Portal HypertensionNCT03451149
Feasibility And Safety Of Transjugular Intrahepatic Portosystemic Shunt (TIPS) Creation Using A Radiofrequency Guidewire
A study testing Radiofrequency wire (Powerwire) in people with Portal Hypertension, run by Oregon Health and Science University at 1 site in United States.
Trial summary
A novel radiofrequency (RF) wire created by Baylis Medical (Montreal, CAN) is an FDA cleared device commonly used for percutaneous recanalization procedures. This wire has an active tip that delivers focused RF energy and has been applied for many procedures such as percutaneous transseptal left heart access… Read more about this study
- Who is it for?
- Ages 20 to 99 years
- Conditions the study is for
- Portal Hypertension
- What is being tested?
- Radiofrequency wire (Powerwire)
- Type of treatment
- Medical device
- Could I receive a placebo?
- No, everyone receives an active treatment
- How many people
- 10 participants
- Where
- 1 siteUnited States
- Study dates
- 25 Oct 2017to 29 Jan 2019
- Phase
- Interventional
- Are there results?
- None posted in the registry
Key requirements
Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.
- Ages 20 to 99 years
- All sexes
- No healthy volunteers
- Adult, Older adult
Who may be able to join
- Patients with cirrhosis and portal hypertension meeting at least one indication for elective TIPS creation including refractory ascites, acute variceal bleeding not responsive to endoscopic treatment, prevention of recurrent variceal bleeding, portal hypertensive gastropathy, hepatorenal syndrome, Budd-Chiari syndrome, hepatic hydrothorax, hepatic veno-occlusive disease, and hepatopulmonary syndrome.
- Patients who agree to undergo TIPS procedure and participate in this clinical study.
- Age over 20 years
Who cannot join
- Patients with a contraindication for TIPS including congestive heart failure, severe tricuspid regurgitation, severe pulmonary hypertension, uncontrolled systemic infection or sepsis and unrelieved biliary obstruction.
- Patients in whom intravascular ultrasound cannot be used because of venous occlusion.
- Decisionally impaired patients
- Need for emergent TIPS creation
Trial locations and contacts
1 site in 1 country.
About this study
Official title: Single-Arm, Single-Center, Pilot Study To Evaluate The Feasibility And Safety Of Transjugular Intrahepatic Portosystemic Shunt (TIPS) Creation For Portal Hypertension Using A Radiofrequency Guidewire With Intravascular Ultrasound Guidance
A novel radiofrequency (RF) wire created by Baylis Medical (Montreal, CAN) is an FDA cleared device commonly used for percutaneous recanalization procedures. This wire has an active tip that delivers focused RF energy and has been applied for many procedures such as percutaneous transseptal left heart access, recanalization of central vein occlusion, recanalization of arterial occlusion, and recanalization of bile duct occlusion. There has been no study investigating the use of the RF wire for TIPS creation in clinical practice with humans. Having promising results of an experimental feasibility investigation in swine, the investigators are seeking to assess the feasibility and safety of the RF wire to cut through tissue in the liver while creating TIPS in the clinical setting.
Read the detailed description
The transjugular intrahepatic portosystemic shunt procedure (TIPS), first described in 1969 by Rösch et al., has been widely used to treat the complications of portal hypertension such as recurrent variceal hemorrhage and refractory ascites.
In the TIPS procedure, an intrahepatic connection between a hepatic vein and a portal vein branch is created in order to reduce the portal venous pressure. A dedicated device developed for the TIPS procedure, the Rösch-Uchida Transjugular Liver Access Set (RUPS), is widely used for this procedure. The most challenging and time-consuming part of TIPS creation is puncturing the portal vein from the hepatic vein with a long needle trocar. Occasionally in cirrhotic livers, the trocar needle can deflect and not easily pass through the parenchyma. Needle deflection may lead to additional needle passes and potentially increase risk of inadvertent injury to the liver or extracapsular puncture. There is need, therefore, for a device that can easily penetrate dense liver tissue without creating significant trauma.
A novel radiofrequency (RF) wire created by Baylis Medical (Montreal, CAN) is an FDA cleared device commonly used for percutaneous recanalization procedures. This wire has an active tip that delivers focused RF energy and has been applied for many procedures such as percutaneous transseptal left heart access, recanalization of central vein occlusion, recanalization of arterial occlusion, and recanalization of bile duct occlusion.
The investigators have assessed the application of the RF wire for TIPS creation in a swine model. The investigators found that the use of this wire to cut through tissue during TIPS creation is feasible in swine with some potential advantages compared with the current available tools. The RF wire device was well visualized under intravascular ultrasound (IVUS) guidance and could penetrate through the liver parenchyma smoothly and safely. In addition, the RF wire was able to subsequently be used as a working wire to complete the procedure. Advantages in clinical practice with cirrhotic livers would be the relative ease of penetration into a hardened liver compared to the trocar needle, and the additional benefit of being able to use the device as a working wire to minimize the risk of catheter displacement and decrease procedure time.
