Trial summary

The aim of this randomized study is conducted is to evaluate the performance and safety of air-Q intubating laryngeal airway as primary airway device in various short surgical procedure in children compared to Ambu® AuraGain™ Laryngeal Mask. Read more about this study

Who is it for?
Ages 1 year to 6 yearsHealthy volunteers can take part
Conditions the study is for
General Anaesthesia
What is being tested?
Ambu Aura Gain supraglottic airway and Air-Q supraglottic airway
Could I receive a placebo?
No, everyone receives an active treatment
How many people
64 participants
Where
1 siteMalaysia
Study dates
Nov 2016to 1 Jun 2018
Phase
Interventional
Are there results?
None posted in the registry

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 1 year to 6 years
  • All sexes
  • Healthy volunteers accepted
  • Child

Who may be able to join

  • Age between 1-6 years
  • Weight 10-30kg
  • American Society of Anesthesiologist (ASA) physical status class I and II
  • Any surgical procedures where supraglottic airway (SGA) management is appropriate
  • Duration of procedure within 2hours

Who cannot join

  • Active respiratory infection
  • Anticipated and known difficult airway
  • Lung disease requiring high airway pressure

Trial locations and contacts

1 site in 1 country.

Malaysia1 site
  • University of Science Malaysia Hospital

    Kubang Kerian, Kelantan, 16150

Other trials in Malaysia

About this study

Official title: Comparing the Effectiveness Between Air-Q Intubating Laryngeal Airway and Ambu® AuraGain™ Laryngeal Mask for Controlled Ventilation in Paediatric Patients: A Randomized Controlled Trial.

The aim of this randomized study is conducted is to evaluate the performance and safety of air-Q intubating laryngeal airway as primary airway device in various short surgical procedure in children compared to Ambu® AuraGain™ Laryngeal Mask. Current Supraglottic airway devices (SADs) available in are classic LMA (cLMA), proseal LMA (pLMA), supreme LMA (sLMA) and the newer is Ambu® AuraGain™laryngeal mask. As variety of newer SADs for children have emerged since their introduction in clinical practice, hope the outcomes of this study it help advancing our knowledge and acumen in selecting appropriate devices for paediatric population.

Read the detailed description

JUSTIFICATION OF STUDY

In view of no clinical data is available evaluating the clinical performance and safety of air-Q and Ambu® AuraGain™ in children, therefore this prospective and randomized study is conducted. Most of previous randomized studies in term of safety did not compare the hemodynamic stability.Hope the outcomes of this study it help advancing our knowledge and acumen in selecting devices for paediatric population.

RESEARCH HYPOTHESES

  1. There is no difference in the ease of insertion (number of attempts and time of insertion) between air-Q and Ambu® Aura Gain™.
  2. There is no difference in the oropharyngeal leak pressure (OLP) between air-Q and Ambu® Aura Gain™.
  3. There is no difference in hemodynamic changes between air-Q and Ambu® Aura Gain™.
  4. There is no difference in the incidence of complications between air-Q and Ambu® Aura Gain™.

METHODOLOGY

This is a prospective, single blinded and randomized controlled trial study will be conducted at Operation Theatre (OT), Hospital University Sains Malaysia (HUSM). involving paediatric patients scheduled for various surgical procedures within 2 hours where supraglottic airway management would be appropriate..

Sample size calculation For objective 1, sample size was calculated using power and sample size software and the data based on previous study by V.Darlong et al (Comparison of air-Q and Ambu Aura-i for controlled ventilation in infants: a randomized controlled trial). In this study, the time for successful insertion for air-Q is 16.53±1.53 and Ambu Aura-I is 14.68±2.83. Considering power of 80% and type error-I α of 5%, the sample size was required is 15 participants in each group. 10% is added for drop out sample. Therefore sample size, n 15 + (0.1x15) = 17 participants for each group.

