CataractNCT03372434
Clinical Investigation of the Next-Generation Intraocular Lenses
A study testing Investigational Intraocular Lens Device #1: Model ZFR00, Investigational Intraocular Lens Device #1: Model ZYR00 and TECNIS Multifocal Intraocular Lens: Model ZLB00 in people with Cataract, run by Abbott Medical Optics at 12 sites in United States.
Trial summary
This study is a 6-month, prospective, multicenter, subject/evaluator-masked, bilateral, randomized clinical investigation of the TECNIS Next-Generation Model ZFR00 and Model ZYR00 IOLs versus the TECNIS Multifocal Model ZLB00 control IOL. Read more about this study
- Who is it for?
- Ages 22 years and olderHealthy volunteers can take part
- Conditions the study is for
- Cataract
- What is being tested?
- Investigational Intraocular Lens Device #1: Model ZFR00, Investigational Intraocular Lens Device #1: Model ZYR00 and TECNIS Multifocal Intraocular Lens: Model ZLB00
- Type of treatment
- Medical device
- Could I receive a placebo?
- No, everyone receives an active treatment
- How many people
- 225 participants
- Where
- 12 sitesUnited States
- Study dates
- 16 Jan 2018to 30 Oct 2018
- Phase
- Interventional
- Are there results?
- Yes, posted in the registrySummary in the doctors' view
Key requirements
Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.
- Ages 22 years and older
- All sexes
- Healthy volunteers accepted
- Adult, Older adult
Who may be able to join
- Minimum 22 years of age
- Bilateral cataracts for which posterior chamber IOL implantation has been planned
- Preoperative best corrected distance visual acuity (BCDVA) of 20/40 Snellen or worse with a glare source or 20/40 Snellen or worse without a glare source
- Potential for postoperative BCDVA of 20/30 Snellen or better
- Corneal astigmatism:
- Normal corneal topography
Show all 11Show fewer
- Preoperative corneal astigmatism of 1.00 D or less in both eyes
- Clear intraocular media other than cataract in each eye
- Availability, willingness and sufficient cognitive awareness to comply with examination procedures
- Signed informed consent and HIPAA authorization or equivalent documentation necessary to comply with applicable privacy laws pertaining to medical treatment in the governing countries
- Ability to understand and respond to a questionnaire in English
Who cannot join
- Requiring an intraocular lens power outside the available range of +14.0 D to +26.0 D
- Any clinically-significant pupil abnormalities (non-reactive, fixed pupils, or abnormally-shaped pupils)
- Irregular corneal astigmatism
- Inability to focus or fixate for prolonged periods of time (e.g., due to strabismus, nystagmus, etc.)
- Prior corneal refractive (LASIK, LASEK, RK, PRK, etc.) or intraocular surgery. Note: Prophylactic peripheral iridotomies and peripheral laser retinal repairs that, in the opinion of the investigator will not confound study outcome or increase risk to the subject, are acceptable.
- Corneal abnormalities such as stromal, epithelial or endothelial dystrophies that are predicted to cause visual acuity losses to a level worse than 20/30 Snellen during the study
Show all 21Show fewer
- Inability to achieve keratometric stability for contact lens wearers (per procedure outlined in Section 10.3)
- Recent ocular trauma or ocular surgery that is not resolved/stable or may affect visual outcomes or increase risk to the subject
- Subjects with diagnosed degenerative visual disorders (e.g., macular degeneration or other retinal disorders) that are predicted to cause visual acuity losses to a level worse than 20/30 Snellen during the study
- Subjects with conditions associated with increased risk of zonular rupture, including capsular or zonular abnormalities that may lead to IOL decentration or tilt, such as pseudoexfoliation, trauma, or posterior capsule defects
- Use of systemic or ocular medications that may affect vision
- Prior, current, or anticipated use during the course of the 6-month study of tamsulosin or silodosin (e.g., Flomax, Flomaxtra, Rapaflo) that may, in the opinion of the investigator, confound the outcome or increase the risk to the subject (e.g., poor dilation or a lack of adequate iris structure to perform standard cataract surgery)
- Poorly-controlled diabetes
- Acute, chronic, or uncontrolled systemic or ocular disease or illness that, in the opinion of the investigator, would increase the operative risk or confound the outcome(s) of the study (e.g., immunocompromised, connective tissue disease, suspected glaucoma, glaucomatous changes in the fundus or visual field, ocular inflammation, etc.). Note: controlled ocular hypertension without glaucomatous changes (optic nerve cupping and visual field loss) is acceptable.
