Premature BirthNCT03085329
A Study to Evaluate the Efficacy of Seattle-PAP for the Respiratory Support of Premature Infants
A study testing Seattle-PAP and Conventional bubble nasal CPAP in people with Premature Birth, run by Seattle Children's Hospital at 1 site in United States.
Trial summary
This study is designed to test the hypothesis that among infants born at less than 30 weeks, weighing less than 1500 g at delivery, and receiving initial respiratory support non-invasively or on invasive respiratory support and meeting extubation criteria in the first 72 h of life, fewer neonates managed on… Read more about this study
- Who is it for?
- Ages Up to 30 weeks
- Conditions the study is for
- Premature Birth
- What is being tested?
- Seattle-PAP and Conventional bubble nasal CPAP
- Type of treatment
- Medical device
- Could I receive a placebo?
- No, everyone receives an active treatment
- How many people
- 220 participants
- Where
- 1 siteUnited States
- Study dates
- 10 Feb 2017to 9 Feb 2019
- Phase
- Interventional
- Are there results?
- None posted in the registry
Key requirements
Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.
- Ages Up to 30 weeks
- All sexes
- No healthy volunteers
- Child
Who may be able to join
- Informed consent from parents, less than 30 weeks postmenstrual age at birth, within 72 h of postnatal age spontaneously breathing and able to sustain SaO2 of greater than 90% on less than or equal to FiO2 of 0.40 and 6 cm H2O pressure
Who cannot join
- Cardiopulmonary malformations (cardiac valve atresia, lung atresia)
- Congenital malformations (examples: anencephaly, omphalocele, Tetralogy of Fallot) Genetic anomalies (examples: Trisomy 21, Trisomy 18).
Trial locations and contacts
1 site in 1 country.
United States1 site, 1 recruiting
- Recruiting
Nationwide Children's Hospital
Columbus, Ohio, 43205
Carl H Backes, Jr., MD, 614-264-6374, carl.backesjr@nationwidechildrens.org
Michael Stenger, MD, 614 264-3555, michael.stenger@nationwidechildrens.org
About this study
This study is designed to test the hypothesis that among infants born at less than 30 weeks, weighing less than 1500 g at delivery, and receiving initial respiratory support non-invasively or on invasive respiratory support and meeting extubation criteria in the first 72 h of life, fewer neonates managed on Seattle--PAP will require endotracheal intubation and conventional mechanical ventilation (CMV) than will neonates managed from birth on bubble nasal continuous positive airway pressure (Bn-CPAP) using the Fischer- \& Paykel (FP) device. Neonates on nasal continuous positive airway pressure (CPAP) in the delivery room or who are stabilized on mechanical ventilation as their initial form of respiratory support and meet our criteria for extubation within 72 h of birth will be eligible for randomization and study.
The primary endpoint of this study is the cumulative incidence of respiratory failure requiring intubation that occurs in patients after randomization and before 36 weeks post menstrual age (PMA) or discharge, whichever comes first. Presently, the literature supports that this age group typically exhibits intubation rates of 50% or more, which is consistent with the data from the Nationwide Children's Hospital/Ohio State University (NCH/OSU) Neonatal Intensive Care Unit (NICU).
Read the detailed description
Parents / Mothers with impending pre-term delivery at <30 weeks of gestation will be approached for informed consent to participate. If consent is given prior to delivery, upon delivery the neonate may be randomly assigned to either Fisher \& Paykel CPAP (conventional approach) or Seattle--PAP (experimental approach).
First 72 hours of life: 1) Neonates able to breathe spontaneously on less than 40% oxygen after initial resuscitative efforts and would normally be placed on CPAP will be randomly assigned to one of the two treatment groups using sealed cards generated by a variable block randomization scheme. 2) Neonates requiring increased support after initial resuscitation (intubation, >40% oxygen by CPAP) will not initially be randomized. However, if within the first 72 hours of life, the infant meets NCH criteria for extubation, randomization to CPAP delivery method will be performed. 3) Neonates born at <30 weeks gestation who were intubated at birth and are unable to be weaned from ventilator support will be removed from the study.
