PresbyopiaNCT03499821

Clinical Performance of a Phakic Intraocular Lens (IOL)

A study testing EDOF ICL in people with Presbyopia, run by Staar Surgical Company at 6 sites in 2 countries.

Completed

Finished. The study has ended and is not enrolling. Results may be posted on the official record.

Official record
Search all trials

Trial summary

This study will evaluate the clinical performance of a phakic intraocular lens (IOL) for the improvement of Uncorrected Near Visual Acuity (UCNVA) in subjects who require between +1.00 and +2.50 Reading Add. Read more about this study

Who is it for?
Ages 40 to 60 years
Conditions the study is for
Presbyopia
What is being tested?
EDOF ICL
Could I receive a placebo?
No, everyone receives an active treatment
How many people
41 participants
Where
6 sitesin 2 countries
Study dates
20 Mar 2018to 9 Jul 2019
Phase
Interventional
Are there results?
Yes, posted in the registrySummary in the doctors' view

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 40 to 60 years
  • All sexes
  • No healthy volunteers
  • Adult

Who may be able to join

  • Must be able to read, understand and provide written informed consent,
  • Willing and able to comply with all treatment and follow-up study related procedures,
  • 40 - 60 years of age at time of surgery if require spherical lens powers from -0.50 D to -18.00 D,
  • 35 - 45 years of age at time of surgery if require a spherical lens power from 0.0 D to +3.00 D,
  • Preoperative refraction fully correctable with available lens powers, with ≤ 0.75 D preoperative refractive and residual cylinder,
  • < 0.75 D spherical equivalent difference between cycloplegic and manifest refractions,
Show all 16Show fewer
  • Stable correction (± 0.50 D) as determined by manifest refraction spherical equivalent (MRSE),
  • Best Corrected Distance Visual Acuity 20/20 or better in both eyes,
  • Requires +1.00 D to +2.50 D reading add,
  • Anterior chamber depth (ACD) ≥ 2.8 mm if require spherical lens powers from -0.50 D to -18.00 D,
  • ACD ≥ 3.0 mm if require spherical lens powers from 0.00 D to +3.00 D,
  • Anterior chamber angle ≥ Grade III,
  • Phakic in both eyes,
  • Current contact lens wearers need to demonstrate a stable refraction, (± 0.5 D), expressed as MRSE, on two consecutive examination dates with refractive stability determined by the following criteria:
  • contact lenses were not worn for at least 2 weeks (rigid and toric contact lenses) or 3 days (soft contact lenses) prior to the first refraction,
  • two refractions were performed at least 7 days apart.

Who cannot join

  • Participation in a clinical trial within 30 days prior to entry into this study and/or during the period of study participation,
  • Previous intraocular or corneal surgery in either eye, including refractive surgery,
  • Progressive sight threatening disease or other previous or current ocular conditions, other than myopia in either eye,
  • Low/abnormal corneal endothelial cell density,
  • Amblyopia,
  • Presence of active or history of chronic inflammation in either eye,
Show all 13Show fewer
  • Clinically significant irregular astigmatism in either eye,
  • Serious, acute, chronic or systemic, non-ophthalmic disease or illness that would increase the operative risk, confound the outcome(s) of the study or which may preclude study completion,
  • Use of topical steroids at time of implantation,
  • Systemic or topical medication, other than prescribed study medications that may confound the outcome or increase the risk to the subject,
  • Allergy to anesthetics or other postoperative medications required in this study,
  • Subject who is pregnant, plans to become pregnant, or is lactating during the course of the study, or has another condition associated with the fluctuation of hormones that could lead to refractive changes,
  • Subjects who present any emotional, physiologic, or anatomical condition which may preclude study participation.

Trial locations and contacts

6 sites in 2 countries.

6 sites in 2 countries

Spain5 sites
  • Qvision-Hospital Vithas Virgen del Mar

    Almería, 04120

  • IMO Instituto de Microcirugía Ocular

    Barcelona, 08035

  • Instituto Oftalmológico Fernández-Vega

    Oviedo, Principality of Asturias, 33012

  • Innova Ocular Begitek

    San Sebastián, 20012

  • Clínica Oftalmológica Gasteiz

    Vitoria-Gasteiz, 01005

Other trials in Spain

Belgium1 site
  • Mediopolis

    Antwerp, B-2610

Other trials in Belgium

About this study

Official title: A Multicenter Clinical Evaluation of the Clinical Performance of a Phakic Intraocular Lens

This study will evaluate the clinical performance of a phakic intraocular lens (IOL) for the improvement of Uncorrected Near Visual Acuity (UCNVA) in subjects who require between +1.00 and +2.50 Reading Add.