- Known ocular disease or pathology that, in the opinion of the investigator,
- may affect visual acuity
- may require surgical intervention during the course of the study (macular degeneration, cystoid macular edema, diabetic retinopathy, uncontrolled glaucoma, etc.)
- may be expected to require retinal laser treatment or other surgical intervention during the course of the study (macular degeneration, cystoid macular edema, diabetic retinopathy, etc.)
- Patient is pregnant, plans to become pregnant, is lactating or has another condition associated with the fluctuation of hormones that could lead to refractive changes
- Concurrent participation or participation within 60 days prior to preoperative visit in any other clinical trial
- Desire for monovision correction
Trial locations and contacts
12 sites in 1 country.
12 sites in 1 country
United States12 sites
Chesapeake Eye Care & Laser Center
Annapolis, Maryland, 21401
Empire Eye & Laser Center
Bakersfield, California, 93309
Katzen Eye Care and Laser Center
Boynton Beach, Florida, 33426
Eye Doctors of Washington
Chevy Chase, Maryland, 20815
Scott & Christie and Associates, PC
Cranberry Township, Pennsylvania, 16066
Loden Vision Centers
Goodlettsville, Tennessee, 37072
Texas Eye and Laser Center
Hurst, Texas, 76054
Clarus Eye Centre
Lacey, Washington, 98503
Eye Specialty Group
Memphis, Tennessee, 38120
Carolina EyeCare Physicians, LLC
Mt. Pleasant, South Carolina, 29464
Lehmann Eye Center
Nacogdoches, Texas, 75965
Focal Point Vision
San Antonio, Texas, 78209
About this study
Official title: Clinical Investigation of the TECNIS Next-Generation Intraocular Lens
This study is a 6-month, prospective, multicenter, subject/evaluator-masked, bilateral, randomized clinical investigation of the TECNIS Next-Generation Model ZFR00 and Model ZYR00 IOLs versus the TECNIS Multifocal Model ZLB00 control IOL.
The study will be conducted at up to 14 sites in the U.S.A and will enroll up to 260 subjects to achieve approximately 220 randomized and bilaterally-implanted subjects, resulting in approximately 195 evaluable subjects (65 in each test group and 65 in the control group) at 1 and 6 months. Subjects are to be implanted with the same IOL in both eyes, the ZFR00 IOL, the ZYR00 IOL or the ZLB00 control IOL. The eye implanted first will be considered the primary study eye.
- Conditions
- Cataract
- Being tested
- Investigational Intraocular Lens Device #1: Model ZFR00, Investigational Intraocular Lens Device #1: Model ZYR00, TECNIS Multifocal Intraocular Lens: Model ZLB00
- Medical subject headings
- Cataract
What participants receive
What participants receive. In a randomised study each person is assigned to one group by chance.
Investigational Intraocular Lens Device #1: Model ZFR00Device
IOL replaces the natural lens removed during cataract surgery.
Investigational Intraocular Lens Device #1: Model ZYR00Device
IOL replaces the natural lens removed during cataract surgery.
TECNIS Multifocal Intraocular Lens: Model ZLB00Device
IOL replaces the natural lens removed during cataract surgery.
| Study group | Role | What they receive |
|---|---|---|
| Investigational Lens Device #1 | Experimental | Investigational Intraocular Lens Device #1: Model ZFR00 Receives: Device: Investigational Intraocular Lens Device #1: Model ZFR00 |
| Investigational Lens Device #2 | Experimental | Investigational Intraocular Lens Device #1: Model ZYR00 Receives: Device: Investigational Intraocular Lens Device #1: Model ZYR00 |
| Control Device | Active comparator | Control TECNIS Multifocal Intraocular Lens Model ZLB00 Receives: Device: TECNIS Multifocal Intraocular Lens: Model ZLB00 |
What is being measured
The primary outcome is the main question the study is designed to answer.
Distance Corrected Intermediate Visual Acuity
Visual Acuity (VA) was assessed monocularly (each eye separately) under photopic (well-lit) conditions using best distance correction (distance refraction) and high contrast, Early Treatment Diabetic Retinopathy Study (ETDRS) chart at 66 cm from spectacle plane. It was measured in logarithm of the minimum angle of resolution (logMAR), on an ETDRS chart. A lower numeric value represented better VA. This analysis was pre-specified for the first operative eye only.
Measured: 1 month
Timeline
From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.
