AzTrials
AzTrials

Catheterization, PeripheralTecPrevInfNCT03563703

Transfer of Technological Innovations to Nursing Practice: A Contribution to the Prevention of Infections

A study testing Ultrasound and Near Infrared Light in people with Catheterization, Peripheral, run by Escola Superior de Enfermagem de Coimbra at 1 site in Portugal.

Completed

Finished. The study has ended and is not enrolling. Results may be posted on the official record.

Official record
Search all trials

Trial summary

The insertion of peripheral vascular catheters (PVCs) is the most often invasive procedure performed in hospital settings. During hospitalization, the majority of patients need to have a PVC inserted. These devices are not risk-free, affecting patients' safety and well-being. Read more about this study

Who is it for?
Ages 18 years and older
Conditions the study is for
Catheterization, Peripheral
What is being tested?
Ultrasound and Near Infrared Light
Could I receive a placebo?
No, everyone receives an active treatment
How many people
40 participants
Where
1 sitePortugal
Study dates
1 Oct 2018to 1 Dec 2019
Phase
Interventional
Are there results?
None posted in the registry

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 18 years and older
  • All sexes
  • No healthy volunteers
  • Adult, Older adult

Who may be able to join

  • Participants who require peripheral intravenous catheterization as part of routine care;
  • Participants whose primary nurse agrees to participate in the study;
  • Participants who are able to give written assent or oral assent.

Who cannot join

  • Confused and/or disoriented participants;
  • Participants who are unable to communicate orally and/or in writing.

Trial locations and contacts

1 site in 1 country.

Portugal1 site
  • Centro Hospitalar e Universitário de Coimbra

    Coimbra, 3000-075

Other trials in Portugal

About this study

The insertion of peripheral vascular catheters (PVCs) is the most often invasive procedure performed in hospital settings. During hospitalization, the majority of patients need to have a PVC inserted. These devices are not risk-free, affecting patients' safety and well-being. In clinical settings, health professionals must deal with difficult venous accesses due to the patient's age, physical characteristics, clinical status, and medication, which hinder the PVC insertion. When veins are not visible or palpable, this may lead to successive puncture attempts, causing pain to the patient and discomfort to the nurse, which results in increased costs.

Guidelines state that puncture should be attempted only twice per professional, to a maximum of four attempts; against this recommendation and due to the patient's therapeutic needs and clinical situation, health professionals attempt to puncture multiple times in a single scenario. In this regard, health professionals should consider using specific technologies that help to select the vein and reduce the number of puncture attempts and catheter-related mechanical complications. Taking into account the multiplicity of existing technologies in the international market that assist health professionals in peripheral venous catheterization, ultrasound and infrared devices emerge in the literature as two of the most commonly used during this procedure.

Read more

These technologies were developed with the purpose of improving peripheral intravenous catheterization success rate and thus reducing the number and extent of the negative effects of multiple or unsuccessful attempts, with the additional purpose of avoiding the frustrations of health professionals in these scenarios. However, such technologies are still underused in clinical practice, since health professionals are not familiar with the use of these devices. Moreover, the costs associated with their purchase and maintenance may be considered as excessive in relation to the traditional method.

The project investigators aim to determine whether the use of either ultrasound or near-infrared vascular imaging will significantly improve the success rate of peripheral intravenous catheterization in adults on first attempt by nurses compared with the standard approach, reduce immediate related complications and improve patient and provider satisfaction.

Being tested
Ultrasound, Near Infrared Light
Keywords
Catheterization, Peripheral, Ultrasound, Near Infrared Light

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • UltrasoundDevice

    Ultrasound allows viewing veins and surrounding anatomical structures, making it easier to perform the placement of a cannula into a peripherally located vein in real time. This process allows the cannulation of veins that are unable to be visualised or palpated.

  • Near Infrared LightDevice

    Infrared technologies allows illuminating the vein with a near-infrared light, which is absorbed by blood and reflected by adjacent tissue.

