Automated Oxygen Delivery by O2matic to Patients Admitted With an Exacerbation in COPD

A study testing O2matic in people with COPD Exacerbation and Hypoxia, run by Hvidovre University Hospital at 2 sites in Denmark.

Completed

Finished. The study has ended and is not enrolling. Results may be posted on the official record.

Official record

Search all trials

Trial summary

The aim of the study is to examine if automated oxygen delivery with O2matic is better than manually controlled oxygen therapy for patients admitted to hospital with an exacerbation in Chronic Obstructive Pulmonary Disease (COPD). Read more about this study

Who is it for?
Ages 35 years and older
Conditions the study is for
COPD Exacerbation, Hypoxia, Hyperoxia
What is being tested?
O2matic
Type of treatment
Medical device
Could I receive a placebo?
No, everyone receives an active treatment
How many people
20 participants
Where
2 sitesDenmark
Study dates
7 May 2018to 8 Aug 2018
Phase
Interventional

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 35 years and older
  • All sexes
  • No healthy volunteers
  • Adult, Older adult

Who may be able to join

  • COPD verified by FEV1/FVC < 0,70
  • Admission due to exacerbation in COPD
  • COPD exacerbation and pneumonia can be included
  • Duration of admission > 48 hours
  • Need for oxygen supplementation at inclusion (SpO2 <= 88 % without O2 suppl.)
  • Cognitively able to participate in the study
  • Willing to participate and give informed consent.

Who cannot join

  • Need or anticipated need for mechanical ventilation (except intermittent CPAP)
  • Major co-morbidities (cancer, heart disease, thromboembolic disease, uncontrolled diabetes)
  • Asthma or other respiratory condition requiring higher SpO2 than normal for COPD- patients
  • Pregnancy
  • Acute thromboembolic disease (< 2 weeks)
  • Cognitive barriers for participation

Trial locations and contacts

2 sites in 1 country.

Denmark2 sites
  • Gentofte University Hospital

    Hellerup, 2900

  • Hvidovre University Hospital

    Hvidovre, 2650

Other trials in Denmark

About this study

The aim of the study is to examine if automated oxygen delivery with O2matic is better than manually controlled oxygen therapy for patients admitted to hospital with an exacerbation in Chronic Obstructive Pulmonary Disease (COPD).

O2matic is a closed -loop system based on continuous non-invasive measurement of pulse and oxygen-saturation that is processed in an algorithm that controls the flow of oxygen to the patient.

The primary hypothesis is that O2matic increases time within acceptable oxygen-saturation interval. Secondary hypotheses are that O2matic compared to manual control reduces time with severe hypoxia (SpO2 < 85 %), hypoxi (SpO2 below intended interval) and hyperoxia (SpO2 above intended interval).

Read the detailed description

Closed-loop control of oxygen therapy is described in the literature used for preterm infants, trauma patients, medical emergency use and patients with COPD. For the latter, closed-loop therapy has been used for patients admitted to hospital with an exacerbation, for domiciliary oxygen use and during exercise. O2matic is a closed-loop system that is based on continuous and non-invasive measurement of pulse, oxygen-saturation and respiratory frequency. The algorithm in O2matic controls oxygen delivery with the aim of keeping the saturation within the desired interval, which could be 88-92 % for COPD-patients in accordance with international guidelines on this topic. Saturation interval can be set for the individual patients, as can the range of acceptable oxygen-flow. If saturation or oxygen-flow can't be maintained within the desired intervals an alarm will sound.

All studies on closed-loop systems have shown that this method is better than manually control by nurse to maintain saturation within the desired interval. Furthermore, some studies have indicated that closed-loop has the possibility to reduce admission time and to reduce time spent with oxygen therapy, due to more efficient and fast withdrawal from oxygen supplementation.

In the present study O2matic will be tested versus manual control, for patients admitted with an exacerbation in COPD, and in need of supplemental oxygen. During the study the patients will either have oxygen controlled with O2matic or manually by nursing staff. All patients will have continuous logging of pulse, oxygen-saturation and oxygen-flow with O2matic, but only in the O2matic active group, the algorithm will control oxygen-delivery.

The primary hypothesis will be tested, which is that O2matic is better than manual control for maintaining oxygen-saturation within the desired interval and reducing time with unintended hypoxia and hyperoxia. For this purpose 20 patients will be included in a crossover design with 4 hours of O2matic-controlled oxygen treatment and 4 hours with manually titrated oxygen with a 16 hours washout between periods.

No safety issues has been reported in the literature. Before use O2matic will be approved by The Danish Medicines Agency, The Ethics Committee in the Capital Region of Denmark and by the regional Data Protection Board. The study will be conducted according to GCP standards with independent monitoring. All adverse events and serious adverse events will be monitored and serious adverse events will be reported to Danish Medicines Agency.

