes). It is what the study was designed to measure, not a finding.
Where can I read the original study information?
On the ClinicalTrials.gov record for NCT03009877, which also lists 22 linked publications.
Does a listing mean the treatment is approved or proven to work?
No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.
How often is this information updated?
AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 27 Mar 2018.