The Role of Circuit Flow During Mechanical Ventilation of Neonates

A study testing SIPPV_VG_0_08, SIPPV_VG_0_16 and SIPPV_VG_0_24 in people with Respiratory Distress Syndrome in Premature Infant, run by Cambridge University Hospitals NHS Foundation Trust at 1 site in United Kingdom.

Completed

Finished. The study has ended and is not enrolling. Results may be posted on the official record.

Official record
Search all trials

Trial summary

During neonatal mechanical ventilation inflating pressures, tidal volumes, and inflation and expiration times need to be set and adjusted to optimise oxygenation and carbon dioxide removal. Read more about this study

Who is it for?
Ages 1 day to 2 months
What is being tested?
SIPPV_VG_0_08, SIPPV_VG_0_16 and SIPPV_VG_0_24
Type of treatment
Medical device
Could I receive a placebo?
No, everyone receives an active treatment
How many people
12 participants
Where
1 siteUnited Kingdom
Study dates
1 Jul 2017to 30 Jun 2018
Phase
Interventional
Are there results?
None posted in the registry

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 1 day to 2 months
  • All sexes
  • No healthy volunteers
  • Child

Who may be able to join

  • Birth weight < 2 kg;
  • Ventilated with SIPPV-VG modes,
  • Informed parental consent,
  • Clinician assent.

Who cannot join

  • Baby's respiratory condition unstable (Inspired oxygen (FiO2) > 50%, PaCO2 > 8.5kPa or <5kPa in the last 12 hours)
  • Extubation planned in the next 12 hours;
  • Neonatal or surgical procedure in the last 12 hours or planned in the next 12 hours;
  • Significant pneumothorax requiring drainage;
  • Gas leak around the endotracheal tube >50%; #
  • No arterial access;
  • The responsible clinician does not agree with recruitment;
  • Parents do not consent.

Trial locations and contacts

1 site in 1 country.

United Kingdom1 site
  • Neonatal Intensive Care Unit, Cambridge University Hospitals NHS Trust

    Cambridge, CB20QQ

Other trials in United Kingdom

About this study

Official title: Investigating the Effect of Altering the Slope of the Rise in Pressure During Mechanical Ventilation of Preterm Babies

During neonatal mechanical ventilation inflating pressures, tidal volumes, and inflation and expiration times need to be set and adjusted to optimise oxygenation and carbon dioxide removal. The flow of gas into the ventilator circuit has a big effect on ventilation but is usually set to a constant value (~8 L/min) for all babies regardless of size or severity of illness, based on minimal research. High circuit flow may lead to lung damage and low flow to inadequate ventilation. The investigators recently developed a unique system to capture, record, analyse, and display ventilator data at high resolution over long periods. Using this the investigators will investigate, in within patient cross-over studies, how the level of gas flow affects ventilator parameters and ventilation, in two commonly used ventilation modes. The results will determine the lowest circuit flow that ventilates a baby safely and effectively. It will also provide preliminary data for a randomised trial.

Read the detailed description
  • Background of the project

About 1.5% of newborns require mechanical ventilation. Although mechanical ventilation can be life-saving for neonates with respiratory failure, it may cause lung injury due to excess airway pressure (barotrauma), delivery of high tidal volumes (volutrauma) and repetitive closing/re-opening of lung units (atelectotrauma)1. Very preterm neonates are especially vulnerable to ventilator induced lung injury. Ventilator associated lung injury is one of several factors contributing to the burden of chronic lung disease of infancy, also called bronchopulmonary dysplasia (BPD).

Ventilators have several different modes. The most frequently used mode is, time-cycled, pressure limited, where the doctor sets inspired oxygen level, the peak inflation pressure (PIP), rate, and inflation time of the ventilator. In this mode the inflations are usually synchronised with the baby's breathing. This is either Synchronised Intermittent Positive Pressure Ventilation (SIPPV), where the ventilator synchronises inflations with all the baby's breaths, or Synchronised Intermittent Mandatory Ventilation (SIMV), where the ventilator only synchronises with a set number of breaths. These can be delivered with or without targeting the tidal volume delivered to a set value by adjusting the peak inflating pressure. This mode is called volume guarantee (VG). A similar mode of ventilation is flow-cycled or Pressure Support Ventilation (PSV) and can be combined with tidal volume targeting 2. In this mode the inflation is terminated as soon as the flow rate falls to 15% of the maximum flow during inflation.

