CataractNCT03280108
Clinical Investigation of AcrySof® IQ PanOptix™ IOL Model TFNT00
A study testing AcrySof IQ PanOptix Multifocal IOL and AcrySof Monofocal IOL in people with Cataract, run by Alcon Research at 12 sites in United States.
Trial summary
The purpose of this clinical study is to compare the visual outcomes of the AcrySof IQ PanOptix Multifocal Intraocular Lens (IOL) Model TFNT00 against that of a monofocal lens, the AcrySof Monofocal IOL Model SN60AT, in order to demonstrate comparable distance vision and superior near and intermediate vision. Read more about this study
- Who is it for?
- Ages 22 years and older
- Conditions the study is for
- Cataract
- What is being tested?
- AcrySof IQ PanOptix Multifocal IOL and AcrySof Monofocal IOL
- Type of treatment
- Medical device
- Could I receive a placebo?
- No, everyone receives an active treatment
- How many people
- 250 participants
- Where
- 12 sitesUnited States
- Study dates
- 1 Nov 2017to 27 Sep 2018
- Phase
- Interventional
- Are there results?
- Yes, posted in the registrySummary in the doctors' view
Key requirements
Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.
- Ages 22 years and older
- All sexes
- No healthy volunteers
- Adult, Older adult
Who may be able to join
- Diagnosed with bilateral cataracts with planned cataract removal by phacoemulsification with a clear cornea incision
- Able to comprehend and willing to sign informed consent and complete all required postoperative follow-up procedures
- Clear intraocular media other than cataract in both eyes.
- Preoperative keratometric astigmatism of less than 1.0 diopter (D) in both operative eyes.
Who cannot join
- Clinically significant corneal abnormalities including corneal dystrophy, irregularity, inflammation or edema
- Previous refractive surgery or refractive surgery procedures (including, but not limited to LASIK, astigmatic keratotomy, and limbal relaxing incisions)
- Glaucoma (uncontrolled or controlled with medication)
- Degenerative eye disorders (e.g. macular degeneration or other retinal disorders)
- Pregnant or lactating
- Expected to require a second surgical intervention or retinal laser treatment.
Trial locations and contacts
12 sites in 1 country.
12 sites in 1 country
United States12 sites
Alcon Investigative Site
Fresno, California, 93720
Alcon Investigative Site
Houston, Texas, 77027
Alcon Investigative Site
Hurst, Texas, 76054
Alcon Investigative Site
Mt. Dora, Florida, 32757
Alcon Investigative Site
Mt. Pleasant, South Carolina, 29464
Alcon Investigative Site
Nacogdoches, Texas, 75965
Alcon Investigative Site
Nashville, Tennessee, 37205
Alcon Investigative Site
Norfolk, Virginia, 23502
Alcon Investigative Site
Panama City, Florida, 32405
Alcon Investigative Site
Poughkeepsie, New York, 12603
Alcon Investigative Site
Salt Lake City, Utah, 84107
Alcon Investigative Site
Sioux Falls, South Dakota, 57108
About this study
The purpose of this clinical study is to compare the visual outcomes of the AcrySof IQ PanOptix Multifocal Intraocular Lens (IOL) Model TFNT00 against that of a monofocal lens, the AcrySof Monofocal IOL Model SN60AT, in order to demonstrate comparable distance vision and superior near and intermediate vision.
Read the detailed description
Both eyes of a subject must require cataract surgery to qualify for enrollment into this study. Subjects participating in the trial will attend a total of 10 study visits over a 7-month period. Of these 10 visits, 1 is preoperative, 2 are operative, and the remaining 7 are postoperative visits. Primary endpoint data will be collected at the Month 6 (Day 120-180) post second eye implantation visit.
- Conditions
- Cataract
- Being tested
- AcrySof IQ PanOptix Multifocal IOL, AcrySof Monofocal IOL
- Keywords
- Intraocular lens, IOL
- Medical subject headings
- Cataract
What participants receive
What participants receive. In a randomised study each person is assigned to one group by chance.
