Accuracy of Noninvasive Rainbow Adhesive R1 Pulse Oximeter Sensor
A study testing Rainbow Adhesive Noninvasive R1 Pulse Oximeter Sensor in people with Healthy, run by Masimo Corporation at 1 site in United States.
Trial summary
In this study, the concentration of hemoglobin will be measured using a noninvasive pulse oximeter sensor and compared with the hemoglobin value from a blood sample of the volunteer. The accuracy of a noninvasive hemoglobin sensor(s) will be assessed by comparison to hemoglobin measurements from a laboratory analyzer. Read more about this study
- Who is it for?
- Ages 18 years and olderHealthy volunteers can take part
- Conditions the study is for
- Healthy
- What is being tested?
- Rainbow Adhesive Noninvasive R1 Pulse Oximeter Sensor
- Type of treatment
- Medical device
- Could I receive a placebo?
- No, everyone receives an active treatment
- How many people
- 25 participants
- Where
- 1 siteUnited States
- Study dates
- 12 Dec 2008to 19 Jun 2009
- Phase
- Interventional
- Are there results?
- Yes, posted in the registrySummary in the doctors' view
Key requirements
Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.
- Ages 18 years and older
- All sexes
- Healthy volunteers accepted
- Adult, Older adult
Who may be able to join
- Greater than 18 years old
- Healthy
Who cannot join
- Do not understand the study and the risks involved
- Deemed ineligible by study test personnel
Trial locations and contacts
1 site in 1 country.
About this study
In this study, the concentration of hemoglobin will be measured using a noninvasive pulse oximeter sensor and compared with the hemoglobin value from a blood sample of the volunteer. The accuracy of a noninvasive hemoglobin sensor(s) will be assessed by comparison to hemoglobin measurements from a laboratory analyzer.
- Conditions
- Healthy
- Being tested
- Rainbow Adhesive Noninvasive R1 Pulse Oximeter Sensor
What participants receive
What participants receive. In a randomised study each person is assigned to one group by chance.
Rainbow Adhesive Noninvasive R1 Pulse Oximeter SensorDevice
| Study group | Role | What they receive |
|---|---|---|
| R1-25 Sensor | Experimental | All subjects will be enrolled in the test group and will receive Rainbow Adhesive Noninvasive R1 Pulse Oximeter Sensor Receives: Device: Rainbow Adhesive Noninvasive R1 Pulse Oximeter Sensor |
What is being measured
The primary outcome is the main question the study is designed to answer.
Accuracy of SpHb on R1-25 by Arms Calculation
Accuracy will be determined by comparing the noninvasive hemoglobin measurement of the pulse oximeter to the hemoglobin value obtained from a blood sample and calculating the arithmetic root mean square (Arms) error value. In order to obtain the Arms value, the blood sample hemoglobin value is subtracted from the pulse oximeter hemoglobin value for a number of samples, the average of this difference is computed as the bias. The standard deviation of the differences is computed as the precision. The square root of the sum of the squares of bias and precision is computed as the Arms Error value.
Measured: 1-5 hours per subject
Timeline
From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.
- First posted28 Apr 2017
- Study start12 Dec 2008
- Primary completion19 Jun 2009
- Study completion19 Jun 2009
Resources
- Official record on ClinicalTrials.govThe registry entry this page is built from, with its full change history.
- Posted resultsParticipant flow, outcome measures and adverse events reported by the sponsor.
- Other trials for HealthyStudies of the same condition, open and under way.
- What the trial phases meanHow a treatment moves from first tests in people to approval.
More details
For doctors and researchers: how the study is designed, who runs it, and its registry IDs.
Study design
- Study type
- Interventional
- Phase
- Phase N/A
- Primary purpose
- Other
- Allocation
- Not applicable
- Intervention model
- Single group
- Masking
- None (open label)
- Enrolment
- 25 participants (actual)
Sponsor and investigators
- Lead sponsor
- Masimo Corporation
- Sponsor type
- Industry (pharma, biotech, devices)
- Responsible party
- Sponsor
IDs, dates and publications
- ClinicalTrials.gov ID
- NCT03134313
- Sponsor's protocol ID
- TR18670-1029
- Status last verified
- Jun 2017
- First submitted
- 14 Apr 2017
- Last updated
- 2 Jul 2017
- Results posted
- Yes, on ClinicalTrials.gov
- FDA-regulated drug
- No
- FDA-regulated device
- Yes
Study at a glance
From the registry record, last updated by the sponsor on 2 Jul 2017. Recruitment status is as the sponsor reported it: confirm with the study team.