These modes have continuous gas flow through the ventilation circuit. Inflation starts and pressure rises when the expiratory valve is closed. The rate of circuit flow alters the ventilation waveforms. With time-cycled ventilation the higher the circuit flow the faster the pressure rises, the lung is distended and potentially injured, and the earlier the set PIP is achieved. A high flow, with a relatively long inflation time will result in a "pressure plateau", that is the PIP is sustained after the flow, into the baby, has stopped because the lung volume is maximal at the PIP used (Figure 1). In PSV inflation stops when the flow has decreased to ~15% of the peak inflation flow and so the inflation time is shorter. Increasing the device flow shortens the inflation time and thereby reduces the mean airway pressure.

Despite the effects on ventilation patterns and the speed of lung distension and injury, consideration has rarely been given to the circuit flow. By protocol, it is usually set at 7-10 L/min when the ventilator is turned on and it is not changed.

This is relatively high, and usually produces a "square" pressure waveform with a rapid distention of the lungs and a sustained pressure plateau. (see A in figure 1) With PSV a high flow results in a relatively short inflation time (~0.2 sec; it needs to be at least 0.3 sec for adequate lung aeration). There is no evidence these high flows are best for optimum ventilation and minimum lung damage. In a preterm lamb model there were no adverse effects on gas exchange or cardiovascular parameters until the flow was reduced to 3 l/min 3. In animal studies ventilation with high flow resulted in histologic and molecular changes of lung injury 4. The effect of lowering the ventilator circuit flow rate has never been investigated in clinical studies.

The Dräger Babylog VN500 ventilator has an alternative to setting a gas flow: the user can set the slope time instead, that is time required to reach the set pressure. In Cambridge it is invariably set to 0.08 sec which results in a flow ~7 L/min. As we use an inflation time between 0.33 - 0.45 sec, there is a pressure plateau lasting at least 0.25 sec and sustained inflation with little or no flow.

The investigators are the first to develop a unique system for downloading and analysing data from the Dräger VN500 neonatal ventilator. Using DataGrabber software obtained from Dräger Medical, the investigators can retrieve ventilator parameters at 100Hz frequency over long periods (hours and even days). To analyse and visualise the large datasets the investigators developed a data analysis workflow using the Python programing language and its add-on packages (Figure 2). With this tool the investigators can now study details of each inflation and spontaneous breath. The Investigators have recorded detailed data from 30 babies and shown it is feasible, accurate, and the investigators have the expertise (Belteki et al, submitted).

In this application the investigators propose to investigate the effect of different slope times (and therefore different levels of circuit flow) on ventilation parameters and gas exchange in preterm infants. The investigators hypothesise that a longer slope time (= lower circuit flow) will distend the lungs more gently yet maintain ventilation and gas exchange.

  • Intervention:

The study is a within patient crossover design comparing short periods of ventilation with different slope times both in SIPPV-VG and PSV-VG modes with the following interventions:

A ventilator download tool and transcutaneous and expired CO2 monitors is attached to the ventilator and data download commences while the baby is ventilated with the parameters used by the clinical team. An arterial blood gas is performed. The ventilated parameters are changed as shown below. The order of these epochs is randomised. Another arterial blood gas is performed. Ventilator is changed back to the original parameters (or different as appropriate by the blood gas). Ventilator data and CO2 recording will be continued for another 30 minutes.

Interventions

Duration Ventilator More Slope time Inspiratory time[max] 15 min SIPPV-VG 0.08 0.40 15 min PSV-VG 0.08 [0.60] 15 min PSV-VG 0.16 [0.60] 15 min SIPPV-VG 0.16 0.40 15 min SIPPV-VG 0.24 0.40 15 min PSV-VG 0.24 [0.60] 15 min PSV-VG 0.32 [0.60] 15 min SIPPV-VG 0.32 0.40 15 min SIPPV-VG 0.40 0.40 115 min PSV-VG 0.40 [0.60]

Total study duration is 220 minutes. A researcher will be present continuously. FiO2 will be adjusted if needed to maintain saturations between 90-95%. If the FiO2 rises >15% or the end-tidal CO2 rises >1.5kPa over the pre-study level, that intervention will be abandoned.

