AzTrials
AzTrials

MyopiaNCT03111160

Lower Femtosecond Laser Energy Levels Lead to Better Visual Recovery After Small-incision Lenticule Extraction for Myopia

A study testing SMILE procedure using lower energy (100, 105, and 110 nJ) and SMILE procedure using conventional energy (115 to 150 nJ) in people with Myopia, run by Yonsei University at 1 site in South Korea.

Completed

Finished. The study has ended and is not enrolling. Results may be posted on the official record.

Official record
Search all trials

Trial summary

Small-incision lenticule extraction (SMILE), the most recently developed refractive surgical technique, is being performed in a growing number of cases. This intrastromal keratomileusis using only a femtosecond laser is a new procedure that extracts the refractive lenticule through a small corneal incision ranging… Read more about this study

Who is it for?
Ages 20 to 40 years
Conditions the study is for
Myopia
What is being tested?
SMILE procedure using lower energy (100, 105, and 110 nJ) and SMILE procedure using conventional energy (115 to 150 nJ)
Type of treatment
Surgery or procedure
Could I receive a placebo?
No, everyone receives an active treatment
How many people
150 participants
Where
1 siteSouth Korea
Study dates
16 Nov 2016to 15 Jan 2017
Phase
Interventional
Are there results?
None posted in the registry

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 20 to 40 years
  • All sexes
  • No healthy volunteers
  • Adult

Who may be able to join

  • age of 20 years or older.
  • corneal thickness of more than 500 μm
  • manifest refractive sphere of -3.00 to -6.00 diopters (D)
  • manifest refractive cylinder less than 6.00 D
  • stable refractive error with less than a 0.50 D change in sphere and cylinder in the previous year
  • corrected distance visual acuity (CDVA) of 20/20 or better in both eyes

Who cannot join

  • severe ocular surface disease
  • any corneal disease, cataract, glaucoma, macular disease, or previous history of intraocular or corneal surgery
  • Patients with suspicion of keratoconus on corneal topography

Trial locations and contacts

1 site in 1 country.

South Korea1 site
  • Department of Ophthalmology, Yonsei Univeristy College of Medicine

    Seoul, Seoul, 03722

Other trials in South Korea

About this study

Small-incision lenticule extraction (SMILE), the most recently developed refractive surgical technique, is being performed in a growing number of cases. This intrastromal keratomileusis using only a femtosecond laser is a new procedure that extracts the refractive lenticule through a small corneal incision ranging from 2 to 5 mm, with the absence of a flap and the preservation of the anterior-most stromal lamellae and Bowman's layer (except for the region of the small incision). Many studies have demonstrated that SMILE achieved comparable or superior efficacy, safety, and predictability to femtosecond laser -assisted in situ keratomileusis (FS-LASIK) and femtosecond lenticule extraction (FLEx). However, the recovery of visual acuity in the early postoperative period after SMILE is slower, compared to other refractive surgery techniques. Therefore, adjusting energy might improve postoperative visual acuity and recovery time after SMILE. Nevertheless, the optimal parameters drawn from a well-organized randomized study have yet to be elucidated. The purpose of this study was to investigate the optimal femtosecond laser energy, with the aim of improving clinical outcomes during the early postoperative period after SMILE for the correction of myopia. To this end, we used a 500 kHz VisuMax with spot-spacing control at energy levels lower than 115 nJ, based on the previous studies. Therefore, we prospectively compared visual outcomes of two groups randomly divided by different laser energies: one underwent SMILE using lower energy levels of 100, 105, and 110 nJ (L-SMILE), while the other group underwent SMILE at energy levels conventionally used of 115 to 150 nJ (C-SMILE).

Read the detailed description

This prospective randomized comparative study was approved by the Institutional Review Board, Yonsei University College of Medicine, Seoul, South Korea (IRB No. 4-2016-0840). The study adhered to the tenets of the Declaration of Helsinki and followed good clinical practices. All patients provided informed consent after a detailed explanation of the possible risks and benefits of the study. The right eye of each patient was included in the study unless contraindicated, in which case the left eye was used. The patients were randomized to one of two groups (L-SMILE or C-SMILE) by means of permuted block-randomization with the Clinstat software (Available from: http://www-users.york.ac.uk/~mb55/soft/soft.htm). Thereafter, the patients were randomly allocated a laser energy level within their SMILE group by means of minimization with the Minim software (Available from: http://www.users.york.ac.uk/~mb55/guide/minim.htm) due to the small sample size (< 200).

