Investigators aim to compare two supraglottic airway devices; the i-gel and the newly developed laryngeal mask airway protector in terms of airway sealing effect, the insertion success rate, and the incidence of complications in anesthetized patients. Read more about this study

Who is it for?
Ages 20 years and older
Conditions the study is for
Mechanical Ventilation
What is being tested?
I-gel and Laryngeal mask airway protector
Type of treatment
Medical device
Could I receive a placebo?
No, everyone receives an active treatment
How many people
110 participants
Where
1 siteSouth Korea
Study dates
1 May 2017to 20 Jan 2018
Phase
Interventional
Are there results?
None posted in the registry

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 20 years and older
  • All sexes
  • No healthy volunteers
  • Adult, Older adult

Who may be able to join

  • Requirement for mechanical ventilation under general anesthesia

Who cannot join

  • Surgical position other than supine position
  • Tumors or anatomical abnormalities in the upper airway
  • Known or predicted difficult airway
  • Body mass index > 30 kg/m2
  • Required postoperative mechanical ventilation
  • Head and neck surgery
  • Aspiration tendency

Trial locations and contacts

1 site in 1 country.

South Korea1 site
  • Seoul Metropolitan Government Seoul National University Boramae Medical Center

    Seoul, 156-707

Other trials in South Korea

About this study

Official title: Comparison of the LMA Protector and the I-gel in Anesthetized Patients.

Investigators aim to compare two supraglottic airway devices; the i-gel and the newly developed laryngeal mask airway protector in terms of airway sealing effect, the insertion success rate, and the incidence of complications in anesthetized patients.

Being tested
I-gel, Laryngeal mask airway protector
Keywords
I-gel, Laryngeal mask airway protector

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • I-gelDevice

    After the induction of anesthesia, i-gel is inserted along the palatopharyngeal curve.

  • Laryngeal mask airway protectorDevice

    After the inudction of anesthesia, laryngeal mask airway protector is inserted along the palatopharyngeal curve, and the cuff is inflated.

Study groups in NCT03078517
Study groupRoleWhat they receive
I-gel groupActive comparatorAfter the induction of anesthesia, I-gel is inserted into the oropharyngeal space.
Receives: Device: I-gel
LMA protector groupExperimentalAfter the induction of anesthesia, laryngeal mask airway protector is inserted into the oropharyngeal space.
Receives: Device: Laryngeal mask airway protector

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. Oropharyngeal airway leak pressure

    Oropharyngeal airway leak pressure is measured by closing the expiratory valve of the circle system at a fresh gas flow of 3 L/min and observing the airway pressure at equilibrium.

    Measured: At 5 min after the insertion of i-gel or LMA protector

Secondary outcomes (7)
  1. Number of insertion attempt for the successful placement

    The numbers of insertion attempt for successful placement are counted.

    Measured: During the insertion of i-gel or LMA protector

  2. Insertion time

    Insertion time is defined as the time from picking up the device to confirming successful placement (the appearance of the ETCO2 on the monitor screen).

    Measured: During the insertion of i-gel or LMA protector

  3. Ease of insertion

    Ease of insertion is defined as follows. Easy: requiring no additional maneuver, fair: requiring 1 additional maneuver, difficult: requiring more than 1 additional maneuver.

    Measured: During the insertion of i-gel or LMA protector

  4. Ease of gastric tube insertion

    Ease of garstic tube insertion is assessed as follows; easy, difficult, impossible.

    Measured: At 25 min after the insertion of i-gel or LMA protector

  5. The accuracy of insertion location of the device in the oropharyngeal space

    After insertion of the device, the insertion location is assessed using a fiberoptic bronchoscope; 4, only the vocal cords seen; 3, vocal cords and posterior part of the epiglottis seen; 2, vocal cords and anterior part of the epiglottis seen; 1, vocal cords not seen, but adequate ventilation.

    Measured: At 15 min after the insertion of i-gel or LMA protector

  6. Blood staining on the i-gel or LMA protector

    After removal of the device, the presence of blood staining on the device is checked.

    Measured: Immediately after removal of i-gel or LMA protector

  7. The incidence and severity of postoperative sore throat

    Postoperative sore throat is assessed using a numerical rating scale (0-100 point).

    Measured: At 1 and 24 h after surgery

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted13 Mar 2017
  2. Study start1 May 2017
  3. Primary completion19 Jan 2018
  4. Study completion20 Jan 2018

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Interventional
Phase
Phase N/A
Primary purpose
Prevention
Allocation
Randomised
Intervention model
Parallel groups
Masking
Single blind
Who is masked
Participant
Enrolment
110 participants (actual)
IDs, dates and publications
ClinicalTrials.gov ID
NCT03078517
Sponsor's protocol ID
20170104
Status last verified
Feb 2018
First submitted
4 Jan 2017
Last updated
5 Feb 2018
Results posted
No
Data monitoring committee
Yes
FDA-regulated drug
No
FDA-regulated device
No
Individual data sharing
No

Publications

  • Chang JE, Kim H, Lee JM, Min SW, Won D, Jun K, Hwang JY. A prospective, randomized comparison of the LMA-protector and i-gel in paralyzed, anesthetized patients. BMC Anesthesiol. 2019 Jul 4;19(1):118. doi: 10.1186/s12871-019-0785-8.

    PubMed 31272379

Questions about this trial

What is this clinical trial studying?

A study testing I-gel and Laryngeal mask airway protector in people with Mechanical Ventilation, run by SMG-SNU Boramae Medical Center at 1 site in South Korea.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 1 inclusion and 7 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: finished, as of the sponsor's last update on 5 Feb 2018. Status can change between updates, so confirm with the study contact before making plans.

Where is the study taking place?

The record lists 1 site in South Korea. Whether a site is taking part right now should be confirmed with that site. See every site.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.

How can a doctor refer a patient or contact the research team?

The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

Oropharyngeal airway leak pressure (time frame: At 5 min after the insertion of i-gel or LMA protector). It is what the study was designed to measure, not a finding.

Where can I read the original study information?

On the ClinicalTrials.gov record for NCT03078517, which also lists 1 linked publication.

Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 5 Feb 2018.

Free account

Log in to keep searching

You’ve used your 3 free searches. AzTrials is free: log in or create a free account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in