Heart Failure, Left-SidedECOH3NCT03087669

Central and Cerebral Circulation in Early Stages After LVAD Implantation

A study testing LVAD flow velocity setting-Rounds per Minute(RPM) on HeartMate III® and MAP intervention using Noradrenalin in people with Heart Failure, Left-Sided and Heart Failure, Right-Sided, run by Sahlgrenska University Hospital at 1 site in Sweden.

Unknown status

Status not confirmed. The sponsor has not verified this record for over two years, so it may be out of date.

Official record
Search all trials

Trial summary

This trial will evaluate patients with a mechanical Left Ventricular Assist Device (LVAD) in early stages after surgical implantation. Within the first 2 days of postoperative ICU care, 20 patients will firstly be exposed to 4 different LVAD pump flow settings with a stable blood pressure. Read more about this study

Who is it for?
Any age
What is being tested?
LVAD flow velocity setting-Rounds per Minute(RPM) on HeartMate III® and MAP intervention using Noradrenalin
Type of treatment
Medical device
Could I receive a placebo?
No, everyone receives an active treatment
How many people
20 participants
Where
1 siteSweden
Study dates
16 Feb 2017to 1 Mar 2020
Phase
Interventional
Are there results?
None posted in the registry

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages Any age
  • All sexes
  • No healthy volunteers
  • Child, Adult, Older adult

Who may be able to join

  • All patients receiving LVAD of the type HeartMate3® at Sahlgrenska University hospital

Who cannot join

  • Perioperative need for an RVAD first 3 days postoperatively after an LVAD implantation

Trial locations and contacts

1 site in 1 country.

Bengt Redfors, MD.PhD contact

0046313427445

bengt.redfors@vgregion.se

Bjorn Reinsfelt, MD.PhD contact

0046313428183

bjorn.reinsfelt@gu.se

Sweden1 site, 1 recruiting
  • Sahlgrenska University Hospital. Department of Cardiothoracic Anaesthesia & Intensive Care

    Gothenburg, 41345

    Bjorn Reinsfelt, PhD, 0046313428183, bjorn.reinsfelt@gu.se

    Bengt Redfors, PhD, 0046313427445, bengt.redfors@vgregion.se

    Recruiting

Other trials in Sweden

About this study

Official title: Evaluation of Central and Cerebral Circulation in Early Stages After Implantation of Left Ventricular Assist Device (LVAD)

This trial will evaluate patients with a mechanical Left Ventricular Assist Device (LVAD) in early stages after surgical implantation. Within the first 2 days of postoperative ICU care, 20 patients will firstly be exposed to 4 different LVAD pump flow settings with a stable blood pressure. A second intervention will be mean arterial blood pressure (MAP) adjustments to 4 preset levels (60-70-80 and 90 mmHg) with a constant preset LVAD flow. The two manipulations; 1) Constant MAP with variation of LVAD flow and 2) Constant LVAD flow with variation of MAP, will be monitored by Central hemodynamic parameters, echocardiographic parameters and cerebral blood flow velocity (CBFV) parameters. The purpose of the trial is to find the optimal combination of LVAD pump flow, mean arterial pressure and right heart ventricle function for each patient. And at the same time describe the effect of flow and pressure variations on CBFV.