Patients were recruited from November 2016 to December 2017. All patients underwent a baseline preoperative assessment including anterior and posterior segment examinations. Inclusion criteria were: corneal thickness of more than 500 μm, manifest refractive sphere of -3.00 to -6.00 diopters (D), manifest refractive cylinder less than 6.00 D, stable refractive error with less than a 0.50 D change in sphere and cylinder in the previous year, corrected distance visual acuity (CDVA) of 20/20 or better in both eyes, and age of 20 years or older. Exclusion criteria were: severe ocular surface disease, any corneal disease, cataract, glaucoma, macular disease, or previous history of intraocular or corneal surgery. Patients with suspicion of keratoconus on corneal topography were also excluded.

We reviewed thoroughly literatures which included 239 online-available papers about SMILE, and, of them, we selected 116 original articles on clinical outcome or studies involving human lenticules after SMILE surgery and identified all the energy levels used in each article, as possible. Finally, we found almost all previous researches provided surgical results by using a 200 or 500 kHz VisuMax (Carl Zeiss Meditec AG, Jena, Germany) with energy levels of 115 to 190 nJ except only three studies: two studies by same researchers obscured the laser energy level (approximately 110 nJ) used in SMILE, however the other latest study provided definitely their laser energy 100 nJ (Figure 1 and supplemental table 1). There were 5 studies on SMILE using 115 nJ of laser energy in the literature.

Based on the review of literature, we regarded SMILE using energy levels of 115 nJ or higher as 'conventional' energy-SMILE (C-SMILE). Since 500kHz VisuMax femtosecond laser used in this study had a threshold photodisruption energy level of 100 nJ, lowest energy level of L-SMILE was set at 100 nJ. Because the spot distance must be changed by approximately 1 μm when laser energy changed by 50 nJ, we could set the maximum laser energy to 150 (100 + 50) nJ as highest one of C-SMILE while keeping the spot distance constant. Finally, we established two groups divided by different laser energies: L-SMILE group using lower energy levels of 100, 105, and 110 nJ, and C-SMILE group using 'conventional', not higher, energy levels of 115 to 150 nJ.

Based on our preliminary results (n=6 per group) showing the significant mean difference of postoperative visual acuity between C-SMILE and L-SMILE, a priori power analysis was performed. Group sample sizes of 54 and 81 achieved 81% power to detect a difference of - 0.1 between the null hypothesis that both group means are 0.0 and the alternative hypothesis that the mean of group 2 is 0.1 with estimated group standard deviations of 0.1 and 0.1 and with a significance level (alpha) of 0.05 using a two-sided two-sample t-test. Therefore, we confirmed that sample size of L-SMILE is 60 and one of C-SMILE is 90 as considering 10 % reduction.

Conditions
Myopia
Being tested
SMILE procedure using lower energy (100, 105, and 110 nJ), SMILE procedure using conventional energy (115 to 150 nJ)
Keywords
Small-incision lenticule extraction, femtosecond laser, lower laser energy level, early visual recovery
Medical subject headings
Myopia

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • SMILE procedure using lower energy (100, 105, and 110 nJ)Procedure or surgery

    Based on the review of literature, we regarded SMILE using energy levels of 115 nJ or higher as 'conventional' energy-SMILE (C-SMILE). Since 500kHz VisuMax femtosecond laser used in this study had a threshold photodisruption energy level of 100 nJ, lowest energy level of L-SMILE was set at 100 nJ. Because the spot distance must be changed by approximately 1 μm when laser energy changed by 50 nJ, we could set the maximum laser energy to 150 (100 + 50) nJ as highest one of C-SMILE while keeping the spot distance constant. Finally, we established two groups divided by different laser energies: L-SMILE group using lower energy levels of 100, 105, and 110 nJ, and C-SMILE group using 'conventional', not higher, energy levels of 115 to 150 nJ.

  • SMILE procedure using conventional energy (115 to 150 nJ)Procedure or surgery

    The SMILE procedures were conducted in the Eyereum Eye Clinic (Seoul, South Korea). The target postoperative refraction was emmetropia. The surgery, using standardized techniques, was performed by an experienced surgeon (D.S.Y.K.) using the VisuMax system. The surgical parameters used during SMILE were as follows: repetition rate of 500 kHz, pulse energy 100 to 150 nJ (100, 105, and 110 nJ, L-SMILE; 115 to 150 nJ, C-SMILE), spot distance 4.5 μm (regardless of FSL energy), cap thickness 120 μm, and side-cut width 2 mm in the 12-o'clock position with an angle of 90°. After the anterior (upper) and posterior (lower) delineated plane of the intrastromal lenticule were well defined, the anterior and posterior interface were dissected with a micro-spatula with a blunt circular tip and extracted with micro-forceps. The integrity of the lenticule was also checked subsequently.