AcrySof IQ PanOptix Multifocal IOLDevice
Also called Model TFNT00, AcrySof® IQ PanOptix®
AcrySof IQ PanOptix Multifocal IOL Model TFNT00 for near, intermediate, and distance vision
AcrySof Monofocal IOLDevice
Also called Model SN60AT, AcrySof®
AcrySof Monofocal IOL Model SN60AT for single vision
| Study group | Role | What they receive |
|---|---|---|
| Multifocal IOL | Experimental | AcrySof IQ PanOptix Multifocal IOL Model TFNT00 implanted in the capsular bag in the posterior chamber following cataract removal and intended for long-term use over the lifetime of the cataract patient. Both eyes will be implanted (bilateral implantation). Receives: Device: AcrySof IQ PanOptix Multifocal IOL |
| Monofocal IOL | Active comparator | AcrySof Monofocal IOL Model SN60AT implanted in the capsular bag in the posterior chamber following cataract removal and intended for long-term use over the lifetime of the cataract patient. Both eyes will be implanted (bilateral implantation). Receives: Device: AcrySof Monofocal IOL |
What is being measured
The primary outcome is the main question the study is designed to answer.
Mean Photopic Monocular Best Corrected Distance Visual Acuity (4 m)
Visual acuity (VA) was tested monocularly (each eye separately) under photopic (well-lit) conditions using the correction obtained from the manifest refraction and 100% contrast electronic Early Treatment Diabetic Retinopathy Study (ETDRS) charts at a distance of 4 meters (m) from the eye. VA was measured in logarithm of the minimum angle of resolution (logMAR), with 0.02 logMAR increment corresponding to a single letter on an ETDRS chart. A lower numeric value represents better visual acuity. This analysis was prespecified for the first operative eye.
Measured: Month 6 (Day 120-180), post second eye implantation
Mean Photopic Monocular Distance Corrected Visual Acuity at Near (40 cm)
VA was tested monocularly under photopic conditions using the manifest refraction adjusted for optical infinity and 100% contrast electronic ETDRS charts at a distance of 40 centimeters (cm) from the eye. Distance corrected visual acuity at near was measured in logMAR, with 0.02 logMAR increment corresponding to a single letter on an ETDRS chart. A lower numeric value represents better visual acuity. This analysis was prespecified for the first operative eye.
Measured: Month 6 (Day 120-180), post second eye implantation
Cumulative Rate of Secondary Surgical Interventions (SSI) Related to Optical Properties of the IOL, First Eye
The number of SSI's related to the optical properties of the IOL was calculated from time of implantation up to Month 6. The percentage was calculated as (# of eyes with an SSI related to the optical properties of the IOL) divided by (# of eyes with attempted IOL implantation, successful or aborted after contact with the eye) times 100. SSI's could include, but were not limited to, IOL replacement, IOL explantation, IOL repositioning, refractive laser treatment, paracentesis, vitreous aspirations, iridectomy or laser iridotomy for pupillary block, wound leak repair, and retinal detachment repair. No hypothesis testing was planned for this outcome measure.
Measured: Up to Month 6 (Day 120-180), post second eye implantation
Mean Photopic Without Glare Binocular Distance Contrast Sensitivity
Contrast sensitivity (ie, the ability to detect objects by distinguishing them from their background) was assessed binocularly (both eyes together) with the subject's best spectacle correction under photopic (well-lit) conditions at a distance of 8 feet from the eye at spatial frequencies of 3, 6, and 12, and 18 cycles per degree (cpd) using the Vector Vision CSV 1000-HGT without a glare source. Raw scores from contrast sensitivity testing were transformed to log units. Subjects who were unable to see a targeted spatial frequency at any available contrast, including that of the reference patch, were assigned the lowest measurable value. A higher numeric value represents better contrast sensitivity. Hypothesis testing was not planned for this outcome measure.
Measured: Month 6 (Day 120-180), post second eye implantation
Mean Photopic With Glare Binocular Distance Contrast Sensitivity
Contrast sensitivity was assessed binocularly with the subject's best spectacle correction under photopic conditions at a distance of 8 feet from the eye at spatial frequencies of 3, 6, and 12, and 18 cpd using the Vector Vision CSV 1000-HGT with a glare source. Raw scores from contrast sensitivity testing were transformed to log units. Subjects who were unable to see a targeted spatial frequency at any available contrast, including that of the reference patch, were assigned the lowest measurable value. A higher numeric value represents better contrast sensitivity. Hypothesis testing was not planned for this outcome measure.