There has been no study investigating the use of the RF wire for TIPS creation in clinical practice with humans. Having the promising results of the experimental investigation in swine, the investigators are seeking to assess the feasibility and safety of the RF wire to cut through tissue in the liver while creating TIPS in the clinical setting. It is anticipated that the proposed experimental technique using the RF wire would be at least as safe as the current standard technique. The wire diameter, 0.035 inches, is smaller than the traditionally used 0.038 inch needle trocar, and the deposition of RF energy is limited to the wire tip with minimal collateral damage. Risks of complications, such as puncturing unintended structures including the liver capsule, hepatic artery, gallbladder and biliary tree are anticipated to be at least as low as for the standard technique, estimated at about 3-4%. Moreover, these risks may be reduced even further in the experimental technique owing to the use of intravascular ultrasound guidance, enabling direct visualization of the puncture compared to the standard technique using landmarks and reference images under x-ray fluoroscopy.
- Conditions
- Portal Hypertension
- Being tested
- Radiofrequency wire (Powerwire)
- Keywords
- TIPS
- Medical subject headings
- Hypertension, Portal
What participants receive
What participants receive. In a randomised study each person is assigned to one group by chance.
Radiofrequency wire (Powerwire)Device
Using a radiofrequency wire in lieu of a needle for penetrating the liver during transjugular intrahepatic portosystemic shunt creation.
| Study group | Role | What they receive |
|---|---|---|
| Intervention | Experimental | Undergo transjugular intrahepatic portosystemic shunt creation using a radiofrequency wire (Powerwire) in lieu of a trocar needle to cut through liver parenchyma Receives: Device: Radiofrequency wire (Powerwire) |
What is being measured
The primary outcome is the main question the study is designed to answer.
Feasibility to use the device as anticipated
Ability of the device to perform as anticipated
Measured: within 24 hours
Incidence of device-related adverse events (Safety)
No device-related adverse events
Measured: within 24 hours
Secondary outcomes (2)
Penetrating ability
To assess the capability of the RF wire to cut through tissue without significant deflection through parenchyma
Measured: within 24 hours
Device use as a standard working wire
To assess the capability of the RF wire to act as the working wire for delivery of the TIPS set into the portal vein after access.
Measured: within 24 hours
Timeline
From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.
- First posted1 Mar 2018
- Study start25 Oct 2017
- Primary completion29 Jan 2019
- Study completion29 Jan 2019
Resources
- Official record on ClinicalTrials.govThe registry entry this page is built from, with its full change history.
- Other trials for Portal HypertensionStudies of the same condition, open and under way.
- More trials run by Oregon Health and Science UniversityThe sponsor's other registered studies.
- What the trial phases meanHow a treatment moves from first tests in people to approval.
More details
For doctors and researchers: how the study is designed, who runs it, and its registry IDs.
Study design
- Study type
- Interventional
- Phase
- Phase N/A
- Primary purpose
- Device feasibility
- Allocation
- Not applicable
- Intervention model
- Single group
- Model description
- A single group of up to 10 participants will be enrolled to evaluate a radiofrequency wire for cutting through liver parenchyma instead of the standard trocar needle during transjugular intrahepatic portosystemic shunt creation. This will be to test this device for feasibility and not health outcomes.
- Masking
- None (open label)
- Enrolment
- 10 participants (actual)
Sponsor and investigators
- Lead sponsor
- Oregon Health and Science University
- Sponsor type
- University, hospital or other
- Collaborators
- Baylis Medical Company
- Responsible party
- Principal investigator, Khashayar Farsad, Oregon Health and Science University
- Investigators
- Khashayar Farsad, MD, Principal investigator, Oregon Health and Science University
IDs, dates and publications
- ClinicalTrials.gov ID
- NCT03451149
- Sponsor's protocol ID
- OHSU eIRB # 16296
- Status last verified
- Nov 2023
- First submitted
- 16 Feb 2018
- Last updated
- 3 Nov 2023
- Results posted
- No
- Data monitoring committee
- Yes
- FDA-regulated drug
- No
- FDA-regulated device
- Yes
- Individual data sharing
- Yes: HIPAA compliant, IRB-approved, non-identifiable information may be provided for research outcomes purposes.
Study at a glance
From the registry record, last updated by the sponsor on 3 Nov 2023. Recruitment status is as the sponsor reported it: confirm with the study team.