72 Hours - 32 Weeks of Life: 1) Neonates from the first period (First 72 Hours of Life, above) who remain on CPAP will continue on randomly assigned CPAP methodology. 2) Neonates from the first period, who failed stabilization on CPAP and required intubation, but are able to be extubated to CPAP will be placed back on their assigned CPAP method. 3) Attempts will be made to wean back to assigned CPAP method any neonates who are >72 hours old and require intubation beyond this period for any reason. 4) If unable to wean back to CPAP prior to 32 weeks of age, these patients will be removed from the study.
CPAP Failure (Sub-Group 1): For the neonates initially assigned to CPAP in the delivery room (sub-group 1), respiratory failure secondary to hyaline membrane disease is recognized as a common occurrence. If a patient assigned to this group, regardless of CPAP methodology, requires a fraction of inspired oxygen (FiO2) greater than 0.40 on CPAP of 6 cm of water (H2O), or is deemed to require intubation for adequate oxygenation, this will be considered a failure of CPAP stabilization. These patients, however, may remain in the study if it becomes clinically feasible to return them back to their assigned CPAP method prior to 72 hours of life. If this is unable to be done, they will be removed from the study.
CPAP Failure (Sub-Group 2): Any neonate that requires FiO2 greater than 0.40 on CPAP of 6 cm H2O or intubation beyond the first 72 hours of life will also be considered CPAP failures. Like those assigned to sub-group 1, these patients may remain in the study if it becomes clinically feasible to return them back to their assigned CPAP method prior to 32 weeks of life. If this is unable to be done, they will be removed from the study.
All patients who are not removed from the study as outlined above or due to other unforeseen circumstances will be monitored to discharge for any change in ventilation and ventilation requirement status. Routine care, including clinical exams and procedures (echocardiography, ultrasound, eye exams, x--rays) that would be considered standard of care for these patients will be performed at the medical discretion of the assigned care providers. No changes other than the type of CPAP device used (if applicable) will be necessary to routine practice.
Transfers to NCH: [From Outside Hospital] - Neonates born at an outside institution who meet the inclusion criteria (<30 weeks GA, able to spontaneously breathe by 72 hours of life or were initially placed on CPAP and failed, <32 weeks of age) and whose parents can be reached to obtain consent will be considered for inclusion in this research study. [Transfers from Ohio State University (OSU) Hospital] - It is recognized that many neonates born at OSU will require transport to NCH for further medical care. Having fulfilled inclusion criteria at OSU, transport to NCH will not result in removal from the study.
Cardiopulmonary Monitoring: All neonates are monitored in the NICU using pulse oximetry as part of normal practice. Many potential subjects in this study are also monitored through blood tests and arterial catheters, the latter of which are normally not intended for long term use.
Pressure Monitoring: A stand-alone Data Acquisition and Recording Instrument (DARCI) that measures pressure (i.e., positive airway pressure [PAW]) will be attached to the ventilation circuit. The DARCI unit is equipped with a standard International Organization for Standardization (ISO)19054 pole mount fitting attached on the back. A medical grade plug-in transformer provides electrical power (120 volts alternating current (AC) to 5 volts direct current (DC)). An internal battery and on-board non-volatile memory provide continuous data processing and storage in the event of power interruption or loss. A start button with a green light emitting diode (LED) and a stop button with a red LED provide the operational interface to the user during setup and changes in ventilation circuits. Initial programming and downloading of recorded pressure data will be accomplished using a laptop personal computer (PC) with interface application software installed.
- Conditions
- Premature Birth
- Being tested
- Seattle-PAP, Conventional bubble nasal CPAP
- Keywords
- bubble nasal continuous positive airway pressure, respiratory support
- Medical subject headings
- Premature Birth
What participants receive
What participants receive. In a randomised study each person is assigned to one group by chance.