- Official title
- Accuracy of Noninvasive Rainbow Adhesive R1 Pulse Oximeter Sensor
- ClinicalTrials.gov ID
- NCT03134313
- Acronym / sponsor ID
- TR18670-1029
- Conditions
- Healthy
- Study type
- Interventional
- Recruitment status
- Completed
- Enrolment
- 25 participants (actual)
- Lead sponsor
- Masimo CorporationIndustry (pharma, biotech, devices)
- Study start
- 12 Dec 2008 (actual)
- Primary completion
- 19 Jun 2009 (actual)
- Study completion
- 19 Jun 2009 (actual)
- First posted
- 28 Apr 2017 (actual)
- Results
- Posted 2 Jul 2017
Clinical summary
The research question as the sponsor registered it. This describes what the study plans to test, not what it found.
In this study, the concentration of hemoglobin will be measured using a noninvasive pulse oximeter sensor and compared with the hemoglobin value from a blood sample of the volunteer. The accuracy of a noninvasive hemoglobin sensor(s) will be assessed by comparison to hemoglobin measurements from a laboratory analyzer.
Study design
- Primary purpose
- Other
- Allocation
- Not applicable
- Intervention model
- Single group
- Masking
- None (open label)
- Number of arms
- 1
| Arm | Type | Receives |
|---|---|---|
| R1-25 Sensor | Experimental | Device: Rainbow Adhesive Noninvasive R1 Pulse Oximeter SensorAll subjects will be enrolled in the test group and will receive Rainbow Adhesive Noninvasive R1 Pulse Oximeter Sensor |
Who may qualify
- Ages
- 18 years and older
- Sex
- All
- Healthy volunteers
- Accepted
- Age groups
- Adult, Older adult
Key inclusion criteria (2 listed)
- Greater than 18 years old
- Healthy
Key exclusion criteria (2 listed)
- Do not understand the study and the risks involved
- Deemed ineligible by study test personnel
Eligibility is decided by the study team after screening; this overview does not establish that a patient qualifies. Full inclusion and exclusion criteria.
Interventions
| Intervention | Type | Arms |
|---|---|---|
| Rainbow Adhesive Noninvasive R1 Pulse Oximeter Sensor | Device | R1-25 Sensor |
Primary outcome
Accuracy of SpHb on R1-25 by Arms Calculation
Time frame: 1-5 hours per subject
Accuracy will be determined by comparing the noninvasive hemoglobin measurement of the pulse oximeter to the hemoglobin value obtained from a blood sample and calculating the arithmetic root mean square (Arms) error value. In order to obtain the Arms value, the blood sample hemoglobin value is subtracted from the pulse oximeter hemoglobin value for a number of samples, the average of this difference is computed as the bias. The standard deviation of the differences is computed as the precision. The square root of the sum of the squares of bias and precision is computed as the Arms Error value.
Results and safety
Loading the posted results from ClinicalTrials.gov…
Research links
- Official record on ClinicalTrials.govLast updated by the sponsor 2 Jul 2017.
- Posted resultsParticipant flow, baseline, all outcome measures and adverse events.
Related trials for Healthy
Recruiting
THE EFFECTS OF GAME-BASED EXERCISE PROGRAMS
Physical Activity, Body Image
Not yet recruitingPhase 1
A Phase I Study of GLR2053 Tablets in Chinese Healthy Adult Participants
Atopic Dermatitis
Recruiting
Colon-delivered Riboflavin and Gut Microbiota Composition
Microbiome Dysbiosis, Gut Health
Not yet recruiting
Neuroergonomic Analysis of a Brain-Computer Interface Device (BCI)
Healthy Volunteers - Male and Female
RecruitingPhase 1
First-in-Human Trial to Assess REGN20423 in Healthy Adult Participants and Adult Participants With Atopic Dermatitis
Healthy Volunteer, Atopic Dermatitis
Referral and contact
AzTrials does not enrol participants or take referrals. Contact the study team or a site listed below; they decide who can take part. This study is not recruiting at the moment.
The record lists no contact. Use the official record to reach the sponsor.
1 site in 1 country: see every site and its status.
Questions about this trial
What is this clinical trial studying?
A study testing Rainbow Adhesive Noninvasive R1 Pulse Oximeter Sensor in people with Healthy, run by Masimo Corporation at 1 site in United States.
The full registered description is in the About this study section and the official record.
Who may be eligible to take part?
The sponsor lists 2 inclusion and 2 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.
Is this clinical trial currently recruiting?
The record says: finished, as of the sponsor's last update on 2 Jul 2017. Status can change between updates, so confirm with the study contact before making plans.
Where is the study taking place?
The record lists 1 site in United States. Whether a site is taking part right now should be confirmed with that site. See every site.
What are the possible benefits and risks?
They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.
Are results available for this study?
Yes. Results are posted in the registry (first posted 2 Jul 2017). A summary is in the For doctors view, and the full results are on ClinicalTrials.gov.
How can a doctor refer a patient or contact the research team?
The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.
What does the primary outcome measure?
Accuracy of SpHb on R1-25 by Arms Calculation (time frame: 1-5 hours per subject). It is what the study was designed to measure, not a finding.
Where can I read the original study information?
Does a listing mean the treatment is approved or proven to work?
No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.
How often is this information updated?
AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 2 Jul 2017.