Respiratory FailureVHI-HDNCT03557645
Ventilator Hyperinflation and Hemodynamics
A study testing Baseline Mechanical Ventilation, VHI With Inspiratory Pause and VHI Without Inspiratory Pause in people with Respiratory Failure and Respiratory Disorders, run by Centro Universitário Augusto Motta at 1 site in Brazil.
Trial summary
Ventilator hyperinflation (VHI) has been shown to be effective in improving respiratory mechanics, secretion removal, and gas exchange in mechanically ventilated patients; however, the literature is scarce concerning its safety and adverse effects. Read more about this study
- Who is it for?
- Ages 18 to 90 years
- Conditions the study is for
- Respiratory Failure, Respiratory Disorders
- What is being tested?
- Baseline Mechanical Ventilation, VHI With Inspiratory Pause and VHI Without Inspiratory Pause
- Type of treatment
- Medical device
- Could I receive a placebo?
- Yes, some participants may receive a placebo
- How many people
- 17 participants
- Where
- 1 siteBrazil
- Study dates
- 5 Nov 2017to 30 Sep 2018
- Phase
- Interventional
- Are there results?
- None posted in the registry
Key requirements
Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.
- Ages 18 to 90 years
- All sexes
- No healthy volunteers
- Adult, Older adult
Who may be able to join
- Patients under mechanical ventilation for more than 48h
Who cannot join
- mucus hypersecretion (defined as the need for suctioning < 2-h intervals),
- absence of respiratory drive,
- atelectasis,
- severe bronchospasm,
- positive end expiratory pressure > 10cmH2O,
- PaO2-FiO2 relationship < 150,
Show all 9Show fewer
- mean arterial pressure < 60mmHg,
- inotrope requirement equivalent to >15 ml/h total of adrenaline and noradrenalin,
- intracranial pressure > 20mmHg
Trial locations and contacts
1 site in 1 country.
About this study
Official title: Hemodynamic Repercussions of Ventilator Hyperinflation Using Volume-controlled Ventilation: a Randomized Controlled Trial
Ventilator hyperinflation (VHI) has been shown to be effective in improving respiratory mechanics, secretion removal, and gas exchange in mechanically ventilated patients; however, the literature is scarce concerning its safety and adverse effects. Thus, the aim of this study is to compare the hemodynamic repercussions of VHI in volume-controlled mode. In a randomized, controlled and crossover design, 24 mechanically ventilated patients will undergo 2 modes of ventilator hyperinflation (with and without an inspiratory pause) and a control intervention. Cardiac output, cardiac index, mean arterial pressure, pulmonary vascular resistance, systolic volume and other hemodynamic variables will be recorded during the interventions.
Read the detailed description
Background: ventilator hyperinflation (VHI) has been shown to be effective in improving respiratory mechanics, secretion removal, and gas exchange in mechanically ventilated patients; however, the literature is scarce concerning its safety and adverse effects. Thus, the aim of this study is to compare the hemodynamic repercussions of VHI in volume-controlled mode.
Methods: in a randomized, controlled and crossover design, 24 mechanically ventilated patients will undergo 2 modes of ventilator hyperinflation (with and without an inspiratory pause of 2 seconds) and a control intervention. For the VHI interventions, the inspiratory flow will be set at 20 Lpm, and tidal volume will be increased until a peak pressure of 40cmH2O is achieved. During the control intervention, the patients will remain in volume-control ventilation with an inspiratory flow = 60Lpm and tidal volume = 6mL/IBW. The interval between interventions (washout) will be of 10 minutes or more, according to the time needed to recover the cardiac index to baseline values (maximum difference of 10%). Cardiac output, cardiac index, mean arterial pressure, pulmonary vascular resistance, systolic volume and other hemodynamic variables will be recorded during the interventions by using impedance cardiography.
- Conditions
- Respiratory Failure, Respiratory Disorders
- Being tested
- Baseline Mechanical Ventilation, VHI With Inspiratory Pause, VHI Without Inspiratory Pause
- Keywords
- mechanical ventilation, physiotherapy, ventilator hyperinflation, airway clearance technique
- Medical subject headings
- Respiratory Insufficiency, Respiration Disorders
What participants receive
What participants receive. In a randomised study each person is assigned to one group by chance.
Baseline Mechanical VentilationDevice
The subjects will be kept in Volume Control Continuous Mandatory Ventilation (VC-CMV).