Seattle-PAPDevice
Seattle-PAP is a modified bubble CPAP device that has been given 510(k) clearance by the US FDA (K131502, October 11, 2013) and is thus recognized as substantially equivalent to other approved devices on the market. Results of a recently completed study in infants indicate that Bn-CPAP is associated with lower effort to breathe by spontaneously breathing premature infants.
Conventional bubble nasal CPAPDevice
Infants enrolled in the study and randomized to this arm will be given respiratory support by bubble nasal CPAP using the Fisher \& Paykel bubbler device, which is the standard of care at Nationwide Children's.
| Study group | Role | What they receive |
|---|---|---|
| Seattle-PAP | Experimental | bubble nasal cpap respiratory support with Seattle-PAP bubbler device, with all other aspects of care per usual care noninvasive respiratory support Receives: Device: Seattle-PAP |
| Conventional bubble nasal CPAP | Experimental | qualified and enrolled infants randomized to this arm will receive noninvasive respiratory support by bubble nasal CPAP, using the Fisher \& Paykel bubbler, which is the standard of care at Nationwide Children's. Receives: Device: Conventional bubble nasal CPAP |
What is being measured
The primary outcome is the main question the study is designed to answer.
Failure of noninvasive respiratory support
The primary endpoint of this study is the cumulative incidence of respiratory failure requiring intubation. The principal criteria for failure of support are the requirement of an FiO2 greater than 0.40 and CPAP of greater than 6 cm H2O to maintain SaO2 of at least 90%. Support failure also can be declared by the responsible clinician based on best clinical judgment, but any declarations not based on the stated criteria will require written explanations.
Measured: After randomization and before 36 weeks postmenstrual age (PMA) or discharge from the hospital, whichever comes first.
Secondary outcomes (8)
pneumothorax
by diagnosis of clinical care team
Measured: After randomization and before 36 weeks postmenstrual age (PMA) or discharge from the hospital, whichever comes first.
nasal trauma
by diagnosis of clinical care team
Measured: After randomization and before 36 weeks postmenstrual age (PMA) or discharge from the hospital, whichever comes first.
supplemental oxygen requirement
if an infant fails for one hour or more fails to sustain an oxygen saturation (SaO2) of at least 90 percent, with FiO2 of 0.40 or less and 6 cm of water pressure (cmH2O) or less CPAP pressure.
Measured: After randomization and before 36 weeks postmenstrual age (PMA) or discharge from the hospital, whichever comes first.
ventilation-associated sepsis
by diagnosis of clinical care team
Measured: After randomization and before 36 weeks postmenstrual age (PMA) or discharge from the hospital, whichever comes first.
death of infant
infant declared dead by responsible clinical care personnel
Measured: After randomization and before 36 weeks postmenstrual age (PMA) or discharge from the hospital, whichever comes first.
Central nervous system (CNS) injury
intraventricular hemorrhage and/or periventricular leukomalacia
Measured: After randomization and before 36 weeks postmenstrual age (PMA) or discharge from the hospital, whichever comes first.
gastrointestinal complications
necrotizing enterocolitis and/or spontaneous intestinal perforation
Measured: After randomization and before 36 weeks postmenstrual age (PMA) or discharge from the hospital, whichever comes first.
retinopathy of prematurity
by diagnosis of clinical care team
Measured: After randomization and before 36 weeks postmenstrual age (PMA) or discharge from the hospital, whichever comes first.
Timeline
From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.
- First posted21 Mar 2017
- Study start10 Feb 2017
- Primary completion31 Oct 2018 (estimated)
- Study completion9 Feb 2019 (estimated)
Resources
- Official record on ClinicalTrials.govThe registry entry this page is built from, with its full change history.
- Publications (5)Papers the sponsor has linked to this study.
