Trial summary

Prospective non interventional, observational registry of 150 patients undergoing TAVI with Evolut platform for bicuspid aortic stenosis. Read more about this study

Who is it for?
Ages 18 years and older
Conditions the study is for
Bicuspid Aortic Valve
What is being tested?
Transcatheter Aortic Valve Implantation
Type of treatment
Medical device
How many people
150 participants
Where
1 siteFrance
Study dates
5 Jun 2018to 17 Dec 2020
How long will I take part?
1 Year
Phase
Observational
Are there results?
None posted in the registry

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 18 years and older
  • All sexes
  • No healthy volunteers
  • Adult, Older adult

Study population: All consecutive patients presenting with severe and symptomatic bicuspid aortic valve stenosis or mixed disease

Who may be able to join

  • Age ≥18 years.
  • NYHA≥2 and/or syncope and/or angina.
  • Patient judged by the Heart Team as indicated for TAVI.
  • Anatomical suitability for transfemoral-TAVI with Evolut Pro or Evolut R XL, based on MSCT assessment.
  • Estimated life-expectancy>1 year.

Who cannot join

  • Age <18 years
  • Asymptomatic patients
  • Estimated life expectancy<1 year
  • Pure aortic regurgitation.
  • LVEF<20%
  • No baseline MSCT evaluation.
  • Unsuitable aortic root anatomy for Evolut Pro or XL.
  • Unsuitable peripheral vasculature for transfemoral Evolut Pro or XL.

Trial locations and contacts

1 site in 1 country.

France1 site
  • Clinique Pasteur

    Toulouse, Occitanie, 31076

Other trials in France

About this study

Prospective non interventional, observational registry of 150 patients undergoing TAVI with Evolut platform for bicuspid aortic stenosis.

Read the detailed description

Study Design Study Design: prospective non-interventional multicenter registry Screening: MSCT submitted to core lab \& sizing strategy pre-declared (annular sizing, supra-annular sizing, mix of both methods) Follow up: MSCT and TTE to cooper lab

TAVI treatment Predilatation according to aortic annulus Dmin Evolut Pro (23-26-29) and Evolut R 34 XL Annular anchoring of the THV Postdilatation according to the operators' discretion Study Population All consecutive patients presenting with severe and symptomatic bicuspid aortic valve stenosis or mixed disease

Inclusion Criteria 1. Age ≥18 years. 2. NYHA≥2 and/or syncope and/or angina. 3. Patient judged by the Heart Team as indicated for TAVI. 4. Anatomical suitability for transfemoral-TAVI with Evolut Pro or Evolut R XL, based on MSCT assessment.

  1. Estimated life-expectancy>1 year.

Exclusion Criteria 1. Age <18 years 2. Asymptomatic patients 3. Estimated life expectancy<1 year 4. Pure aortic regurgitation. 5. LVEF<20% 6. No baseline MSCT evaluation. 7. Unsuitable aortic root anatomy for Evolut Pro or XL. 8. Unsuitable peripheral vasculature for transfemoral Evolut Pro or XL. Primary Endpoint Valve performane Secondary endpoints 30 day and 1 year mortality Patient-prosthesis mismatch Ellipticity index at 30 days Follow-up 30 days: physical examination, ECG, TTE /MSCT upon operators' judgement

1 year: physical examination, ECG, TTE.

Being tested
Transcatheter Aortic Valve Implantation
Keywords
Bicuspid, TAVI, TAVR, self-expanding, Evolut
Medical subject headings
Bicuspid Aortic Valve Disease

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • Transcatheter Aortic Valve ImplantationDevice

    Also called Transcatheter Aortic Valve Replacement

    Transcatheter treatment of bicuspid aortic stenosis with the Evolut Pro/XL platform

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. Valve performance

    effective orifice area<0.85 cm2/m2 and/or mean gradient>20 mmHg and/or aortic regurgitation>moderate

    Measured: 30 days

  2. Valve performance

    effective orifice area<0.85 cm2/m2 and/or mean gradient>20 mmHg and/or aortic regurgitation>moderate

    Measured: one year

Secondary outcomes (3)
  1. mortality

    Measured: 30 days and one year

  2. Patient-prosthesis mismatch

    indexed effective area <0.65 cm2/m2

    Measured: 30 days and 1 year

  3. Ellipticity index at 30 days

    Measured: 30 days

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted11 Apr 2018
  2. Study start5 Jun 2018
  3. Primary completion10 Feb 2020
  4. Study completion17 Dec 2020

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Observational
Observational model
Cohort
Time perspective
Prospective
Enrolment
150 participants (actual)
Target duration
1 Year
IDs, dates and publications
ClinicalTrials.gov ID
NCT03495050
Sponsor's protocol ID
2018-A00290-55
Acronym
BIVOLUTX
Status last verified
Jun 2026
First submitted
3 Mar 2018
Last updated
18 Jun 2026
Results posted
No
Data monitoring committee
Yes
FDA-regulated drug
No
FDA-regulated device
Yes
Individual data sharing
Undecided: Mutual ananymized database. Substudies anticipated.

Publications

  • Tchetche D, Ziviello F, De Biase C, De Backer O, Hovasse T, Leroux L, Petronio AS, Saint-Etienne C, Teles RC, Modine T, Sudre A, Teiger E, Mylotte D, Souteyrand G, Piazza N, Casassus F, Sondergaard L, Angelillis M, Nolasco T, Siddiqui S, Kardys I, Dumonteil N, Van Mieghem NM. Transcatheter aortic valve implantation with the Evolut platform for bicuspid aortic valve stenosis: the international, multicentre, prospective BIVOLUTX registry. EuroIntervention. 2023 Aug 21;19(6):502-511. doi: 10.4244/EIJ-D-23-00021.

    PubMed 37203860
  • Tchetche D, de Biase C, van Gils L, Parma R, Ochala A, Lefevre T, Hovasse T, De Backer O, Sondergaard L, Bleiziffer S, Lange R, Kornowski R, Landes U, Norgaard BL, Biasco L, Philippart R, Molina-Martin de Nicolas J, Mylotte D, Lemee C, Dumonteil N, Van Mieghem NM. Bicuspid Aortic Valve Anatomy and Relationship With Devices: The BAVARD Multicenter Registry. Circ Cardiovasc Interv. 2019 Jan;12(1):e007107. doi: 10.1161/CIRCINTERVENTIONS.118.007107.

    PubMed 30626202

Questions about this trial

What is this clinical trial studying?

An observational study of Bicuspid Aortic Valve, run by Clinique Pasteur at 1 site in France.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 5 inclusion and 8 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: finished, as of the sponsor's last update on 18 Jun 2026. Status can change between updates, so confirm with the study contact before making plans.

Where is the study taking place?

The record lists 1 site in France. Whether a site is taking part right now should be confirmed with that site. See every site.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.

How can a doctor refer a patient or contact the research team?

The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

Valve performance (time frame: 30 days). The study lists 2 primary outcomes in all. It is what the study was designed to measure, not a finding.

Where can I read the original study information?

On the ClinicalTrials.gov record for NCT03495050, which also lists 2 linked publications.

Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 18 Jun 2026.

Free account

Keep searching with a free account

You’ve used your 3 free searches for this session. Log in or create a free AzTrials account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in