Being tested
O2matic
Keywords
closed-loop, oxygen treatment
Medical subject headings
Hypoxia, Hyperoxia, Respiratory Insufficiency

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • O2maticDevice

    Continous measurement of SpO2 during an admission with COPD, and closed-loop control of oxygen-delivery to maintain SpO2 within a target interval.

Study groups in NCT03464695
Study groupRoleWhat they receive
O2maticActive comparatorOxygen administered by O2matic. Automatic adjustment based on continuous measurement of SpO2.
Receives: Device: O2matic
ManualNo interventionOxygen administered by manual control based on nurse's intermittent measurement of SpO2.

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. Time within SpO2-interval

    Fraction of time where SpO2 is kept within desired interval (e.g. 88-92 %) relative to time with SpO2-signal.

    Measured: 4 hours

Secondary outcomes (3)
  1. Time with severe hypoxia

    Fraction of time where SpO2 is below 85 % relative to time with SpO2 signal

    Measured: 4 hours

  2. Time with hypoxia

    Fraction of time where SpO2 is below intended interval but not below 85 % relative to time with SpO2 signal

    Measured: 4 hours

  3. Time with hyperoxia

    Fraction of time where SpO2 is above intended interval relative to time with SpO2 signal

    Measured: 4 hours

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted14 Mar 2018
  2. Study start7 May 2018
  3. Primary completion8 Aug 2018
  4. Study completion8 Aug 2018

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Interventional
Phase
Phase N/A
Primary purpose
Treatment
Allocation
Randomised
Intervention model
Crossover
Masking
None (open label)
Enrolment
20 participants (actual)
IDs, dates and publications
ClinicalTrials.gov ID
NCT03464695
Sponsor's protocol ID
O2MATIC-COPD
Acronym
O2MATIC
Status last verified
Sep 2026
First submitted
2 Mar 2018
Last updated
9 Sep 2026
Results posted
No
Data monitoring committee
Yes
FDA-regulated drug
No
FDA-regulated device
No
Individual data sharing
No

Publications

  • Claure N, Bancalari E. Closed-loop control of inspired oxygen in premature infants. Semin Fetal Neonatal Med. 2015 Jun;20(3):198-204. doi: 10.1016/j.siny.2015.02.003. Epub 2015 Mar 12.

    PubMed 25773271
  • Johannigman JA, Branson R, Lecroy D, Beck G. Autonomous control of inspired oxygen concentration during mechanical ventilation of the critically injured trauma patient. J Trauma. 2009 Feb;66(2):386-92. doi: 10.1097/TA.0b013e318197a4bb.

    PubMed 19204511
  • L'Her E, Dias P, Gouillou M, Riou A, Souquiere L, Paleiron N, Archambault P, Bouchard PA, Lellouche F. Automatic versus manual oxygen administration in the emergency department. Eur Respir J. 2017 Jul 20;50(1):1602552. doi: 10.1183/13993003.02552-2016. Print 2017 Jul.

    PubMed 28729473
  • Lellouche F, Bouchard PA, Roberge M, Simard S, L'Her E, Maltais F, Lacasse Y. Automated oxygen titration and weaning with FreeO2 in patients with acute exacerbation of COPD: a pilot randomized trial. Int J Chron Obstruct Pulmon Dis. 2016 Aug 24;11:1983-90. doi: 10.2147/COPD.S112820. eCollection 2016.

    PubMed 27601891
  • Lellouche F, L'Her E, Bouchard PA, Brouillard C, Maltais F. Automatic Oxygen Titration During Walking in Subjects With COPD: A Randomized Crossover Controlled Study. Respir Care. 2016 Nov;61(11):1456-1464. doi: 10.4187/respcare.04406. Epub 2016 Oct 18.

    PubMed 27794080
  • Rice KL, Schmidt MF, Buan JS, Lebahn F, Schwarzock TK. AccuO2 oximetry-driven oxygen-conserving device versus fixed-dose oxygen devices in stable COPD patients. Respir Care. 2011 Dec;56(12):1901-5.

    PubMed 22288082
  • Hansen EF, Hove JD, Bech CS, Jensen JS, Kallemose T, Vestbo J. Automated oxygen control with O2matic(R) during admission with exacerbation of COPD. Int J Chron Obstruct Pulmon Dis. 2018 Dec 14;13:3997-4003. doi: 10.2147/COPD.S183762. eCollection 2018.

    PubMed 30587955

Free account

Keep searching with a free account

You’ve used your 3 free searches for this session. Log in or create a free AzTrials account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in