AzTrials
AzTrials

Skin CancerNCT03145506

Spectrally Guided Mohs Surgery

An observational study of Skin Cancer, run by Seton Healthcare Family.

Completed

Finished. The study has ended and is not enrolling. Results may be posted on the official record.

Official record
Search all trials

Trial summary

Freshly excised or freshly frozen tissue for Raman analysis will be obtained from a dermatology practice affiliated with UMCB. In the course of the routine removal of benign or malignant tumors in the office, skin cancer surgeons routinely check frozen sections to ensure adequate margins are obtained. Read more about this study

Who is it for?
Ages 18 to 99 years
Conditions the study is for
Skin Cancer
What is being tested?
Multimodal Spectroscopy
Type of treatment
Medical device
How many people
24 participants
Where
No sites listed yet
Study dates
Nov 2016to Jul 2018
Phase
Observational
Are there results?
None posted in the registry

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 18 to 99 years
  • All sexes
  • No healthy volunteers
  • Adult, Older adult

Study population: All patients undergoing treatment for SCC or BCC in local Mohs surgery clinic

Who may be able to join

  • All individuals over 18 undergoing Mohs surgery for treatment of BCC or SCC

Who cannot join

  • Under 18 years old, not undergoing Mohs surgery for treatment of BCC or SCC

About this study

Freshly excised or freshly frozen tissue for Raman analysis will be obtained from a dermatology practice affiliated with UMCB. In the course of the routine removal of benign or malignant tumors in the office, skin cancer surgeons routinely check frozen sections to ensure adequate margins are obtained. Consent will be obtained from patients to provide freshly excised or freshly frozen leftover tissue obtained during Mohs surgery to be discarded after histological diagnosis. Freshly excised tissue will be measured at the time of excision before processing, while the freshly frozen tissue samples will be stored in a freezer at the Mohs clinic and transferred to the UT- Austin campus for spectroscopic analysis.

Read the detailed description

The current standard-of-care in the identification of skin cancer is visual inspection followed by biopsy and histopathology of suspicious skin sites. Since a physician is required to perform this biopsy, there is often a delay in diagnosis, resulting in deeper, more aggressive tumors and increased mortality from malignant melanoma (MM). Therefore, a non-invasive method to inspect these lesions would be of great clinical importance.

An initial prototype of a noninvasive diagnostic device was developed based on optical spectroscopy and completed a clinical study in 76 patients that demonstrated high diagnostic accuracy for the detection of skin cancer (IRB # CR-10-004). This initial prototype consisted of two separate devices and probes: one to collect Raman spectra (RS) and the other to collect diffuse reflectance and laser induced fluorescence spectra (DRS+LIFS). type, but a combination of modalities gave the best diagnostic performance for all types of skin cancer.

The addition of Raman spectroscopy improved diagnostic performance for both melanoma and non-melanoma skin cancer. However, the operation of the integrated systems was still conducted via two optical fiber probes (the first one for fluorescence and reflectance spectroscopy, the second one for Raman spectroscopy). The need to take measurements of the same lesion using two probes increased acquisition time, and the possible sampling site error. Recently, a device was developed that combined fiber optic probe that is capable for spectral acquisition of Raman, white light reflectance and laser induced fluorescence spectroscopy. Using this probe, acquisition time and sampling site error should be reduced. There is no significant difference in terms of performance between the previous two probes and the new probe.

Models have been developed to analyze reflectance and fluorescence spectroscopy data. In order to interpret Raman spectroscopy data in physiologically relevant parameters, a biophysical model needs to be developed. Similar models have been developed by other research groups for other types of tissue.

This study proposes to use the new technique of biophysical modeling to analyze our Raman spectra. At the core of the technique is the measurement of a set of "basis spectra" which are fit to the data using ordinary least-squares. Recently, biophysical models have been developed for atherosclerosis and breast cancer with very impressive diagnostic results, achieving 94% sensitivity and 96% specificity for breast cancer and 94% accuracy for atherosclerosis disease classification.

Raman microspectrometry will be used to measure basis spectra from various skin constituents. In this technique, Raman spectra are measured from freshly frozen tissue samples that are sliced into thin sections as is done in histology. A microscope system is used to focus the excitation laser beam to a small spot of approximately 2 mm in diameter on the sample, and a Raman spectrometer measures the emitted Raman spectrum. In this way, Raman spectra of individual microscopic tissue components can be isolated. These individual component spectra will be determined for keratin, cell nuclei, collagen, cytoplasm, melanin, water, sebaceous glands, etc.

Conditions
Skin Cancer
Being tested
Multimodal Spectroscopy
Medical subject headings
Skin Neoplasms

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • Multimodal SpectroscopyDevice

    optical measurement of excised tissue

Study groups in NCT03145506
Study groupRoleWhat they receive
Mohs Surgery PatientsAdult patients undergoing Mohs surgery for treatment of BCC or SCC
Receives: Device: Multimodal Spectroscopy

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. Sensitivity and specificity of spectroscopic device

    comparison of spectroscopic data to frozen section pathology used in Mohs surgery

    Measured: 1 year

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted9 May 2017
  2. Study startNov 2016
  3. Primary completionDec 2016
  4. Study completionJul 2018

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Observational
Observational model
Other
Time perspective
Prospective
Enrolment
24 participants (actual)
IDs, dates and publications
ClinicalTrials.gov ID
NCT03145506
Sponsor's protocol ID
CR-15-117
Status last verified
Apr 2018
First submitted
24 Apr 2017
Last updated
16 Aug 2018
Results posted
No
Data monitoring committee
No
FDA-regulated drug
No
FDA-regulated device
No
Individual data sharing
No

Questions about this trial

What is this clinical trial studying?

An observational study of Skin Cancer, run by Seton Healthcare Family.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 1 inclusion and 1 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: finished, as of the sponsor's last update on 16 Aug 2018. Status can change between updates, so confirm with the study contact before making plans.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.

How can a doctor refer a patient or contact the research team?

The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

Sensitivity and specificity of spectroscopic device (time frame: 1 year). It is what the study was designed to measure, not a finding.

Where can I read the original study information?
Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 16 Aug 2018.

Free account

Keep searching with a free account

You’ve used your 3 free searches for this session. Log in or create a free AzTrials account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in