Alarms Due to Loss of Signal Integrity in Partially Wireless Versus Traditional Pulse Oximetry in Pediatric Patients
An observational study of Healthy, run by Pamela Petersen at 1 site in United States.
Trial summary
This research study will help the investigators to learn more about a device used when children are sick called a pulse oximeter. The pulse oximeter measures how much oxygen is inside a child's blood without taking blood from the child. It is non-invasive meaning it does not enter the body. Read more about this study
- Who is it for?
- Ages 6 months to 17 yearsHealthy volunteers can take part
- Conditions the study is for
- Healthy
- What is being tested?
- Radical 7 and Radius 7
- Type of treatment
- Medical device
- How many people
- 36 participants
- Where
- 1 siteUnited States
- Study dates
- 26 Jul 2017to 1 Nov 2017
- Phase
- Observational
- Are there results?
- None posted in the registry
Key requirements
Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.
- Ages 6 months to 17 years
- All sexes
- Healthy volunteers accepted
- Child
Study population: The subjects will be a sampling from the communities served by the Children's Hospital of Wisconsin. Pediatric subjects will be recruited via fliers placed in pediatric critical care areas, in the Translational Research Control Unit (TRU) and on the Medical College of Wisconsin (MCW) research bulletin board outside the MCW office of research. Subjects may include those responding to the fliers directly as well as the healthy siblings of patients being evaluated or treated in the Children's Hospital of Wisconsin Emergency Room (EDTC), Clinics or Hospital.
Who may be able to join
- Healthy subjects between the ages of 6 months and 17 years at the time of data acquisition.
Who cannot join
- Subjects will be excluded if they have any pre-existing cardiac or pulmonary chronic medical diagnoses as determined by asking the subject's guardian.
Trial locations and contacts
1 site in 1 country.
United States1 site
Children's Hospital of Wisconsin
Milwaukee, Wisconsin, 53226
About this study
Official title: The Ties That Bind: Evaluation of a Patient-worn Pulse Oximeter Compared to Traditional Pulse Oximetry on Loss of Signal Integrity in Pediatric Patients
This research study will help the investigators to learn more about a device used when children are sick called a pulse oximeter. The pulse oximeter measures how much oxygen is inside a child's blood without taking blood from the child. It is non-invasive meaning it does not enter the body. The device has a cable attached to it. At the end of the cable is a wrap that looks like a Band-Aid with a red light on it. This wrap is placed around a finger or toe. The red light gives the investigators a reading of how much oxygen is in the child's blood and the child's heart rate. Having a pulse oximeter connected to a child is painless. This device is used in many places. Besides hospitals, it is used in doctors' offices and in fitness centers.
This study will help the investigators learn more about whether a partially wireless, more portable pulse oximeter that connects to a small device worn on the child's arm or leg will give the investigators a more reliable signal/reading while letting children move more easily. The investigators will compare this device with the traditional wall-connected unit. Movement of the cable or a child moving may give a false oxygen reading. The investigators will ask the child to do activities that create movement and will look at the readings when the child moves. The investigators think the partially wireless pulse oximeter will be more reliable during movement than the traditional wall-connected unit.
Subjects will have two continuous pulse oximeter probes placed on them. These soft probes will go on a finger, toe, foot or hand and will be attached to two different pulse oximeter monitors. The child will then be asked to do common childhood activities based on their age for about 20 minutes. These activities will be play activities the child already does such as grabbing a toy, drawing with crayons or kicking a ball. Continuous pulse oximetry data will be recorded during the testing and will be stored in a way that it cannot be linked to the subject after the testing is complete.
Read the detailed description
PURPOSE OF THE STUDY This study will evaluate the loss of signal integrity secondary to motion in pediatric subjects being monitored with a newer, partially wireless pulse oximeter (the Radius 7) which eliminates the cable connecting the subject to a wall unit by instead connecting to a small device worn on the subject's arm or leg. The Radius 7 will be compared to the traditional wall-connected pulse oximeter currently used at Children's Hospital of Wisconsin (CHW) which requires a cable connecting to a wall unit (the Radical 7).