Comparison:

At each slope time, the following parameters will be determined and compared with those recorded at 0.08 sec slope time: (1) peak inflating pressure, (2) inflation duration, (3) duration of inflation plateau, (4) duration of no gas flow, (5) expired tidal and minute volumes (mandatory/spontaneous, inspiratory/expiratory, (6) ventilator rate, (7) FiO2, (8) transcutaneous and/or end-tidal CO2 and, (9) interaction between ventilator inflations and baby's breaths. Values for SIPPV and PSV will also be compared.

Being tested
SIPPV_VG_0_08, SIPPV_VG_0_16, SIPPV_VG_0_24, SIPPV_VG_0_32, SIPPV_VG_0_40
Keywords
mechanical ventilation, SIPPV, PSV, Device flow, Circuit flow, Slope time, neonatal intensive care

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • SIPPV_VG_0_08Device

    Mechanical ventilation using SIPPV-VG ventilator mode with a slope time of 0.08 seconds, inspiratory time of 0.40 seconds for 15 minutes

  • SIPPV_VG_0_16Device

    Mechanical ventilation using SIPPV-VG ventilator mode with a slope time of 0.16seconds, inspiratory time of 0.40 seconds for 15 minutes

  • SIPPV_VG_0_24Device

    Mechanical ventilation using SIPPV-VG ventilator mode with a slope time of 0.24 seconds, inspiratory time of 0.40 seconds for 15 minutes

  • SIPPV_VG_0_32Device

    Mechanical ventilation using SIPPV-VG ventilator mode with a slope time of 0.32 seconds, inspiratory time of 0.40 seconds for 15 minutes

  • SIPPV_VG_0_40Device

    Mechanical ventilation using SIPPV-VG ventilator mode with a slope time of 0.40 seconds, inspiratory time of 0.40 seconds for 15 minutes

  • PSV_VG_0_08Device

    Mechanical ventilation using PSV-VG ventilator mode with a slope time of 0.08 seconds, maximum inspiratory time of 0.60 seconds for 15 minutes

  • PSV_VG_0_16Device

    Mechanical ventilation using PSV-VG ventilator mode with a slope time of 0.16 seconds, maximum inspiratory time of 0.60 seconds for 15 minutes

  • PSV_VG_0_24Device

    Mechanical ventilation using PSV-VG ventilator mode with a slope time of 0.24 seconds, maximum inspiratory time of 0.60 seconds for 15 minutes

  • PSV_VG_0_32Device

    Mechanical ventilation using PSV-VG ventilator mode with a slope time of 0.32 seconds, maximum inspiratory time of 0.60 seconds for 15 minutes

  • PSV_VG_0_40Device

    Mechanical ventilation using PSV-VG ventilator mode with a slope time of 0.40 seconds, maximum inspiratory time of 0.60 seconds for 15 minutes

Study groups in NCT03306524
Study groupRoleWhat they receive
SIPPV_VG_0_08ExperimentalSIPPV VG ventilation for 15 minutes slope time = 0.08 seconds inspiratory time = 0.40 seconds
Receives: Device: SIPPV_VG_0_08
PSV_VG_0_08ExperimentalPSV VG ventilation for 15 minutes slope time = 0.08 seconds maximum inspiratory time = 0.60 seconds
Receives: Device: PSV_VG_0_08
SIPPV_VG_0_16ExperimentalSIPPV VG ventilation for 15 minutes slope time = 0.16 seconds inspiratory time = 0.40 seconds
Receives: Device: SIPPV_VG_0_16
PSV_VG_0_16ExperimentalPSV VG ventilation for 15 minutes slope time = 0.16 seconds maximum inspiratory time = 0.60 seconds
Receives: Device: PSV_VG_0_16
SIPPV_VG_0_24ExperimentalSIPPV VG ventilation for 15 minutes slope time = 0.24 seconds inspiratory time = 0.40 seconds
Receives: Device: SIPPV_VG_0_24
PSV_VG_0_24ExperimentalPSV VG ventilation for 15 minutes slope time = 0.24 seconds maximum inspiratory time = 0.60 seconds
Receives: Device: PSV_VG_0_24
SIPPV_VG_0_32ExperimentalSIPPV VG ventilation for 15 minutes slope time = 0.32 seconds inspiratory time = 0.40 seconds
Receives: Device: SIPPV_VG_0_32
PSV_VG_0_32ExperimentalPSV VG ventilation for 15 minutes slope time = 0.32 seconds maximum inspiratory time = 0.60 seconds
Receives: Device: PSV_VG_0_32
SIPPV_VG_0_40ExperimentalSIPPV VG ventilation for 15 minutes slope time = 0.32 seconds inspiratory time = 0.40 seconds
Receives: Device: SIPPV_VG_0_40
PSV_VG_0_40ExperimentalPSV VG ventilation for 15 minutes slope time = 0.40 seconds maximum inspiratory time = 0.60 seconds
Receives: Device: PSV_VG_0_40