Study groups in NCT03563703
Study groupRoleWhat they receive
Ultrasound imagingExperimentalUltrasonography offers visual information about the size and depth of blood vessels, potentially facilitating intravenous placement of the needle in real time.
Receives: Device: Ultrasound
Near-infrared imagingExperimentalNear-infrared imaging devices project near-infrared light onto the skin, which is absorbed by deoxygenated hemoglobin. The invisible image of the underlying vascular pattern is captured by the device, processed and projected, in real time, back onto the patient's skin using visible green light. This technology allows hands-free visualization of a vascular map to guide catheter placement.
Receives: Device: Near Infrared Light

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. Successful intravenous catheterization on the first attempt

    Successful attempt is defined through the clear flush of the catheter with 5 mL of normal saline without extravasation.

    Measured: This outcome will be assessed immediately following intervention, an average of 20 minutes. This outcome will be assessed through study completion, an average of 6 months., assessed up to 6 months

Secondary outcomes (6)
  1. Number of attempts to successful intravenous catheter placement

    Measured: Immediately following intervention, an average of 5 minutes. This outcome will be assessed through study completion, an average of 6 months.

  2. Time to successful placement (in minutes)

    Measured: From time of randomization until the time of successful intravenous catheter placement, assessed through study completion, an average of 6 months.

  3. Patient satisfaction

    Evaluated through a self-report scale where the participant identifies a set of indicators associated to their satisfaction with the intervention, when compared to previous experiences.

    Measured: This outcome will be assessed immediately following intervention, an average of 20 minutes. This outcome will be assessed through study completion, an average of 6 months.

  4. Nurse satisfaction

    Evaluated through a self-report scale where the nurse identifies a set of indicators associated to their satisfaction with the intervention, when compared to previous experiences.

    Measured: This outcome will be assessed immediately following intervention, an average of 20 minutes. This outcome will be assessed through study completion, an average of 6 months.

  5. Immediate Complications

    Evaluated through a self-report scale where the nurse identifies a set of indicators associated to the occurrence of immediate complications during the procedure (extravasation, puncture of proximal anatomical structures, hematoma, etc.).

    Measured: This outcome will be assessed immediately following intervention, an average of 20 minutes. This outcome will be assessed through study completion, an average of 6 months.

  6. Patient anxiety (State-Trait Anxiety Inventory)

    The State-Trait Anxiety Inventory (STAI) is a commonly used measure of trait and state anxiety (Spielberger, Gorsuch, Lushene, Vagg, \& Jacobs, 1983). It can be used in clinical settings to diagnose anxiety. Form Y, its most popular version, has 20 items for assessing trait anxiety and 20 for state anxiety. All items are rated on a 4-point scale (e.g., from "Almost Never" to "Almost Always"). Higher scores indicate greater anxiety. The STAI is appropriate for those who have at least a sixth-grade reading level.

    Measured: Anxiety will be assessed about ten minutes before and ten minutes after the intervention. This outcome will be assessed through study completion, an average of 6 months.

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted20 Jun 2018
  2. Study start1 Oct 2018
  3. Primary completion30 Nov 2019
  4. Study completion1 Dec 2019

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Interventional
Phase
Phase N/A
Primary purpose
Treatment
Allocation
Randomised
Intervention model
Parallel groups
Model description
Once eligibility, informed consent and assent are confirmed, participants will be randomly assigned, in the appropriate age stratum, to 1 of 2 groups: peripheral intravenous catheterization with the standard approach or with the help of either ultrasound or near-infrared vascular imaging. Randomization will be achieved with the use of an online, computer-generated program.
Masking
Double blind
Who is masked
Investigator, Outcomes assessor
Enrolment
40 participants (actual)
IDs, dates and publications
ClinicalTrials.gov ID
NCT03563703
Sponsor's protocol ID
TecPrevInf
Acronym
TecPrevInf
Status last verified
Feb 2021
First submitted
9 May 2018
Last updated
8 Feb 2021
Results posted
No
Data monitoring committee
Yes
FDA-regulated drug
No
FDA-regulated device
No
Individual data sharing
No: No individual participant data will be shared with other researchers.

Publications

  • Marsh N, Webster J, Mihala G, Rickard CM. Devices and dressings to secure peripheral venous catheters to prevent complications. Cochrane Database Syst Rev. 2015 Jun 12;2015(6):CD011070. doi: 10.1002/14651858.CD011070.pub2.