HYPOTHESIS Continuously monitoring pulse oximetry with a partially wireless monitor without physical connection to a wall unit will decrease episodes of loss of signal integrity generated by motion artifact in healthy pediatric subjects completing age appropriate activities.
BACKGROUND, SIGNIFICANCE, AND RATIONALE Pulse oximetry is used in both inpatient and outpatient environments to measure the oxygen saturation in a person's blood and the pulse, or heart rate. Pulse oximeters use a painless Band-Aid-like probe that attaches to a fingertip, toe, hand or foot and shines a light through the skin. The monitor then determines how much oxygen is in the blood and the pulse rate based on the way the light passes through the skin. The probe is connected to the monitor by a cable of varying lengths. Movement can cause incorrect pulse oximeter measurements.
Continuous pulse oximetry is considered a standard of care in pediatric intensive care units; however pediatric patients have a high incidence of false alarms in part due to motion artifact. These false alarms contribute to the 94% false alarm incidence in pediatric ICU patients. (Lawless) Motion artifact is potentially exacerbated by the long cables connecting the patients to the continuous monitors. Currently the FDA has not approved any completely cable-free pulse oximeters for continuous use; however Masimo has produced a device (the Radius 7) that overcomes the previously required cable connection to a wall unit via wireless transmission from a patient-worn continuous monitor. (Masimo) There are currently no studies looking at this patient worn monitor in relation to the motion artifacts that frequently cause false alarms in pediatric patients.
The Joint Commission has listed alarm fatigue as a top patient safety concern and as of January 1, 2016 has required hospitals to establish policies and procedures for managing alarm fatigue. Reduction in false alarms is necessary to reduce alarm fatigue. This pilot study will use clinical data to measure the effect of eliminating this cable-to-wall connection on motion artifact. Additionally, early mobility in critically ill patients has been shown to improve outcomes. Freeing patients from one of the cables currently tying them to the room may decrease the false alarms from motion artifact while simultaneously improving mobility, therefore improving patient outcomes and safety.
DESIGN AND METHODS Subjects: Healthy pediatric subjects ranging from 6 months to 17 years of age. Pediatric subjects will be recruited via fliers placed in pediatric critical care areas, in the Translational Research Control Unit (TRU) and on the MCW research bulletin board outside the MCW office of research. Subjects may include those responding to the fliers directly as well as the healthy siblings of patients being evaluated or treated in the Children's Hospital of Wisconsin Emergency Room (EDTC), Clinics or Hospital.
Setting: The Children's Hospital of Wisconsin (CHW): primarily in the TRU designed to mimic a CHW outpatient clinic room; and also including available sites near the EDTC or clinic to facilitate making testing more convenient for the subject's family if the subject is a healthy sibling of a patient being evaluated in the EDTC or clinic.
Procedures:
While being continuously monitored on the current equipment used by CHW (the wall-connected Radical 7) and the partially wireless Radius 7 pulse oximeter, subjects will be asked to complete age appropriate activities as developed by CHW physical therapists, for approximately twenty minutes. These activities include common childhood activities such as kicking a ball or drawing with crayons. If a subject declines to participate in an activity, an alternate will be suggested. The investigators will analyze the pulse oximetry data for instances of alarm state corresponding to loss of signal integrity as defined by complete inability to pick up the subject signal or a change in the pulse oximetry saturation value by 4%. (Seixas, Seixas and Pereira)
Endpoints: Enrollment of and data acquisition on 48 pediatric subjects: 12 in each of the following developmental age groups: 6 month-1year, 1-6 years, 6-10 years, and 11-17 years.
Data analysis:
All data will be collected in a de-identified manner in which subjects will be given a study case number and all data will be collected under that case number.
The number of episodes of loss of signal integrity leading to an alarm state generated by the wall-connected Radical 7 unit compared to the partially wireless Radius 7 unit during completion of the developmentally appropriate activities will be compared. Analysis will be performed by the Quantitative Health Sciences department at MCW and a 20% reduction in episodes of loss of signal integrity will be considered clinically significant.