Measured: Month 6 (Day 120-180), post second eye implantation
Mean Mesopic Without Glare Binocular Distance Contrast Sensitivity
Contrast sensitivity was assessed binocularly with the subject's best spectacle correction under mesopic (dimly-lit) conditions at a distance of 8 feet from the eye at spatial frequencies of 1.5, 3, 6, and 12 cpd using the Vector Vision CSV 1000-HGT without a glare source. Raw scores from contrast sensitivity testing were transformed to log units. Subjects who were unable to see a targeted spatial frequency at any available contrast, including that of the reference patch, were assigned the lowest measurable value. A higher numeric value represents better contrast sensitivity. Hypothesis testing was not planned for this outcome measure.
Measured: Month 6 (Day 120-180), post second eye implantation
Mean Mesopic With Glare Binocular Distance Contrast Sensitivity
Contrast sensitivity was assessed binocularly with the subject's best spectacle correction under mesopic conditions at a distance of 8 feet from the eye at spatial frequencies of 1.5, 3, 6, and 12 cpd using the Vector Vision CSV 1000-HGT with a glare source. Raw scores from contrast sensitivity testing were transformed to log units. Subjects who were unable to see a targeted spatial frequency at any available contrast, including that of the reference patch, were assigned the lowest measurable value. A higher numeric value represents better contrast sensitivity. Hypothesis testing was not planned for this outcome measure.
Measured: Month 6 (Day 120-180), post second eye implantation
Secondary outcomes (4)
Mean Photopic Monocular Distance Corrected Visual Acuity at Intermediate (66 cm)
VA was tested monocularly under photopic conditions using the manifest refraction adjusted for optical infinity and 100% contrast electronic ETDRS charts at a distance of 66 cm m from the eye. Monocular distance corrected visual acuity at intermediate was measured in logMAR, with 0.02 logMAR increment corresponding to a single letter on an ETDRS chart. A lower numeric value represents better visual acuity. This analysis was prespecified for the first operative eye.
Measured: Month 6 (Day 120-180), post second eye implantation
Proportion of Subjects Who Respond "Never" to Question 1 of the Intraocular Lens Satisfaction (IOLSAT) Questionnaire
The IOLSAT is a patient-reported outcomes questionnaire. Subjects were asked, "Overall, in the past 7 days, how often did you need to wear eyeglasses to see?" The proportion of subjects who respond "Never" is reported as a percentage calculated as (# of subjects responding "Never") divided by (# of subjects with bilateral implantation and concordant, non-missing data) times 100.
Measured: Month 6 (Day 120-180), post second eye implantation
Rate of Severe Visual Disturbances as Reported by the Subject Using the Questionnaire for Visual Disturbances (QUVID)
QUVID is a patient-reported outcomes questionnaire that collects responses about visual disturbance. Subjects were asked if they experienced any of the visual disturbances in the past 7 days from when the questionnaire was conducted and to answer about how severe their worst experience was on a scale from 0-4, where 0=none and 4=severe. The percentage of subjects responding "Severe" was calculated as (# of subjects responding "Severe") divided by (# of subjects with bilateral implantation and non-missing data in the specified category) times 100. Hypothesis testing was not planned for this outcome measure.
Measured: Month 6 (Day 120-180), post second eye implantation
Rate of Most Bothersome Visual Disturbances as Reported by the Subject Using the QUVID
Subjects were asked if they experienced any of the visual disturbances in the past 7 days from when the questionnaire was conducted and to answer how much the disturbance bothered them on a scale from 0-4, where 0=not bothered at all and 4=bothered very much. The percentage of subjects with most bothersome visual disturbances was calculated as (# of subjects responding "Bothered very much") divided by (# of subjects with bilateral implantation and non-missing data in the specified category) times 100. Hypothesis testing was not planned for this outcome measure.
Measured: Month 6 (Day 120-180), post second eye implantation
Timeline
From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.
- First posted12 Sep 2017
- Study start1 Nov 2017
- Primary completion27 Sep 2018
- Study completion27 Sep 2018
Resources
- Official record on ClinicalTrials.govThe registry entry this page is built from, with its full change history.
- Posted resultsParticipant flow, outcome measures and adverse events reported by the sponsor.
- Other trials for CataractStudies of the same condition, open and under way.
- More trials run by Alcon ResearchThe sponsor's other registered studies.
- What the trial phases meanHow a treatment moves from first tests in people to approval.
More details
For doctors and researchers: how the study is designed, who runs it, and its registry IDs.