- First posted13 Dec 2017
- Study start16 Jan 2018
- Primary completion11 Jul 2018
- Study completion30 Oct 2018
Resources
- Official record on ClinicalTrials.govThe registry entry this page is built from, with its full change history.
- Posted resultsParticipant flow, outcome measures and adverse events reported by the sponsor.
- Other trials for CataractStudies of the same condition, open and under way.
- What the trial phases meanHow a treatment moves from first tests in people to approval.
More details
For doctors and researchers: how the study is designed, who runs it, and its registry IDs.
Study design
- Study type
- Interventional
- Phase
- Phase N/A
- Primary purpose
- Treatment
- Allocation
- Randomised
- Intervention model
- Parallel groups
- Masking
- Double blind
- Who is masked
- Participant, Outcomes assessor
- Enrolment
- 225 participants (actual)
Sponsor and investigators
- Lead sponsor
- Abbott Medical Optics
- Sponsor type
- Industry (pharma, biotech, devices)
- Responsible party
- Sponsor
- Investigators
- Abbott Medical Optics Clinical Trials, Study director, Abbott Medical Optics
IDs, dates and publications
- ClinicalTrials.gov ID
- NCT03372434
- Sponsor's protocol ID
- SUR-CAT-652-1001
- Status last verified
- Jun 2025
- First submitted
- 8 Dec 2017
- Last updated
- 24 Jun 2025
- Results posted
- Yes, on ClinicalTrials.gov
- Data monitoring committee
- No
- FDA-regulated drug
- No
- FDA-regulated device
- Yes
- Individual data sharing
- No
Study at a glance
From the registry record, last updated by the sponsor on 24 Jun 2025. Recruitment status is as the sponsor reported it: confirm with the study team.
- Official title
- Clinical Investigation of the TECNIS Next-Generation Intraocular Lens
- ClinicalTrials.gov ID
- NCT03372434
- Acronym / sponsor ID
- SUR-CAT-652-1001
- Conditions
- Cataract
- Study type
- Interventional
- Recruitment status
- Completed
- Enrolment
- 225 participants (actual)
- Lead sponsor
- Abbott Medical OpticsIndustry (pharma, biotech, devices)
- Study start
- 16 Jan 2018 (actual)
- Primary completion
- 11 Jul 2018 (actual)
- Study completion
- 30 Oct 2018 (actual)
- First posted
- 13 Dec 2017 (actual)
- Results
- Posted 27 Jul 2021
Clinical summary
The research question as the sponsor registered it. This describes what the study plans to test, not what it found.
This study is a 6-month, prospective, multicenter, subject/evaluator-masked, bilateral, randomized clinical investigation of the TECNIS Next-Generation Model ZFR00 and Model ZYR00 IOLs versus the TECNIS Multifocal Model ZLB00 control IOL.
The study will be conducted at up to 14 sites in the U.S.A and will enroll up to 260 subjects to achieve approximately 220 randomized and bilaterally-implanted subjects, resulting in approximately 195 evaluable subjects (65 in each test group and 65 in the control group) at 1 and 6 months. Subjects are to be implanted with the same IOL in both eyes, the ZFR00 IOL, the ZYR00 IOL or the ZLB00 control IOL. The eye implanted first will be considered the primary study eye.
Study design
- Primary purpose
- Treatment
- Allocation
- Randomised
- Intervention model
- Parallel groups
- Masking
- Double blind (participant, outcomes assessor)
- Number of arms
- 3
| Arm | Type | Receives |
|---|---|---|
| Investigational Lens Device #1 | Experimental | Device: Investigational Intraocular Lens Device #1: Model ZFR00Investigational Intraocular Lens Device #1: Model ZFR00 |
| Investigational Lens Device #2 | Experimental | Device: Investigational Intraocular Lens Device #1: Model ZYR00Investigational Intraocular Lens Device #1: Model ZYR00 |
| Control Device | Active comparator | Device: TECNIS Multifocal Intraocular Lens: Model ZLB00Control TECNIS Multifocal Intraocular Lens Model ZLB00 |
Who may qualify
- Ages
- 22 years and older
- Sex
- All
- Healthy volunteers
- Accepted
- Age groups
- Adult, Older adult
Key inclusion criteria (11 listed)
- Minimum 22 years of age
- Bilateral cataracts for which posterior chamber IOL implantation has been planned
- Preoperative best corrected distance visual acuity (BCDVA) of 20/40 Snellen or worse with a glare source or 20/40 Snellen or worse without a glare source
- Potential for postoperative BCDVA of 20/30 Snellen or better
- Corneal astigmatism:
Key exclusion criteria (21 listed)
- Requiring an intraocular lens power outside the available range of +14.0 D to +26.0 D
- Any clinically-significant pupil abnormalities (non-reactive, fixed pupils, or abnormally-shaped pupils)
- Irregular corneal astigmatism
- Inability to focus or fixate for prolonged periods of time (e.g., due to strabismus, nystagmus, etc.)