TOTAL NUMBER OF HUMAN RESEARCH PARTICIPANTS PROPOSED FOR THIS STUDY. 48 pediatric subjects: 12 in each of the following developmental age groups: 6 months-1year, 1-6 years, 6-10 years, and 11-17 years. This number of participants will provide representative data for a pilot study investigating the most common age groups seen in the pediatric ICU in order to identify the age groups most likely to benefit from further study.
- Conditions
- Healthy
- Being tested
- Radical 7, Radius 7
- Keywords
- Pediatric, Pulse Oximeter, Wireless, Motion, False Alarm
What participants receive
What participants receive. In a randomised study each person is assigned to one group by chance.
Radical 7Device
Also called Masimo Radical 7 Pulse Oximeter
The Radical 7 is the traditional wall-connected pulse oximeter currently used at Children's Hospital of Wisconsin (CHW) which requires a 12 foot cable connecting the patient to a wall unit. While being continuously monitored with the Radical 7 pulse oximeter, subjects will be asked to complete age appropriate activities. The pulse oximetry data will be analyzed for instances of alarm state corresponding to loss of signal integrity as defined by complete inability to pick up the subject signal or a change in the pulse oximetry saturation value by 4%.
Radius 7Device
Also called Masimo Radius 7 Pulse Oximeter
The Radius 7 is a newer, partially wireless pulse oximeter which eliminates the cable connecting the patient to a wall unit by instead connecting to a small device worn on the patient's arm or leg. The small device then sends the continuous pulse oximeter data wirelessly to the central monitoring station. While being continuously monitored with the Radius 7 pulse oximeter, subjects will be asked to complete age appropriate activities. The pulse oximetry data will be analyzed for instances of alarm state corresponding to loss of signal integrity as defined by complete inability to pick up the subject signal or a change in the pulse oximetry saturation value by 4%.
| Study group | Role | What they receive |
|---|---|---|
| 1-6 years | 12 subjects in the age range of 1-6 years old. Receives: Device: Radical 7; Device: Radius 7 | |
| 6-10 years | 12 subjects in the age range of 6-10 years old. Receives: Device: Radical 7; Device: Radius 7 | |
| 11-17 years | 12 subjects in the age range of 11-17 years old. Receives: Device: Radical 7; Device: Radius 7 |
What is being measured
The primary outcome is the main question the study is designed to answer.
instances of alarm state corresponding to loss of signal integrity
Loss of signal integrity is defined as complete inability to pick up the patient signal or a change in the pulse oximetry saturation value by 4%.
Measured: 20 minutes
Timeline
From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.
- First posted15 Jun 2017
- Study start26 Jul 2017
- Primary completion1 Nov 2017
- Study completion1 Nov 2017
Resources
- Official record on ClinicalTrials.govThe registry entry this page is built from, with its full change history.
- Publications (2)Papers the sponsor has linked to this study.
- Other trials for HealthyStudies of the same condition, open and under way.
- What the trial phases meanHow a treatment moves from first tests in people to approval.
More details
For doctors and researchers: how the study is designed, who runs it, and its registry IDs.
Study design
- Study type
- Observational
- Observational model
- Case only
- Time perspective
- Prospective
- Enrolment
- 36 participants (actual)
Sponsor and investigators
- Lead sponsor
- Pamela Petersen
- Sponsor type
- University, hospital or other
- Responsible party
- Sponsor-investigator, Pamela Petersen, Medical College of Wisconsin
- Investigators
- Pamela C Petersen, M.D., Principal investigator, Medical College of Wisconsin Affiliated Hospitals, Inc.Sheila Hanson, M.D., Principal investigator, Medical College of Wisconsin Affiliated Hospitals, Inc.
