AzTrials
AzTrials

Airway ManagementNCT03109678

A Comparison of the Intubating Laryngeal Mask FASTRACH™ and the Intubating Laryngeal Mask Ambu Aura-i™

A study testing Crossover Ambu Aura-i™ / Rüsch Super Safety Silk™, Crossover Ambu Aura-i™ / LMA ETT™ and Crossover FASTRACH™ / Rüsch Super Safety Silk™ in people with Airway Management and Laryngeal Mask Airway, run by Asklepios Kliniken Hamburg GmbH.

Completed

Finished. The study has ended and is not enrolling. Results may be posted on the official record.

Official record
Search all trials

Trial summary

The intubating laryngeal mask Fastrach™ is considered a gold standard for blind intubation as well as for fibreoptic guided intubation via a laryngeal mask. Recently, a single use version of the mask has been introduced. Read more about this study

Who is it for?
Ages 15 to 80 years
What is being tested?
Crossover Ambu Aura-i™ / Rüsch Super Safety Silk™, Crossover Ambu Aura-i™ / LMA ETT™ and Crossover FASTRACH™ / Rüsch Super Safety Silk™
Type of treatment
Medical device
Could I receive a placebo?
No, everyone receives an active treatment
How many people
80 participants
Where
No sites listed yet
Study dates
12 Jul 2011to 7 Mar 2012
Phase
Interventional
Are there results?
None posted in the registry

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 15 to 80 years
  • All sexes
  • No healthy volunteers
  • Child, Adult, Older adult

Who may be able to join

  • patients undergoing planned general anaesthesia
  • planned tracheal intubation
  • elective surgical procedure
  • 15 to 80 years of age

Who cannot join

  • ASA physical status IV and V
  • severe pulmonary comorbidity (COPD GOLD >III, bronchial asthma)
  • indication for rapid-sequence induction
  • mouth opening (interincisor distance) <3cm
  • morbid obesity (BMI >35kg.m-2)

About this study

The intubating laryngeal mask Fastrach™ is considered a gold standard for blind intubation as well as for fibreoptic guided intubation via a laryngeal mask. Recently, a single use version of the mask has been introduced. The Fastrach single use laryngeal mask is beng compared to the new, low-priced single use intubating laryngeal mask Ambu Aura-i™.

Read the detailed description

Eighty patients undergoing general anaesthesia with planned tracheal intubation for elective surgical procedures are enrolled in the study after checking for inclusion and exclusion criteria. Patients are randomised to either LMA group for blind tracheal intubation with either a standard PVC tracheal tube, or a specifically for the LMA Fastrach developed tube, yielding 4 subgroups.

After a standardised anaesthesia induction, blind intubation is performed in each study group. Different time intervals are documented, such as time to first adequate lung ventilation, or f.e. time for laryngeal mask placement. A crossover-design is performed after unsuccessful intubation, using the alternate LMA or the other tracheal tube. LMA placement is visualised by fibreoptic control.

An estimated success rate for blind intubation of 60% in the Aura-i group versus 90% in the Fastrach group yields a sample size of n= 38. To compensate for dropouts, n=40 subjects are enrolled in each group.

Being tested
Crossover Ambu Aura-i™ / Rüsch Super Safety Silk™, Crossover Ambu Aura-i™ / LMA ETT™, Crossover FASTRACH™ / Rüsch Super Safety Silk™, Crossover FASTRACH™ / LMA ETT™

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • Crossover Ambu Aura-i™ / Rüsch Super Safety Silk™Device

    After unsuccessful blind intubation in the Ambu Aura-i™ / Rüsch Super Safety Silk™ group: crossover design using the Ambu Aura-i™ mask in combination with the LMA ETT™ tracheal tube

  • Crossover Ambu Aura-i™ / LMA ETT™Device

    After unsuccessful blind intubation in the Ambu Aura-i™ / LMA ETT group: crossover design using the Ambu Aura-i™ mask in combination with the Rüsch Super Safety Silk™ tracheal tube

  • Crossover FASTRACH™ / Rüsch Super Safety Silk™Device

    After unsuccessful blind intubation in the FASTRACH™ / Rüsch Super Safety Silk™ group: crossover design using the FASTRACH™ mask in combination with the LMA ETT™ tube

  • Crossover FASTRACH™ / LMA ETT™Device

    After unsuccessful blind intubation in the FASTRACH™ / LMA ETT™ group: crossover design using the FASTRACH™ mask in combination with the Rüsch Super Safety Silk™ tube