VHI With Inspiratory PauseDevice
Application of a ventilator hyperinflation intervention with Volume Control Continuous Mandatory Ventilation (VC-CMV) with an inspiratory pause.
VHI Without Inspiratory PauseDevice
Application of a ventilator hyperinflation intervention with Volume Control Continuous Mandatory Ventilation (VC-CMV) without an inspiratory pause.
| Study group | Role | What they receive |
|---|---|---|
| Baseline Mechanical Ventilation | Sham comparator | The subjects will be kept in Volume Control Continuous Mandatory Ventilation (VC-CMV) with an inspiratory flow = 60Lpm and tidal volume = 6mL/IBW. Positive end-expiratory pressure and the inspired oxygen fraction will not be modified. Receives: Device: Baseline Mechanical Ventilation |
| VHI With Inspiratory Pause | Experimental | Application of a ventilator hyperinflation intervention with Volume Control Continuous Mandatory Ventilation (VC-CMV). The inspiratory flow will be set at 20Lpm, the tidal volume will be increased in steps of 200mL until the peak airway pressure of 40cmH2O is achieved, and an inspiratory pause will be applied at the end of inspiration. After achieving the target pressure, this ventilatory regimen will last 15 minutes. Positive end-expiratory pressure and the inspired oxygen fraction will not be modified. Receives: Device: VHI With Inspiratory Pause |
| VHI Without Inspiratory Pause | Experimental | Application of a ventilator hyperinflation intervention with Volume Control Continuous Mandatory Ventilation (VC-CMV). The inspiratory flow will be set at 20Lpm and the tidal volume will be increased in steps of 200mL until the peak airway pressure of 40cmH2O is achieved. After achieving the target pressure, this ventilatory regimen will last 15 minutes. Positive end-expiratory pressure and the inspired oxygen fraction will not be modified. Receives: Device: VHI Without Inspiratory Pause |
What is being measured
The primary outcome is the main question the study is designed to answer.
Change in Cardiac Output
Estimation of cardiac output variation using thoracic bioimpedance
Measured: Baseline (before) and 10 minutes after the onset of VHI modesBasel
Secondary outcomes (9)
Change in Cardiac Index
Estimation of cardiac index variation using thoracic bioimpedance
Measured: Baseline (before) and 10 minutes after the onset of VHI modes
Change in Vascular pulmonary resistance
Estimation of vascular pulmonary resistance variation using thoracic bioimpedance
Measured: Baseline (before) and 10 minutes after the onset of VHI modes
Change in Systolic Volume
Estimation of systolic volume variation using thoracic bioimpedance
Measured: Baseline (before) and 10 minutes after the onset of VHI modes
Change in Mean Arterial Pressure
Recording of mean arterial pressure variation using an automatic noninvasive device
Measured: Baseline (before) and 10 minutes after the onset of VHI modes
Change in Cardiac Output II
Estimation of cardiac output variation using thoracic bioimpedance
Measured: Baseline (before) and 5 minutes after the end of VHI modes
Change in Cardiac Index II
Estimation of cardiac index variation using thoracic bioimpedance
Measured: Baseline (before) and 5 minutes after the end of VHI modes
Change in Vascular pulmonary resistance II
Estimation of vascular pulmonary resistance variation using thoracic bioimpedance
Measured: Baseline (before) and 5 minutes after the end of VHI modes
Change in Systolic Volume II
Estimation of systolic volume variation using thoracic bioimpedance
Measured: Baseline (before) and 5 minutes after the end of VHI modes
Change in Mean Arterial Pressure II
Recording of mean arterial pressure variation using an automatic noninvasive device
Measured: Baseline (before) and 5 minutes after the end of VHI modes
Timeline
From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.
- First posted15 Jun 2018
- Study start5 Nov 2017
- Primary completion20 Sep 2018
- Study completion30 Sep 2018
Resources
- Official record on ClinicalTrials.govThe registry entry this page is built from, with its full change history.
- Publications (3)Papers the sponsor has linked to this study.
- Other trials for Respiratory FailureStudies of the same condition, open and under way.
- What the trial phases meanHow a treatment moves from first tests in people to approval.
More details
For doctors and researchers: how the study is designed, who runs it, and its registry IDs.