- Other trials for Premature BirthStudies of the same condition, open and under way.
- More trials run by Seattle Children's HospitalThe sponsor's other registered studies.
- What the trial phases meanHow a treatment moves from first tests in people to approval.
More details
For doctors and researchers: how the study is designed, who runs it, and its registry IDs.
Study design
- Study type
- Interventional
- Phase
- Phase N/A
- Primary purpose
- Treatment
- Allocation
- Randomised
- Intervention model
- Parallel groups
- Model description
- With written informed consent from the mother or parents, infants born at less than 30 weeks gestation and who are capable of breathing spontaneously within the first 72 hours postnatal, will be supported by bubble nasal continuous positive airway pressure (Bn-CPAP), randomized to the standard device from Fisher \& Paykel or to Seattle-PAP.
- Masking
- None (open label)
- Enrolment
- 220 participants (estimated)
Sponsor and investigators
- Lead sponsor
- Seattle Children's Hospital
- Sponsor type
- University, hospital or other
- Collaborators
- Nationwide Children's Hospital
- Responsible party
- Principal investigator, Charles Smith, Seattle Children's Hospital
- Investigators
- Carl H Backes, Jr., MD, Principal investigator, Nationwide Children's Hospital
IDs, dates and publications
- ClinicalTrials.gov ID
- NCT03085329
- Sponsor's protocol ID
- Seattle-PAP 002
- Status last verified
- Mar 2017
- First submitted
- 6 Mar 2017
- Last updated
- 22 Mar 2017
- Results posted
- No
- Data monitoring committee
- Yes
- FDA-regulated drug
- No
- FDA-regulated device
- Yes
- Individual data sharing
- Yes: The data will be available for download via Globus sharing services from the Seattle-PAP shared endpoint.
Publications
Diblasi RM, Zignego JC, Tang DM, Hildebrandt J, Smith CV, Hansen TN, Richardson CP. Noninvasive respiratory support of juvenile rabbits by high-amplitude bubble continuous positive airway pressure. Pediatr Res. 2010 Jun;67(6):624-9. doi: 10.1203/PDR.0b013e3181dcd580.
PubMed 20308940Welty SE. Continuous Positive Airway Pressure Strategies with Bubble Nasal Continuous Positive Airway Pressure: Not All Bubbling Is the Same: The Seattle Positive Airway Pressure System. Clin Perinatol. 2016 Dec;43(4):661-671. doi: 10.1016/j.clp.2016.07.004.
PubMed 27837751Diblasi RM, Zignego JC, Smith CV, Hansen TN, Richardson CP. Effective gas exchange in paralyzed juvenile rabbits using simple, inexpensive respiratory support devices. Pediatr Res. 2010 Dec;68(6):526-30. doi: 10.1203/PDR.0b013e3181f985f0.
PubMed 20814347Kirpalani H, Millar D, Lemyre B, Yoder BA, Chiu A, Roberts RS; NIPPV Study Group. A trial comparing noninvasive ventilation strategies in preterm infants. N Engl J Med. 2013 Aug 15;369(7):611-20. doi: 10.1056/NEJMoa1214533.
PubMed 23944299Backes CH, Notestine JL, Lamp JM, Balough JC, Notestine AM, Alfred CM, Kern JM, Stenger MR, Rivera BK, Moallem M, Miller RR, Naik A, Cooper JN, Howard CR, Welty SE, Hillman NH, Zupancic JAF, Stanberry LI, Hansen TN, Smith CV. Evaluating the efficacy of Seattle-PAP for the respiratory support of premature neonates: study protocol for a randomized controlled trial. Trials. 2019 Jan 18;20(1):63. doi: 10.1186/s13063-018-3166-6.
PubMed 30658678
Study at a glance
From the registry record, last updated by the sponsor on 22 Mar 2017. Recruitment status is as the sponsor reported it: confirm with the study team.