Study groups in NCT03109678
Study groupRoleWhat they receive
Aura-i / RüschExperimentalBlind tracheal intubation: Combination of laryngeal mask Ambu Aura-i™ with Rüsch Super Safety Silk™ tracheal tube
Receives: Device: Crossover Ambu Aura-i™ / Rüsch Super Safety Silk™
Aura-i / LMA ETTExperimentalBlind tracheal intubation: Combination of laryngeal mask Ambu Aura-i™ with LMA ETT™ tracheal tube
Receives: Device: Crossover Ambu Aura-i™ / LMA ETT™
Fastrach / RüschExperimentalBlind tracheal intubation: Combination of laryngeal mask Fastrach™ with Rüsch Super Safety Silk™ tracheal tube
Receives: Device: Crossover FASTRACH™ / Rüsch Super Safety Silk™
Fastrach / LMA ETTExperimentalBlind tracheal intubation: Combination of laryngeal mask Fastrach™ with LMA ETT™ tracheal tube
Receives: Device: Crossover FASTRACH™ / LMA ETT™

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. success rate of blind intubation

    overall success rate of blind tracheal intubation within two attempts using either the FASTRACH™ laryngeal mask or the Ambu Aura-i™ laryngeal mask

    Measured: through study completion; time frame for individual study patient: two attempts of blind tracheal intubation peri-interventional, time maximum of 300 seconds

Secondary outcomes (5)
  1. influence of tracheal tubes

    influence of success rates of blind tracheal intubation using different tracheal tubes (Rüsch or LMA-ETT)

    Measured: through study completion; time frame for individual study patient: two attempts of blind tracheal intubation peri-interventional, time maximum of 300 seconds

  2. equivalence of the laryngeal masks regarding fibreoptic visualisation

    fibreoptic control of laryngeal mask placement (Fastrach and Aura-i); the position of the larynx relative to the laryngeal cuff and mask-aperture is visualised and categorised as "correct", "lateral deviation", "epiglottic downfolding" or "not assessable"; additionally, the view on the larynx comparable to Cormack/Lehane score is recorded

    Measured: through study completion; after placing the laryngeal mask and checking for airway leak pressure, fibreoptic visualisation is performed within 60 seconds

  3. subjective handling score

    subjective handling score for the two compared laryngeal masks, rated as excellent (1) - poor (4)

    Measured: through study completion; the handling of the laryngeal masks during the first placement attempt within 60 seconds; directly after placing laryngeal masks and before fibreoptic visualisation, the subjective handling score is documented as above

  4. differences in airway leak pressure

    differences in airway leak pressure (ALP) of the two compared laryngeal masks, in cm H2O; presence of audible leakage as well as the absence of corresponding pressure increase on the monitor recorded by setting the APL valve to 40cm H2O, and fresh gas flow at 3l/min

    Measured: through study completion; right after placing the laryngeal mask and checking for correct positioning, ALP is documented within 60 seconds

  5. incidence of postoperative sore throat and hoarseness

    incidence of postoperative sore throat and hoarseness as well as difficulty swallowing as reported by the study patients ("none", "moderate", "severe")

    Measured: patient interview 24 hours post procedural

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted12 Apr 2017
  2. Study start12 Jul 2011
  3. Primary completion7 Mar 2012
  4. Study completion7 Mar 2012

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Interventional
Phase
Phase N/A
Primary purpose
Device feasibility
Allocation
Randomised
Intervention model
Crossover
Masking
None (open label)
Enrolment
80 participants (actual)
IDs, dates and publications
ClinicalTrials.gov ID
NCT03109678
Sponsor's protocol ID
AZ 107/02
Status last verified
Apr 2017
First submitted
8 Mar 2017
Last updated
12 Apr 2017
Results posted
No
Data monitoring committee
No
FDA-regulated drug
No
FDA-regulated device
No
Individual data sharing
No

Publications

  • Schiewe R, Stoeck M, Gruenewald M, Hoecker J, Bein B. A comparison of blind intubation with the intubating laryngeal mask FASTRACH and the intubating laryngeal mask Ambu Aura-i a prospective randomised clinical trial. BMC Anesthesiol. 2019 Mar 30;19(1):44. doi: 10.1186/s12871-019-0718-6.

    PubMed 30927922

Questions about this trial

What is this clinical trial studying?

A study testing Crossover Ambu Aura-i™ / Rüsch Super Safety Silk™, Crossover Ambu Aura-i™ / LMA ETT™ and Crossover FASTRACH™ / Rüsch Super Safety Silk™ in people with Airway Management and Laryngeal Mask Airway, run by Asklepios Kliniken Hamburg GmbH.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 4 inclusion and 5 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: finished, as of the sponsor's last update on 12 Apr 2017. Status can change between updates, so confirm with the study contact before making plans.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.

How can a doctor refer a patient or contact the research team?

The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

success rate of blind intubation (time frame: through study completion; time frame for individual study patient: two attempts of blind tracheal intubation peri-interventional, time maximum of 300 seconds). It is what the study was designed to measure, not a finding.

Where can I read the original study information?

On the ClinicalTrials.gov record for NCT03109678, which also lists 1 linked publication.

Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 12 Apr 2017.

Free account

Log in to keep searching

You’ve used your 3 free searches. AzTrials is free: log in or create a free account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in