Heart Defects, CongenitalNCT03441971
Evaluation of the GORE PV1 Device in Patients With Pulmonary Valve Dysfunction
A study testing GORE PV1 in people with Heart Defects, Congenital and Tetralogy of Fallot, run by W.L.Gore & Associates at 3 sites in United States.
Trial summary
This study will assess the safety and performance of the GORE PV1 Device for replacement of the pulmonary valve and reconstruction of the Right Ventricular Outflow Tract (RVOT). Read more about this study
- Who is it for?
- Ages 5 years and older
- Conditions the study is for
- Heart Defects, Congenital, Tetralogy of Fallot, Pulmonary Valve Insufficiency
- What is being tested?
- GORE PV1
- Type of treatment
- Medical device
- Could I receive a placebo?
- No, everyone receives an active treatment
- How many people
- 15 participants
- Where
- 3 sitesUnited States
- Study dates
- 7 Jun 2018to Mar 2030
- Phase
- Interventional
- Are there results?
- Not yet: the study is under way
Key requirements
Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.
- Ages 5 years and older
- All sexes
- No healthy volunteers
- Child, Adult, Older adult
Who may be able to join
- A symptomatic or appropriate asymptomatic subject with a native or repaired right ventricular outflow tract requiring reconstruction with a valved conduit
- Age ≥5 years at the time of informed consent signature.
- Note: Additional Inclusion Criteria may apply
Who cannot join
- An artificial valve at another position or will need an artificial valve at another position (i.e. replacement at the time of index procedure or anticipated within 3 years).
- Subjects with previously implanted pacemaker (including defibrillators).
- Major or progressive non-cardiac disease (liver failure, renal failure, cancer) that has a life expectancy of less than one year.
- Note: Additional Exclusion Criteria may apply
Trial locations and contacts
3 sites in 1 country.
United States3 sites
Boston Children's Hospital
Boston, Massachusetts, 02115
Lurie Children's Hospital
Chicago, Illinois, 60611
Nationwide Children's Hospital
Columbus, Ohio, 43205
About this study
Official title: Evaluation of the GORE PV1 Device for Replacement of the Pulmonary Valve and Reconstruction of Right Ventricular Outflow Tract
This study will assess the safety and performance of the GORE PV1 Device for replacement of the pulmonary valve and reconstruction of the Right Ventricular Outflow Tract (RVOT).
- Conditions
- Heart Defects, Congenital, Tetralogy of Fallot, Pulmonary Valve Insufficiency, Pulmonary Valve Stenosis
- Being tested
- GORE PV1
- Medical subject headings
- Heart Defects, Congenital, Tetralogy of Fallot, Pulmonary Valve Insufficiency, Pulmonary Valve Stenosis
What participants receive
What participants receive. In a randomised study each person is assigned to one group by chance.
GORE PV1Device
Implantation of GORE PV1 Device for procedure to replace the pulmonary valve and reconstruct the right ventricular outflow tract (RVOT).
| Study group | Role | What they receive |
|---|---|---|
| Single Arm | Experimental | Participants will receive the device on Day 1. Receives: Device: GORE PV1 |
What is being measured
The primary outcome is the main question the study is designed to answer.
Valve-related mortality and device-related re-intervention
The composite of valve-related mortality and device-related re-intervention measured at 6 months post-procedure
Measured: 6 months
Secondary outcomes (14)
MRI change in right ventricular end diastolic volume index
Six month change from baseline in right ventricular end diastolic volume index as measured from Magnetic Resonance Imaging
Measured: 6 months
MRI change in right ventricular end systolic volume index at 6 months
Six month change from baseline in right ventricular end systolic volume index as measured from Magnetic Resonance Imaging
Measured: 6 months
MRI change in left ventricular diastolic volume index at 6 months
Six month change from baseline in left ventricular diastolic volume index as measured from Magnetic Resonance Imaging
Measured: 6 months
MRI change in right ventricular ejection fraction at 6 months
Six month change from baseline in right ventricular ejection fraction index as measured from Magnetic Resonance Imaging
Measured: 6 months
Echo change in right ventricular diastolic area at 12 months
Twelve month change from baseline in right ventricular diastolic area as measured from echocardiography
Measured: 12 months
Echo change in right ventricular systolic area at 12 months
Twelve month change from baseline in right ventricular systolic area as measured from echocardiography
Measured: 12 months
Echo change in left ventricular end diastolic volume index at 12 months
Twelve month change from baseline in left ventricular end diastolic volume index as measured from echocardiography
Measured: 12 months
Echo change in right ventricular fractional area change at 12 months
Twelve month change from baseline in right ventricular fractional area change as measured from echocardiography
Measured: 12 months
Six month mean pressure gradient <= 40 mmHG
Number of subjects with mean pressure gradient across conduit (RV to PA) less than or equal to 40 mmHg at 6 months
Measured: 6 months
Twelve month mean pressure gradient <= 40 mmHG
Number of subjects with mean pressure gradient across conduit (RV to PA) less than or equal to 40 mmHg at 12 months
Measured: 12 months
Six month pulmonary regurgitation < moderate
Number of subjects with pulmonary regurgitation less than moderate at 6 months
Measured: 6 months
Twelve month pulmonary regurgitation < moderate
Number of subjects with pulmonary regurgitation less than moderate at 12 months
Measured: 12 months
Device-related re-intervention at 1, 3, 6, 12, 24, 36, 48, and 60 months
Kaplan-Meier estimates of device-related re-intervention summarized at 1, 3, 6, 12 months, and annually through 5 years
Measured: 1, 3, 6, 12, 24, 36, 48, and 60 months
All-cause mortality at 1, 3, 6, 12, 24, 36, 48, and 60 months
Kaplan-Meier estimates of all-cause mortality summarized at 1, 3, 6, 12 months, and annually through 5 years
Measured: 1, 3, 6, 12, 24, 36, 48, and 60 months
Timeline
From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.