- Official title
- A Study to Evaluate the Efficacy of Seattle-PAP for the Respiratory Support of Premature Infants
- ClinicalTrials.gov ID
- NCT03085329
- Acronym / sponsor ID
- Seattle-PAP 002
- Conditions
- Premature Birth
- Keywords
- bubble nasal continuous positive airway pressure, respiratory support
- Study type
- Interventional
- Recruitment status
- Unknown status
- Enrolment
- 220 participants (estimated)
- Lead sponsor
- Seattle Children's HospitalUniversity, hospital or other
- Collaborators
- Nationwide Children's Hospital
- Study start
- 10 Feb 2017 (actual)
- Primary completion
- 31 Oct 2018 (estimated)
- Study completion
- 9 Feb 2019 (estimated)
- First posted
- 21 Mar 2017 (actual)
- Results
- Not posted in the source record
Clinical summary
The research question as the sponsor registered it. This describes what the study plans to test, not what it found.
This study is designed to test the hypothesis that among infants born at less than 30 weeks, weighing less than 1500 g at delivery, and receiving initial respiratory support non-invasively or on invasive respiratory support and meeting extubation criteria in the first 72 h of life, fewer neonates managed on Seattle--PAP will require endotracheal intubation and conventional mechanical ventilation (CMV) than will neonates managed from birth on bubble nasal continuous positive airway pressure (Bn-CPAP) using the Fischer- \& Paykel (FP) device. Neonates on nasal continuous positive airway pressure (CPAP) in the delivery room or who are stabilized on mechanical ventilation as their initial form of respiratory support and meet our criteria for extubation within 72 h of birth will be eligible for randomization and study.
The primary endpoint of this study is the cumulative incidence of respiratory failure requiring intubation that occurs in patients after randomization and before 36 weeks post menstrual age (PMA) or discharge, whichever comes first. Presently, the literature supports that this age group typically exhibits intubation rates of 50% or more, which is consistent with the data from the Nationwide Children's Hospital/Ohio State University (NCH/OSU) Neonatal Intensive Care Unit (NICU).
Detailed description
Parents / Mothers with impending pre-term delivery at <30 weeks of gestation will be approached for informed consent to participate. If consent is given prior to delivery, upon delivery the neonate may be randomly assigned to either Fisher \& Paykel CPAP (conventional approach) or Seattle--PAP (experimental approach).
First 72 hours of life: 1) Neonates able to breathe spontaneously on less than 40% oxygen after initial resuscitative efforts and would normally be placed on CPAP will be randomly assigned to one of the two treatment groups using sealed cards generated by a variable block randomization scheme. 2) Neonates requiring increased support after initial resuscitation (intubation, >40% oxygen by CPAP) will not initially be randomized. However, if within the first 72 hours of life, the infant meets NCH criteria for extubation, randomization to CPAP delivery method will be performed. 3) Neonates born at <30 weeks gestation who were intubated at birth and are unable to be weaned from ventilator support will be removed from the study.
72 Hours - 32 Weeks of Life: 1) Neonates from the first period (First 72 Hours of Life, above) who remain on CPAP will continue on randomly assigned CPAP methodology. 2) Neonates from the first period, who failed stabilization on CPAP and required intubation, but are able to be extubated to CPAP will be placed back on their assigned CPAP method. 3) Attempts will be made to wean back to assigned CPAP method any neonates who are >72 hours old and require intubation beyond this period for any reason. 4) If unable to wean back to CPAP prior to 32 weeks of age, these patients will be removed from the study.
CPAP Failure (Sub-Group 1): For the neonates initially assigned to CPAP in the delivery room (sub-group 1), respiratory failure secondary to hyaline membrane disease is recognized as a common occurrence. If a patient assigned to this group, regardless of CPAP methodology, requires a fraction of inspired oxygen (FiO2) greater than 0.40 on CPAP of 6 cm of water (H2O), or is deemed to require intubation for adequate oxygenation, this will be considered a failure of CPAP stabilization. These patients, however, may remain in the study if it becomes clinically feasible to return them back to their assigned CPAP method prior to 72 hours of life. If this is unable to be done, they will be removed from the study.