    PubMed 26068958
  • Grune F, Schrappe M, Basten J, Wenchel HM, Tual E, Stutzer H; Cologne Quality Control Network. Phlebitis rate and time kinetics of short peripheral intravenous catheters. Infection. 2004 Feb;32(1):30-2. doi: 10.1007/s15010-004-1037-4.

    PubMed 15007740
  • Pujol M, Hornero A, Saballs M, Argerich MJ, Verdaguer R, Cisnal M, Pena C, Ariza J, Gudiol F. Clinical epidemiology and outcomes of peripheral venous catheter-related bloodstream infections at a university-affiliated hospital. J Hosp Infect. 2007 Sep;67(1):22-9. doi: 10.1016/j.jhin.2007.06.017. Epub 2007 Aug 27.

    PubMed 17719678
  • Abolfotouh MA, Salam M, Bani-Mustafa A, White D, Balkhy HH. Prospective study of incidence and predictors of peripheral intravenous catheter-induced complications. Ther Clin Risk Manag. 2014 Dec 8;10:993-1001. doi: 10.2147/TCRM.S74685. eCollection 2014.

    PubMed 25525365
  • Cicolini G, Manzoli L, Simonetti V, Flacco ME, Comparcini D, Capasso L, Di Baldassarre A, Eltaji Elfarouki G. Phlebitis risk varies by peripheral venous catheter site and increases after 96 hours: a large multi-centre prospective study. J Adv Nurs. 2014 Nov;70(11):2539-49. doi: 10.1111/jan.12403. Epub 2014 Mar 31.

    PubMed 24684163
  • Dorniak-Wall T, Rudaks L, Solanki NS, Greenwood J. Safe and correct use of peripheral intravenous devices. ANZ J Surg. 2013 Oct;83(10):764-8. doi: 10.1111/j.1445-2197.2012.06281.x. Epub 2012 Oct 4.

    PubMed 23035825
  • Ismailoglu EG, Zaybak A, Akarca FK, Kiyan S. The effect of the use of ultrasound in the success of peripheral venous catheterisation. Int Emerg Nurs. 2015 Apr;23(2):89-93. doi: 10.1016/j.ienj.2014.07.010. Epub 2014 Aug 15.

    PubMed 25175514
  • Partovi-Deilami K, Nielsen JK, Moller AM, Nesheim SS, Jorgensen VL. Effect of Ultrasound-Guided Placement of Difficult-to-Place Peripheral Venous Catheters: A Prospective Study of a Training Program for Nurse Anesthetists. AANA J. 2016 Apr;84(2):86-92.

    PubMed 27311149
  • Park JM, Kim MJ, Yim HW, Lee WC, Jeong H, Kim NJ. Utility of near-infrared light devices for pediatric peripheral intravenous cannulation: a systematic review and meta-analysis. Eur J Pediatr. 2016 Dec;175(12):1975-1988. doi: 10.1007/s00431-016-2796-5. Epub 2016 Oct 26.

    PubMed 27785562

Questions about this trial

What is this clinical trial studying?

A study testing Ultrasound and Near Infrared Light in people with Catheterization, Peripheral, run by Escola Superior de Enfermagem de Coimbra at 1 site in Portugal.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 3 inclusion and 2 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: finished, as of the sponsor's last update on 8 Feb 2021. Status can change between updates, so confirm with the study contact before making plans.

Where is the study taking place?

The record lists 1 site in Portugal. Whether a site is taking part right now should be confirmed with that site. See every site.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.

How can a doctor refer a patient or contact the research team?

The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

Successful intravenous catheterization on the first attempt (time frame: This outcome will be assessed immediately following intervention, an average of 20 minutes. This outcome will be assessed through study completion, an average of 6 months., assessed up to 6 months). It is what the study was designed to measure, not a finding.

Where can I read the original study information?

On the ClinicalTrials.gov record for NCT03563703, which also lists 9 linked publications.

Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 8 Feb 2021.

Free account

Log in to keep searching

You’ve used your 3 free searches. AzTrials is free: log in or create a free account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in