Study design
- Study type
- Interventional
- Phase
- Phase N/A
- Primary purpose
- Treatment
- Allocation
- Non-randomised
- Intervention model
- Parallel groups
- Masking
- Single blind
- Who is masked
- Outcomes assessor
- Enrolment
- 250 participants (actual)
Sponsor and investigators
- Lead sponsor
- Alcon Research
- Sponsor type
- Industry (pharma, biotech, devices)
- Responsible party
- Sponsor
- Investigators
- Alcon Research, Study director, Alcon Research
IDs, dates and publications
- ClinicalTrials.gov ID
- NCT03280108
- Sponsor's protocol ID
- ILH297-C001
- Status last verified
- Oct 2019
- First submitted
- 6 Sep 2017
- Last updated
- 10 Oct 2019
- Results posted
- Yes, on ClinicalTrials.gov
- FDA-regulated drug
- No
- FDA-regulated device
- Yes
- Individual data sharing
- No
Study at a glance
From the registry record, last updated by the sponsor on 10 Oct 2019. Recruitment status is as the sponsor reported it: confirm with the study team.
- Official title
- Clinical Investigation of AcrySof® IQ PanOptix™ IOL Model TFNT00
- ClinicalTrials.gov ID
- NCT03280108
- Acronym / sponsor ID
- ILH297-C001
- Conditions
- Cataract
- Keywords
- Intraocular lens, IOL
- Study type
- Interventional
- Recruitment status
- Completed
- Enrolment
- 250 participants (actual)
- Lead sponsor
- Alcon ResearchIndustry (pharma, biotech, devices)
- Study start
- 1 Nov 2017 (actual)
- Primary completion
- 27 Sep 2018 (actual)
- Study completion
- 27 Sep 2018 (actual)
- First posted
- 12 Sep 2017 (actual)
- Results
- Posted 10 Oct 2019
Clinical summary
The research question as the sponsor registered it. This describes what the study plans to test, not what it found.
The purpose of this clinical study is to compare the visual outcomes of the AcrySof IQ PanOptix Multifocal Intraocular Lens (IOL) Model TFNT00 against that of a monofocal lens, the AcrySof Monofocal IOL Model SN60AT, in order to demonstrate comparable distance vision and superior near and intermediate vision.
Detailed description
Both eyes of a subject must require cataract surgery to qualify for enrollment into this study. Subjects participating in the trial will attend a total of 10 study visits over a 7-month period. Of these 10 visits, 1 is preoperative, 2 are operative, and the remaining 7 are postoperative visits. Primary endpoint data will be collected at the Month 6 (Day 120-180) post second eye implantation visit.
Study design
- Primary purpose
- Treatment
- Allocation
- Non-randomised
- Intervention model
- Parallel groups
- Masking
- Single blind (outcomes assessor)
- Number of arms
- 2
| Arm | Type | Receives |
|---|---|---|
| Multifocal IOL | Experimental | Device: AcrySof IQ PanOptix Multifocal IOLAcrySof IQ PanOptix Multifocal IOL Model TFNT00 implanted in the capsular bag in the posterior chamber following cataract removal and intended for long-term use over the lifetime of the cataract patient. Both eyes will be implanted (bilateral implantation). |
| Monofocal IOL | Active comparator | Device: AcrySof Monofocal IOLAcrySof Monofocal IOL Model SN60AT implanted in the capsular bag in the posterior chamber following cataract removal and intended for long-term use over the lifetime of the cataract patient. Both eyes will be implanted (bilateral implantation). |
Who may qualify
- Ages
- 22 years and older
- Sex
- All
- Healthy volunteers
- Not accepted
- Age groups
- Adult, Older adult
Key inclusion criteria (4 listed)
- Diagnosed with bilateral cataracts with planned cataract removal by phacoemulsification with a clear cornea incision
- Able to comprehend and willing to sign informed consent and complete all required postoperative follow-up procedures
- Clear intraocular media other than cataract in both eyes.
- Preoperative keratometric astigmatism of less than 1.0 diopter (D) in both operative eyes.
Key exclusion criteria (6 listed)
- Clinically significant corneal abnormalities including corneal dystrophy, irregularity, inflammation or edema
- Previous refractive surgery or refractive surgery procedures (including, but not limited to LASIK, astigmatic keratotomy, and limbal relaxing incisions)
- Glaucoma (uncontrolled or controlled with medication)
- Degenerative eye disorders (e.g. macular degeneration or other retinal disorders)
- Pregnant or lactating
Eligibility is decided by the study team after screening; this overview does not establish that a patient qualifies. Full inclusion and exclusion criteria.