CPAP Failure (Sub-Group 2): Any neonate that requires FiO2 greater than 0.40 on CPAP of 6 cm H2O or intubation beyond the first 72 hours of life will also be considered CPAP failures. Like those assigned to sub-group 1, these patients may remain in the study if it becomes clinically feasible to return them back to their assigned CPAP method prior to 32 weeks of life. If this is unable to be done, they will be removed from the study.
All patients who are not removed from the study as outlined above or due to other unforeseen circumstances will be monitored to discharge for any change in ventilation and ventilation requirement status. Routine care, including clinical exams and procedures (echocardiography, ultrasound, eye exams, x--rays) that would be considered standard of care for these patients will be performed at the medical discretion of the assigned care providers. No changes other than the type of CPAP device used (if applicable) will be necessary to routine practice.
Transfers to NCH: [From Outside Hospital] - Neonates born at an outside institution who meet the inclusion criteria (<30 weeks GA, able to spontaneously breathe by 72 hours of life or were initially placed on CPAP and failed, <32 weeks of age) and whose parents can be reached to obtain consent will be considered for inclusion in this research study. [Transfers from Ohio State University (OSU) Hospital] - It is recognized that many neonates born at OSU will require transport to NCH for further medical care. Having fulfilled inclusion criteria at OSU, transport to NCH will not result in removal from the study.
Cardiopulmonary Monitoring: All neonates are monitored in the NICU using pulse oximetry as part of normal practice. Many potential subjects in this study are also monitored through blood tests and arterial catheters, the latter of which are normally not intended for long term use.
Pressure Monitoring: A stand-alone Data Acquisition and Recording Instrument (DARCI) that measures pressure (i.e., positive airway pressure [PAW]) will be attached to the ventilation circuit. The DARCI unit is equipped with a standard International Organization for Standardization (ISO)19054 pole mount fitting attached on the back. A medical grade plug-in transformer provides electrical power (120 volts alternating current (AC) to 5 volts direct current (DC)). An internal battery and on-board non-volatile memory provide continuous data processing and storage in the event of power interruption or loss. A start button with a green light emitting diode (LED) and a stop button with a red LED provide the operational interface to the user during setup and changes in ventilation circuits. Initial programming and downloading of recorded pressure data will be accomplished using a laptop personal computer (PC) with interface application software installed.
Study design
- Primary purpose
- Treatment
- Allocation
- Randomised
- Intervention model
- Parallel groups
- Masking
- None (open label)
- Number of arms
- 2
- Model description
- With written informed consent from the mother or parents, infants born at less than 30 weeks gestation and who are capable of breathing spontaneously within the first 72 hours postnatal, will be supported by bubble nasal continuous positive airway pressure (Bn-CPAP), randomized to the standard device from Fisher \& Paykel or to Seattle-PAP.
| Arm | Type | Receives |
|---|---|---|
| Seattle-PAP | Experimental | Device: Seattle-PAPbubble nasal cpap respiratory support with Seattle-PAP bubbler device, with all other aspects of care per usual care noninvasive respiratory support |
| Conventional bubble nasal CPAP | Experimental | Device: Conventional bubble nasal CPAPqualified and enrolled infants randomized to this arm will receive noninvasive respiratory support by bubble nasal CPAP, using the Fisher \& Paykel bubbler, which is the standard of care at Nationwide Children's. |
Who may qualify
- Ages
- Up to 30 weeks
- Sex
- All
- Healthy volunteers
- Not accepted
- Age groups
- Child
Key inclusion criteria (1 listed)
- Informed consent from parents, less than 30 weeks postmenstrual age at birth, within 72 h of postnatal age spontaneously breathing and able to sustain SaO2 of greater than 90% on less than or equal to FiO2 of 0.40 and 6 cm H2O pressure
Key exclusion criteria (2 listed)
- Cardiopulmonary malformations (cardiac valve atresia, lung atresia)
- Congenital malformations (examples: anencephaly, omphalocele, Tetralogy of Fallot) Genetic anomalies (examples: Trisomy 21, Trisomy 18).