IDs, dates and publications
- ClinicalTrials.gov ID
- NCT03187665
- Sponsor's protocol ID
- 953341-1
- Status last verified
- Nov 2017
- First submitted
- 13 Jun 2017
- Last updated
- 24 Nov 2017
- Results posted
- No
- Data monitoring committee
- No
- FDA-regulated drug
- No
- FDA-regulated device
- Yes
- Individual data sharing
- Yes: At the end of the study, Masimo, who makes both of the pulse oximeters, will be able to see de-identified information. They will not be allowed to see "Protected Health Information" (PHI). IPD that will be shared includes Subject Number, Age, Race, Gender, Probe Location (dominant vs. nondominant hand), Activity (Likert score), Start time of activity, Stop time of activity, Radius 7 Probe location, Radical 7 Probe location, Instance of alarm state Radius 7, Duration of alarm state Radius 7, Loss of signal integrity Radius 7-Change in pulse ox saturation of 4% or more, Loss of signal integrity Radius 7-no signal, Instance of alarm state Radical 7, Duration of alarm state Radical 7, Loss of signal integrity Radical 7-Change in pulse ox saturation of 4% or more, and Loss of signal integrity Radical 7-no signal. This de-identified data with no PHI will be shared via USB stick or e-mail electronically.
Publications
Lawless ST. Crying wolf: false alarms in a pediatric intensive care unit. Crit Care Med. 1994 Jun;22(6):981-5.
PubMed 8205831Seixas DM, Seixas DM, Pereira MC, Moreira MM, Paschoal IA. Oxygen desaturation in healthy subjects undergoing the incremental shuttle walk test. J Bras Pneumol. 2013 Jun-Aug;39(4):440-6. doi: 10.1590/S1806-37132013000400007.
PubMed 24068265
Study at a glance
From the registry record, last updated by the sponsor on 24 Nov 2017. Recruitment status is as the sponsor reported it: confirm with the study team.
- Official title
- The Ties That Bind: Evaluation of a Patient-worn Pulse Oximeter Compared to Traditional Pulse Oximetry on Loss of Signal Integrity in Pediatric Patients
- ClinicalTrials.gov ID
- NCT03187665
- Acronym / sponsor ID
- 953341-1
- Conditions
- Healthy
- Keywords
- Pediatric, Pulse Oximeter, Wireless, Motion, False Alarm
- Study type
- Observational
- Recruitment status
- Completed
- Enrolment
- 36 participants (actual)
- Lead sponsor
- Pamela PetersenUniversity, hospital or other
- Study start
- 26 Jul 2017 (actual)
- Primary completion
- 1 Nov 2017 (actual)
- Study completion
- 1 Nov 2017 (actual)
- First posted
- 15 Jun 2017 (actual)
- Results
- Not posted in the source record
Clinical summary
The research question as the sponsor registered it. This describes what the study plans to test, not what it found.
This research study will help the investigators to learn more about a device used when children are sick called a pulse oximeter. The pulse oximeter measures how much oxygen is inside a child's blood without taking blood from the child. It is non-invasive meaning it does not enter the body. The device has a cable attached to it. At the end of the cable is a wrap that looks like a Band-Aid with a red light on it. This wrap is placed around a finger or toe. The red light gives the investigators a reading of how much oxygen is in the child's blood and the child's heart rate. Having a pulse oximeter connected to a child is painless. This device is used in many places. Besides hospitals, it is used in doctors' offices and in fitness centers.
This study will help the investigators learn more about whether a partially wireless, more portable pulse oximeter that connects to a small device worn on the child's arm or leg will give the investigators a more reliable signal/reading while letting children move more easily. The investigators will compare this device with the traditional wall-connected unit. Movement of the cable or a child moving may give a false oxygen reading. The investigators will ask the child to do activities that create movement and will look at the readings when the child moves. The investigators think the partially wireless pulse oximeter will be more reliable during movement than the traditional wall-connected unit.
Subjects will have two continuous pulse oximeter probes placed on them. These soft probes will go on a finger, toe, foot or hand and will be attached to two different pulse oximeter monitors. The child will then be asked to do common childhood activities based on their age for about 20 minutes. These activities will be play activities the child already does such as grabbing a toy, drawing with crayons or kicking a ball. Continuous pulse oximetry data will be recorded during the testing and will be stored in a way that it cannot be linked to the subject after the testing is complete.
