AzTrials
AzTrials

Premature Ventricular ContractionPVCNCT03086902

Comparision of PVC Ablation Techniques

A study testing Radiofrequency Ablation Catheter and Cryo Ablation catheter in people with Premature Ventricular Contraction, run by Sheba Medical Center.

Unknown status

Status not confirmed. The sponsor has not verified this record for over two years, so it may be out of date.

Official record
Search all trials

Trial summary

Several reports have shown the utility of PVC ablation with cryo catheters. The aim of this study is to compare the outcomes and safety of Cryo vs. RF for PVCs. Read more about this study

Who is it for?
Ages 18 years and older
Conditions the study is for
Premature Ventricular Contraction
What is being tested?
Radiofrequency Ablation Catheter and Cryo Ablation catheter
Type of treatment
Medical device
Could I receive a placebo?
No, everyone receives an active treatment
How many people
88 participants
Where
No sites listed yet
Study dates
Dec 2018to Jul 2021
Phase
Interventional
Are there results?
None posted in the registry

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 18 years and older
  • All sexes
  • No healthy volunteers
  • Adult, Older adult

Who may be able to join

  • Patients referred for PVC ablation.
  • Age ≥ 18 years on a date of consent.

Who cannot join

  • Contraindications for ablation
  • Serious known concomitant disease with a life expectancy of < 1 year
  • Elderly patients >80 years of age
  • Pregnancy or nursing
  • Unwilling or unable to give informed consent

Trial locations and contacts

No sites are listed yet.

About this study

Official title: Cryo Ablation vs. Radiofrequency Catheter Ablation for Ventricular Premature Contractions

Several reports have shown the utility of PVC ablation with cryo catheters. The aim of this study is to compare the outcomes and safety of Cryo vs. RF for PVCs.

Read the detailed description

Background: Radiofrequency (RF) catheter ablation (CA) is an effective therapeutic strategy in eliminating refractory idiopathic ventricular outflow tract (OT) ventricular arrhythmias (VA). However, early and late recurrences occur commonly. RFCA has also been reported to be associated with collateral damage and pain. The use of Cryo ablation as a safer alternative energy source been previously described. In several reports Cryo was reported to successfully treat VA originating from the OT in the absence of ablation related pain and collateral damage to adjacent structures such as the coronaries. When comparing outcomes and complications of catheter ablation of VA from the papillary muscles of the left ventricle with either Cryo or RF, Cryo was found to be associated with significantly higher success rates and lower recurrence rates than RFCA.

Aim: To compare the outcomes and safety of Cryo vs. RF for PVCs. Methods: Patients with PVC VA will be randomized in a 1:1 fashion to RFCA or Cryo ablation. All procedures will be done using a 3-dimensional mapping system (EnSite™ NavX™ system, St. Jude Medical). Ablation will be performed at sites with earliest activation or at least pacemap exhibiting QRS morphology match of >11/12. Endpoint of procedure will be elimination and non inducibility of the clinical VA. All patients will undergo continuous monitoring for at least 12 hours post procedure and 12 lead Holter and exercise testing 1 month post procedure. Successful ablation will be defined as absence of clinical VA or > 50% reduction in arrhythmia burden on Holter in the absence of anti-arrhythmic medications.

Being tested
Radiofrequency Ablation Catheter, Cryo Ablation catheter
Keywords
Ablation; Cryo Energy; Radofrequency Ablation
Medical subject headings
Ventricular Premature Complexes

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • Radiofrequency Ablation CatheterDevice

    Ablation of PVC with RF energy

  • Cryo Ablation catheterDevice

    Ablation pf PVC with Cryo enerygy

Study groups in NCT03086902
Study groupRoleWhat they receive
Cryo AblationExperimentalPVCs will be mapped and ablated with a Cryo Ablation catheter
Receives: Device: Cryo Ablation catheter
Radiofrequency AblationActive comparatorIn this arm PVCs will be mapped and ablated with a Radiofrequency Ablation catheter
Receives: Device: Radiofrequency Ablation Catheter

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. Comparison of successful catheter ablation between both methods.

    Successful ablation will be defined as absence of clinical VA or > 50% reduction in arrhythmia burden on Holter in the absence of anti-arrhythmic medication.

    Measured: During procedure and 1 month follow up

Secondary outcomes (2)
  1. Comparison of complications such as pericardial effusion/ tamponade, coronary artery damage and post procedure pericardial pain requiring medical management.

    Any complication will be assessed clinically during procedure and managed as indicated.