Study groups in NCT03111160
Study groupRoleWhat they receive
lower energyExperimentalSMILE procedure using lower energy (100, 105, and 110 nJ)
Receives: Procedure: SMILE procedure using lower energy (100, 105, and 110 nJ)
conventional energy (115 to 150 nJ)Active comparatorSMILE procedure using conventional energy (115 to 150 nJ)
Receives: Procedure: SMILE procedure using conventional energy (115 to 150 nJ)

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. Uncorrected Distance Vision Acuity

    Uncorrected Distance Vision Acuity bya Snellen visual acuity chart

    Measured: within the first 90 days after surgery

  2. Corneal aberration

    Corneal aberration automatically recoreded by a wavefront analysis machine

    Measured: within the first 90 days after surgery

Secondary outcomes (1)
  1. surface roughness of lenticules

    By atomic force microscopy, the average roughness (Ra, µm), root-mean-square roughness (Rq, µm), and ten-point mean height roughness (Rz, µm) are automatically recorded on the height images.

    Measured: immediately after SMILE surgery

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted12 Apr 2017
  2. Study start16 Nov 2016
  3. Primary completion15 Jan 2017
  4. Study completion15 Jan 2017

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Interventional
Phase
Phase N/A
Primary purpose
Treatment
Allocation
Randomised
Intervention model
Parallel groups
Model description
Based on the review of literature, we regarded SMILE using energy levels of 115 nJ or higher as 'conventional' energy-SMILE (C-SMILE). Since 500kHz VisuMax femtosecond laser used in this study had a threshold photodisruption energy level of 100 nJ, lowest energy level of L-SMILE was set at 100 nJ. Because the spot distance must be changed by approximately 1 μm when laser energy changed by 50 nJ, we could set the maximum laser energy to 150 (100 + 50) nJ as highest one of C-SMILE while keeping the spot distance constant. Finally, we established two groups divided by different laser energies: L-SMILE group using lower energy levels of 100, 105, and 110 nJ, and C-SMILE group using 'conventional', not higher, energy levels of 115 to 150 nJ.
Masking
None (open label)
Enrolment
150 participants (actual)
IDs, dates and publications
ClinicalTrials.gov ID
NCT03111160
Sponsor's protocol ID
4-2016-0840
Status last verified
Apr 2017
First submitted
26 Mar 2017
Last updated
12 Apr 2017
Results posted
No
Data monitoring committee
No
FDA-regulated drug
No
FDA-regulated device
No
Individual data sharing
No

Publications

  • Reinstein DZ, Archer TJ, Gobbe M. Small incision lenticule extraction (SMILE) history, fundamentals of a new refractive surgery technique and clinical outcomes. Eye Vis (Lond). 2014 Oct 16;1:3. doi: 10.1186/s40662-014-0003-1. eCollection 2014.

    PubMed 26605350
  • Wang JS, Xie HT, Jia Y, Zhang MC. Small-incision lenticule extraction versus femtosecond lenticule extraction for myopic: a systematic review and Meta-analysis. Int J Ophthalmol. 2017 Jan 18;10(1):115-121. doi: 10.18240/ijo.2017.01.19. eCollection 2017.

    PubMed 28149787
  • Donate D, Thaeron R. Lower Energy Levels Improve Visual Recovery in Small Incision Lenticule Extraction (SMILE). J Refract Surg. 2016 Aug 1;32(9):636-42. doi: 10.3928/1081597X-20160602-01.

    PubMed 27598734

Questions about this trial

What is this clinical trial studying?

A study testing SMILE procedure using lower energy (100, 105, and 110 nJ) and SMILE procedure using conventional energy (115 to 150 nJ) in people with Myopia, run by Yonsei University at 1 site in South Korea.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 6 inclusion and 3 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: finished, as of the sponsor's last update on 12 Apr 2017. Status can change between updates, so confirm with the study contact before making plans.

Where is the study taking place?

The record lists 1 site in South Korea. Whether a site is taking part right now should be confirmed with that site. See every site.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.

How can a doctor refer a patient or contact the research team?

The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

Uncorrected Distance Vision Acuity (time frame: within the first 90 days after surgery). The study lists 2 primary outcomes in all. It is what the study was designed to measure, not a finding.

Where can I read the original study information?

On the ClinicalTrials.gov record for NCT03111160, which also lists 3 linked publications.

Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 12 Apr 2017.

Free account

Log in to keep searching

You’ve used your 3 free searches. AzTrials is free: log in or create a free account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in