For objective 2, sample size was calculated using power and sample size software and the data based on previous study by V.Darlong et al (Comparison of air-Q and Ambu Aura-i for controlled ventilation in infants: a randomized controlled trial). In this study, the OLP for air-Q is 20.21±4.62 and Ambu Aura-I is 16.21±5.66. Considering power of 80% and type error-I α of 5%, the sample size was required is 22 participants in each group. 10% is added for drop out sample. Therefore sample size, n 22 + (0.1x22) = 25 participants for each group.

Overall sample size is estimated using objective 2 because of larger sample size. Total sample size is 50 patients.

SAMPLING METHOD Patients are randomly assigned into 2 groups: air-Q (A) and Ambu® AuraGain™ (B) using computer-generated randomization. Sequentially-numbered sealed opaque envelopes containing group allocation as determined by computer-generated sequence, will be opened by a nurse in charge for study device preparation.

RECRUITMENT OF SUBJECT \& INFORMED CONSENT SEEKING Paediatric patients who meets the study criteria, their parents will be approached to invite patients participate in this study. Each parent will be given a thorough explanation along with copy of Patient Information Sheet. All questions that the participant's parents have, will be answered to their satisfaction before consent been obtained by signing the consent form.

The study is divided into screening, pre-operative, intra-operative and post-operative period.

  1. Screening period After obtaining approval from the Ethics committee, participants will be selected according to inclusion and exclusion criteria during preoperative assessment round. Study procedures will be explained and written consent will be obtained from the participant's parents.
  2. Pre-operative period In all participants, a eutectic mixture of local anaesthetic cream (EMLA) will be applied on both hands 30 minutes before transfer to operation theatre. No premedication will be prescribed in the morning of the surgery. All consented participants will be randomized using computer generated randomization into two groups: Group a (air-Q) and group B (Ambu Aura Gain). All demographic data including types and duration of surgery and diagnosis of procedure is recorded.
  3. Intra-operative Anaesthesia Technique In operation theatre, all of the participants will be monitored with non-invasive blood pressure (NIBP), pulse oximeter (SpO2), electrocardiogram (ECG) and capnography (EtCO2). Anesthesia is induced with sevoflurane in oxygen. The anesthesia plane is gradually deepened by increasing the inspired concentration of sevoflurane (2-8%) till the loss of eyelash reflex. An intravenous (IV) cannula is inserted and intravenous fentanyl 1mcg/kg and rocuronium 0.6mg/kg are administered. Use of neuromuscular blocking agent is to minimise the risk of reflex activation of the airway. After 3 minutes, the appropriate size (depending upon body weight) of SADs (according to the group allocated based on the sequence of computerized randomization) lubricated with water soluble lubricant (KY jelly) is inserted by the investigator by standard technique as per manufacture's recommendation. Then the cuff is inflated and intracuff pressure is then standardized to 60 cmH20 using a digital cuff pressure monitor. Data and timing are collected by independent observers. To prevent biasedness in conducting the study, the same investigator will insert the device for all participants. Haemodynamic parameters such as blood pressure (BP), heart rate (HR), oxygen saturation (SpO2) and end tidal carbon dioxide (EtCO2) is recorded at different interval namely, pre induction, post induction, post insertion, every 2 minutes for 10 minutes and then 5 minutes thereafter until extubation. Anesthesia is maintained with sevoflurane (Minimum Alveolar Concentration value of 1.0-1.2) in Oxygen: Air mixture of 50% . Pressure controlled ventilation is set and targeting the minute ventilation to achieve normocarbia (EtCO2 35-40 mmHg). Intra-operative analgesia is supplement by suppository paracetamol 20 mg/kg or diclofenac sodium 1mg/kg. Measurement of parameters
  4. Attempts required to successfully insert the device is recorded
  5. A successful insertion is defined as visible chest rise and a square wave trace on the capnograph. Failure of device is labelled where need more than 3 attempts to insert the device or alternative device is inserted or trachea is intubated.
  6. The time from the picking up the device and chest rise with positive pressure ventilation is recorded as time to insert.
  7. Oropharyngeal leak pressure (OLP) is recorded by observing the peak airway pressure at which audible leak occurred at the first time when fresh gas flow delivered at 3 litre/min and the expiratory valve is completely closed. For safety, OLP is not allowed to exceed >40 cmH20.
  8. Failure of device is also labelled if any intra-operative device repositioning or replacement of the device due to excessive air leak or airway obstruction as evidenced by an obstructive pattern on the capnograph leading to desaturation.
  9. Post-Operative At the end of surgery, sevoflurane is turned off and 100% oxygen is administered. Muscle relaxant is reversed by neostigmine (50 mcg/kg) and glycopyrrolate (10 mcg/kg). With adequate tidal volume and respiratory rate, oropharyngeal suctioning is done and the device is removed. On removal of the device, any presence of blood stain or tongue-lip-dental trauma is recorded. In the post-operative period, the participant is observed for any complications such as airway reflex activation (laryngospasm, bronchospasm or severe cough), oxygen desaturation (spO2 <90%) and vomiting/aspiration.
Being tested
Ambu Aura Gain supraglottic airway, Air-Q supraglottic airway
Keywords
Ambu Aura Gain, Air-Q intubating laryngeal airway, Paediatric surgery

