AzTrials
AzTrials

Respiratory Distress Syndrome in Premature InfantNCT03212508

Comparison of Two Nasal Interface for CPAP in Preterm

An observational study of Respiratory Distress Syndrome in Premature Infant, run by Dartmouth-Hitchcock Medical Center.

Completed

Finished. The study has ended and is not enrolling. Results may be posted on the official record.

Official record
Search all trials

Trial summary

Continuous distending airway pressure (CPAP) has gained popularity as a means to provide non-invasive respiratory support in neonates to reduce ventilator induced lung injury (VILI). Read more about this study

Who is it for?
Ages 48 hours to 52 weeks
What is being tested?
RAM cannula and Hudson prongs
Type of treatment
Medical device
How many people
12 participants
Where
No sites listed yet
Study dates
1 Aug 2016to 22 Mar 2017
Phase
Observational
Are there results?
None posted in the registry

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 48 hours to 52 weeks
  • All sexes
  • No healthy volunteers
  • Child

Study population: Any preterm with respiratory distress requiring CPAP

Who may be able to join

  • Any preterm with respiratory distress requiring CPAP but not mechanical ventilation or NIPPV will be eligible for the study. We will recruit preterm infant more than 48 hours old and stable on bubble CPAP

Who cannot join

  • Infants with major congenital anomalies, neuromuscular disorders, upper airway anomalies, critically sick infants

About this study

Official title: Comparison of Two Nasal Interface for Continuous Distending Airway Pressure in Preterm Infants: RAM Nasal Cannula and Hudson Prongs

Continuous distending airway pressure (CPAP) has gained popularity as a means to provide non-invasive respiratory support in neonates to reduce ventilator induced lung injury (VILI). However, maintaining CPAP in preterm infants has been challenging, often related to issues with nasal interface such as nasal septal injury, problems with keeping the prongs in the nose and leak around the prongs with are important factors in proving effective CPAP. RAM cannula was recently approved for providing supplemental oxygen and soon adapted by many centers to provide CPAP in preterm infants. Concerns have been raised that RAM cannula interface results in sub-optimal pressure delivery compared to standard nasal prongs.

Read the detailed description

Objective:

To compare efficacy of delivering continuous distending pressure in preterm neonates using RAM cannula versus the standard prongs (Hudson prongs) by measuring intra-oral pressure. It is hypothesize that CPAP delivered with RAM cannula is comparable to pressure delivered via standard nasal interface in routine clinical practice; and the desired CPAP level is often not achieved in presence of variable leak from mouth irrespective of type of nasal interface.

Aim 1: Compare the level of CPAP in oral cavity between RAM cannula and Hudson prong nasal interface in preterm Hypothesis: The intraoral pressure with CPAP will not be different with use of RAM cannula or Hudson prong nasal interface

Aim 2: Evaluate the effect of nasal interface (RAM cannula and Hudson prong) on respiratory variables Hypothesis: There will be no difference in respiratory variables with CPAP delivered by RAM cannula compared to Hudson prongs.

Method:

This was a single center prospective study. Inclusion criteria: Any preterm with respiratory distress requiring CPAP but not mechanical ventilation or NIPPV was eligible for the study. 12 preterm infant more than 48 hours old and stable on bubble CPAP were recruited for the study Exclusion criteria: Infants with major congenital anomalies, neuromuscular disorders, upper airway anomalies, critically sick infants

CPHS approval and parental consent was obtained prior to enrollment in the study.

Each infant was studied for ~1 hour during which the oral pressure was measured while receiving CPAP with RAM nasal cannula interface and then with Hudson prongs. Blinding of the intervention (nasal interface) was not feasible because of the visible differences in the two nasal interfaces.

Procedure: Intra-oral pressure measured via a differential pressure transducer while infant in receiving CPAP, and digitized data recorded with each nasal interface ( goal to record at least 20 sec of stable waveform on each nasal interface). Standard care provided during the study period and no changes made with CPAP level or flow.

The difference between set pressure and measured pressure with RAM cannula and Hudson prong was compared with standard paired student t-test with 95% confidence limits. Difference in other variables will be similarly compared with t-test. STAT 12 will be used for statistical analysis.

Being tested
RAM cannula and Hudson prongs
Keywords
Continuous positive airway pressure, preterm
Medical subject headings
Premature Birth

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • RAM cannula and Hudson prongsDevice

    Measuring intraoral pressure using two different nasal interface for applying nasal continuous positive airway pressure

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. The difference between set pressure and measured pressure with RAM cannula and Hudson prong

    Intraoral pressure measure using a differential pressure transducer with RAM cannula and then with Hudson prongs

    Measured: one hour

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted11 Jul 2017
  2. Study start1 Aug 2016
  3. Primary completion22 Mar 2017
  4. Study completion22 Mar 2017

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Observational
Observational model
Case crossover
Time perspective
Prospective
Enrolment
12 participants (actual)
IDs, dates and publications
ClinicalTrials.gov ID
NCT03212508
Sponsor's protocol ID
STUDY00029410
Status last verified
Jul 2023
First submitted
6 Jul 2017
Last updated
13 Jul 2023
Results posted
No
Data monitoring committee
No
FDA-regulated drug
No
FDA-regulated device
Yes
Individual data sharing
No

Publications

  • Singh N, McNally MJ, Darnall RA. Does the RAM Cannula Provide Continuous Positive Airway Pressure as Effectively as the Hudson Prongs in Preterm Neonates? Am J Perinatol. 2019 Jul;36(8):849-854. doi: 10.1055/s-0038-1675330. Epub 2018 Nov 5.

    PubMed 30396227

Questions about this trial

What is this clinical trial studying?

An observational study of Respiratory Distress Syndrome in Premature Infant, run by Dartmouth-Hitchcock Medical Center.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 1 inclusion and 1 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: finished, as of the sponsor's last update on 13 Jul 2023. Status can change between updates, so confirm with the study contact before making plans.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.

How can a doctor refer a patient or contact the research team?

The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

The difference between set pressure and measured pressure with RAM cannula and Hudson prong (time frame: one hour). It is what the study was designed to measure, not a finding.

Where can I read the original study information?

On the ClinicalTrials.gov record for NCT03212508, which also lists 1 linked publication.

Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 13 Jul 2023.

Free account

Log in to keep searching

You’ve used your 3 free searches. AzTrials is free: log in or create a free account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in