- First posted22 Feb 2018
- Study start7 Jun 2018
- Primary completion13 Apr 2020
- Study completionMar 2030 (estimated)
Resources
- Official record on ClinicalTrials.govThe registry entry this page is built from, with its full change history.
- Other trials for Heart Defects, CongenitalStudies of the same condition, open and under way.
- More trials run by W.L.Gore & AssociatesThe sponsor's other registered studies.
- What the trial phases meanHow a treatment moves from first tests in people to approval.
More details
For doctors and researchers: how the study is designed, who runs it, and its registry IDs.
Study design
- Study type
- Interventional
- Phase
- Phase N/A
- Primary purpose
- Device feasibility
- Allocation
- Not applicable
- Intervention model
- Single group
- Masking
- None (open label)
- Enrolment
- 15 participants (estimated)
Sponsor and investigators
- Lead sponsor
- W.L.Gore & Associates
- Sponsor type
- Industry (pharma, biotech, devices)
- Responsible party
- Sponsor
- Investigators
- Pedro del Nido, MD, Principal investigator, Boston Children's Hospital
IDs, dates and publications
- ClinicalTrials.gov ID
- NCT03441971
- Sponsor's protocol ID
- Gore PVC 17-02
- Status last verified
- Feb 2026
- First submitted
- 15 Feb 2018
- Last updated
- 5 Feb 2026
- Results posted
- No
- Data monitoring committee
- Yes
- FDA-regulated drug
- No
- FDA-regulated device
- Yes
- Individual data sharing
- No
Study at a glance
From the registry record, last updated by the sponsor on 5 Feb 2026. Recruitment status is as the sponsor reported it: confirm with the study team.
- Official title
- Evaluation of the GORE PV1 Device for Replacement of the Pulmonary Valve and Reconstruction of Right Ventricular Outflow Tract
- ClinicalTrials.gov ID
- NCT03441971
- Acronym / sponsor ID
- Gore PVC 17-02
- Conditions
- Heart Defects, Congenital, Tetralogy of Fallot, Pulmonary Valve Insufficiency, Pulmonary Valve Stenosis
- Study type
- Interventional
- Recruitment status
- Active, not recruiting
- Enrolment
- 15 participants (estimated)
- Lead sponsor
- W.L.Gore & AssociatesIndustry (pharma, biotech, devices)
- Study start
- 7 Jun 2018 (actual)
- Primary completion
- 13 Apr 2020 (actual)
- Study completion
- Mar 2030 (estimated)
- First posted
- 22 Feb 2018 (actual)
- Results
- Not posted in the source record
Clinical summary
The research question as the sponsor registered it. This describes what the study plans to test, not what it found.
This study will assess the safety and performance of the GORE PV1 Device for replacement of the pulmonary valve and reconstruction of the Right Ventricular Outflow Tract (RVOT).
Study design
- Primary purpose
- Device feasibility
- Allocation
- Not applicable
- Intervention model
- Single group
- Masking
- None (open label)
- Number of arms
- 1
| Arm | Type | Receives |
|---|---|---|
| Single Arm | Experimental | Device: GORE PV1Participants will receive the device on Day 1. |
Who may qualify
- Ages
- 5 years and older
- Sex
- All
- Healthy volunteers
- Not accepted
- Age groups
- Child, Adult, Older adult
Key inclusion criteria (3 listed)
- A symptomatic or appropriate asymptomatic subject with a native or repaired right ventricular outflow tract requiring reconstruction with a valved conduit
- Age ≥5 years at the time of informed consent signature.