Detailed description
PURPOSE OF THE STUDY This study will evaluate the loss of signal integrity secondary to motion in pediatric subjects being monitored with a newer, partially wireless pulse oximeter (the Radius 7) which eliminates the cable connecting the subject to a wall unit by instead connecting to a small device worn on the subject's arm or leg. The Radius 7 will be compared to the traditional wall-connected pulse oximeter currently used at Children's Hospital of Wisconsin (CHW) which requires a cable connecting to a wall unit (the Radical 7).
HYPOTHESIS Continuously monitoring pulse oximetry with a partially wireless monitor without physical connection to a wall unit will decrease episodes of loss of signal integrity generated by motion artifact in healthy pediatric subjects completing age appropriate activities.
BACKGROUND, SIGNIFICANCE, AND RATIONALE Pulse oximetry is used in both inpatient and outpatient environments to measure the oxygen saturation in a person's blood and the pulse, or heart rate. Pulse oximeters use a painless Band-Aid-like probe that attaches to a fingertip, toe, hand or foot and shines a light through the skin. The monitor then determines how much oxygen is in the blood and the pulse rate based on the way the light passes through the skin. The probe is connected to the monitor by a cable of varying lengths. Movement can cause incorrect pulse oximeter measurements.
Continuous pulse oximetry is considered a standard of care in pediatric intensive care units; however pediatric patients have a high incidence of false alarms in part due to motion artifact. These false alarms contribute to the 94% false alarm incidence in pediatric ICU patients. (Lawless) Motion artifact is potentially exacerbated by the long cables connecting the patients to the continuous monitors. Currently the FDA has not approved any completely cable-free pulse oximeters for continuous use; however Masimo has produced a device (the Radius 7) that overcomes the previously required cable connection to a wall unit via wireless transmission from a patient-worn continuous monitor. (Masimo) There are currently no studies looking at this patient worn monitor in relation to the motion artifacts that frequently cause false alarms in pediatric patients.
The Joint Commission has listed alarm fatigue as a top patient safety concern and as of January 1, 2016 has required hospitals to establish policies and procedures for managing alarm fatigue. Reduction in false alarms is necessary to reduce alarm fatigue. This pilot study will use clinical data to measure the effect of eliminating this cable-to-wall connection on motion artifact. Additionally, early mobility in critically ill patients has been shown to improve outcomes. Freeing patients from one of the cables currently tying them to the room may decrease the false alarms from motion artifact while simultaneously improving mobility, therefore improving patient outcomes and safety.
DESIGN AND METHODS Subjects: Healthy pediatric subjects ranging from 6 months to 17 years of age. Pediatric subjects will be recruited via fliers placed in pediatric critical care areas, in the Translational Research Control Unit (TRU) and on the MCW research bulletin board outside the MCW office of research. Subjects may include those responding to the fliers directly as well as the healthy siblings of patients being evaluated or treated in the Children's Hospital of Wisconsin Emergency Room (EDTC), Clinics or Hospital.
Setting: The Children's Hospital of Wisconsin (CHW): primarily in the TRU designed to mimic a CHW outpatient clinic room; and also including available sites near the EDTC or clinic to facilitate making testing more convenient for the subject's family if the subject is a healthy sibling of a patient being evaluated in the EDTC or clinic.
Procedures:
While being continuously monitored on the current equipment used by CHW (the wall-connected Radical 7) and the partially wireless Radius 7 pulse oximeter, subjects will be asked to complete age appropriate activities as developed by CHW physical therapists, for approximately twenty minutes. These activities include common childhood activities such as kicking a ball or drawing with crayons. If a subject declines to participate in an activity, an alternate will be suggested. The investigators will analyze the pulse oximetry data for instances of alarm state corresponding to loss of signal integrity as defined by complete inability to pick up the subject signal or a change in the pulse oximetry saturation value by 4%. (Seixas, Seixas and Pereira)
Endpoints: Enrollment of and data acquisition on 48 pediatric subjects: 12 in each of the following developmental age groups: 6 month-1year, 1-6 years, 6-10 years, and 11-17 years.