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. End tidal CO2 measurement

    Primary outcome will be the difference in end-tidal CO2 concentration during the epochs with slope times of 0.40 and 0.08 sec.

    Measured: One year

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted11 Oct 2017
  2. Study start1 Jul 2017
  3. Primary completion30 Jun 2018
  4. Study completion30 Jun 2018

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Interventional
Phase
Phase N/A
Primary purpose
Treatment
Allocation
Randomised
Intervention model
Crossover
Model description
Ten different interventions (with changing slope time or ventilation mode) will be compared in a crossover design. Each intervention will be given for 15 minutes. For details of the intervention see study design details.
Masking
Single blind
Who is masked
Participant
Enrolment
12 participants (actual)
IDs, dates and publications
ClinicalTrials.gov ID
NCT03306524
Sponsor's protocol ID
16/28
Acronym
E-Flow
Status last verified
May 2019
First submitted
25 Sep 2017
Last updated
20 May 2019
Results posted
No
Data monitoring committee
No
FDA-regulated drug
No
FDA-regulated device
No
Individual data sharing
Undecided

Publications

  • Attar MA, Donn SM. Mechanisms of ventilator-induced lung injury in premature infants. Semin Neonatol. 2002 Oct;7(5):353-60. doi: 10.1053/siny.2002.0129.

    PubMed 12464497
  • Nafday SM, Green RS, Lin J, Brion LP, Ochshorn I, Holzman IR. Is there an advantage of using pressure support ventilation with volume guarantee in the initial management of premature infants with respiratory distress syndrome? A pilot study. J Perinatol. 2005 Mar;25(3):193-7. doi: 10.1038/sj.jp.7211233.

    PubMed 15674409
  • Bach KP, Kuschel CA, Oliver MH, Bloomfield FH. Ventilator gas flow rates affect inspiratory time and ventilator efficiency index in term lambs. Neonatology. 2009;96(4):259-64. doi: 10.1159/000220765. Epub 2009 May 27.

    PubMed 19478530
  • Bach KP, Kuschel CA, Hooper SB, Bertram J, McKnight S, Peachey SE, Zahra VA, Flecknoe SJ, Oliver MH, Wallace MJ, Bloomfield FH. High bias gas flows increase lung injury in the ventilated preterm lamb. PLoS One. 2012;7(10):e47044. doi: 10.1371/journal.pone.0047044. Epub 2012 Oct 8.

    PubMed 23056572

Questions about this trial

What is this clinical trial studying?

A study testing SIPPV_VG_0_08, SIPPV_VG_0_16 and SIPPV_VG_0_24 in people with Respiratory Distress Syndrome in Premature Infant, run by Cambridge University Hospitals NHS Foundation Trust at 1 site in United Kingdom.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 4 inclusion and 8 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: finished, as of the sponsor's last update on 20 May 2019. Status can change between updates, so confirm with the study contact before making plans.

Where is the study taking place?

The record lists 1 site in United Kingdom. Whether a site is taking part right now should be confirmed with that site. See every site.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.

How can a doctor refer a patient or contact the research team?

The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

End tidal CO2 measurement (time frame: One year). It is what the study was designed to measure, not a finding.

Where can I read the original study information?

On the ClinicalTrials.gov record for NCT03306524, which also lists 4 linked publications.

Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 20 May 2019.

Free account

Log in to keep searching

You’ve used your 3 free searches. AzTrials is free: log in or create a free account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in