Read the detailed description

This is a prospective, open-labeled, multi-site evaluation of clinical performance of the STAAR EVO+ Visian™ Implantable Collamer® Lens (VICL) with Aspheric (EDOF) Optic [EDOF ICL] for the improvement of UCNVA in subjects who require between +1.00 and +2.50 Reading Add.

Approximately 48 subjects who meet all eligibility criteria will undergo EDOF ICL implantation in both eyes. All eyes will be followed for 6 months after surgery.

The first eye implanted with the study lens and the appropriate time for fellow eye implantation will be determined by the medical judgement of the Investigator. All eyes will be analyzed for safety and performance.

The primary performance endpoint is defined as achievement of monocular UCNVA of Snellen equivalent 20/40 or better at 40 cm at 6 months after implantation in equal to or greater than 75% of implanted eyes.

Conditions
Presbyopia
Being tested
EDOF ICL
Medical subject headings
Presbyopia

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • EDOF ICLDevice

    Also called EVO+ Visian ICL with Aspheric (EDOF) Optic

    The Visian ICL is intended to be implanted within the posterior chamber, directly behind the iris, and in front of the anterior capsule of the human crystalline lens. It offers an intraocular alternative for the correction of refractive error in those who currently utilize spectacle and/or contact lenses correction.

Study groups in NCT03499821
Study groupRoleWhat they receive
Study populationExperimentalEDOF ICL implanted into both eyes of eligible subjects.
Receives: Device: EDOF ICL

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. Number of Eyes With Monocular Uncorrected Near Visual Acuity of 20/40 or Better at 40 cm 6 Months After Implantation

    Number of Eyes with Monocular Uncorrected Near Visual Acuity of 20/40 or better at 40 cm six months after implantation

    Measured: 6 months

Secondary outcomes (17)
  1. Percentage of Implanted Eyes Achieving Monocular Uncorrected Near Visual Acuity of 20/40 or Better at 40 cm 1 Month After Implantation

    Percentage of implanted eyes achieving Monocular Uncorrected Near Visual Acuity (UNVA) of 20/40 or better at 40 cm 1 month after implantation

    Measured: 1 month

  2. Percentage of Implanted Eyes Achieving Monocular Uncorrected Near Visual Acuity of 20/40 or Better at 40 cm 3 Months After Implantation

    Percentage of implanted eyes achieving Monocular Uncorrected Near Visual Acuity (UNVA) of 20/40 or better at 40 cm 3 months after implantation

    Measured: 3 months

  3. Change From Baseline in Monocular Uncorrected Intermediate Visual Acuity at 80 cm 1 Month Post Implantation

    Change from baseline in Monocular Uncorrected Intermediate Visual Acuity (UIVA) at 80 cm 1 month post implantation

    Measured: Baseline and 1 month

  4. Change From Baseline in Monocular Uncorrected Intermediate Visual Acuity at 80 cm 3 Months Post Implantation

    Change from baseline in Monocular Uncorrected Intermediate Visual Acuity (UIVA) at 80 cm 3 months post implantation

    Measured: Baseline and 3 months

  5. Change From Baseline in Monocular Uncorrected Intermediate Visual Acuity at 80 cm 6 Months Post Implantation

    Change from baseline in Monocular Uncorrected Intermediate Visual Acuity (UIVA) at 80 cm 6 months post implantation

    Measured: Baseline and 6 months

  6. Change From Baseline in Monocular Uncorrected Near Visual Acuity at 40 cm 1 Month Post Implantation

    Change from baseline in Monocular Uncorrected Near Visual Acuity (UNVA) at 40 cm 1 month post implantation

    Measured: Baseline and 1 month

  7. Change From Baseline in Monocular Uncorrected Near Visual Acuity at 40 cm 3 Months Post Implantation

    Change from baseline in Monocular Uncorrected Near Visual Acuity (UNVA) at 40 cm 3 months post implantation

    Measured: Baseline and 3 months

  8. Change From Baseline in Monocular Uncorrected Near Visual Acuity at 40 cm 6 Months Post Implantation

    Change from baseline in Monocular Uncorrected Near Visual Acuity (UNVA) at 40 cm 6 months post implantation

    Measured: Baseline and 6 months

  9. Change From Baseline in Monocular Distance Corrected Intermediate Visual Acuity at 80 cm 1 Month Post Implantation

    Change from baseline in Monocular Distance Corrected Intermediate Visual Acuity (DCIVA) at 80 cm 1 month post implantation