Interventions
| Intervention | Type | Arms |
|---|---|---|
| AcrySof IQ PanOptix Multifocal IOLAlso: Model TFNT00, AcrySof® IQ PanOptix®AcrySof IQ PanOptix Multifocal IOL Model TFNT00 for near, intermediate, and distance vision | Device | Multifocal IOL |
| AcrySof Monofocal IOLAlso: Model SN60AT, AcrySof®AcrySof Monofocal IOL Model SN60AT for single vision | Device | Monofocal IOL |
Primary outcome
Mean Photopic Monocular Best Corrected Distance Visual Acuity (4 m)
Time frame: Month 6 (Day 120-180), post second eye implantation
Visual acuity (VA) was tested monocularly (each eye separately) under photopic (well-lit) conditions using the correction obtained from the manifest refraction and 100% contrast electronic Early Treatment Diabetic Retinopathy Study (ETDRS) charts at a distance of 4 meters (m) from the eye. VA was measured in logarithm of the minimum angle of resolution (logMAR), with 0.02 logMAR increment corresponding to a single letter on an ETDRS chart. A lower numeric value represents better visual acuity. This analysis was prespecified for the first operative eye.
Mean Photopic Monocular Distance Corrected Visual Acuity at Near (40 cm)
Time frame: Month 6 (Day 120-180), post second eye implantation
VA was tested monocularly under photopic conditions using the manifest refraction adjusted for optical infinity and 100% contrast electronic ETDRS charts at a distance of 40 centimeters (cm) from the eye. Distance corrected visual acuity at near was measured in logMAR, with 0.02 logMAR increment corresponding to a single letter on an ETDRS chart. A lower numeric value represents better visual acuity. This analysis was prespecified for the first operative eye.
Cumulative Rate of Secondary Surgical Interventions (SSI) Related to Optical Properties of the IOL, First Eye
Time frame: Up to Month 6 (Day 120-180), post second eye implantation
The number of SSI's related to the optical properties of the IOL was calculated from time of implantation up to Month 6. The percentage was calculated as (# of eyes with an SSI related to the optical properties of the IOL) divided by (# of eyes with attempted IOL implantation, successful or aborted after contact with the eye) times 100. SSI's could include, but were not limited to, IOL replacement, IOL explantation, IOL repositioning, refractive laser treatment, paracentesis, vitreous aspirations, iridectomy or laser iridotomy for pupillary block, wound leak repair, and retinal detachment repair. No hypothesis testing was planned for this outcome measure.
Mean Photopic Without Glare Binocular Distance Contrast Sensitivity
Time frame: Month 6 (Day 120-180), post second eye implantation
Contrast sensitivity (ie, the ability to detect objects by distinguishing them from their background) was assessed binocularly (both eyes together) with the subject's best spectacle correction under photopic (well-lit) conditions at a distance of 8 feet from the eye at spatial frequencies of 3, 6, and 12, and 18 cycles per degree (cpd) using the Vector Vision CSV 1000-HGT without a glare source. Raw scores from contrast sensitivity testing were transformed to log units. Subjects who were unable to see a targeted spatial frequency at any available contrast, including that of the reference patch, were assigned the lowest measurable value. A higher numeric value represents better contrast sensitivity. Hypothesis testing was not planned for this outcome measure.
Mean Photopic With Glare Binocular Distance Contrast Sensitivity
Time frame: Month 6 (Day 120-180), post second eye implantation
Contrast sensitivity was assessed binocularly with the subject's best spectacle correction under photopic conditions at a distance of 8 feet from the eye at spatial frequencies of 3, 6, and 12, and 18 cpd using the Vector Vision CSV 1000-HGT with a glare source. Raw scores from contrast sensitivity testing were transformed to log units. Subjects who were unable to see a targeted spatial frequency at any available contrast, including that of the reference patch, were assigned the lowest measurable value. A higher numeric value represents better contrast sensitivity. Hypothesis testing was not planned for this outcome measure.