Data analysis:
All data will be collected in a de-identified manner in which subjects will be given a study case number and all data will be collected under that case number.
The number of episodes of loss of signal integrity leading to an alarm state generated by the wall-connected Radical 7 unit compared to the partially wireless Radius 7 unit during completion of the developmentally appropriate activities will be compared. Analysis will be performed by the Quantitative Health Sciences department at MCW and a 20% reduction in episodes of loss of signal integrity will be considered clinically significant.
TOTAL NUMBER OF HUMAN RESEARCH PARTICIPANTS PROPOSED FOR THIS STUDY. 48 pediatric subjects: 12 in each of the following developmental age groups: 6 months-1year, 1-6 years, 6-10 years, and 11-17 years. This number of participants will provide representative data for a pilot study investigating the most common age groups seen in the pediatric ICU in order to identify the age groups most likely to benefit from further study.
Study design
- Observational model
- Case only
- Time perspective
- Prospective
- Number of arms
- 3
| Arm | Type | Receives |
|---|---|---|
| 1-6 years | – | Device: Radical 7, Device: Radius 712 subjects in the age range of 1-6 years old. |
| 6-10 years | – | Device: Radical 7, Device: Radius 712 subjects in the age range of 6-10 years old. |
| 11-17 years | – | Device: Radical 7, Device: Radius 712 subjects in the age range of 11-17 years old. |
Who may qualify
- Ages
- 6 months to 17 years
- Sex
- All
- Healthy volunteers
- Accepted
- Age groups
- Child
- Study population
- The subjects will be a sampling from the communities served by the Children's Hospital of Wisconsin. Pediatric subjects will be recruited via fliers placed in pediatric critical care areas, in the Translational Research Control Unit (TRU) and on the Medical College of Wisconsin (MCW) research bulletin board outside the MCW office of research. Subjects may include those responding to the fliers directly as well as the healthy siblings of patients being evaluated or treated in the Children's Hospital of Wisconsin Emergency Room (EDTC), Clinics or Hospital.
Key inclusion criteria (1 listed)
- Healthy subjects between the ages of 6 months and 17 years at the time of data acquisition.
Key exclusion criteria (1 listed)
- Subjects will be excluded if they have any pre-existing cardiac or pulmonary chronic medical diagnoses as determined by asking the subject's guardian.
Eligibility is decided by the study team after screening; this overview does not establish that a patient qualifies. Full inclusion and exclusion criteria.
Interventions
| Intervention | Type | Arms |
|---|---|---|
| Radical 7Also: Masimo Radical 7 Pulse OximeterThe Radical 7 is the traditional wall-connected pulse oximeter currently used at Children's Hospital of Wisconsin (CHW) which requires a 12 foot cable connecting the patient to a wall unit. While being continuously monitored with the Radical 7 pulse oximeter, subjects will be asked to complete age appropriate activities. The pulse oximetry data will be analyzed for instances of alarm state corresponding to loss of signal integrity as defined by complete inability to pick up the subject signal or a change in the pulse oximetry saturation value by 4%. | Device | 1-6 years, 11-17 years, 6-10 years |
| Radius 7Also: Masimo Radius 7 Pulse OximeterThe Radius 7 is a newer, partially wireless pulse oximeter which eliminates the cable connecting the patient to a wall unit by instead connecting to a small device worn on the patient's arm or leg. The small device then sends the continuous pulse oximeter data wirelessly to the central monitoring station. While being continuously monitored with the Radius 7 pulse oximeter, subjects will be asked to complete age appropriate activities. The pulse oximetry data will be analyzed for instances of alarm state corresponding to loss of signal integrity as defined by complete inability to pick up the subject signal or a change in the pulse oximetry saturation value by 4%. | Device | 1-6 years, 11-17 years, 6-10 years |
Primary outcome
instances of alarm state corresponding to loss of signal integrity
Time frame: 20 minutes
Loss of signal integrity is defined as complete inability to pick up the patient signal or a change in the pulse oximetry saturation value by 4%.