- Note: Additional Inclusion Criteria may apply
Key exclusion criteria (4 listed)
- An artificial valve at another position or will need an artificial valve at another position (i.e. replacement at the time of index procedure or anticipated within 3 years).
- Subjects with previously implanted pacemaker (including defibrillators).
- Major or progressive non-cardiac disease (liver failure, renal failure, cancer) that has a life expectancy of less than one year.
- Note: Additional Exclusion Criteria may apply
Eligibility is decided by the study team after screening; this overview does not establish that a patient qualifies. Full inclusion and exclusion criteria.
Interventions
| Intervention | Type | Arms |
|---|---|---|
| GORE PV1Implantation of GORE PV1 Device for procedure to replace the pulmonary valve and reconstruct the right ventricular outflow tract (RVOT). | Device | Single Arm |
Primary outcome
Valve-related mortality and device-related re-intervention
Time frame: 6 months
The composite of valve-related mortality and device-related re-intervention measured at 6 months post-procedure
14 secondary outcomes
MRI change in right ventricular end diastolic volume index
Time frame: 6 months
MRI change in right ventricular end systolic volume index at 6 months
Time frame: 6 months
MRI change in left ventricular diastolic volume index at 6 months
Time frame: 6 months
MRI change in right ventricular ejection fraction at 6 months
Time frame: 6 months
Echo change in right ventricular diastolic area at 12 months
Time frame: 12 months
Echo change in right ventricular systolic area at 12 months
Time frame: 12 months
Echo change in left ventricular end diastolic volume index at 12 months
Time frame: 12 months
Echo change in right ventricular fractional area change at 12 months
Time frame: 12 months
Six month mean pressure gradient <= 40 mmHG
Time frame: 6 months
Twelve month mean pressure gradient <= 40 mmHG
Time frame: 12 months
Six month pulmonary regurgitation < moderate
Time frame: 6 months
Twelve month pulmonary regurgitation < moderate
Time frame: 12 months
Device-related re-intervention at 1, 3, 6, 12, 24, 36, 48, and 60 months
Time frame: 1, 3, 6, 12, 24, 36, 48, and 60 months
All-cause mortality at 1, 3, 6, 12, 24, 36, 48, and 60 months
Time frame: 1, 3, 6, 12, 24, 36, 48, and 60 months
Results and safety
This study is still under way. Results are not available in the source record yet.
Research links
- Official record on ClinicalTrials.govLast updated by the sponsor 5 Feb 2026.
- Individual participant dataSharing planned: No
Related trials for Heart Defects, Congenital
Not yet recruiting
Autologous Thymus Transplant in Children With Congenital Heart Disease: A Pilot Study
Congenital Heart Disease (CHD)
RecruitingPhase 1
A Study of SGT-212 Gene Therapy in Friedreich's Ataxia
Friedreich's Ataxia (FA)
RecruitingObservational study
The CACHE Study: Coronary Artery Care in HaEmophilia
Haemophilia, Cardiovascular Diseases
RecruitingObservational study
Essen Amyloidosis Registry
Amyloidosis; Systemic, Amyloidosis Cardiac
Not yet recruitingObservational study
Early Nutrition and Heart Structure and Function in Preterm Infants During the First Year of Life
Cardiac Abnormalities, Nutrient Intake
Referral and contact
AzTrials does not enrol participants or take referrals. Contact the study team or a site listed below; they decide who can take part. This study is not recruiting at the moment.
Pedro del Nido, MD principal investigator
Boston Children's Hospital
3 sites in 1 country: see every site and its status.
Questions about this trial
What is this clinical trial studying?
A study testing GORE PV1 in people with Heart Defects, Congenital and Tetralogy of Fallot, run by W.L.Gore & Associates at 3 sites in United States.
The full registered description is in the About this study section and the official record.
Who may be eligible to take part?
The sponsor lists 3 inclusion and 4 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.
Is this clinical trial currently recruiting?
The record says: under way, not looking for participants, as of the sponsor's last update on 5 Feb 2026. Status can change between updates, so confirm with the study contact before making plans.
Where is the study taking place?
The record lists 3 sites in United States. Whether a site is taking part right now should be confirmed with that site. See every site.
What are the possible benefits and risks?
They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.
Are results available for this study?
This study is still under way. Results are not available in the source record yet.
How can a doctor refer a patient or contact the research team?
The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.
What does the primary outcome measure?
Valve-related mortality and device-related re-intervention (time frame: 6 months). It is what the study was designed to measure, not a finding.
Where can I read the original study information?
Does a listing mean the treatment is approved or proven to work?
No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.
How often is this information updated?
AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 5 Feb 2026.