Study design
- Study type
- Interventional
- Phase
- Phase N/A
- Primary purpose
- Treatment
- Allocation
- Randomised
- Intervention model
- Crossover
- Model description
- Crossover Assignment
- Masking
- Double blind
- Who is masked
- Investigator, Outcomes assessor
- Enrolment
- 17 participants (actual)
Sponsor and investigators
- Lead sponsor
- Centro Universitário Augusto Motta
- Sponsor type
- University, hospital or other
- Collaborators
- Universidade Federal do Rio de Janeiro
- Responsible party
- Sponsor
- Investigators
- Fernando Guimaraes, PhD, Study chair, Centro Universitário Augusto Motta
IDs, dates and publications
- ClinicalTrials.gov ID
- NCT03557645
- Sponsor's protocol ID
- VHI Hemodynamics
- Acronym
- VHI-HD
- Status last verified
- Aug 2020
- First submitted
- 13 May 2018
- Last updated
- 14 Aug 2020
- Results posted
- No
- Data monitoring committee
- Yes
- FDA-regulated drug
- No
- FDA-regulated device
- No
Publications
Berney S, Denehy L. A comparison of the effects of manual and ventilator hyperinflation on static lung compliance and sputum production in intubated and ventilated intensive care patients. Physiother Res Int. 2002;7(2):100-8. doi: 10.1002/pri.246.
PubMed 12109234Lemes DA, Zin WA, Guimaraes FS. Hyperinflation using pressure support ventilation improves secretion clearance and respiratory mechanics in ventilated patients with pulmonary infection: a randomised crossover trial. Aust J Physiother. 2009;55(4):249-54. doi: 10.1016/s0004-9514(09)70004-2.
PubMed 19929767Anderson A, Alexanders J, Sinani C, Hayes S, Fogarty M. Effects of ventilator vs manual hyperinflation in adults receiving mechanical ventilation: a systematic review of randomised clinical trials. Physiotherapy. 2015 Jun;101(2):103-10. doi: 10.1016/j.physio.2014.07.006. Epub 2014 Oct 6.
PubMed 25453540
Study at a glance
From the registry record, last updated by the sponsor on 14 Aug 2020. Recruitment status is as the sponsor reported it: confirm with the study team.
- Official title
- Hemodynamic Repercussions of Ventilator Hyperinflation Using Volume-controlled Ventilation: a Randomized Controlled Trial
- ClinicalTrials.gov ID
- NCT03557645
- Acronym / sponsor ID
- VHI-HD / VHI Hemodynamics
- Conditions
- Respiratory Failure, Respiratory Disorders
- Keywords
- mechanical ventilation, physiotherapy, ventilator hyperinflation, airway clearance technique
- Study type
- Interventional
- Recruitment status
- Completed
- Enrolment
- 17 participants (actual)
- Lead sponsor
- Centro Universitário Augusto MottaUniversity, hospital or other
- Collaborators
- Universidade Federal do Rio de Janeiro
- Study start
- 5 Nov 2017 (actual)
- Primary completion
- 20 Sep 2018 (actual)
- Study completion
- 30 Sep 2018 (actual)
- First posted
- 15 Jun 2018 (actual)
- Results
- Not posted in the source record
Clinical summary
The research question as the sponsor registered it. This describes what the study plans to test, not what it found.
Ventilator hyperinflation (VHI) has been shown to be effective in improving respiratory mechanics, secretion removal, and gas exchange in mechanically ventilated patients; however, the literature is scarce concerning its safety and adverse effects. Thus, the aim of this study is to compare the hemodynamic repercussions of VHI in volume-controlled mode. In a randomized, controlled and crossover design, 24 mechanically ventilated patients will undergo 2 modes of ventilator hyperinflation (with and without an inspiratory pause) and a control intervention. Cardiac output, cardiac index, mean arterial pressure, pulmonary vascular resistance, systolic volume and other hemodynamic variables will be recorded during the interventions.
Detailed description
Background: ventilator hyperinflation (VHI) has been shown to be effective in improving respiratory mechanics, secretion removal, and gas exchange in mechanically ventilated patients; however, the literature is scarce concerning its safety and adverse effects. Thus, the aim of this study is to compare the hemodynamic repercussions of VHI in volume-controlled mode.