Eligibility is decided by the study team after screening; this overview does not establish that a patient qualifies. Full inclusion and exclusion criteria.
Interventions
| Intervention | Type | Arms |
|---|---|---|
| Seattle-PAPSeattle-PAP is a modified bubble CPAP device that has been given 510(k) clearance by the US FDA (K131502, October 11, 2013) and is thus recognized as substantially equivalent to other approved devices on the market. Results of a recently completed study in infants indicate that Bn-CPAP is associated with lower effort to breathe by spontaneously breathing premature infants. | Device | Seattle-PAP |
| Conventional bubble nasal CPAPInfants enrolled in the study and randomized to this arm will be given respiratory support by bubble nasal CPAP using the Fisher \& Paykel bubbler device, which is the standard of care at Nationwide Children's. | Device | Conventional bubble nasal CPAP |
Primary outcome
Failure of noninvasive respiratory support
Time frame: After randomization and before 36 weeks postmenstrual age (PMA) or discharge from the hospital, whichever comes first.
The primary endpoint of this study is the cumulative incidence of respiratory failure requiring intubation. The principal criteria for failure of support are the requirement of an FiO2 greater than 0.40 and CPAP of greater than 6 cm H2O to maintain SaO2 of at least 90%. Support failure also can be declared by the responsible clinician based on best clinical judgment, but any declarations not based on the stated criteria will require written explanations.
8 secondary outcomes
pneumothorax
Time frame: After randomization and before 36 weeks postmenstrual age (PMA) or discharge from the hospital, whichever comes first.
nasal trauma
Time frame: After randomization and before 36 weeks postmenstrual age (PMA) or discharge from the hospital, whichever comes first.
supplemental oxygen requirement
Time frame: After randomization and before 36 weeks postmenstrual age (PMA) or discharge from the hospital, whichever comes first.
ventilation-associated sepsis
Time frame: After randomization and before 36 weeks postmenstrual age (PMA) or discharge from the hospital, whichever comes first.
death of infant
Time frame: After randomization and before 36 weeks postmenstrual age (PMA) or discharge from the hospital, whichever comes first.
Central nervous system (CNS) injury
Time frame: After randomization and before 36 weeks postmenstrual age (PMA) or discharge from the hospital, whichever comes first.
gastrointestinal complications
Time frame: After randomization and before 36 weeks postmenstrual age (PMA) or discharge from the hospital, whichever comes first.
retinopathy of prematurity
Time frame: After randomization and before 36 weeks postmenstrual age (PMA) or discharge from the hospital, whichever comes first.
Results and safety
Results are not available in the source record.
Research links
- Official record on ClinicalTrials.govLast updated by the sponsor 22 Mar 2017.
- Background: PubMed 20308940Diblasi RM, Zignego JC, Tang DM, Hildebrandt J, Smith CV, Hansen TN, Richardson CP. Noninvasive respiratory support of juvenile rabbits by high-amplitude bubble continuous positive airway pressure. Pediatr Res. 2010 Jun;67(6):624-9. doi: 10.1203/PDR.0b013e3181dcd580.
- Results publication: PubMed 27837751Welty SE. Continuous Positive Airway Pressure Strategies with Bubble Nasal Continuous Positive Airway Pressure: Not All Bubbling Is the Same: The Seattle Positive Airway Pressure System. Clin Perinatol. 2016 Dec;43(4):661-671. doi: 10.1016/j.clp.2016.07.004.