Mean Mesopic Without Glare Binocular Distance Contrast Sensitivity
Time frame: Month 6 (Day 120-180), post second eye implantation
Contrast sensitivity was assessed binocularly with the subject's best spectacle correction under mesopic (dimly-lit) conditions at a distance of 8 feet from the eye at spatial frequencies of 1.5, 3, 6, and 12 cpd using the Vector Vision CSV 1000-HGT without a glare source. Raw scores from contrast sensitivity testing were transformed to log units. Subjects who were unable to see a targeted spatial frequency at any available contrast, including that of the reference patch, were assigned the lowest measurable value. A higher numeric value represents better contrast sensitivity. Hypothesis testing was not planned for this outcome measure.
Mean Mesopic With Glare Binocular Distance Contrast Sensitivity
Time frame: Month 6 (Day 120-180), post second eye implantation
Contrast sensitivity was assessed binocularly with the subject's best spectacle correction under mesopic conditions at a distance of 8 feet from the eye at spatial frequencies of 1.5, 3, 6, and 12 cpd using the Vector Vision CSV 1000-HGT with a glare source. Raw scores from contrast sensitivity testing were transformed to log units. Subjects who were unable to see a targeted spatial frequency at any available contrast, including that of the reference patch, were assigned the lowest measurable value. A higher numeric value represents better contrast sensitivity. Hypothesis testing was not planned for this outcome measure.
4 secondary outcomes
Mean Photopic Monocular Distance Corrected Visual Acuity at Intermediate (66 cm)
Time frame: Month 6 (Day 120-180), post second eye implantation
Proportion of Subjects Who Respond "Never" to Question 1 of the Intraocular Lens Satisfaction (IOLSAT) Questionnaire
Time frame: Month 6 (Day 120-180), post second eye implantation
Rate of Severe Visual Disturbances as Reported by the Subject Using the Questionnaire for Visual Disturbances (QUVID)
Time frame: Month 6 (Day 120-180), post second eye implantation
Rate of Most Bothersome Visual Disturbances as Reported by the Subject Using the QUVID
Time frame: Month 6 (Day 120-180), post second eye implantation
Results and safety
Loading the posted results from ClinicalTrials.gov…
Research links
- Official record on ClinicalTrials.govLast updated by the sponsor 10 Oct 2019.
- Posted resultsParticipant flow, baseline, all outcome measures and adverse events.
- Individual participant dataSharing planned: No
Related trials for Cataract
Recruiting
Implementing AI-based Glaucoma Screening Within Federally Qualified Health Centers
Glaucoma, Ocular Hypertension
Not yet recruiting
Trial to Investigate the Safety and Effectiveness of the KI-362-US1 (YP2.2VM) Intraocular Lens (IOL) in Adult Participants for Correction of Aphakia Following Cataract Extraction
Aphakia, Postcataract
Not yet recruiting
Effects of Oxygen Cage Support During Cataract Surgery
Cataract
Active, not recruitingObservational study
Age-Related Eye Disease Study (AREDS) Follow-Up
Age-Related Macular Degeneration, Cataract
RecruitingObservational study
Objective Depth-of-Focus Changes During Light Adjustable Lens UV Adjustments
Light Adjustable Lens, Objective Depth of Focus
Referral and contact
AzTrials does not enrol participants or take referrals. Contact the study team or a site listed below; they decide who can take part. This study is not recruiting at the moment.
Alcon Research study director
Alcon Research
12 sites in 1 country: see every site and its status.
Questions about this trial
What is this clinical trial studying?
A study testing AcrySof IQ PanOptix Multifocal IOL and AcrySof Monofocal IOL in people with Cataract, run by Alcon Research at 12 sites in United States.
The full registered description is in the About this study section and the official record.
Who may be eligible to take part?
The sponsor lists 4 inclusion and 6 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.
Is this clinical trial currently recruiting?
The record says: finished, as of the sponsor's last update on 10 Oct 2019. Status can change between updates, so confirm with the study contact before making plans.
Where is the study taking place?
The record lists 12 sites in United States. Whether a site is taking part right now should be confirmed with that site. See every site.
What are the possible benefits and risks?
They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.
Are results available for this study?
Yes. Results are posted in the registry (first posted 10 Oct 2019). A summary is in the For doctors view, and the full results are on ClinicalTrials.gov.
How can a doctor refer a patient or contact the research team?
The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.
What does the primary outcome measure?
Mean Photopic Monocular Best Corrected Distance Visual Acuity (4 m) (time frame: Month 6 (Day 120-180), post second eye implantation). The study lists 7 primary outcomes in all. It is what the study was designed to measure, not a finding.