Methods: in a randomized, controlled and crossover design, 24 mechanically ventilated patients will undergo 2 modes of ventilator hyperinflation (with and without an inspiratory pause of 2 seconds) and a control intervention. For the VHI interventions, the inspiratory flow will be set at 20 Lpm, and tidal volume will be increased until a peak pressure of 40cmH2O is achieved. During the control intervention, the patients will remain in volume-control ventilation with an inspiratory flow = 60Lpm and tidal volume = 6mL/IBW. The interval between interventions (washout) will be of 10 minutes or more, according to the time needed to recover the cardiac index to baseline values (maximum difference of 10%). Cardiac output, cardiac index, mean arterial pressure, pulmonary vascular resistance, systolic volume and other hemodynamic variables will be recorded during the interventions by using impedance cardiography.
Study design
- Primary purpose
- Treatment
- Allocation
- Randomised
- Intervention model
- Crossover
- Masking
- Double blind (investigator, outcomes assessor)
- Number of arms
- 3
- Model description
- Crossover Assignment
| Arm | Type | Receives |
|---|---|---|
| Baseline Mechanical Ventilation | Sham comparator | Device: Baseline Mechanical VentilationThe subjects will be kept in Volume Control Continuous Mandatory Ventilation (VC-CMV) with an inspiratory flow = 60Lpm and tidal volume = 6mL/IBW. Positive end-expiratory pressure and the inspired oxygen fraction will not be modified. |
| VHI With Inspiratory Pause | Experimental | Device: VHI With Inspiratory PauseApplication of a ventilator hyperinflation intervention with Volume Control Continuous Mandatory Ventilation (VC-CMV). The inspiratory flow will be set at 20Lpm, the tidal volume will be increased in steps of 200mL until the peak airway pressure of 40cmH2O is achieved, and an inspiratory pause will be applied at the end of inspiration. After achieving the target pressure, this ventilatory regimen will last 15 minutes. Positive end-expiratory pressure and the inspired oxygen fraction will not be modified. |
| VHI Without Inspiratory Pause | Experimental | Device: VHI Without Inspiratory PauseApplication of a ventilator hyperinflation intervention with Volume Control Continuous Mandatory Ventilation (VC-CMV). The inspiratory flow will be set at 20Lpm and the tidal volume will be increased in steps of 200mL until the peak airway pressure of 40cmH2O is achieved. After achieving the target pressure, this ventilatory regimen will last 15 minutes. Positive end-expiratory pressure and the inspired oxygen fraction will not be modified. |
Who may qualify
- Ages
- 18 to 90 years
- Sex
- All
- Healthy volunteers
- Not accepted
- Age groups
- Adult, Older adult
Key inclusion criteria (1 listed)
- Patients under mechanical ventilation for more than 48h
Key exclusion criteria (9 listed)
- mucus hypersecretion (defined as the need for suctioning < 2-h intervals),
- absence of respiratory drive,
- atelectasis,
- severe bronchospasm,
- positive end expiratory pressure > 10cmH2O,
Eligibility is decided by the study team after screening; this overview does not establish that a patient qualifies. Full inclusion and exclusion criteria.
Interventions
| Intervention | Type | Arms |
|---|---|---|
| Baseline Mechanical VentilationThe subjects will be kept in Volume Control Continuous Mandatory Ventilation (VC-CMV). | Device | Baseline Mechanical Ventilation |
| VHI With Inspiratory PauseApplication of a ventilator hyperinflation intervention with Volume Control Continuous Mandatory Ventilation (VC-CMV) with an inspiratory pause. | Device | VHI With Inspiratory Pause |
| VHI Without Inspiratory PauseApplication of a ventilator hyperinflation intervention with Volume Control Continuous Mandatory Ventilation (VC-CMV) without an inspiratory pause. | Device | VHI Without Inspiratory Pause |
Primary outcome
Change in Cardiac Output
Time frame: Baseline (before) and 10 minutes after the onset of VHI modesBasel
Estimation of cardiac output variation using thoracic bioimpedance
9 secondary outcomes
Change in Cardiac Index
Time frame: Baseline (before) and 10 minutes after the onset of VHI modes
Change in Vascular pulmonary resistance
Time frame: Baseline (before) and 10 minutes after the onset of VHI modes
Change in Systolic Volume
Time frame: Baseline (before) and 10 minutes after the onset of VHI modes
Change in Mean Arterial Pressure
Time frame: Baseline (before) and 10 minutes after the onset of VHI modes
Change in Cardiac Output II
Time frame: Baseline (before) and 5 minutes after the end of VHI modes
Change in Cardiac Index II
Time frame: Baseline (before) and 5 minutes after the end of VHI modes
Change in Vascular pulmonary resistance II
Time frame: Baseline (before) and 5 minutes after the end of VHI modes
Change in Systolic Volume II
Time frame: Baseline (before) and 5 minutes after the end of VHI modes
Change in Mean Arterial Pressure II
Time frame: Baseline (before) and 5 minutes after the end of VHI modes
Results and safety
The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.