Results and safety
The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.
Research links
- Official record on ClinicalTrials.govLast updated by the sponsor 24 Nov 2017.
- Background: PubMed 8205831Lawless ST. Crying wolf: false alarms in a pediatric intensive care unit. Crit Care Med. 1994 Jun;22(6):981-5.
- Background: PubMed 24068265Seixas DM, Seixas DM, Pereira MC, Moreira MM, Paschoal IA. Oxygen desaturation in healthy subjects undergoing the incremental shuttle walk test. J Bras Pneumol. 2013 Jun-Aug;39(4):440-6. doi: 10.1590/S1806-37132013000400007.
- Individual participant dataSharing planned: Yes. At the end of the study, Masimo, who makes both of the pulse oximeters, will be able to see de-identified information. They will not be allowed to see "Protected Health Information" (PHI). IPD that will be shared includes Subject Number, Age, Race, Gender, Probe Location (dominant vs. nondominant hand), Activity (Likert score), Start time of activity, Stop time of activity, Radius 7 Probe location, Radical 7 Probe location, Instance of alarm state Radius 7, Duration of alarm state Radius 7, Loss of signal integrity Radius 7-Change in pulse ox saturation of 4% or more, Loss of signal integrity Radius 7-no signal, Instance of alarm state Radical 7, Duration of alarm state Radical 7, Loss of signal integrity Radical 7-Change in pulse ox saturation of 4% or more, and Loss of signal integrity Radical 7-no signal. This de-identified data with no PHI will be shared via USB stick or e-mail electronically.
Related trials for Healthy
Recruiting
THE EFFECTS OF GAME-BASED EXERCISE PROGRAMS
Physical Activity, Body Image
Not yet recruitingPhase 1
A Phase I Study of GLR2053 Tablets in Chinese Healthy Adult Participants
Atopic Dermatitis
Recruiting
Colon-delivered Riboflavin and Gut Microbiota Composition
Microbiome Dysbiosis, Gut Health
Not yet recruiting
Neuroergonomic Analysis of a Brain-Computer Interface Device (BCI)
Healthy Volunteers - Male and Female
RecruitingPhase 1
First-in-Human Trial to Assess REGN20423 in Healthy Adult Participants and Adult Participants With Atopic Dermatitis
Healthy Volunteer, Atopic Dermatitis
Referral and contact
AzTrials does not enrol participants or take referrals. Contact the study team or a site listed below; they decide who can take part. This study is not recruiting at the moment.
Pamela C Petersen, M.D. principal investigator
Medical College of Wisconsin Affiliated Hospitals, Inc.
Sheila Hanson, M.D. principal investigator
Medical College of Wisconsin Affiliated Hospitals, Inc.
1 site in 1 country: see every site and its status.
Questions about this trial
What is this clinical trial studying?
An observational study of Healthy, run by Pamela Petersen at 1 site in United States.
The full registered description is in the About this study section and the official record.
Who may be eligible to take part?
The sponsor lists 1 inclusion and 1 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.
Is this clinical trial currently recruiting?
The record says: finished, as of the sponsor's last update on 24 Nov 2017. Status can change between updates, so confirm with the study contact before making plans.
Where is the study taking place?
The record lists 1 site in United States. Whether a site is taking part right now should be confirmed with that site. See every site.
What are the possible benefits and risks?
They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.
Are results available for this study?
The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.
How can a doctor refer a patient or contact the research team?
The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.
What does the primary outcome measure?
instances of alarm state corresponding to loss of signal integrity (time frame: 20 minutes). It is what the study was designed to measure, not a finding.
Where can I read the original study information?
On the ClinicalTrials.gov record for NCT03187665, which also lists 2 linked publications.