Read the detailed description

Patients with severe left ventricular heart failure and estimated short expected survival time despite optimal medical therapy can be treated with a left ventricular mechanical heart pump - described as a Left Ventricular Assist Device (LVAD). The LVAD can be used as a bridge for patient survival prior to heart transplantation, or as a destination therapy for terminal heart failure. The LVAD delivers a non-pulsatile blood flow into the patients aorta, supporting and/or taking over the left ventricular function. However the right heart ventricle (RV) is not supported by the LVAD. RV failure is a major threat to the patient, in particular during the early postoperative period. Postoperative RV failure after LVAD implantation is medically treated, but in severe cases a mechanical temporary right ventricular assist (RVAD) may be needed. Patients in need of postoperative RVAD after an LVAD implant have a significantly increased mortality. Thus it is of vital importance to balance the LVAD pump flow against the native RV function in order to avoid the need for an RVAD. If the LVAD flow rate is set too low the RV will be exposed to a high afterload and risk failure. If, on the other hand, the LVAD flow is set too high it can potentially completely empty the left ventricle with secondary geometrical distortion of the heart chambers and an increased venous return to the RV. This too increases the risk for RV failure. To find the optimal LVAD flow rate it is custom to do an extensive evaluation of central hemodynamic parameters (Cardiac Output(CO), Pulmonary Capillary Wedge Pressure (PCWP), Pulmonary Arterial Pressure (PAP), Central Venous Pressure (CVP)) and cardiac echocardiographic evaluation of RV function at different LVAD pump flow rates and MAP. The instant balance between RV filling pressure-CVP, and LV filling pressure-PCWP, is on the other hand easy to obtain. However it is not known if these measurements can be used to obtain an optimal LVAD flow rate. Furthermore all mechanically driven circulatory support devices, including LVAD, will expose the peripheral arterial circulation to a non-pulsatile blood flow.There are few previous reports on how an LVAD affects the cerebral blood flow autoregulation and microembolic load at different settings and MAP. This investigation aims to describe these cerebral effect af an LVAD using a continous Transcranial Doppler (TCD) detection of cerebral arteries.

Being tested
LVAD flow velocity setting-Rounds per Minute(RPM) on HeartMate III®, MAP intervention using Noradrenalin
Keywords
Left Ventricular Assist Device, Hemodynamic monitoring
Medical subject headings
Heart Failure

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • LVAD flow velocity setting-Rounds per Minute(RPM) on HeartMate III®Device

    Also called RPM setting

    Increase in LVAD RPM setting induces an actual increase in LVAD outflow to the patient.This gives the patient an increased systemic Cardiac Output(CO)

  • MAP intervention using NoradrenalinDrug

    Also called MAP setting

    At a fixed RPM rate for the LVAD the Mean Arterial Pressure (MAP) is increased to preset levels of 60-70-80-90 mmHG using Noradrenalin

Study groups in NCT03087669
Study groupRoleWhat they receive
Observation of hemodynamic parametersExperimentalLVAD flow velocity setting-Rounds Per Minute(RPM) intervention: Change of LVAD RPM while observing Central hemodynamic, echocardiographic and CBFV effects. MAP intervention: Stepwise Change of MAP from 60-70-80 to 90 mmHg with a fixed set of LVAD RPM. After a 5 minute steady state for each level of MAP, the observations of central hemodynamics, echocardiographic measures and CBFV measurements will be repeated.
Receives: Device: LVAD flow velocity setting-Rounds per Minute(RPM) on HeartMate III®; Drug: MAP intervention using Noradrenalin

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. Changes PCWP/CVP ratio

    The change in PCWP (mmHg)/CVP (mmHg) ratio at different levels of LVAD flow as a marker for the optimal balance between LVAD flow and RV function

    Measured: Change from baseline at different settings of LVAD RPM within 10 minutes for each level

Secondary outcomes (4)
  1. CO

    Cardiac Output in litres/minute

    Measured: Change from baseline at different settings of LVAD RPM within 10 minutes for each level

  2. LVAD Velocity Time Integral

    LVAD Velocity Time Integral in centimeters(cm)

    Measured: Change from baseline at different settings of LVAD RPM within 10 minutes for each level

  3. Right Ventricle Outflow Tract (RVOT) Velocity Time Integral (VTI)

    RVOT Velocity Time Integral in centimeters(cm)

    Measured: Change from baseline at different settings of LVAD RPM within 10 minutes for each level

  4. CBFV

    CBFV in cm/second

    Measured: Change from baseline at different settings of LVAD RPM within 10 minutes for each level

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted22 Mar 2017
  2. Study start16 Feb 2017
  3. Primary completion1 Mar 2020 (estimated)
  4. Study completion1 Mar 2020 (estimated)