    Measured: Baseline and 1 month

  10. Change From Baseline in Monocular Distance Corrected Intermediate Visual Acuity at 80 cm 3 Months Post Implantation

    Change from baseline in Monocular Distance Corrected Intermediate Visual Acuity (DCIVA) at 80 cm 3 months post implantation

    Measured: Baseline and 3 months

  11. Change From Baseline in Monocular Distance Corrected Intermediate Visual Acuity at 80 cm 6 Months Post Implantation

    Change from baseline in Monocular Distance corrected intermediate visual acuity (DCIVA) at 80 cm 6 months post implantation

    Measured: Baseline and 6 months

  12. Change From Baseline in Monocular Distance Corrected Near Visual Acuity at 40 cm 1 Month Post Implantation

    Change from baseline in Monocular Distance Corrected Near Visual Acuity (DCNVA) at 40 cm 1 month post implantation

    Measured: Baseline and 1 month

  13. Change From Baseline in Monocular Distance Corrected Near Visual Acuity at 40 cm 3 Months Post Implantation

    Change from baseline in Monocular Distance Corrected Near Visual Acuity (DCNVA) at 40 cm 3 months post implantation

    Measured: Baseline and 3 months

  14. Change From Baseline in Monocular Distance Corrected Near Visual Acuity at 40 cm 6 Months Post Implantation

    Change from baseline in Monocular Distance Corrected Near Visual Acuity (DCNVA) at 40 cm 6 months post implantation

    Measured: Baseline and 6 months

  15. Change From Baseline in Binocular Uncorrected Near Visual Acuity at 40 cm 1 Month Post Implantation

    Change from baseline in Binocular Uncorrected Near Visual Acuity (UNVA) at 40 cm 1 month post implantation

    Measured: Baseline and 1 month

  16. Change From Baseline in Binocular Uncorrected Near Visual Acuity at 40 cm 3 Months Post Implantation

    Change from baseline in Binocular Uncorrected Near Visual Acuity (UNVA) at 40 cm 3 months post implantation

    Measured: Baseline and 3 months

  17. Change From Baseline in Binocular Uncorrected Near Visual Acuity at 40 cm 6 Months Post Implantation

    Change from baseline in Binocular Uncorrected Near Visual Acuity (UCNVA) at 40 cm 6 months post implantation

    Measured: Baseline and 6 months

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted17 Apr 2018
  2. Study start20 Mar 2018
  3. Primary completion9 Jul 2019
  4. Study completion9 Jul 2019

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Interventional
Phase
Phase N/A
Primary purpose
Treatment
Allocation
Not applicable
Intervention model
Single group
Model description
Device: Open label, all subjects receive same treatment
Masking
None (open label)
Enrolment
41 participants (actual)
IDs, dates and publications
ClinicalTrials.gov ID
NCT03499821
Sponsor's protocol ID
Study CP17-01
Status last verified
Mar 2026
First submitted
9 Apr 2018
Last updated
16 Mar 2026
Data monitoring committee
No
FDA-regulated drug
No
FDA-regulated device
Yes
Individual data sharing
No

Publications

  • Packer M, Alfonso JF, Aramberri J, Elies D, Fernandez J, Mertens E. Performance and Safety of the Extended Depth of Focus Implantable Collamer(R) Lens (EDOF ICL) in Phakic Subjects with Presbyopia. Clin Ophthalmol. 2020 Sep 18;14:2717-2730. doi: 10.2147/OPTH.S271858. eCollection 2020.

    PubMed 32982164

Questions about this trial

What is this clinical trial studying?

A study testing EDOF ICL in people with Presbyopia, run by Staar Surgical Company at 6 sites in 2 countries.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 16 inclusion and 13 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: finished, as of the sponsor's last update on 16 Mar 2026. Status can change between updates, so confirm with the study contact before making plans.

Where is the study taking place?

The record lists 6 sites in Spain, Belgium. Whether a site is taking part right now should be confirmed with that site. See every site.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

Yes. Results are posted in the registry (first posted 21 Sep 2022). A summary is in the For doctors view, and the full results are on ClinicalTrials.gov.

How can a doctor refer a patient or contact the research team?

The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

Number of Eyes With Monocular Uncorrected Near Visual Acuity of 20/40 or Better at 40 cm 6 Months After Implantation (time frame: 6 months). It is what the study was designed to measure, not a finding.

Where can I read the original study information?

On the ClinicalTrials.gov record for NCT03499821, which also lists 1 linked publication.

Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 16 Mar 2026.

Free account

Log in to keep searching

You’ve used your 3 free searches. AzTrials is free: log in or create a free account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in