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • Ambu Aura Gain supraglottic airwayDevice

    Anesthesia is induced with sevoflurane in oxygen. The anesthesia plane is gradually deepened by increasing the inspired concentration of sevoflurane (2-8%) till the loss of eyelash reflex. After intravenous (IV) cannula is inserted and intravenous fentanyl 1mcg/kg and rocuronium 0.6mg/kg are administered. Use of neuromuscular blocking agent is to minimize the risk of reflex activation of the airway. After 3 minutes, the appropriate size (depending upon body weight) of Ambu Aura Gain is lubricated with water soluble lubricant (KY jelly) is inserted by investigator based on manufacturer recommendation with the patient's head in neutral position. The cuff then is inflated to an intra-cuff pressure of 40 cm H20, measured using a digital cuff pressure monitor.

  • Air-Q supraglottic airwayDevice

    Anesthesia is induced with sevoflurane in oxygen. The anesthesia plane is gradually deepened by increasing the inspired concentration of sevoflurane (2-8%) till the loss of eyelash reflex. After intravenous (IV) cannula is inserted and intravenous fentanyl 1mcg/kg and rocuronium 0.6mg/kg are administered. Use of neuromuscular blocking agent is to minimize the risk of reflex activation of the airway. After 3 minutes, the appropriate size (depending upon body weight) of Air-Q supraglottic airway is lubricated with water soluble lubricant (KY jelly) is inserted by investigator based on manufacturer recommendation with the patient's head in neutral position. The cuff then is inflated to an intra-cuff pressure of 40 cm H20, measured using a digital cuff pressure monitor.

Study groups in NCT03130413
Study groupRoleWhat they receive
Ambu Aura GainExperimentalAmbu Aura Gain supraglottic airway size 2 or 2.5 will be inserted once patients are paralyzed
Receives: Device: Ambu Aura Gain supraglottic airway
Air-QActive comparatorAir-Q supraglottic airway size 1.5 and 2.0will be inserted once the patients are paralyzed
Receives: Device: Air-Q supraglottic airway

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. measure fibreoptic (FO) grade of laryngeal view

    Flexible fibreoptic scope is use to view anatomical alignment of the device to the larynx, 1cm proximal to the ventilating orifice

    Measured: 5 minutes after insertion of the device when good tidal volume is achieved

Secondary outcomes (8)
  1. oropharyngeal leak pressure (OLP)

    OLP is recorded by observing the peak airway pressure which audible leak occur at the first time when fresh gas flow delivered at 3 litre/min and the expiratory valve is completely closed

    Measured: 5 minutes after insertion of the device when good tidal volume is achieved

  2. number of attempt

    Measure number of attempts of inserting the devices

    Measured: Throughout the insertion process up to 5 minutes post induction

  3. Time of insertion

    Measure the time of successful insertion of the devices

    Measured: The time from which the device first being hold until successful insertion up to 5 minutes post induction

