Trial summary

20 patients with distal humeral fractures (AO 13-A1 - AO 13-C3) were included in the current study since 2014. After completing the randomization plan, patients were distributed into two groups for different variable angle locking plates (DePuy Synthes VA-LCP vs. Medartis Aptus Elbow). Read more about this study

Who is it for?
Ages 18 to 95 years
Conditions the study is for
Distal Humerus Fracture
What is being tested?
Medartis and Synthes
Type of treatment
Surgery or procedure
Could I receive a placebo?
No, everyone receives an active treatment
How many people
20 participants
Where
No sites listed yet
Study dates
5 Feb 2014to 1 Jul 2017
Phase
Interventional
Are there results?
None posted in the registry

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 18 to 95 years
  • All sexes
  • No healthy volunteers
  • Adult, Older adult

Who may be able to join

  • The inclusion criteria involve all patients from the age of 18 to 95 years who suffered from a distal humeral fracture (AO 13-A1 - AO 13-C3) that had to undergo operative treatment

Who cannot join

  • The exclusion criteria involve all under-aged patients (< 18 years), pregnant patients and patients with a mental disorder as well as patients under comprehensive legal support. In addition, pathological fractures had been excluded from the study.

About this study

Official title: Polyaxial Locking Plates in Treating Distal Humeral Fractures: a Comparative Randomized Trial for Clinical Outcome

20 patients with distal humeral fractures (AO 13-A1 - AO 13-C3) were included in the current study since 2014. After completing the randomization plan, patients were distributed into two groups for different variable angle locking plates (DePuy Synthes VA-LCP vs. Medartis Aptus Elbow). Clinical and radiological follow-ups were conducted 6 weeks, 12 weeks, 6 months and 12 months after the operation.

Read the detailed description

Before study initiation the approval of the local ethics committee of (Trial Number 253/14) was obtained. The clinical trial included 20 patients with fractures of the distal humerus recruited from a level-one university trauma centre. Patient recruitment was conducted between 03/2014 and 12/2015. Fractures of the distal humerus, as defined by the AO classification system (AO 13-A1 - AO 13-C3), were included in this study as they were identified by the treating surgeon being applicable for locking plate treatment and after written informed consent of the patients was obtained. All patients were randomized following a randomization plan (Randlist, DatInf GmbH, Tübingen, Germany) for either being treated with the DePuy Synthes VA-LCP 2.7/3.5 mm (DePuy Synthes, Umkirch, Germany) or with the Medartis Aptus Elbow system 2.0/3.8 mm (Medartis, Basel, Switzerland). Both systems include anatomically preshaped, polyaxial angular stable locking plates in various sizes. Angle stable screw positioning with the freedom of +/- 15° off-axis screw placement gives the surgeon a large variety in both systems.

The inclusion criteria involve all patients from the age of 18 to 95 years who suffered from a distal humeral fracture (AO 13-A1 - AO 13-C3) that had to undergo operative treatment. The exclusion criteria involve all under-aged patients (< 18 years), pregnant patients and patients with a mental disorder as well as patients under comprehensive legal support. In addition, pathological fractures had been excluded from the study.

Surgical technique

All patients were operated by experienced upper extremity surgeons. The mean interval between injury and operation was 2.4 days (range 0-12 days). General anaesthesia was used in all cases and a single dose of 1.5 mg cephalosporin was given preoperatively for prophylaxis. Patients were positioned in prone position with the injured arm on a radiolucent, small padded arm holder. Under tourniquet control, the posterior approach (Bryan-Morrey) to the distal humerus was performed in all cases. Additional olecranon osteotomy was performed in 7 cases (3x DePuy Synthes vs. 4x Medartis Aptus Elbow) presenting with AO type 13 C2 and AO type 13 C3 fractures. Postoperatively, physiotherapy was initiated using the same rehabilitation protocol for both groups. Passive and active assisted ROM was permitted immediately without limitations, while weight bearing was restricted for 6 weeks.