- Results publication: PubMed 20814347Diblasi RM, Zignego JC, Smith CV, Hansen TN, Richardson CP. Effective gas exchange in paralyzed juvenile rabbits using simple, inexpensive respiratory support devices. Pediatr Res. 2010 Dec;68(6):526-30. doi: 10.1203/PDR.0b013e3181f985f0.
- Results publication: PubMed 23944299Kirpalani H, Millar D, Lemyre B, Yoder BA, Chiu A, Roberts RS; NIPPV Study Group. A trial comparing noninvasive ventilation strategies in preterm infants. N Engl J Med. 2013 Aug 15;369(7):611-20. doi: 10.1056/NEJMoa1214533.
- Derived from this study: PubMed 30658678Backes CH, Notestine JL, Lamp JM, Balough JC, Notestine AM, Alfred CM, Kern JM, Stenger MR, Rivera BK, Moallem M, Miller RR, Naik A, Cooper JN, Howard CR, Welty SE, Hillman NH, Zupancic JAF, Stanberry LI, Hansen TN, Smith CV. Evaluating the efficacy of Seattle-PAP for the respiratory support of premature neonates: study protocol for a randomized controlled trial. Trials. 2019 Jan 18;20(1):63. doi: 10.1186/s13063-018-3166-6.
- Individual participant dataSharing planned: Yes. The data will be available for download via Globus sharing services from the Seattle-PAP shared endpoint.
Related trials for Premature Birth
Not yet recruiting
nCPAP-NAVA-Backup Versus Standard nCPAP for Severe Apnea in Preterm Infants ≤28 Weeks
Apnea of Prematurity
Recruiting
Study of the Influence of Intraperitoneal Insufflation of CO2 by Laparoscopy on the Short-term Evolution of Premature Infants With Ulcerative Necrotizing Enterocolitis
Preterm Birth, Enterocolitis, Necrotizing
RecruitingObservational study
Multidimensional Dynamic Early Warning System for Neonatal Necrotizing Enterocolitis: A Multicenter Clinical Study
NEC - Necrotizing Enterocolitis
Recruiting
Optimization of Saturation Targets And Resuscitation Trial (OptiSTART)
Premature Infants, Bronchopulmonary Dysplasia
RecruitingObservational study
Growing Little PEAPODS Study
Premature Birth, Premature Infant
Referral and contact
AzTrials does not enrol participants or take referrals. Contact the study team or a site listed below; they decide who can take part. This study is not recruiting at the moment.
Carl H Backes, Jr., MD principal investigator
Nationwide Children's Hospital
1 site in 1 country: see every site and its status.
Questions about this trial
What is this clinical trial studying?
A study testing Seattle-PAP and Conventional bubble nasal CPAP in people with Premature Birth, run by Seattle Children's Hospital at 1 site in United States.
The full registered description is in the About this study section and the official record.
Who may be eligible to take part?
The sponsor lists 1 inclusion and 2 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.
Is this clinical trial currently recruiting?
The record says: status not confirmed, as of the sponsor's last update on 22 Mar 2017. Status can change between updates, so confirm with the study contact before making plans.
Where is the study taking place?
The record lists 1 site in United States. Whether a site is taking part right now should be confirmed with that site. See every site.
What are the possible benefits and risks?
They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.
Are results available for this study?
Results are not available in the source record.
How can a doctor refer a patient or contact the research team?
Contact Carl H Backes, Jr., MD (614 264-6374, carl.backesjr@nationwidechildrens.org), or a site near the patient. AzTrials does not enrol participants or take referrals.
What does the primary outcome measure?
Failure of noninvasive respiratory support (time frame: After randomization and before 36 weeks postmenstrual age (PMA) or discharge from the hospital, whichever comes first.). It is what the study was designed to measure, not a finding.
Where can I read the original study information?
On the ClinicalTrials.gov record for NCT03085329, which also lists 5 linked publications.
Does a listing mean the treatment is approved or proven to work?
No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.
How often is this information updated?
AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 22 Mar 2017.