Research links
- Official record on ClinicalTrials.govLast updated by the sponsor 14 Aug 2020.
- Results publication: PubMed 12109234Berney S, Denehy L. A comparison of the effects of manual and ventilator hyperinflation on static lung compliance and sputum production in intubated and ventilated intensive care patients. Physiother Res Int. 2002;7(2):100-8. doi: 10.1002/pri.246.
- Results publication: PubMed 19929767Lemes DA, Zin WA, Guimaraes FS. Hyperinflation using pressure support ventilation improves secretion clearance and respiratory mechanics in ventilated patients with pulmonary infection: a randomised crossover trial. Aust J Physiother. 2009;55(4):249-54. doi: 10.1016/s0004-9514(09)70004-2.
- Results publication: PubMed 25453540Anderson A, Alexanders J, Sinani C, Hayes S, Fogarty M. Effects of ventilator vs manual hyperinflation in adults receiving mechanical ventilation: a systematic review of randomised clinical trials. Physiotherapy. 2015 Jun;101(2):103-10. doi: 10.1016/j.physio.2014.07.006. Epub 2014 Oct 6.
Related trials for Respiratory Failure
Recruiting
Measuring Nasal Airway Changes After VivAer Treatment Using AI Analysis
Nasal Airway Obstruction
Not yet recruitingObservational study
Clinical Genetics Branch Eligibility Screening Survey
Melanoma, Li-Fraumeni Syndrome
RecruitingPhase 1/2
HS235 Study in Overweight and Obese Participants With Combined Pre and Post-Capillary Pulmonary Hypertension Due to Heart Failure With Preserved Ejection Fraction
Pulmonary Hypertension, Heart Failure With Preserved Ejection Fraction
Recruiting
Vasopressor Agents in Pulmonary Hypertension Crisis
Pulmonary Arterial Hypertension (PAH), Chronic Thromboembolic Pulmonary Hypertension (CTEPH)
RecruitingPhase 3
Efficacy and Safety of Tozorakimab in Patients Hospitalised for Viral Lung Infection Requiring Supplemental Oxygen
Viral Lung Infection and Acute Respiratory Failure
Referral and contact
AzTrials does not enrol participants or take referrals. Contact the study team or a site listed below; they decide who can take part. This study is not recruiting at the moment.
Fernando Guimaraes, PhD study chair
Centro Universitário Augusto Motta
1 site in 1 country: see every site and its status.
Questions about this trial
What is this clinical trial studying?
A study testing Baseline Mechanical Ventilation, VHI With Inspiratory Pause and VHI Without Inspiratory Pause in people with Respiratory Failure and Respiratory Disorders, run by Centro Universitário Augusto Motta at 1 site in Brazil.
The full registered description is in the About this study section and the official record.
Who may be eligible to take part?
The sponsor lists 1 inclusion and 9 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.
Is this clinical trial currently recruiting?
The record says: finished, as of the sponsor's last update on 14 Aug 2020. Status can change between updates, so confirm with the study contact before making plans.
Where is the study taking place?
The record lists 1 site in Brazil. Whether a site is taking part right now should be confirmed with that site. See every site.
What are the possible benefits and risks?
They depend on the study and the treatment, and no study can promise a benefit. Some participants in this study may receive a placebo. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.
Are results available for this study?
The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.
How can a doctor refer a patient or contact the research team?
The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.
What does the primary outcome measure?
Change in Cardiac Output (time frame: Baseline (before) and 10 minutes after the onset of VHI modesBasel). It is what the study was designed to measure, not a finding.
Where can I read the original study information?
On the ClinicalTrials.gov record for NCT03557645, which also lists 3 linked publications.
Does a listing mean the treatment is approved or proven to work?
No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.
How often is this information updated?
AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 14 Aug 2020.