Follow-up evaluation

All patients were initially followed-up 6 weeks after operation. Additional follow-ups were performed 3, 6 and 12 months postoperatively. The follow-up examinations were carried out by an independent investigator not involved in patient´s initial surgical treatment (MC). After the assessment of pain using the visual analogue scale (VAS) was documented, ROM and collateral ligament stability were documented on standardized scoring sheets. For subjective evaluation, patients rated their satisfaction for elbow use on a scale of 1 to 6 (1-highly satisfied; 2-satisfied; 3-moderate; 4-sufficient; 5-unsatisfied; 6-very unsatisfied). Moreover, sensomotoric disturbances and postoperative complications were recorded. For functional upper extremity and elbow scoring the shortened Disabilities of the Arm, Shoulder and Hand Score (QuickDASH) and the Mayo Elbow Performance Score (MEPS) were comprised. Postoperative x-rays were evaluated with special respect to bony healing, secondary loss of reduction and heterotopic ossifications.

Statistics

Statistical analyses were performed using the statistical software SigmaStat (version 3.5; Systat Software, San Jose, CA, USA). The scores at certain time points were compared with an independent t test after a normality check had been passed and equal variances had been detected. Normal distributed data with unequal variances would have been compared with Welch's t test. Arbitrarily data was tested with Mann-Whitney U test. The significance level was set at p= 0.05.

Being tested
Medartis, Synthes
Keywords
locking plate, anatomical preshaped, polyaxial, outcome
Medical subject headings
Humeral Fractures, Distal

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • MedartisProcedure or surgery

    Surgery using the medartis implant

  • SynthesProcedure or surgery

    Surgery using the Synthes implant

Study groups in NCT03272490
Study groupRoleWhat they receive
MedartisActive comparatorSurgery using the Medartis Implant
Receives: Procedure: Medartis
SynthesActive comparatorSurgery using the Synthes implant
Receives: Procedure: Synthes

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. Mayo Elbow Performance Score (MEPS)

    clinical and functional outcome

    Measured: 12 months

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted5 Sep 2017
  2. Study start5 Feb 2014
  3. Primary completion6 Jun 2017
  4. Study completion1 Jul 2017

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Interventional
Phase
Phase N/A
Primary purpose
Treatment
Allocation
Randomised
Intervention model
Parallel groups
Masking
Single blind
Who is masked
Participant
Enrolment
20 participants (actual)
IDs, dates and publications
ClinicalTrials.gov ID
NCT03272490
Sponsor's protocol ID
12345
Status last verified
Sep 2017
First submitted
31 Aug 2017
Last updated
5 Sep 2017
Results posted
No
Data monitoring committee
No
FDA-regulated drug
No
FDA-regulated device
No
Individual data sharing
No

Publications

  • Cronlein M, Lucke M, Beirer M, Pforringer D, Kirchhoff C, Biberthaler P, Braun KF, Siebenlist S. Polyaxial locking plates in treating distal humeral fractures: a comparative randomized trial for clinical outcome. BMC Musculoskelet Disord. 2017 Dec 28;18(1):547. doi: 10.1186/s12891-017-1910-9.

    PubMed 29282027

Questions about this trial

What is this clinical trial studying?

A study testing Medartis and Synthes in people with Distal Humerus Fracture, run by Technical University of Munich.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 1 inclusion and 1 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: finished, as of the sponsor's last update on 5 Sep 2017. Status can change between updates, so confirm with the study contact before making plans.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.

How can a doctor refer a patient or contact the research team?

The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

Mayo Elbow Performance Score (MEPS) (time frame: 12 months). It is what the study was designed to measure, not a finding.

Where can I read the original study information?

On the ClinicalTrials.gov record for NCT03272490, which also lists 1 linked publication.

Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 5 Sep 2017.

Free account

Log in to keep searching

You’ve used your 3 free searches. AzTrials is free: log in or create a free account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in