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Interventional
Phase
Phase N/A
Primary purpose
Treatment
Allocation
Not applicable
Intervention model
Single group
Model description
1. LVAD will have a setting of 4800 rounds per minute (RPM). Hemodynamic, echocardiographic and cerebral blood flow measurements will be performed: CO, PCWP, CVP, PAP, MAP, Peripheral and central hemoglobine oxygen saturation (SaO2 and SvO2), Heart Rate (HR), RV outflow tract Velocity Time Integral (RVOT VTI), RV and LV diameter, VTI of LVAD outflow. CBFV of right and left medial cerebral artery (RMCA and LMCA) 2. The above mentioned measurements will be repeated with LVAD settings of 5200 RPM, 5600 RPM, and 6000 RPM. 3. With the LVAD fixed to an optimized setting detected by the previous interventions, the blood pressure will be adjusted to MAP 60 mmHg. The above mentioned measurements will be repeated. 4. Using Noradrenaline the MAP will be adjusted to 70mmHg, 80 mmHg and 90 mmHg. At steady state for each level of MAP with a fixed LVAD flow, all the above mentioned measurements will be repeatedly performed.
Masking
None (open label)
Enrolment
20 participants (estimated)
IDs, dates and publications
ClinicalTrials.gov ID
NCT03087669
Sponsor's protocol ID
ECOH 3
Acronym
ECOH3
Status last verified
Mar 2017
First submitted
28 Feb 2017
Last updated
22 Mar 2017
Results posted
No
Data monitoring committee
No
FDA-regulated drug
No
FDA-regulated device
No
Individual data sharing
No

Publications

  • Uriel N, Adatya S, Maly J, Kruse E, Rodgers D, Heatley G, Herman A, Sood P, Berliner D, Bauersachs J, Haverich A, Zelizko M, Schmitto JD, Netuka I. Clinical hemodynamic evaluation of patients implanted with a fully magnetically levitated left ventricular assist device (HeartMate 3). J Heart Lung Transplant. 2017 Jan;36(1):28-35. doi: 10.1016/j.healun.2016.07.008. Epub 2016 Jul 17.

    PubMed 27773456
  • Uriel N, Sayer G, Addetia K, Fedson S, Kim GH, Rodgers D, Kruse E, Collins K, Adatya S, Sarswat N, Jorde UP, Juricek C, Ota T, Jeevanandam V, Burkhoff D, Lang RM. Hemodynamic Ramp Tests in Patients With Left Ventricular Assist Devices. JACC Heart Fail. 2016 Mar;4(3):208-17. doi: 10.1016/j.jchf.2015.10.001. Epub 2015 Dec 30.

    PubMed 26746378
  • Ono M, Joshi B, Brady K, Easley RB, Kibler K, Conte J, Shah A, Russell SD, Hogue CW. Cerebral blood flow autoregulation is preserved after continuous-flow left ventricular assist device implantation. J Cardiothorac Vasc Anesth. 2012 Dec;26(6):1022-8. doi: 10.1053/j.jvca.2012.07.014.

    PubMed 23122299

Questions about this trial

What is this clinical trial studying?

A study testing LVAD flow velocity setting-Rounds per Minute(RPM) on HeartMate III® and MAP intervention using Noradrenalin in people with Heart Failure, Left-Sided and Heart Failure, Right-Sided, run by Sahlgrenska University Hospital at 1 site in Sweden.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 1 inclusion and 1 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: status not confirmed, as of the sponsor's last update on 22 Mar 2017. Status can change between updates, so confirm with the study contact before making plans.

Where is the study taking place?

The record lists 1 site in Sweden. Whether a site is taking part right now should be confirmed with that site. See every site.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

Results are not available in the source record.

How can a doctor refer a patient or contact the research team?

Contact Bengt Redfors, MD.PhD (0046313427445, bengt.redfors@vgregion.se), or a site near the patient. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

Changes PCWP/CVP ratio (time frame: Change from baseline at different settings of LVAD RPM within 10 minutes for each level). It is what the study was designed to measure, not a finding.

Where can I read the original study information?

On the ClinicalTrials.gov record for NCT03087669, which also lists 3 linked publications.

Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 22 Mar 2017.

Free account

Log in to keep searching

You’ve used your 3 free searches. AzTrials is free: log in or create a free account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in