- Prior corneal refractive (LASIK, LASEK, RK, PRK, etc.) or intraocular surgery. Note: Prophylactic peripheral iridotomies and peripheral laser retinal repairs that, in the opinion of the investigator will not confound study outcome or increase risk to the subject, are acceptable.
Eligibility is decided by the study team after screening; this overview does not establish that a patient qualifies. Full inclusion and exclusion criteria.
Interventions
| Intervention | Type | Arms |
|---|---|---|
| Investigational Intraocular Lens Device #1: Model ZFR00IOL replaces the natural lens removed during cataract surgery. | Device | Investigational Lens Device #1 |
| Investigational Intraocular Lens Device #1: Model ZYR00IOL replaces the natural lens removed during cataract surgery. | Device | Investigational Lens Device #2 |
| TECNIS Multifocal Intraocular Lens: Model ZLB00IOL replaces the natural lens removed during cataract surgery. | Device | Control Device |
Primary outcome
Distance Corrected Intermediate Visual Acuity
Time frame: 1 month
Visual Acuity (VA) was assessed monocularly (each eye separately) under photopic (well-lit) conditions using best distance correction (distance refraction) and high contrast, Early Treatment Diabetic Retinopathy Study (ETDRS) chart at 66 cm from spectacle plane. It was measured in logarithm of the minimum angle of resolution (logMAR), on an ETDRS chart. A lower numeric value represented better VA. This analysis was pre-specified for the first operative eye only.
Results and safety
Loading the posted results from ClinicalTrials.gov…
Research links
- Official record on ClinicalTrials.govLast updated by the sponsor 24 Jun 2025.
- Posted resultsParticipant flow, baseline, all outcome measures and adverse events.
- Individual participant dataSharing planned: No
Related trials for Cataract
Recruiting
Implementing AI-based Glaucoma Screening Within Federally Qualified Health Centers
Glaucoma, Ocular Hypertension
Not yet recruiting
Trial to Investigate the Safety and Effectiveness of the KI-362-US1 (YP2.2VM) Intraocular Lens (IOL) in Adult Participants for Correction of Aphakia Following Cataract Extraction
Aphakia, Postcataract
Not yet recruiting
Effects of Oxygen Cage Support During Cataract Surgery
Cataract
Active, not recruitingObservational study
Age-Related Eye Disease Study (AREDS) Follow-Up
Age-Related Macular Degeneration, Cataract
RecruitingObservational study
Objective Depth-of-Focus Changes During Light Adjustable Lens UV Adjustments
Light Adjustable Lens, Objective Depth of Focus
Referral and contact
AzTrials does not enrol participants or take referrals. Contact the study team or a site listed below; they decide who can take part. This study is not recruiting at the moment.
Abbott Medical Optics Clinical Trials study director
Abbott Medical Optics
12 sites in 1 country: see every site and its status.
Questions about this trial
What is this clinical trial studying?
A study testing Investigational Intraocular Lens Device #1: Model ZFR00, Investigational Intraocular Lens Device #1: Model ZYR00 and TECNIS Multifocal Intraocular Lens: Model ZLB00 in people with Cataract, run by Abbott Medical Optics at 12 sites in United States.
The full registered description is in the About this study section and the official record.
Who may be eligible to take part?
The sponsor lists 11 inclusion and 21 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.
Is this clinical trial currently recruiting?
The record says: finished, as of the sponsor's last update on 24 Jun 2025. Status can change between updates, so confirm with the study contact before making plans.
Where is the study taking place?
The record lists 12 sites in United States. Whether a site is taking part right now should be confirmed with that site. See every site.
What are the possible benefits and risks?
They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.
Are results available for this study?
Yes. Results are posted in the registry (first posted 27 Jul 2021). A summary is in the For doctors view, and the full results are on ClinicalTrials.gov.
How can a doctor refer a patient or contact the research team?
The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.
What does the primary outcome measure?
Distance Corrected Intermediate Visual Acuity (time frame: 1 month). It is what the study was designed to measure, not a finding.
Where can I read the original study information?
Does a listing mean the treatment is approved or proven to work?
No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.
How often is this information updated?
AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 24 Jun 2025.