  4. Blood pressure

    Documented the blood pressure (BP) is recorded at different time interval

    Measured: Time from pre-induction until 5 minutes post insertion

  5. Heart rate

    Recorded the heart rate (HR) is recorded at different interval

    Measured: Time from pre-induction until 5 minutes post insertion

  6. Oxygen saturation (SpO2)

    Oxygen saturation (SpO2) is recorded at different interval

    Measured: Time from pre-induction until 5 minutes post insertion

  7. end tidal Carbon dioxide (EtCO2)

    The EtCO2 is recorded at different time interval

    Measured: Time from pre-induction until 5 minutes post insertion

  8. numbers of adverse effects of the devices as assessed by clinical observation

    Presence of adverse effect of the device postextubation

    Measured: Throughout the stay in recovery bay within 30 minutes after operation

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted26 Apr 2017
  2. Study startNov 2016
  3. Primary completion1 Jun 2018
  4. Study completion1 Jun 2018

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Interventional
Phase
Phase N/A
Primary purpose
Treatment
Allocation
Randomised
Intervention model
Parallel groups
Masking
Single blind
Who is masked
Participant
Enrolment
64 participants (actual)
IDs, dates and publications
ClinicalTrials.gov ID
NCT03130413
Sponsor's protocol ID
USM/JEPeM/15110476
Acronym
Nira
Status last verified
May 2018
First submitted
2 Apr 2017
Last updated
1 Jun 2018
Results posted
No
Data monitoring committee
Yes
Individual data sharing
No

Publications

  • Darlong V, Biyani G, Baidya DK, Pandey R, Chandralekha, Punj J, Upadhyay AD. Comparison of air-Q and Ambu Aura-i for controlled ventilation in infants: a randomized controlled trial. Paediatr Anaesth. 2015 Aug;25(8):795-800. doi: 10.1111/pan.12663. Epub 2015 Apr 27.

    PubMed 25917434
  • Darlong V, Biyani G, Pandey R, Baidya DK, Punj Ca. Comparison of performance and efficacy of air-Q intubating laryngeal airway and flexible laryngeal mask airway in anesthetized and paralyzed infants and children. Paediatr Anaesth. 2014 Oct;24(10):1066-71. doi: 10.1111/pan.12462.

    PubMed 24961960
  • Jagannathan N, Hajduk J, Sohn L, Huang A, Sawardekar A, Gebhardt ER, Johnson K, De Oliveira GS. A randomised comparison of the Ambu(R) AuraGain and the LMA(R) supreme in infants and children. Anaesthesia. 2016 Feb;71(2):205-12. doi: 10.1111/anae.13330. Epub 2015 Dec 9.

    PubMed 26648173
  • Whyte SD, Cooke E, Malherbe S. Usability and performance characteristics of the pediatric air-Q(R) intubating laryngeal airway. Can J Anaesth. 2013 Jun;60(6):557-63. doi: 10.1007/s12630-013-9918-6. Epub 2013 Mar 22.

    PubMed 23519724

Questions about this trial

What is this clinical trial studying?

A study testing Ambu Aura Gain supraglottic airway and Air-Q supraglottic airway in people with General Anaesthesia, run by Universiti Sains Malaysia at 1 site in Malaysia.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 5 inclusion and 3 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: finished, as of the sponsor's last update on 1 Jun 2018. Status can change between updates, so confirm with the study contact before making plans.

Where is the study taking place?

The record lists 1 site in Malaysia. Whether a site is taking part right now should be confirmed with that site. See every site.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.

How can a doctor refer a patient or contact the research team?

The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

measure fibreoptic (FO) grade of laryngeal view (time frame: 5 minutes after insertion of the device when good tidal volume is achieved). It is what the study was designed to measure, not a finding.

Where can I read the original study information?

On the ClinicalTrials.gov record for NCT03130413, which also lists 4 linked publications.

Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 1 Jun 2018.

Free account

Log in to keep searching

You’ve used your 3 free searches. AzTrials is free: log in or create a free account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in