- Official title
- Single-Arm, Single-Center, Pilot Study To Evaluate The Feasibility And Safety Of Transjugular Intrahepatic Portosystemic Shunt (TIPS) Creation For Portal Hypertension Using A Radiofrequency Guidewire With Intravascular Ultrasound Guidance
- ClinicalTrials.gov ID
- NCT03451149
- Acronym / sponsor ID
- OHSU eIRB # 16296
- Conditions
- Portal Hypertension
- Keywords
- TIPS
- Study type
- Interventional
- Recruitment status
- Completed
- Enrolment
- 10 participants (actual)
- Lead sponsor
- Oregon Health and Science UniversityUniversity, hospital or other
- Collaborators
- Baylis Medical Company
- Study start
- 25 Oct 2017 (actual)
- Primary completion
- 29 Jan 2019 (actual)
- Study completion
- 29 Jan 2019 (actual)
- First posted
- 1 Mar 2018 (actual)
- Results
- Not posted in the source record
Clinical summary
The research question as the sponsor registered it. This describes what the study plans to test, not what it found.
A novel radiofrequency (RF) wire created by Baylis Medical (Montreal, CAN) is an FDA cleared device commonly used for percutaneous recanalization procedures. This wire has an active tip that delivers focused RF energy and has been applied for many procedures such as percutaneous transseptal left heart access, recanalization of central vein occlusion, recanalization of arterial occlusion, and recanalization of bile duct occlusion. There has been no study investigating the use of the RF wire for TIPS creation in clinical practice with humans. Having promising results of an experimental feasibility investigation in swine, the investigators are seeking to assess the feasibility and safety of the RF wire to cut through tissue in the liver while creating TIPS in the clinical setting.
Detailed description
The transjugular intrahepatic portosystemic shunt procedure (TIPS), first described in 1969 by Rösch et al., has been widely used to treat the complications of portal hypertension such as recurrent variceal hemorrhage and refractory ascites.
In the TIPS procedure, an intrahepatic connection between a hepatic vein and a portal vein branch is created in order to reduce the portal venous pressure. A dedicated device developed for the TIPS procedure, the Rösch-Uchida Transjugular Liver Access Set (RUPS), is widely used for this procedure. The most challenging and time-consuming part of TIPS creation is puncturing the portal vein from the hepatic vein with a long needle trocar. Occasionally in cirrhotic livers, the trocar needle can deflect and not easily pass through the parenchyma. Needle deflection may lead to additional needle passes and potentially increase risk of inadvertent injury to the liver or extracapsular puncture. There is need, therefore, for a device that can easily penetrate dense liver tissue without creating significant trauma.
A novel radiofrequency (RF) wire created by Baylis Medical (Montreal, CAN) is an FDA cleared device commonly used for percutaneous recanalization procedures. This wire has an active tip that delivers focused RF energy and has been applied for many procedures such as percutaneous transseptal left heart access, recanalization of central vein occlusion, recanalization of arterial occlusion, and recanalization of bile duct occlusion.
The investigators have assessed the application of the RF wire for TIPS creation in a swine model. The investigators found that the use of this wire to cut through tissue during TIPS creation is feasible in swine with some potential advantages compared with the current available tools. The RF wire device was well visualized under intravascular ultrasound (IVUS) guidance and could penetrate through the liver parenchyma smoothly and safely. In addition, the RF wire was able to subsequently be used as a working wire to complete the procedure. Advantages in clinical practice with cirrhotic livers would be the relative ease of penetration into a hardened liver compared to the trocar needle, and the additional benefit of being able to use the device as a working wire to minimize the risk of catheter displacement and decrease procedure time.
There has been no study investigating the use of the RF wire for TIPS creation in clinical practice with humans. Having the promising results of the experimental investigation in swine, the investigators are seeking to assess the feasibility and safety of the RF wire to cut through tissue in the liver while creating TIPS in the clinical setting. It is anticipated that the proposed experimental technique using the RF wire would be at least as safe as the current standard technique. The wire diameter, 0.035 inches, is smaller than the traditionally used 0.038 inch needle trocar, and the deposition of RF energy is limited to the wire tip with minimal collateral damage. Risks of complications, such as puncturing unintended structures including the liver capsule, hepatic artery, gallbladder and biliary tree are anticipated to be at least as low as for the standard technique, estimated at about 3-4%. Moreover, these risks may be reduced even further in the experimental technique owing to the use of intravascular ultrasound guidance, enabling direct visualization of the puncture compared to the standard technique using landmarks and reference images under x-ray fluoroscopy.