    Measured: During Procedure

  2. Comparison of procedure and fluoroscopy time between both strategies

    Time of procedure and fluoroscopy will be logged into CRF

    Measured: During Procedure

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted22 Mar 2017
  2. Study startDec 2018 (estimated)
  3. Primary completionJul 2020 (estimated)
  4. Study completionJul 2021 (estimated)

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Interventional
Phase
Phase N/A
Primary purpose
Treatment
Allocation
Randomised
Intervention model
Parallel groups
Model description
Group sample sizes of 44 in Group 1 and 44 in Group 2 achieve 80% power to detect a difference between the group proportions of -0.2000. The proportion in Group 1 (the treatment group) is assumed to be 0.2500 under the null hypothesis and 0.0500 under the alternative hypothesis. The proportion in Group 2 (the control group) is 0.2500. The test statistic used is the two-sided Z test with pooled variance. The significance level of the test was targeted at 0.0500. The significance level actually achieved by this design is 0.0531.
Masking
None (open label)
Enrolment
88 participants (estimated)
IDs, dates and publications
ClinicalTrials.gov ID
NCT03086902
Sponsor's protocol ID
SMC-3991-17
Acronym
PVC
Status last verified
Jun 2018
First submitted
16 Mar 2017
Last updated
6 Jun 2018
Results posted
No
Data monitoring committee
No
FDA-regulated drug
No
FDA-regulated device
Yes
Individual data sharing
Undecided: All data will be kept at SMC and will be available

Publications

  • Kurzidim K, Schneider HJ, Kuniss M, Sperzel J, Greiss H, Berkowitsch A, Pitschner HF. Cryocatheter ablation of right ventricular outflow tract tachycardia. J Cardiovasc Electrophysiol. 2005 Apr;16(4):366-9. doi: 10.1046/j.1540-8167.2005.40571.x.

    PubMed 15828876
  • Santangeli P, Proietti R, Di Biase L, Bai R, Natale A. Cryoablation versus radiofrequency ablation of atrioventricular nodal reentrant tachycardia. J Interv Card Electrophysiol. 2014 Mar;39(2):111-9. doi: 10.1007/s10840-013-9842-2. Epub 2013 Nov 29.

    PubMed 24293174
  • McDonnell K, Rhee E, Srivathsan K, Su W. Novel utility of cryoablation for ventricular arrhythmias arising from the left aortic cusp near the left main coronary artery: a case series. Heart Rhythm. 2014 Jan;11(1):34-8. doi: 10.1016/j.hrthm.2013.10.008. Epub 2013 Oct 3.

    PubMed 24096170
  • Chung FP, Chong E, Lin YJ, Chang SL, Lo LW, Hu YF, Tuan TC, Chao TF, Liao JN, Huang YC, Chi PC, Chan CS, Chen YY, Huang HK, Chen SA. Different characteristics and electrophysiological properties between early and late recurrences after acute successful catheter ablation of idiopathic right ventricular outflow tract arrhythmias during long-term follow-up. Heart Rhythm. 2014 Oct;11(10):1760-9. doi: 10.1016/j.hrthm.2014.06.011. Epub 2014 Jun 12.

    PubMed 24931638
  • Rivera S, Ricapito Mde L, Tomas L, Parodi J, Bardera Molina G, Banega R, Bueti P, Orosco A, Reinoso M, Caro M, Belardi D, Albina G, Giniger A, Scazzuso F. Results of Cryoenergy and Radiofrequency-Based Catheter Ablation for Treating Ventricular Arrhythmias Arising From the Papillary Muscles of the Left Ventricle, Guided by Intracardiac Echocardiography and Image Integration. Circ Arrhythm Electrophysiol. 2016 Apr;9(4):e003874. doi: 10.1161/CIRCEP.115.003874.

    PubMed 27069089

Questions about this trial

What is this clinical trial studying?

A study testing Radiofrequency Ablation Catheter and Cryo Ablation catheter in people with Premature Ventricular Contraction, run by Sheba Medical Center.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 2 inclusion and 5 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: status not confirmed, as of the sponsor's last update on 6 Jun 2018. Status can change between updates, so confirm with the study contact before making plans.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

Results are not available in the source record.

How can a doctor refer a patient or contact the research team?

Contact Eyal Nof, MD (+9725302604, eyal.nof@sheba.health.gov.il), or a site near the patient. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

Comparison of successful catheter ablation between both methods. (time frame: During procedure and 1 month follow up). It is what the study was designed to measure, not a finding.

Where can I read the original study information?

On the ClinicalTrials.gov record for NCT03086902, which also lists 5 linked publications.

Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 6 Jun 2018.

Free account

Keep searching with a free account

You’ve used your 3 free searches for this session. Log in or create a free AzTrials account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in