Study design
- Primary purpose
- Device feasibility
- Allocation
- Not applicable
- Intervention model
- Single group
- Masking
- None (open label)
- Number of arms
- 1
- Model description
- A single group of up to 10 participants will be enrolled to evaluate a radiofrequency wire for cutting through liver parenchyma instead of the standard trocar needle during transjugular intrahepatic portosystemic shunt creation. This will be to test this device for feasibility and not health outcomes.
| Arm | Type | Receives |
|---|---|---|
| Intervention | Experimental | Device: Radiofrequency wire (Powerwire)Undergo transjugular intrahepatic portosystemic shunt creation using a radiofrequency wire (Powerwire) in lieu of a trocar needle to cut through liver parenchyma |
Who may qualify
- Ages
- 20 to 99 years
- Sex
- All
- Healthy volunteers
- Not accepted
- Age groups
- Adult, Older adult
Key inclusion criteria (3 listed)
- Patients with cirrhosis and portal hypertension meeting at least one indication for elective TIPS creation including refractory ascites, acute variceal bleeding not responsive to endoscopic treatment, prevention of recurrent variceal bleeding, portal hypertensive gastropathy, hepatorenal syndrome, Budd-Chiari syndrome, hepatic hydrothorax, hepatic veno-occlusive disease, and hepatopulmonary syndrome.
- Patients who agree to undergo TIPS procedure and participate in this clinical study.
- Age over 20 years
Key exclusion criteria (4 listed)
- Patients with a contraindication for TIPS including congestive heart failure, severe tricuspid regurgitation, severe pulmonary hypertension, uncontrolled systemic infection or sepsis and unrelieved biliary obstruction.
- Patients in whom intravascular ultrasound cannot be used because of venous occlusion.
- Decisionally impaired patients
- Need for emergent TIPS creation
Eligibility is decided by the study team after screening; this overview does not establish that a patient qualifies. Full inclusion and exclusion criteria.
Interventions
| Intervention | Type | Arms |
|---|---|---|
| Radiofrequency wire (Powerwire)Using a radiofrequency wire in lieu of a needle for penetrating the liver during transjugular intrahepatic portosystemic shunt creation. | Device | Intervention |
Primary outcome
Feasibility to use the device as anticipated
Time frame: within 24 hours
Ability of the device to perform as anticipated
Incidence of device-related adverse events (Safety)
Time frame: within 24 hours
No device-related adverse events
2 secondary outcomes
Penetrating ability
Time frame: within 24 hours
Device use as a standard working wire
Time frame: within 24 hours
Results and safety
The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.
Research links
- Official record on ClinicalTrials.govLast updated by the sponsor 3 Nov 2023.
- Individual participant dataSharing planned: Yes. HIPAA compliant, IRB-approved, non-identifiable information may be provided for research outcomes purposes.
Related trials for Portal Hypertension
RecruitingObservational study
The Value of Spleen Thickness and Spleen Diameter for Gastroesophageal Varices Diagnosis in Compensated Cirrhosis
Liver Cirrhosis, Gastroesophageal Varices
RecruitingObservational study
Treatment Outcomes and Predictors After Endovascular Intervention for Portal Hypertension-Related Gastrointestinal Bleeding in Cirrhosis
Cirrhosis, Portal Hypertension Related to Cirrhosis
Not yet recruitingObservational study
Development and Validation of a TIPS Prognostic Model
Portal Hypertension Related to Cirrhosis, Ascites
RecruitingObservational study
Natural History of Noncirrhotic Portal Hypertension
Cystic Fibrosis, Immunologic Deficiency Syndrome
RecruitingPhase 2
Perioperative Retlirafusp Alfa(Anti-PD-L1/TGF-β Bifunctional Fusion Protein) Plus Famitinib and GEMOX-Based Hepatic Arterial Infusion Chemotherapy for Locally Advanced Intrahepatic Cholangiocarcinoma: A Multicenter, Single-Arm, Exploratory Phase II Trial
Intrahepatic Cholangiocarcinoma (Icc), Neoadjuvant Therapy
Referral and contact
AzTrials does not enrol participants or take referrals. Contact the study team or a site listed below; they decide who can take part. This study is not recruiting at the moment.
Khashayar Farsad, MD principal investigator
Oregon Health and Science University
1 site in 1 country: see every site and its status.
Questions about this trial
What is this clinical trial studying?
A study testing Radiofrequency wire (Powerwire) in people with Portal Hypertension, run by Oregon Health and Science University at 1 site in United States.
The full registered description is in the About this study section and the official record.
Who may be eligible to take part?
The sponsor lists 3 inclusion and 4 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.
Is this clinical trial currently recruiting?
The record says: finished, as of the sponsor's last update on 3 Nov 2023. Status can change between updates, so confirm with the study contact before making plans.
Where is the study taking place?
The record lists 1 site in United States. Whether a site is taking part right now should be confirmed with that site. See every site.
What are the possible benefits and risks?
They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.
Are results available for this study?
The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.
How can a doctor refer a patient or contact the research team?
The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.
What does the primary outcome measure?
Feasibility to use the device as anticipated (time frame: within 24 hours). The study lists 2 primary outcomes in all. It is what the study was designed to measure, not a finding.
Where can I read the original study information?
Does a listing mean the treatment is approved or proven to work?
No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.
How often is this information updated?
AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 3 Nov 2023.